ADVANTECH EKI-1221 (03) Image

FREE ENGLISH ADVANTECH EKI-1221 (03) PDF DOCUMENT.
FREE ENGLISH ADVANTECH EKI-1221 (03) PDF USER GUIDE.
FREE ENGLISH ADVANTECH EKI-1221 (03) PDF USER MANUAL.
FREE ENGLISH ADVANTECH EKI-1221 (03) PDF OWNER GUIDE.
FREE ENGLISH ADVANTECH EKI-1221 (03) PDF OWNER MANUAL.
FREE ENGLISH ADVANTECH EKI-1221 (03) PDF REFERENCE GUIDE.
FREE ENGLISH ADVANTECH EKI-1221 (03) PDF INSTRUCTION GUIDE.
FREE ENGLISH ADVANTECH EKI-1221 (03) PDF REFERENCE MANUAL.
FREE ENGLISH ADVANTECH EKI-1221 (03) PDF INSTRUCTION MANUAL.
FREE ENGLISH ADVANTECH EKI-1221 (03) PDF OPERATING INSTRUCTIONS.


CLICK HERE TO DOWNLOAD ADVANTECH EKI-1221 (03) PDF DOCUMENT

If this is not the document you want for this product, click here to see if we have any other documents for this product.

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

What items are included in the packing list for the ADVANTECH EKI-1221?

Before installation of the ADVANTECH EKI-1221, please make sure that you have the following items:

• EKI-1221 Modbus Data Gateway x 1

• Panel mounting bracket x 2

• DIN-rail mounting kit x 1

• Utility and Driver CD

• Startup Manual


What is the ADVANTECH EKI-1221 Modbus Data Gateway?

The ADVANTECH EKI-1221 is a 1-port Modbus data gateway that integrates new and existing Modbus RTU/ASCII and newer Modbus TCP networked-base devices. It can be used to not only allow Ethernet masters to control serial slaves, but also to allow serial masters to control Ethernet slaves. It supports up to 16 connections and 32 requests simultaneously.


Are there any specific cable recommendations for the ADVANTECH EKI-1221 to ensure CE compliance?

Yes, the ADVANTECH EKI-1221 has passed the CE test for environmental specifications when shielded cables are used for external wiring. It is recommended to use shielded cables. This kind of cable is available from Advantech.


What are the Ethernet interface specifications for the ADVANTECH EKI-1221?

Speed: 10/100 Mbps, auto-sensing

No. of Ports: 2

Port Connectors: RJ45 x 2 (with LED)

Protection: Built-in 1.5 KV magnetic isolation


What are the serial interface specifications for the ADVANTECH EKI-1221?

Port Type: RS-232/422/485, software selectable

No. of Ports: 1

Port Connector: DB9 (Male)

Baud Rate: 50 bps to 921.6 Kbps

Parity: None, Odd, Even, Space, Mark

Data bits: 7, 8

Stop bits: 1, 2

Flow control: RTS/CTS, XON/XOFF, DTR/DSR

Signals:

• RS-232: TxD, RxD, CTS, RTS, DTR, DSR, DCD, RI, GND

• RS-422: TxD+, TxD-, RxD+, RxD-, GND

• RS-485: Data+, Data-, GND

Protection: 15 KV ESD for all signals, enhanced protection for RS-422/485 lines


What software is provided with the ADVANTECH EKI-1221?

Utility: Advantech Serial Device Server Configuration Utility

OS Support: Windows 2000/XP/Vista (x86)

Operation Mode: Modbus RTU Master/Slave, Modbus ASCII Master/Slave


How do I perform a panel or wall mount installation for the ADVANTECH EKI-1221?

The ADVANTECH EKI-1221 can be attached to a wall using the included metal brackets. Each bracket comes with four screws. You can install the EKI-1221 firmly via these components.


How do I mount the ADVANTECH EKI-1221 on a DIN-rail?

The ADVANTECH EKI-1221 can be mounted on a standard DIN-rail. The DIN-rail kit is screwed on the Modbus data gateway when out of factory. If the DIN-rail kit is not screwed on the EKI-1221, please screw the DIN-rail kit on the Modbus data gateway first.

1. First, hang the EKI-1221 to the DIN-rail with an angle of inclination.

2. Then, let the EKI-1221 down straight to slide over the rail smoothly.


How do I connect power to the ADVANTECH EKI-1221 and what is the power-fail relay?

The ADVANTECH EKI-1221 supports dual +12 to 48 VDC power inputs and a power-fail relay output. The power terminal block has connections for two power sources (V1+, V1- and V2+, V2-) and a power-fail relay (P-Fail).

You can connect an alarm or other signaling equipment through the power-fail relay output. The relay opens if power input V1 or V2 fails. “Open” means if you connect the relay output with an LED, the light will shut off.


How do I install the software for the ADVANTECH EKI-1221?

1. Insert the Driver Utility CD-ROM into the PC to install the Serial Device Server Configuration Utility.

2. Use Windows explorer or the Windows Run command to execute the setup program on the CD-ROM: Utility&Driver\SerialDeviceServerConfigurationUtility. The setup program name will be: Serial_Device_Server_Configuration_Utility_[Version]_Release_[Date].exe.

3. Then, follow the on-screen instructions.

Note: Be sure that you have at least version 2.0 of the Microsoft .NET Framework installed on your PC.


What are the pin assignments for the serial port on the ADVANTECH EKI-1221?

The ADVANTECH EKI-1221 provides one standard serial port DB9 (male) connector. The RS-232/422/485 pin assignments are as below:

Pin 1 2 3 4 5 6 7 8 9
RS-232 DCD RX TX DTR GND DSR RTS CTS RI
RS-422 TX- TX+ GND RX+ RX-
RS-485 Data- Data+ GND

What do the LED indicators on the ADVANTECH EKI-1221 mean?

The LEDs on the front panel of the ADVANTECH EKI-1221 display power status, system status, dual network status, and serial communication status. Each has a specific meaning as described in the table below:

Name Color LED Description
P1 Green Power 1 is on.
Off Power 1 is off, or power error condition exists.
P2 Green Power 2 is on.
Off Power 2 is off, or power error condition exists.
Status Orange Blinking: System is ready.
Steady on: The device server has been located by utility’s locating the device function.
Off System is not working.
Ethernet Orange Blinking: Ethernet port is transmitting or receiving data.
Steady on: Ethernet has the good link for 10Mbps or 100Mbps operations.
Green On: 100Mbps Ethernet connection.
Off: 10Mbps Ethernet connection.
Serial Orange Serial port is transmitting data.
Green Serial port is receiving data.
Off No data is transmitted or received through the serial port.

What are the environmental and physical specifications for the ADVANTECH EKI-1221?

Power Input: 12 to 48 VDC x 2

Power Connector: Terminal block

Power Consumption: 2W

Power Line Protection: 1 KV burst (EN61000-4-4), 0.5 KV surge (EN51000-4-5)

Dimensions (W x H x D): 37 x 140 x 95 mm

Enclosure: Metal with solid mounting hardware

Mounting: DIN-rail, panel or wall mount

Operating Temperature: 0 to 60 °C (32 to 140 °F)

Storage Temperature: -20 to 85 °C (-4 to 185 °F)

Operating Humidity: 5 to 95% RH

Regulatory Approvals: CE Class A, FCC Part 15 Subpart B Class A, UL