Free English ADC AD-320 (01) PDF document. Download the PDF, use the online viewer, or browse the FAQs for easy troubleshooting.
CLICK HERE TO DOWNLOAD ADC AD-320 (01) PDF DOCUMENT
If this is not the document you want for this product, click here to see if we have any other documents for this product.
What safety precautions should I follow when using the ADC AD-320 dryer?
Please observe all safety precautions displayed on the equipment and in the manual.
FOR YOUR SAFETY:
• DO NOT store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
• DO NOT dry mop heads in the dryer.
• DO NOT use the dryer in the presence of dry cleaning fumes.
WARNING:
• Children should NOT be allowed to play on or in the dryer(s).
• Children should be supervised if near dryer(s) in operation.
CAUTION:
• Dryer(s) should NEVER be left unattended while in operation.
IMPORTANT:
• Dryer(s) must not be installed or stored in an area where it will be exposed to water and/or weather.
• The wiring diagram for the dryer is located in the front electrical control box area.
What should I do if I smell gas near my ADC AD-320 dryer?
Instructions to be followed in the event the user smells gas must be posted in a prominent location. These instructions shall be obtained from the local gas supplier.
How do I operate the ADC AD-320 dryer in Timed Mode?
1. When turning on power or when no cycle is in progress, the L.E.D. displays will read “FILL” and/or “Amount toStart.”
2. Insert coin(s). Once the correct “Amount to Start” has been inserted, the display will read “PUSH – tEnP”.
3. Select the temperature by pushing “HI-TEMP,” “LO-TEMP,” or “PERM-PRESS.” The basket (tumbler) will start to rotate, and the L.E.D. display will read the temperature cycle selected and the drying time.
4. The basket (tumbler) will continue to rotate through the drying and cooling cycles, showing time counting downward.
NOTE: If the door is opened during a cycle, both the heat and motor will stop. However, the DMC computer will continue to count down in time. Continuation of the cycle will resume only after the door has been closed and any one of the three (3) temperature selection buttons is again depressed.
5. Upon completion of drying and cooling cycles, the buzzer (tone) will sound, and the L.E.D. display will read “donE” for five (5) seconds, at which time the basket (tumbler) will shut off.
How do I operate the ADC AD-320 dryer in Automatic Mode?
1. When turning on power or when no cycle is in progress, the L.E.D. displays will read “FILL” and/or “Amount to Start.”
2. Insert coin(s). Once the correct “Amount to Start” has been inserted, the L.E.D. display will read “PUSH – tEnP”.
3. Select the temperature by pushing “HI-TEMP,” “LO-TEMP,” or “PERM-PRESS.” The basket (tumbler) will start, the L.E.D. display will read the temperature cycle selected, and the drying time portion of the L.E.D. display will read “00” and count upward as the time elapses.
NOTE: If the door is opened during a cycle, both the heat and motor will stop. However, the DMC computer will continue to count upwards in time. Continuation of the cycle will resume only after the door has been closed and any one of the three (3) temperature selection buttons is again depressed.
4. Once the preprogrammed dryness level and cool down period have been reached or maximum automatic time has expired, whichever comes first, the buzzer (tone) will sound, and the L.E.D. display will read “donE” for five (5) seconds, at which time the basket (tumbler) will shut off.
How do I operate the ADC AD-320 dryer in Free Dry Mode?
1. When turning on power or when no cycle is in progress, the L.E.D. displays will read “FILL” and/or “FrEE”.
2. Select temperature. The basket (tumbler) will start rotating, the L.E.D. display will read the temperature cycle selected, and the drying time portion of the L.E.D. display will read the value of “Adrt” (maximum time for automatic dry), counting downward as time elapses when in the timed mode and upward when in the automatic mode.
NOTE: If the door is opened during a cycle, both the heat and motor will stop. However, the Dual Microprocessor Controller (DMC) computer will continue to count upwards in time. Continuation of the cycle will resume only after the door has been closed, and one of the three (3) temperature selection buttons is again depressed.
3. Once the preprogrammed dryness level and cool down period has been reached or maximum automatic time has expired, whichever comes first, the buzzer (tone) will sound, and the L.E.D. display will read “donE” for five (5) seconds, at which time the basket (tumbler) will shut off.
How do I enter the programming mode on my ADC AD-320 dryer?
To change programs or to put the Dual Microprocessor Controller (DMC) computer in the temperature or coin count display modes, the Program Switch (PS) located on the back side of the DMC computer must be put into the closed position (PSC).
Initial Conditions: The power is on, the dryer is idling, and no drying cycle is in progress.
| STEP | ACTION | TOP L.E.D. DISPLAY | BOTTOM L.E.D. DISPLAY | REMARKS |
|---|---|---|---|---|
| 1. | – | FILL – 25 | FILL – 25 | Flashing |
| 2. | CLOSE PS switch | 72° F | 72° F | Temperature Mode |
| 3. | Press PERM-PRESS | PL01 | Blank | Program Mode |
| 4. | Press HI-TEMP | PL02 | Blank | Location #2 |
| 5. | Press HI-TEMP | PL03 | Blank | Location #3 |
| 6. | Press HI-TEMP | PL04 | Blank | Location #4 |
| 7. | Press LO-TEMP | PL03 | Blank | Location #3 |
| 8. | Press LO-TEMP | PL02 | Blank | Location #2 |
| 9. | Press LO-TEMP | PL01 | Blank | Location #1 |
| 10. | Press PERM-PRESS | PL01 | °FAr | Temperature Scale |
Observations: Once in program mode, program locations can be indexed upward with the aid of the “HI-TEMP” key and downward with the aid of the “LO-TEMP” key.
NOTE: Holding the “HI-TEMP” or “LO-TEMP” keys down continuously will automatically strobe/scroll through ALL the program locations available.
How can I view the temperature inside the baskets of my ADC AD-320 dryer?
The temperature display mode displays the temperature inside each basket. This feature is helpful for servicing the dryers.
Initial Conditions: The power is on, the dryer is idling, and no drying cycles are in progress.
| STEP | ACTION | TOP L.E.D. DISPLAY | BOTTOM L.E.D. DISPLAY | REMARKS |
|---|---|---|---|---|
| 1. | – | FILL – 25 | FILL – 25 | Flashing |
| 2. | CLOSE PS switch | 72° F | 72° F | Room Temperature |
If the baskets were both running, the following sequence would take place:
| STEP | ACTION | TOP L.E.D. DISPLAY | BOTTOM L.E.D. DISPLAY | REMARKS |
|---|---|---|---|---|
| 1. | – | HI 20 | HI 20 | ALL dots on |
| 2. | CLOSE PS switch | 135° F | 137° F | ALL dots on |
| 3. | Open both doors | 135° F | 137° F | ALL dots off |
| 4. | Close doors | 134° F | 136° F | ALL dots off |
| 5. | OPEN PS switch | HI 15 | HI 15 | ALL dots off |
| 6. | Press HI-TEMP | HI 15 | HI 15 | ALL dots on |
Observations: Both baskets (tumblers) will continue their respective cycles until the end without any change.
How do I view and clear the Right Coin Count on my ADC AD-320 dryer?
The Right Coin Count feature displays the total number of coins sensed by the right coin switch.
Initial Conditions: The power is on, the dryer is idling, and no drying cycles are in progress.
To view the Right Coin Count:
| STEP | ACTION | TOP L.E.D. DISPLAY | BOTTOM L.E.D. DISPLAY | REMARKS |
|---|---|---|---|---|
| 1. | – | FILL – 25 | FILL – 25 | Flashing |
| 2. | CLOSE PS switch | 72° F | 72° F | Room Temperature |
| 3. | Press HI-TEMP | rCC | 56 | 56 Coins In |
| 4. | Press PERM-PRESS | 72° F | 72° F | Room Temperature |
To clear the Right Coin Count:
| STEP | ACTION | TOP L.E.D. DISPLAY | BOTTOM L.E.D. DISPLAY | REMARKS |
|---|---|---|---|---|
| 5. | Press HI-TEMP | rCC | 56 | Room Temperature |
| 6. | Press HI-TEMP | CrCC | 56 | 56 Coins In |
| 7. | Press PERM-PRESS | rCC | 00 | Room Temperature |
Note: Open Program Switch (PS) to exit from the display mode.
How do I view and clear the Left Coin Count on my ADC AD-320 dryer?
The Left Coin Count feature displays the total number of coins sensed by the left coin switch.
Initial Conditions: The power is on, the dryer is idling, and no drying cycles are in progress.
To view the Left Coin Count:
| STEP | ACTION | TOP L.E.D. DISPLAY | BOTTOM L.E.D. DISPLAY | REMARKS |
|---|---|---|---|---|
| 1. | – | FILL – 25 | FILL – 25 | Flashing |
| 2. | CLOSE PS switch | 72° F | 72° F | Room Temperature |
| 3. | Press LO-TEMP | LCC | 108 | 108 Coins In |
| 4. | Press PERM-PRESS | 72° F | 72° F | Room Temperature |
To clear the Left Coin Count:
| STEP | ACTION | TOP L.E.D. DISPLAY | BOTTOM L.E.D. DISPLAY | REMARKS |
|---|---|---|---|---|
| 5. | Press LO-TEMP | LCC | 108 | Room Temperature |
| 6. | Press HI-TEMP | CLCC | 108 | 108 Coins In |
| 7. | Press PERM-PRESS | LCC | 00 | Room Temperature |
Note: Open Program Switch (PS) to exit from the display mode.
How do I change the temperature scale from Fahrenheit to Celsius on my ADC AD-320?
You can change the temperature scale in Program Location 01 (PL01).
| STEP | ACTION | TOP L.E.D. DISPLAY | BOTTOM L.E.D. DISPLAY | REMARKS |
|---|---|---|---|---|
| 1. | – | FILL – 25 | FILL – 25 | Flashing |
| 2. | CLOSE PS switch | 72 °F | 72 °F | Temperature Display |
| 3. | Press PERM-PRESS | PL01 | Blank | Ready To Read |
| 4. | Press PERM-PRESS | PL01 | °FAr | Fahrenheit Scale |
| 5. | Press LO-TEMP | PL01 | °CEL | Celsius Scale |
| 6. | OPEN PS switch | FILL – 25 | FILL – 25 | Operational Mode |
NOTE: As a result of changing the temperature scale, all applicable temperature registers (i.e., PL03, PL04, PL05, PL06, PL07, and PL08) will automatically be converted to their equivalent Celsius temperatures.
How do I change the High Temperature setting (PL03) on my ADC AD-320 dryer?
Follow these steps to access and change the HI-drY-tEnp register (PL03).
Accessing PL03:
| STEP | ACTION | TOP L.E.D. DISPLAY | BOTTOM L.E.D. DISPLAY | REMARKS |
|---|---|---|---|---|
| 1. | – | FILL – 25 | FILL – 25 | Flashing |
| 2. | CLOSE PS switch | 72 °F | 72 °F | Room Temperature |
| 3. | Press PERM-PRESS | PL01 | Blank | Ready To Read |
| 4. | Press HI-TEMP | PL02 | Blank | Next Location |
| 5. | Press HI-TEMP | PL03 | Blank | Target Location |
| 6. | Press PERM-PRESS | HI-drY-tEnp | 140 °F | TEMP. SET-POINT |
Changing the temperature set-point:
| STEP | ACTION | TOP L.E.D. DISPLAY | BOTTOM L.E.D. DISPLAY | REMARKS |
|---|---|---|---|---|
| 1. | – | HI-drY-tEnp | 140 °F | TEMP. SET-POINT |
| 2. | Press LO-TEMP | HI-drY-tEnp | 135 °F | Decremented 5 °F |
| 3. | Press LO-TEMP | HI-drY-tEnp | 130 °F | Decremented 5 °F |
| 4. | Press HI-TEMP | HI-drY-tEnp | 135 °F | Incremented 5 °F |
| 5. | Press PERM-PRESS | PL04 | Blank | NEW SET-POINT |
NOTE: In programming mode, the PERM-PRESS key functions as the “ENTER” key. The high temperature is programmable from 100°F to 150°F in five-degree increments or from 38°C to 65°C in one-degree increments.
What are the meanings of the L.E.D. Display Codes on the ADC AD-320 dryer?
| Code | Meaning |
| A | Automatic Cycle (Slope Program Factor) |
| ACOn | Accumulative Coin |
| Add | Add More Coins |
| Adrt | Maximum Auto Dryness Time |
| AFAt | Amount for Additional Time |
| AGt | Active Anti-Wrinkle Guard Time |
| AtIn | Accumulative Time |
| AtSt | Amount to Start |
| AUTO | Automatic Mode |
| b | Automatic Cycle (Heat Loss [offset] Factor) |
| bCLO | Bad Coin Lockout |
| bCrS | Bad Coin Reset |
| bUZ | Buzzer (Tone) |
| °CEL | Degree in Celsius |
| CLCC | Clear Left Coin Count |
| Coin | Coin Mode |
| CrCC | Clear Right Coin Count |
| donE | Drying and Cooling Cycles Complete or Dryer is in Anti-Wrinkle Cycle |
| door | Door Circuit is Open |
| drYL | Dryness Level |
| dSFL | Dryer Sensor Circuit Failure |
| °FAr | Degree in Fahrenheit |
| FILL | No Cycle in Progress |
| FLS | Flash Display Active |
| FrEE | Free Dry Mode |
| GdLY | Anti-Wrinkle Delay Time |
| Gont | Anti-Wrinkle On Time |
| Grd | Anti-Wrinkle Program Active |
| HICd | High Cool Down |
| LCC | Left Coin Count |
| LCdE | Left Coin Denomination |
| LOCd | Low Cool Down |
| nbUZ | No Buzzer (Tone) |
| nFLS | No Flash Display |
| nGrd | No Anti-Wrinkle |
| OFF | Dryer is “Off” |
| PdrY | Dryness Level – Percent Dry |
| PL | Program Location |
| PPCd | Permanent Press Cool Down |
| PUSH | Amount to Start has been Inserted, Make Temperature Selection |
| rCC | Right Coin Count |
| rCdE | Right Coin Denomination |
| tEnp | Temperature |
| tInE | Timed Mode |
| tPLC | Time Per Left Coin |
What is the program location summary for the ADC AD-320 dryer?
| Program Location | Location Summary |
|---|---|
| PL01 | °F (Fahrenheit) / °C (Celsius) Automatic Mode / Timed Mode with Anti-Wrinkle / without Anti-Wrinkle Buz/Tone / no Buz/Tone for Anti-Wrinkle Free Dry Mode / Coin Mode Flash Display / no Flash Display Bad Coin Option Accumulative Time Mode / Accumulative Coin Mode |
| PL02 | Number of Automatic Peaks – DISABLED¹ |
| PL03 | High Temperature |
| PL04 | High Cool Down Temperature High Cool Down Time |
| PL05 | Low Temperature |
| PL06 | Low Cool Down Temperature Low Cool Down Time |
| PL07 | Permanent Press Temperature |
| PL08 | Permanent Press Cool Down Temperature Permanent Press Cool Down Time |
| PL09 | Left Coin Denomination |
| PL10 | Right Coin Denomination |
| PL11 | Time Per Left Coin |
| PL12 | Amount to Start |
| PL13 | Minimum Amount For More Time (on coin accumulate) |
| PL14 | Maximum Time For Automatic Dry² |
| PL15 | Anti-Wrinkle Timing |
| PL16 | Maximum Active Time for Anti-Wrinkle Cycle |
| PL17 | Percent Dry (dryness level)² |
| PL18 | “A” – Slope Factor² “B” – Heat Loss (offset) Factor² |
¹ For compatibility with existing controls.
² For Automatic Cycle ONLY.
How should I manage the optional 9 Volt Battery Back-Up for my ADC AD-320 dryer?
The optional 9 Volt Battery Back-Up allows the dryer to maintain its operating status during a momentary power interruption. The battery is not included with the option.
It is suggested that the battery be replaced at least once a year or as found necessary. The battery life will depend on the age of the battery, the amount of power interruptions, and the back-up time used.
IMPORTANT: For proper operation use alkaline batteries ONLY. Suggest Eveready Energizer, Duracell, or equivalent. DO NOT USE CARBON TYPE BATTERIES.
How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.
CLICK HERE TO DOWNLOAD ADC AD-320 (01) PDF DOCUMENT