What is included in the scope of delivery for the ABUS FUBW60120?
The following items are included with the ABUS FUBW60120:
1x ABUS FUBW60120 motion detector
3x 1.5V AA alkaline batteries
1x Mounting screw
3x Wall plugs
1x Quick Guide
1x Safety Instruction
How do you perform the initial installation and setup of the ABUS FUBW60120?
Step 1. Open the detector housing.
Step 2. Mount the base of the detector to the desired surface at a height between 2.0 meters and 2.4 meters.
Step 3. Insert the three 1.5V AA alkaline batteries. After power-up, the detector will automatically start in Secoris-RF-mode.
Step 4. Start the teach-in process at the control panel or keypad.
Step 5. When prompted by the control panel, press the tamper button (sabotage switch) on the detector to complete the pairing.
Step 6. Close the detector housing and secure it with the provided screw.
How do the jumper settings function on the ABUS FUBW60120?
The ABUS FUBW60120 uses jumpers to configure specific operational modes:
| Jumper Number | Function | Setting Options |
|---|---|---|
| 1 (Legacy) | Radio Mode | Secoris RF mode or Secvest radio-mode |
| 2 (Reset) | Operation Mode | Normal operation or Factory settings |
| 3 (PT) | PET Immunity | PET immunity off or PET immunity on (Note: This setting is only effective when the unit is operated in Secvest radio mode) |
How does the Activity LED and test mode work on the ABUS FUBW60120?
After inserting the batteries or triggering the sabotage contact, the ABUS FUBW60120 is put into test mode for 30 minutes. During this period, the rest period is reduced to only 7 seconds. In Secoris RF-mode, the device test is initiated via the alarm panel.
What are the environmental and installation guidelines for the ABUS FUBW60120?
To ensure optimal performance of the ABUS FUBW60120, follow these placement guidelines:
Do not obscure the detector’s field of view partially or completely.
Keep the detector at least 1 meter away from metal pipes or mains cables.
Maintain a distance of at least 2 meters from large objects that might block the signal or view.
Ensure the installation height is between 2.0 meters and 2.4 meters.
Avoid mounting in areas where the signal must pass through sheet steel, as it has a 0% penetration rate.
How do different materials affect the radio signal of the ABUS FUBW60120?
The following table illustrates the approximate radio signal penetration through various materials:
| Material | Penetration Percentage |
|---|---|
| Wood and plaster | 90-100% |
| Brick | 65-95% |
| Reinforced concrete | 10-70% |
| Sheet steel | 0% |
What are the technical specifications for the ABUS FUBW60120?
| Dimensions (W x H x D) | 55 x 115 x 55 mm |
| Weight | 112 g (without batteries); 180 g (with batteries) |
| Operating temperature | -10 degrees Celsius to +55 degrees Celsius |
| Radio frequency | Secoris RF mode: 868.0 – 868.5 MHz / Secvest radio-mode: 868.6625 MHz |
| Transmission range | 700m (open space) |
| Detection range | 10 m (5 m when PET immunity is switched on) |
| Aperture angle | 85 degrees |
| Battery type | 3 x AA alkaline batteries (Duracell Procell MN1500, Duracell Industrial ID1500, or Energizer E91) |
| Battery life | Up to 5.5 years |
| Microwave frequency | 24.15 GHz |
| Power consumption | 15 microamps standby current |
| Security level | Grade 2 (EN 50131-1 + A1 + A2 + A3) |
How does the low battery warning work on the ABUS FUBW60120?
The ABUS FUBW60120 features a battery under voltage threshold of 3.5V. If the battery voltage falls below 3.5V, a “Flat battery” fault report is sent to the alarm control panel to inform the user. The low battery status will restore once the voltage reaches 3.8V.
What are the intrusion and hold-up standards for the ABUS FUBW60120?
The ABUS FUBW60120 is compliant with EN 50131-2-4:2020 and EN 50131-5-3:2017 at security level 2 when installed correctly with a Secvest Wireless Alarm System FUAA50xxx or BUMO60030 Secoris BUS Wireless Extension. Note that the device is not compliant with EN 50131-2-4:2020 when the pet-immunity mode is activated.