What is the required voltage for the ZOELLER 1450-0010 submersible pump?
The ZOELLER 1450-0010 model is a 115V pump and can only be connected to 115V service. All electrical wiring or service should be done by a qualified electrician to avoid electrical shock.
How many wires does the ZOELLER 1450-0010 pump have, and does it need a control box?
The ZOELLER 1450-0010 model has 2 wires plus ground. This model cannot be used with a control box, as no control box is needed.
How should I wire the ZOELLER 1450-0010 submersible pump?
For the ZOELLER 1450-0010 pump with 2 wires plus ground, the wiring should be connected from the pump to the pressure switch, and from the pressure switch to the breaker box. The green ground wire connects from the pump to the breaker box. The pump is installed in a well with a minimum 4-inch inside diameter.
What are the general guidelines for pump horsepower and pumping depth?
As a general guideline for pump size:
1/2 HP will pump from 100 ft.
3/4 HP will pump from 200 ft.
1 HP will pump from 300 ft.
Why does my new ZOELLER 1450-0010 pump have water stains?
Your ZOELLER 1450-0010 pump may show water stains as a result of being 100% factory water tested.
What are the troubleshooting steps if my ZOELLER 1450-0010 pump won’t start?
| Possible cause | Corrective Action |
|---|---|
| 1. No power to motor | 1. Check voltage at breaker box |
| 2. Blown fuse or tripped breaker | 2. Check wire size, line voltage, wiring, pressure switch, control box, drop cable and motor winding resistance |
| 3. Loose wiring or connections | 3. Check wiring and connections |
| 4. Air locked pump | 4. Normal delivery may resume if water pump is started and stopped at one minute intervals. |
What should I check if my ZOELLER 1450-0010 pump starts and then stops?
| Possible cause | Corrective Action |
|---|---|
| 1. Inadequate voltage | 1. Line voltage must match pump voltage. |
| 2. Incorrect wire size | 2. Check for correct wire size. Replace undersized wire. |
| 3. Leak in system | 3. Check for leaks in piping |
| 4. Water-logged pressure tank | 4. Be sure tank pressure is 2 lbs. below turn-on pressure of switch. |
What should I do if my ZOELLER 1450-0010 pump quit working after starting up?
| Possible cause | Corrective Action |
|---|---|
| 1. Blown fuse, tripped breaker, pressure switch, motor or pump | 1. Refer to Troubleshooting chart in included owners manual |