What should I do before beginning the installation?

Before beginning, read the instructions completely and carefully.


What should I do with the labels, warnings, or plates from the product?

Do not remove permanently affixed labels, warnings, or plates from the product, as this may void the warranty.


What codes and ordinances should I observe?

Observe all local and national codes and ordinances.


What should I ensure regarding the product’s grounding?

Ensure that the product is properly grounded.


Who should retain the installation instructions?

The installer should leave these instructions with the consumer, who should retain them for local inspector’s use and for future reference.


What should I do with the protective film on steel and aluminum parts?

Some models are supplied with a protective film on steel and aluminum parts. This film must be removed before installing/using the appliance.


What should I do before sliding the range back?

Slide the range back so the bolt head, on the adjustable bracket assembly, is under the anti-tip bracket.


What should I look for to ensure safety?

Look for the anti-tip bracket securely attached to the floor or wall. Also, look for the adjustable bracket assembly securely attached to the back of the range.


What should I do after sliding the range forward?

Slide the range forward to verify the anti-tip bracket is installed and engaged.


What should I do if the range is moved?

Re-engage the anti-tip device if the range is moved.


What tools are needed for installation (not supplied with the appliance)?

You will need a screwdriver, tape measure, pencil, adjustable pliers, adjustable wrench, suitable protective gloves, drill, and hammer.


What is recommended when handling or installing this appliance?

The use of suitable protective clothing/gloves is recommended when handling or installing this appliance.


What should I do with all openings in the wall behind the appliance and in the floor under the appliance?

All openings in the wall behind the appliance and in the floor under the appliance shall be sealed.


What should I do before servicing the appliance?

Disconnect the electrical supply to the appliance before servicing.


What should I do when removing the appliance for cleaning and/or service?

Disconnect the AC power supply and carefully remove the range by pulling outward. Use care in handling, as the range is heavy.


What should be used when installing or removing the range for service?

When installing or removing the range for service, a rolling lift jack should be used. Do not push against any of the edges of the range in an attempt to slide it into or out of the installation.


How should the range be electrically grounded?

The range must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA No. 70-latest edition, in Canada Canadian Electrical Code. Installation should be made by a licensed electrician.


What should I do if an external electrical source is utilized?

If an external electrical source is utilized, the installation must be electrically grounded in accordance with local codes or, in the absence of local codes, with the national Electrical Code, ANSI/NFPA 70.


What is the correct way to plug in the appliance in Canada?

In Canada, this appliance is equipped with a four-prong grounding plug (NEMA 14-50P) for your protection against shock hazard and should be plugged directly into a properly grounded socket. Do not cut or remove the fourth (ground) prong from the power plug under any circumstances.


How do I install the anti-tip bracket?

The anti-tip bracket has two components: the adjustable bracket and the stability bracket. You must install both parts of the anti-tip bracket and ensure they are properly fitted together to prevent the range from tipping.


How do I fit the anti-tip bracket?

  1. Thread the bolt through the adjustable bracket and fix in place using the two supplied nuts. Ensure the nuts are well tightened.
  2. Fix the adjustable bracket to the back of the range (centered on the lower edge) using the two supplied screws and washers.
  3. Fix the stability bracket in place. It can be fixed to the floor OR on the rear wall by #4 screws (supplied), or to the floor AND on the rear wall by #8 screws (supplied). Use the proper screws according to the type of material on the floor and/ or wall. If using the plastic sleeve anchors: drill 5/16” (8mm) diameter holes and insert the supplied plastic sleeve anchors before attaching the stability bracket with the screws.
  4. Slide the range into place, ensuring the bolt on the adjustable bracket slots under the stability bracket. Adjust the length of the bolt as necessary. Ensure the two nuts are well tightened after any adjustments.

What should I check before drilling holes or inserting screws into the floor or wall?

Before drilling any holes or inserting any screws into the floor or wall, check that you will not damage any wiring or pipes.


What should I do to avoid electrical shock hazard before installing the appliance?

Before installing the appliance, switch power off at the service panel and lock the panel to prevent the power from being switched on accidentally.


What should I do with the appliance in Canada?

In Canada, electrical installation must be in accordance with the current CSA C22.1 Canadian Electrical Codes Part1 and/or local codes. It is mandatory to connect the range by using a cordset with plug supplied.


What type of range cord should I use?

Use only 3-conductor or 4-conductor CSA/UL listed range cord rated at 50 amps with 250 V minimum and provided with ring terminals. These cords should be provided with strain relief or conduit connector.


How should the range be connected?

The range must be connected to the proper electrical voltage and frequency as specified on the rating plate. The range can be connected directly to the fused disconnect (or circuit breaker box) through flexible, armored or non-metallic sheathed, copper cable (with grounding wire). Allow two to three feet of slack in the line so that it can be moved if servicing is ever necessary.


What is recommended for installations within the United States?

For installations within the United States, it is highly recommended to use a 4-wire power cord. Using the 3-wire installation may result in insufficient power to your range and will result in poor heating performance resulting in very long cooking times.


How do I perform a permanent connection (hard wiring)?

Units may be hard-wired to the power supply. The installer must provide approved flexible aluminum conduit, 3/4” (19mm) trade size, maximum 6ft (1.8m) long. Locate the terminal block on the rear of the unit and remove the access cover. The strain relief bracket orientation must be so that the 1 1/8” (29mm) smaller opening is facing down. If not, the strain relief bracket orientation must be switched in order to accommodate for a permanent wiring connection.


What should I do if a factory-supplied power cord is fitted?

Remove the factory-supplied power cord with a plug. Remove the 2 screws on the bracket. Re-secure the bracket with the 2 screws so that the 1 1/8” (29mm) smaller opening is facing down.


How do I install the conduit?

The conduit must be installed to the terminal block using an approved conduit connector. The free end of the conduit must be connected to a junction box provided in the electrical supply zone. Mount a strain relief (not provided) into the 1 1/8” (29mm) diameter hole located below the terminal block. Wiring for the unit is to be brought into the terminal block through the conduit and through the strain relief. Make suitable connections to the terminal block provided.


What should the installer show the owner?

The installer should show the owner the location of the circuit breaker and mark it for easy reference.


How do I perform a 4-wire installation?

  1. Loosen the L1, L2, and neutral screws.
  2. Mount the conduit fitting to the 1 1/8” (29mm) hole in the strain relief bracket.
  3. Secure the neutral power lead to the center terminal and tighten the screw.
  4. Secure the L1 and the L2 power leads to the terminals immediately to the left (L1) and right (L2) of the neutral terminal. Tighten the screws.
  5. Secure the Ground lead to the green screw located to the right of the terminal block using the supplied cupped washer. The end of the grounding conductor must be retained by the cupped washer.
  6. Check that all connections are securely tightened.
  7. Reinstall the Terminal Block cover.

How do I perform a 3-wire connection (using the supplied Ground lead)?

  1. Loosen the L1, L2, and neutral screws.
  2. Mount the conduit fitting to the 1 1/8” (29mm) hole in the strain relief bracket.
  3. Secure the supplied Ground lead to the grounding screw to the right of the terminal block.
  4. Secure the Neutral power lead together with the free end of the Ground lead to the center terminal. Tighten the screw.
  5. Secure the L1 and the L2 power leads to the terminals immediately to the left (L1) and right (L2) of the neutral terminal. Tighten the screws.
  6. Check that all connections are securely tightened.

What should I do before any operation of maintenance?

Before any operation of maintenance, disconnect the appliance from the electrical main supply.


What is recommended if codes permit and a separate ground wire is used?

If codes permit and a separate ground wire is used, it is recommended that a qualified electrician installer determine that the ground path and wire gauge are in accordance with local codes.


What should I ensure regarding the electrical connection and wire size?

Be sure that the electrical connection and wire size are adequate and in conformance with: ANSI/NFPA 70 latest edition and local codes and ordinances; CSA Standard C22.1, Canadian Electrical Code, Part 1 – latest edition, and all local codes and ordinances.


What should I not do regarding grounding?

Do not ground to a gas pipe.


What should I check if I am not sure the range is properly grounded?

Check with a qualified electrical installer if you are not sure the range is properly grounded.


What should I not have in the neutral or ground circuit?

Do not have a fuse in the neutral or ground circuit.


What is required when a 4-wire, two-phase 240-208/120-volt, 60Hz, AC-only electrical supply is available?

When a 4-wire, two-phase 240-208/120-volt, 60Hz, AC-only electrical supply is available, a 30 amp maximum circuit protection is required, fused on both sides of the line.


What type of fuse or circuit breaker is recommended?

A time-delay fuse or circuit breaker is recommended.


What is the range equipped with?

This range is equipped with a Certified Power Cord intended to be plugged into a standard 14-50R wall receptacle. Be sure the wall receptacle is within reach of the range’s final location.


Should I use an extension cord?

Do not use an extension cord.


What should I do in the case of substitution of the power cord?

In the case of substitution of the power cord, always replace it with a suitable UL or CSA-approved one (with the same technical features as the replaced cord). Tighten the power cord by using only the power cord strain relief bracket supplied with the appliance. Allow enough slack to easily attach the cord terminals to the terminal block. These operations must be carried out only by an authorized technician.