What important instructions should be followed before beginning installation of the VERONA VPRFSEE365?

Before beginning, please read these instructions completely and carefully.

Do not remove permanently affixed labels, warnings, or plates from the product. This may void the warranty.

Please observe all local and national codes and ordinances.

Please ensure that this product is properly grounded.

The installer should leave these instructions with the consumer who should retain for local inspector’s use and for future reference.


What are the electrical installation requirements for the VERONA VPRFSEE365 in the US and Canada?

Electrical installation must be in accordance with the National Electrical Code, ANSI/NFPA70 – latest edition and/or local codes.

IN CANADA: Electrical installation must be in accordance with the current CSA C22.1 Canadian Electrical Codes Part 1 and/or local codes.


What should be done if some parts of the VERONA VPRFSEE365 are supplied with a protective film?

Some models are supplied with a protective film on steel and aluminum parts. This film must be removed before installing/using the appliance.


What is the warning regarding tip-over hazard for the VERONA VPRFSEE365?

A child or adult can tip the VERONA VPRFSEE365 and be killed.

Install anti-tip device to range and/or structure per installation instructions.

Engage the range to the anti-tip device Installed to the structure.

Re-engage anti-tip device if range is moved.

Failure to follow these instructions can result in death or serious burns to children and adults.


How can I verify the anti-tip bracket is installed and engaged on the VERONA VPRFSEE365?

To verify the anti-tip bracket is installed and engaged:

Slide range forward.

Look for the anti-tip bracket securely attached to floor or wall.

Look for the adjustable bracket assembly securely attached to the back of the range.

Slide range back so bolt head, on the adjustable bracket assembly, is under anti-tip bracket.

See installation instructions for details.


What is the warning about chemicals for the VERONA VPRFSEE365 concerning California Proposition 65?

This product can expose you to chemicals including formaldehyde, which is known to the State of California to cause cancer, and lead, which is known to the State of California to cause birth defects or other reproductive harm.


For what application is the VERONA VPRFSEE365 designed and what happens to the warranty if used otherwise?

This appliance is designed and manufactured solely for the cooking of domestic (household) food and in not suitable for any non domestic application and therefore should not be used in a commercial environment.

The appliance warranty will be void if the appliance is used within a non domestic environment i.e. a semi commercial, commercial or communal environment.


What tools are needed for the installation of the VERONA VPRFSEE365?

The tools needed for installation (not supplied with the appliance) are:

Tool
Screwdriver
Hammer
Pencil
Tape measure
Suitable protective gloves
Adjustable wrench
Adjustable pliers
Drill

Who must install the VERONA VPRFSEE365?

THIS APPLIANCE MUST BE INSTALLED BY A QUALIFIED INSTALLER.

Installation must conform with local codes.

Improper installation, adjustment, alteration, services, or maintenance can cause injury or property damage. Consult a qualified installer or a service agent.


Is special protective clothing recommended when installing the VERONA VPRFSEE365?

The use of suitable protective clothing/gloves is recommended when handling, installing of this appliance.


What are the general safety considerations for the VERONA VPRFSEE365 regarding space heating and clear area?

This appliance shall not be used for space heating. This information is based on safety considerations.

All openings in the wall behind the appliance and in the floor under the appliance shall be sealed.

Keep appliance area clear and free from combustible materials, gasoline, and other flammable vapors.

Do not obstruct the flow of ventilation air.


What steps should be taken before servicing or removing the VERONA VPRFSEE365?

Disconnect the electrical supply to the appliance before servicing.

When removing appliance for cleaning and/or service:

A. Disconnect AC power supply.

B. Carefully remove the range by pulling outward. CAUTION: Range is heavy; use care in handling.


What is the electrical grounding instruction for the VERONA VPRFSEE365?

The range must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA No. 70-latest edition, in Canada Canadian Electrical Code. Installation should be made by a licensed electrician.

FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED.

If an external electrical source is utilized, the installation must be electrically grounded in accordance with local codes or, in the absence of local codes, with the national Electrical Code, ANSI/NFPA 70.


Where can replacement parts for the VERONA VPRFSEE365 be obtained?

Only authorized replacement parts may be used in performing service on the range. Replacement parts are available from factory authorized parts distributors. Contact the nearest parts distributor in your area.


What are the dimensions for the VERONA VPRFSEE365 when considering proximity to side cabinets?

Range dimensions:

width: 35 7/8″ (911 mm) (width of cabinetry opening 36″, 914 mm)

depth: 25″ 1/4 (641 mm)

height (without backguard): MIN 35″ 3/8 (898 mm) – MAX 37″ 1/4 (946 mm)

backguard (height): 3″ (76 mm)

island trim (height): level with cooking hob


What are the requirements for the grounded outlet for the VERONA VPRFSEE365?

The electric cord with 4-prong ground plug (NEMA 14-50P) shall have a minimum length of 48″ (1220 mm) beyond the back of the appliance. The grounded outlet should be located 7/32″ (6 mm) from the left or right side for 35″ 7/16 (899 mm) towards the center of range; from 8″ 1/8 (206.5 mm) to 10″ 3/32 (256.5 mm) [depending on feet regulation] from the floor.


What are the minimum side clearance requirements for the VERONA VPRFSEE365 adjacent to vertical surfaces?

The range CANNOT be installed directly adjacent to sidewalls, tall cabinets, tall appliances, or other side vertical surfaces above 36″ (914 mm) high.

There must be a minimum of 2″ (50 mm) side clearance from the range to such combustible surfaces TO THE LEFT or TO THE RIGHT above the 36″ (914 mm) high countertop.

IMPORTANT: One side (left or right) above the 36″ (914 mm) high countertop must always be kept clear.


What is the maximum recommended upper cabinet depth and minimum clearance from cooking surface to overhead cabinet or ventilation hood for the VERONA VPRFSEE365?

The maximum upper cabinet depth recommended is 13″ (330 mm). Wall cabinet above the range must be a minimum of 30″ (762 mm) (see also “Additional information about minimum clearance from cooking surface to overhead cabinet or ventilation hood” here below) above the countertop for a width of minimum 36″ (911 mm): it has to be centered with the range. Side wall cabinets above the range must be a minimum of 18″ (457 mm) above the countertop.

Additional information about minimum clearance from cooking surface to overhead cabinet or ventilation hood:

30″ (762 mm), overhead cabinet centered above the cooktop (combustible/unprotected) (see also notes #1, #2)

24″ (610 mm), overhead cabinet centered above the cooktop (non-combustible/protected) (see also notes #1, #2)

24″ (610 mm), ventilation hood centered above the cooking surface (see also notes #3)

Note #1: To eliminate the risk of burns or fire by reaching over heated surface units, cabinet storage space located above the surface units should be avoided. If cabinet storage is to be provided, the risk can be reduced by installing a rangehood that projects horizontally a minimum of 5 ” (127mm) beyond the bottom of the cabinets.

Note #2: 30″ (762mm) minimum clearance between the top of the cooking surface and the bottom of an unprotected wood or metal cabinet; or 24″ (610mm) minimum when bottom of wood or metal cabinet is protected by not less than 1/4″ thick flame retardant millboard covered with not less than No. 28 MSG sheet steel, 0.015″ (0.4 mm) thick stainless steel, 0.024″ (0.6 mm) thick aluminum, or 0.020″ (0.5 mm) thick copper.

Note #3: Refer to local/national codes for ventilation requirements.


What are the dimensions specified for the area for ELECTRICAL connection for the VERONA VPRFSEE365?

Table for Electric Connection dimensions:

Ref. inch mm
A 1/4″ 6
B 35″ 3/8 899
C 8″ 1/8 – 10″ 1/8 (*) 207 – 257 (*)

(*): Depending on feet regulation


What is mandatory regarding the island trim and backguard for the VERONA VPRFSEE365?

It is mandatory to install and use the appliance with the island trim or backguard correctly in place.

The island trim is already fitted to the appliance while the backguard can be purchased as a separate kit.

If replacing the island trim with the backguard, assemble it by using the same screws/spacers used for fixing the island trim.


What are the dimensions and clearances for PROXIMITY TO SIDE CABINETS for STANDARD INSTALLATION AND ISLAND INSTALLATION of the VERONA VPRFSEE365?

Table for Proximity to Side Cabinets:

Ref. inch mm
A 0″ 0
B 36″ (*) 914 (*)
C 2″ 50
D 30″ minimum (**) 762 minimum (**)
E 18″ minimum 457 minimum
F 13″ maximum 330 maximum
G 20″ minimum 500 minimum
H 0″ 0

(*) Maximum height of cabinetry immediately adjacent to the range (from floor to countertop). Depending on the height of the feet adjustment. The cooking surface must sit flush or above countertop level.

(**) See also “Additional information about minimum clearance from cooking surface to overhead cabinet or ventilation hood” at page no.6.


What is the procedure for FITTING THE ADJUSTABLE FEET on the VERONA VPRFSEE365?

The adjustable feet must be fitted to the base of the cooker before use.

Rest the rear of the cooker on a piece of the polystyrene packaging exposing the base for the fitting of the feet.

ATTENTION: Most important! Pay special attention not to damage the range during this operation.

Fit the 4 legs by screwing them tight into the support base.


How is the VERONA VPRFSEE365 cooker levelled?

The cooker may be levelled by screwing the lower ends of the feet IN or OUT. It is important to observe the directions of figure 1.7.


What are the warnings when MOVING THE COOKER (VERONA VPRFSEE365)?

WARNING: When raising cooker to upright position always ensure two people carry out this manoeuvre to prevent damage to the adjustable feet.

WARNING: Be careful: do not lift the cooker by the door handle when raising to the upright position.

WARNING: When moving cooker to its final position DO NOT DRAG. Lift feet clear of floor.


What are the components of the anti-tip bracket for the VERONA VPRFSEE365?

The anti-tip bracket has two components:

the adjustable bracket

the stability bracket


What must be done with both parts of the anti-tip bracket for the VERONA VPRFSEE365?

You must install both parts of the anti-tip bracket and ensure they are properly fitted together to prevent the range from tipping.


What is the first step to fit the anti-tip bracket on the VERONA VPRFSEE365?

Thread the bolt through the adjustable bracket and fix in place using the two supplied nuts. Ensure the nuts are well tightened.


What is the second step to fit the anti-tip bracket on the VERONA VPRFSEE365?

Fix the adjustable bracket to the back of the range (centered on the lower edge) using the two supplied screws and washers.


How can the stability bracket be fixed in place for the VERONA VPRFSEE365 anti-tip device?

Fix the stability bracket in place. It can be fixed as follows:

To the floor OR on the rear wall by #4 screws (supplied).

To the floor AND on the rear wall by #8 screws (supplied).

There are 8 x wood screws and 8 x screws with plastic sleeve anchors supplied with the range in two separate kits. Use the proper screws according to the type of material on the floor and/or wall.

If using the plastic sleeve anchors: drill 5/16″ (8mm) diameter holes and insert the supplied plastic sleeve anchors before attaching the stability bracket with the screws.


What is important to check before drilling holes or inserting screws into the floor or wall when installing the stability bracket for the VERONA VPRFSEE365?

Before drilling and holes or inserting any screws into the floor or wall check that you will not damage any wiring or pipes.


What is the final step when sliding the VERONA VPRFSEE365 range into place after installing the anti-tip bracket components?

Slide the range into place, ensuring the bolt on the adjustable bracket slots under the stability bracket.

Adjust the length of the bolt as necessary. Ensure the two nuts are well tightened after any adjustments.


What are the electrical requirements and voltage/power consumption for the VERONA VPRFSEE365?

ELECTRICAL REQUIREMENTS:

This appliance must be properly installed and grounded by a qualified technician in accordance with the National Electrical Code ANSI/NFPA No.70 (latest edition) and local electrical code requirements. IN CANADA: Electrical installation must be in accordance with the current CSA C22.1 Canadian Electrical Codes Part1 and/or local codes.

This appliance may be connected by means of permanent “Hard Wiring” or “Power Supply Cord Kit”.

For USA only: power supply cord is not supplied, but it is available through your local electric supply house.

For Canada only: it is mandatory to connect the range by using cordset with plug supplied.

Use only 3-conductor or 4-conductor CSA/UL listed range cord rated at 50 amps with 250 V minimum and provided with ring terminals. These cords should be provided with strain relief or conduit connector.

Warning: Frame grounded through neutral lead. If used in, New branch-circuit installations (1996 NEC), Mobile homes, Recreational vehicles, or In an area where local codes prohibit grounding through neutral, use a 4 conductor cord or conduit.

The range must be connected to the proper electrical voltage and frequency as specified on the rating plate.

The range can be connected directly to the fused disconnect (or circuit breaker box) through flexible, armored or non-metallic sheathed, copper cable (with grounding wire). Allow two to three feet of slack in the line so that it can be moved if servicing is ever necessary.

Voltage and Power Consumption:

AC 120/240 V 60 Hz AC 120/208 V 60 Hz
11150 W MAX 46.63 A MAX 8380 W MAX 40.30 A MAX

For installations within the United States, it is highly recommended to use a 4-wire power cord. Using the 3-wire installation may result in insufficient power to your range, and will result in poor heating performance resulting in very long cooking times.


What is the procedure for ELECTRICAL CONNECTION WITH POWER CORD for the VERONA VPRFSEE365?

Use a 3-wire power supply cord kit rated for 50 amps – 125/250 volts with closed loop terminals and marked for use with ranges. Where local codes do not permit grounding through neutral, use a 4-wire power supply cord kit.

The cord must be secured to the range with a suitable strain relief. The electrical connection is made at the terminal block, which is located behind the terminal block access plate on the back of the range.


What are the requirements for ELECTRICAL CONNECTION WITH CONDUIT for the VERONA VPRFSEE365?

Use 3/4″ trade size CSA/UL-listed conduit with a conduit clamp, 10 AWG/600 volt copper conductor colored red for line 1 and black for line 2 and 12 AWG/600 volt copper conductor (or 10 AWG/600 Volt copper conductor if grounding through neutral) colored white for neutral with closed loop terminals marked for use with ranges.

Where local codes do not permit grounding through neutral, use a green 10 AWG copper conductor as directed in the 4-wire connector directions. The conduit must be secured to the range with the strain relief bracket. The electrical connection is made at the terminal block which is located behind the terminal block access plate on the back of the range.


What is required for PERMANENT CONNECTION (HARD WIRING) for the VERONA VPRFSEE365 in Canada?

For Canada only: it is mandatory to connect the range by using cordset with plug supplied.


What are the steps for preparing the strain relief bracket for PERMANENT CONNECTION (HARD WIRING) on the VERONA VPRFSEE365?

The strain relief bracket orientation must be so that the 1 1/8″ (29mm) smaller opening is facing down. If not, the strain relief bracket orientation must be switched in order to accommodate for a permanent wiring connection:

1. Remove the 2 screws on the bracket.

2. Re-secure bracket with the 2 screws so that the 1 1/8″ (29mm) smaller opening is facing down.


How must the conduit be installed when hard wiring the VERONA VPRFSEE365?

The conduit must be installed to the terminal block using an approved conduit connector. The free end of the conduit must be connected to a junction box provided in the electrical supply zone.

Mount a strain relief (not provided) into the 1 1/8″ (29mm) diameter hole located below the terminal block. Wiring for the unit is to be brought into the terminal block through the conduit and through the strain relief. Make suitable connections to the terminal block provided.

Installer Show the owner the location of the circuit breaker. Mark it for easy reference.


What are the steps for a 4-Wire Installation (fig. 3.2) for the VERONA VPRFSEE365?

1. Loosen the L1, L2 and neutral screws.

2. Mount the conduit fitting to the 1 1/8″ (29mm) hole in the strain relief bracket.

3. Secure the neutral power lead to the center terminal and tighten the screw.

4. Secure the L1 and the L2 power leads to the terminals immediately to the left (L1) and right (L2) of the neutral terminal. Tighten the screws.

5. Secure the Ground lead to the green screw located to the right of the terminal block using the supplied cupped washer. The end of the grounding conductor must be retained by the cupped washer.

6. Check all connections are securely tightened.

7. Reinstall the Terminal Block cover.


What are the steps for a 3-Wire Connection (using supplied Ground lead) (fig. 3.3) for the VERONA VPRFSEE365?

1. Loosen the L1, L2 and neutral screws.

2. Mount the conduit fitting to the 1 1/8″ (29mm) hole in the strain relief bracket.

3. Secure the supplied Ground lead to the grounding screw to the right of the terminal block.

4. Secure the Neutral power lead together with the free end of the Ground lead to the center terminal. Tighten the screw.

5. Secure the L1 and the L2 power leads to the terminals immediately to the left (L1) and right (L2) of the neutral terminal. Tighten the screws.

6. Check all connections are securely tightened.

7. Reinstall the Terminal Block cover.


What is the warning associated with fitting a 3-prong plug on the VERONA VPRFSEE365?

WARNING: DO NOT FIT A 3-PRONG PLUG