PDF Content Summary: UTi165H Professional Thermal Imager User Manual P/N:110401109192X UTi165H User Manual Preface Thank you for purchasing this brand new product. In order to use this product safely and correctly, please read this manual thoroughly, especially the safety notes. After reading this manual, it is recommended to keep the manual at an easily accessible place, preferably close to the device, for future reference. Limited Warranty and Liability Uni-Trend guarantees that the product is free from any defect in material and workmanship within one year from the purchase date. This warranty does not apply to damage caused by accident, negligence, misuse, modification, contamination or improper handling. The dealer shall not be entitled to give any other warranty on behalf of Uni-Trend. If you need warranty service within the warranty period, please contact your seller directly. Uni-Trend will not be responsible for any special, indirect, incidental or subsequent damage or loss caused by using this device. UTi165H UTi165H User Manual User Manual Table of Contents 1. Safety Instructions To ensure proper use of this product, please read the instructions carefully before using. The optimal measuring distance for this product is 1 meter. To ensure measurement accuracy, please use the product in an operating environment of 15°C~30°C, <85% RH (non-condensing). Please use the product indoors without wind. When changing to a new environment, please turn on the product and leave 1. Safety Instructions ---------------------------------------------------------- 4 it for 10 to 15 minutes before measuring. 2. Structure -----------------------------------------------------------------------5 The ambient temperature for measuring must be stable. Do not measure in 3. Display ------------------------------------------------------------------------- 6 4. Power On/Off ---------------------------------------------------------------- 6 5. Menu Introduction ---------------------------------------------------------- 7 6. Operating Instructions ----------------------------------------------------- 8 7. USB Communication ----------------------------------------------------- 16 8. Specifications -------------------------------------------------------------- 17 places with large airflow such as fans and air outlets. When the measured object comes from a place with a large temperature difference from the measurement environment, keep it in the measurement environment for 10 to 30 minutes before measuring. The product tests the surface temperature of the object. If temperature compensation is needed, please adjust in the Settings menu. The product has a self-calibration function. If the reading jumps quickly, please 9. Maintenance --------------------------------------------------------------- 19 read the temperature after it gets steady. 10.Common Emissivity ------------------------------------------------------ 19 After measuring extremely high or low temperature objects, please leave the product for 10 minutes before next use. Do not use the product in places with strong sunlight or electromagnetic interference. Please do not use this product in flammable, explosive, steamy, wet or corrosive environments. Please stop using the product if it is damaged or modified to avoid inaccurate measurement results. Please use the correct emissivity to obtain accurate temperature readouts. To ensure accuracy of the product, please warm it up for 10 minutes before measuring if it has not been used for a long time. When being charged, the internal temperature of the product rises, which will lead to inaccurate temperature measurement. So, it is not recommended to take measurements during or right after charging the product. The inherent temperature drift of the sensor will occasionally cause inaccurate measurement. In this case, press the down button under the temperature measurement interface to bring out “Calibrating” and automatically calibrate the temperature. 2. Structure Item Description Item Item Item Micro SD card slot Type-C USB interface Interface cover LED light Infrared camera lens cover Trigger Infrared camera lens LCD Power button UTi165H User Manual UTi165H User Manual Description Tripod mounting hole Flashlight button Left button Down button Right button Back button Replay button Up button SET button 3. Display Display size: 2.8” Display resolution: 320 (vertical) x 240 (horizontal) pixels Description Temperature unit option Cursor option Color palette option High/Low temperature alarm option Settings option Temperature bar lower value Temperature bar upper value Description Maximum temperature point Center point Center point temperature Maximum temperature Date & time Battery status 4. Power On/Off Press the power button for 3s to power on, and press the power button for 1s to power off. 5. Menu Introduction Main menu Submenu Temperature unit option Cursor optionColor palette option Thermal imaging page High/Low temperature alarm option Settings option UTi165H User Manual UTi165H User Manual 6.Operating Instructions 6.1 Temperature Unit Selection 1. Press the SET button to open the main menu. 2. Press the left/right button to select the option. 3. Press the SET button to enter the temperature unit submenu. 4. Press the up/down button to select °C or °F. 5. Press the back button to exit the current menu. 6.2 Center Point and High Temperature Tracking To track center point temperature: 1. Press the SET button to open the main menu. 2. Press the left/right button to select the option. 3. Press the SET button to enter the cursor submenu. 4. Press the up/down button to select the option. 5. Press the SET button to confirm. 6. The center point marker is turned on (the center point temperature is displayed in the upper left corner). 7. Press the back button to exit the current menu.

To track high temperature: 1. Press the SET button to open the main menu. 2. Press the left/right button to select the option. 3. Press the SET button to enter the cursor submenu. 4. Press the up/down button to select the option. 5. Press the SET button to confirm. 6. The high temperature indicator is turned on and the corresponding temperature is displayed in the upper left corner. 7. Press the back button to exit the current menu. 6.3 Color Palette Selection 1. Press the SET button to open the main menu. 2. Press the left/right button to select the option. 3. Press the SET button to enter the color palette submenu. 4. Press the up/down button to select the desired color from Iron Red, Rainbow, White Hot, Red Hot, and Ice Blue. 5. Press the back button to exit the current menu. To enter Settings menu: 1. Press the SET button to open the main menu. 2. Press the left/right button to select the option. 3. Press the SET button to confirm.

UTi165H User Manual UTi165H User Manual 6.4 High/Low Temperature Alarm To enable high/low temperature alarm: 1. Press the SET button to open the main menu. 2. Press the left/right button to select the option. 3. Press the SET button to enter the high/low temperature alarm submenu. 4. Press the up/down button to select HI (High) or LO (Low). 5. Press the SET button to confirm. 6. Press the back button to exit the current menu. Note: High temperature alarm and low temperature alarm can be enabled simultaneously or separately. 6.5 Settings

6.5.1 Language To set language: 1. Press the up/down button to select the Language option in the Settings menu. 2. Press the SET button to enter the Language submenu. 3. Press the up/down button to select the desired language from Chinese and English. 4. Press the SET button to confirm. 5. Press the back button to exit the current menu. 6.5.2 Date & Time To set date & time: 1. Press the up/down button to select the Date & Time option in the settings menu. 2. Press the SET button to enter the Date & Time submenu. 3. Press the left/right button to select the parameter to be adjusted. 4. Press the SET button to enter the parameter adjustment state. 5. Press the up/down button to increase or decrease the value. 6. Press the SET button to save the settings and return to set other parameters. 7. Press the back button to exit the current menu. 6.5.3 Emissivity/Temperature Compensation To set emissivity/temperature compensation: 1. Press the up/down button to select the Emissivity option in the Settings menu. 2. Press the SET button to enter the Emissivity submenu. 3. Press the up/down button to select emissivity or temperature compensation. 4. Press the SET button to enter the parameter adjustment state. 5. Press the up/down button to increase or decrease the value. 6. Press the SET button to save the settings. 7. Press the back button to exit the current menu. Note: For emissivity values of common materials, please refer to the Common Emissivity. 6.5.4 Auto Power Off To set auto power off: 1. Press the up/down button to select the Auto Power Off option in the settings menu. 2. Press the SET button to enter the Auto Power Off submenu. 3. Press the up/down button to select the desired option from 5 Min, 10 Min, 30 Min, and Off. 4. Press the SET button to confirm. 5. Press the back button to exit the current menu.

UTi165H User Manual UTi165H User Manual

6.5.5 Display Brightness To set display brightness: 1. Press the up/down button to select the Brightness option in the settings menu. 2. Press the SET button to enter the Brightness submenu. 3. Press the up/down button to select the desired option from Low, Middle, and High. 4. Press the SET button to confirm. 5. Press the back button to exit the current menu. 6.5.6 Temperature Bar To turn on/off temperature bar: 1. Press the up/down button to select the Temp Bar option in the settings menu. 2. Press the SET button to enter the Temp Bar submenu. 3. Press the up/down button to select On or Off. 4. Press the SET button to confirm. 5. Press the back button to exit the current menu. 6.5.7 Alarm Temperatures To set alarm temperatures: 1. Press the up/down button to select the HI/LO Alert option in the settings menu. 2. Press the SET button to enter the HI/LO Alert submenu. 3. Press the up/down button to select the desired option from HI Alert and LO Alert. 4. Press the SET button to enter the temperature adjustment state. 5. Press the up/down button to adjust the temperature. 6. Press the SET button to save the settings and return to set another temperature. 7. Press the back button to exit the current menu. 6.5.8 Device Information To view the device information: 1. Press the up/down button to select the Device Info option in the settings menu. 2. Press the SET button to view the detail information of the device. 3. Press the back button to exit the current menu.

UTi165H User Manual UTi165H User Manual 2.1

6.5.9 Factory Reset To restore settings: 1. Press the up/down button to select the Factory Reset option in the settings menu. 2. Press the SET button to enter the Factory Reset submenu. 3. Press the up/down button to select Yes. 4. Press the SET button to confirm. 5. Press the back button to exit the current menu. 6.5.10 Format SD Card To format SD card: 1. Press the up/down button to select the Format SD option in the settings menu. 2. Press the SET button to enter the Format SD submenu. 3. Press the up/down button to select Yes. 4. Press the SET button to confirm. 5. Press the back button to exit the current menu. 6.5.11 Auto Save To turn on/off auto save: 1. Press the up/down button to select the Auto Save option in the settings menu. 2. Press the SET button to enter the Auto Save submenu. 3. Press the up/down button to select On or Off. 4. Press the SET button to confirm. 5. Press the back button to exit the current menu. Operation Guide). 2. Connect the USB cable to the PC. 3. Users can browse pictures and analyze data through the PC software. Regarding its usage, retrieve the Software User Manual from the Help option of the operation interface. Note: Do not unplug the USB cable while the software is loading pictures.

UTi165H User Manual UTi165H User Manual Note: Do not remove or insert the SD card in saving or viewing pictures. If the SD card is replaced during use, restart the device after the replacement to take and save pictures. 7.USB Communication 1. Download and install the PC software (refer to UNI-T Documents Download

8. Specifications Sensor Temperature range Measurement resolution Accuracy Optimal measuring distance Minimum measuring distance Response time IR resolution Pixel size Color palette Infrared spectral band Field of view (FOV) Spatial resolution (IFOV) Thermal sensitivity (NETD) Frame rate Image format Yes Type-C USB interface 236mm x 75.5mm x 86mm 2.8” TFT LCD 320 × 240 pixels 3.7V/5000mAh rechargeable Li-ion battery 5 minutes, 10 minutes, 30 minutes, off (default: 30 minutes) ≥6 hours 4 hours 5V/2A Micro SD card -20°C~60°C (-4°F~140°F), <85% RH (non-condensing) 15°C~30°C (59°F~86°F), <85% RH (non-condensing) ≤2000m User manual, USB cable, 16GB Micro SD card Certifications -CE (EN 61326-1:2013, EN 61326-2-2:2013, EN 61326-2-3) -RoHS UFPA UFPA 30°C~45°C 30°C~45°C 0.1°C 0.1°C ±0.5°C (at 25°C ambient temperature) ±0.5°C (at 25°C ambient temperature) 1 meter 1 meter 15cm 15cm ≤500ms ≤500ms 19,200 pixels (160 × 120) 19,200 pixels (160 × 120) 12μm 12μm 12μm Iron Red, Rainbow, White Hot, Red Hot, Ice Blue Iron Red, Rainbow, White Hot, Red Hot, Ice Blue Iron Red, Rainbow, White Hot, Red Hot, Ice Blue 8μm~14μm 8μm~14μm 8μm~14μm 56° (H) × 42° (V) 56° (H) × 42° (V) 56° (H) × 42° (V) 11mrad 11mrad <50mK <50mK <9Hz <9Hz BMP BMP General parameters PC software PC software PC software Data transmission Data transmission Data transmission Product size (L x W x H) Product size (L x W x H) Product size (L x W x H) Display type Display type Display type Display resolution Display resolution Display resolution Battery Battery Battery Auto power off Auto power off Auto power off Battery life Battery life Battery life Charging time Charging time Charging time Charging voltage/current Charging voltage/current Charging voltage/current Image storage Image storage Image storage Transportation/storage environment Transportation/storage environment Transportation/storage environment Operating environment Operating environment Operating environment Operating environment Operating altitude Operating altitude Operating altitude Standard accessories Standard accessories

UTi165H User Manual UTi165H User Manual 9. Maintenance Use a wet cloth or weak soap solution to clean the outer shell of the device. Do not use abrasives, isopropyl alcohol or solvents to clean the outer shell, lens or window. 10. Common Emissivity

Material Wood Water Brick Stainless steel Tape Aluminum plate Copper plate Black aluminum Human skin Asphalt PVC Emissivity Emissivity Material Emissivity Emissivity 0.85 Black paper Black paper 0.96 Polycarbonate Polycarbonate 0.75 Concrete Concrete 0.14 Copper oxide Copper oxide 0.96 Cast iron Cast iron 0.09 Rust Rust 0.06 Gypsum Gypsum 0.95 Paint Paint 0.98 Rubber Rubber 0.96 Soil Soil 0.93 0.86 0.86 0.86 0.8 0.8 0.8 0.97 0.97 0.97 0.78 0.78 0.78 0.81 0.81 0.81 0.8 0.8 0.8 0.75 0.75 0.75 0.9 0.9 0.9 0.95 0.95 0.95 0.93 0.93 0.93

Note: This manual can be downloaded from the official website of Uni-Trend (refer to UNI-T Documents Download Operation Guide). UTi165H User Manual UTi165H User Manual