ULVAC TM-2 (01) Image

FREE ENGLISH ULVAC TM-2 (01) PDF USER GUIDE
FREE ENGLISH ULVAC TM-2 (01) PDF USER MANUAL
FREE ENGLISH ULVAC TM-2 (01) PDF OWNER GUIDE
FREE ENGLISH ULVAC TM-2 (01) PDF OWNER MANUAL
FREE ENGLISH ULVAC TM-2 (01) PDF REFERENCE GUIDE
FREE ENGLISH ULVAC TM-2 (01) PDF INSTRUCTION GUIDE
FREE ENGLISH ULVAC TM-2 (01) PDF REFERENCE MANUAL
FREE ENGLISH ULVAC TM-2 (01) PDF INSTRUCTION MANUAL
FREE ENGLISH ULVAC TM-2 (01) PDF OPERATING INSTRUCTIONS


CLICK HERE TO DOWNLOAD ULVAC TM-2 (01) PDF MANUAL

If this is not the document you want for this product, click here to see if we have any other documents for this product.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

What general safety advice is provided for using these optional parts?

This quick start manual is prepared to help users to quickly understand the product’s operating method and display content. Please read the instruction manual beforehand for detailed usage, caution on product use, and safety information to use the pump correctly.


What are the reference tightening torque values?

Bolt Size Tightening Torque (N.m)
M4 1.5
M5 3.0
M6 5.2
M8 12.5
M10 24.5

How do I install the TMX-1 for VD & PVD series?

The TMX-1 for VD & PVD series installation involves the following parts: ① (Component 1), ② (Component 2), ③ (Component 3), ④ (Fastener, x1), ⑤ (Fasteners, x4).

Steps:

1. Assemble parts ①, ②, and ③ in sequence.

2. Secure this assembly using part ④ (x1 fastener).

3. Mount the assembled unit onto the main equipment.

4. Secure the unit to the main equipment using part ⑤ (x4 fasteners).

5. Connect to the pump as indicated in the diagram.


How do I install the TMX-1 for VD & PVD series when removing the baffle?

The installation involves parts: ① (Component 1), ② (Component 2), ④ (Fastener, x1), ⑤ (Fasteners, x4), after removing the baffle (which is part ③ in the standard assembly).

Steps:

1. Remove the baffle (part ③ from the standard TMX-1 assembly).

2. Assemble parts ① and ②.

3. Secure this assembly using part ④ (x1 fastener).

4. Mount the assembled unit onto the main equipment.

5. Secure the unit to the main equipment using part ⑤ (x4 fasteners).

6. Connect to the pump as indicated in the diagram.


How do I install the TMX-1 / TMX-2 for D series?

The installation involves parts: ① (O-ring, may be reused), ② (Adapter plate), ③ (Fasteners, x4).

Steps:

1. Place part ① (O-ring) into the recess on the main equipment. This O-ring may be reused if applicable.

2. Place part ② (adapter plate) over part ①.

3. Secure part ② to the main equipment using part ③ (x4 fasteners).

4. Connect to the pump as indicated in the diagram.


How do I install the TM201 / TM401?

The installation involves parts: ① (Adapter/flange), ② (Fasteners, x4).

Steps:

1. Place part ① (adapter/flange) onto the main equipment.

2. Secure part ① to the main equipment using part ② (x4 fasteners).

3. Connect to the pump as indicated in the diagram.


How do I install the TM-2 for VD-C series?

Parts for TM-2 for VD-C: ① (Top Cap), ② (O-ring), ③ (O-ring), ④ (Lower Flange), ⑤ (M8x35L fasteners, x4), ⑥ (M8x25L fasteners, x4).

Steps:

1. Place O-ring (part ③) onto the groove of the lower flange (part ④).

2. Attach this lower flange assembly (parts ③ and ④) to the bottom of the TM-2 main body.

3. Secure this lower assembly using four M8x25L fasteners (part ⑥).

4. Place O-ring (part ②) onto the groove of the top cap (part ①).

5. Attach this top cap assembly (parts ① and ②) to the top of the TM-2 main body.

6. Secure this top assembly using four M8x35L fasteners (part ⑤).

7. Connect the assembled TM-2 unit to the pump system.


How do I install the TM-2F for VD-C series?

Parts for TM-2F for VD-C: ① (Top Inlet Adapter), ② (O-ring), ③ (Bottom Outlet Adapter), ④ (O-ring), ⑤ (M8x35L fasteners, x4), ⑥ (M8x25L fasteners, x8).

Steps (referencing generic TM-2F installation):

1. Place O-ring (part ④) on the bottom outlet adapter (part ③).

2. Attach this bottom adapter assembly to the lower port of the TM-2F filter body. Secure using four M8x25L fasteners (from part ⑥).

3. Insert the filter element into the TM-2F body.

4. Place O-ring (part ②) on the top inlet adapter (part ①).

5. Attach this top adapter assembly to the upper port of the TM-2F filter body. Secure using four M8x35L fasteners (part ⑤).

6. The remaining four M8x25L fasteners (from part ⑥) are likely for mounting the entire assembled unit or for other connections. Connect the unit into the VD-C system.


How do I install the TM-2 for PKS series?

Parts for TM-2 for PKS: ① (Top Cap), ② (O-ring), ③ (O-ring), ④ (Lower Flange), ⑤ (M8x35L fasteners, x4), ⑥ (M8x25L fasteners, x4).

Steps:

1. Place O-ring (part ③) on the lower flange (part ④).

2. Attach the lower flange assembly (parts ③ and ④) to the bottom of the TM-2 main body.

3. Secure this lower assembly using four M8x25L fasteners (part ⑥).

4. Place O-ring (part ②) on the top cap (part ①).

5. Attach the top cap assembly (parts ① and ②) to the top of the TM-2 main body.

6. Secure this top assembly using four M8x35L fasteners (part ⑤).

7. Connect the assembled TM-2 unit to the pump in the PKS system.


How do I install the TM-2F for PKS series?

Parts for TM-2F for PKS: ① (Top Inlet), ② (O-ring), ③ (Bottom Outlet), ④ (O-ring), ⑤ (M8x35L fasteners, x4), ⑥ (M8x25L fasteners, x4).

Steps:

1. Place O-ring (part ④) on the bottom outlet (part ③).

2. Attach this bottom outlet assembly to the lower port of the TM-2F filter body. Secure using four M8x25L fasteners (part ⑥).

3. Insert the filter element into the TM-2F body.

4. Place O-ring (part ②) on the top inlet (part ①).

5. Attach this top inlet assembly to the upper port of the TM-2F filter body. Secure using four M8x35L fasteners (part ⑤).

6. Connect the assembled TM-2F unit to the pump system for PKS application.


How do I install the TM-3 for VS series?

Parts for TM-3 for VS: ① (Top adapter), ② (O-ring), ③ (O-ring), ④ (Bottom adapter), ⑤ (M8x25L fasteners, x4), ⑥ (M10x30L fasteners, x4).

Steps:

1. Place O-ring (part ③) on the bottom adapter (part ④).

2. Attach this bottom assembly to the lower part of the TM-3 body. Secure using four M10x30L fasteners (part ⑥).

3. Place O-ring (part ②) on the top adapter (part ①).

4. Attach this top assembly to the upper part of the TM-3 body. Secure using four M8x25L fasteners (part ⑤).

5. Connect the assembled TM-3 unit into the VS system, typically to a pump as indicated.


How do I install the TM-3F for VS series?

Parts for TM-3F for VS: ① (Top adapter), ② (O-ring), ③ (Bottom adapter), ④ (O-ring), ⑤ (M8x25L fasteners, x4), ⑥ (M10x30L fasteners, x4), ⑦ (M10x40L fasteners, x4).

Steps:

1. Place O-ring (part ④) on the bottom adapter (part ③).

2. Attach this bottom adapter assembly to the lower port of the TM-3F filter body. Secure using four M10x40L fasteners (part ⑦).

3. Insert the filter element into the TM-3F body.

4. Place O-ring (part ②) on the top adapter (part ①).

5. Attach this top adapter assembly to the upper port of the TM-3F filter body. Secure using four M8x25L fasteners (part ⑤).

6. The M10x30L fasteners (part ⑥, x4) are likely for mounting the entire assembled unit. Connect the unit into the VS system.


How do I install the TM-3 for PKS series?

Parts for TM-3 for PKS: ① (Top adapter), ② (O-ring), ③ (O-ring), ④ (Bottom adapter), ⑤ (M10x30L fasteners, x8).

Steps:

1. Place O-ring (part ③) on the bottom adapter (part ④).

2. Attach this bottom assembly to the lower part of the TM-3 body. Secure using four M10x30L fasteners (from part ⑤).

3. Place O-ring (part ②) on the top adapter (part ①).

4. Attach this top assembly to the upper part of the TM-3 body. Secure using the remaining four M10x30L fasteners (from part ⑤).

5. Connect the assembled TM-3 unit to the pump for PKS application.


How do I install the TM-3F for PKS series?

Parts for TM-3F for PKS: ① (Top adapter), ② (O-ring), ③ (Bottom adapter), ④ (O-ring), ⑤ (M10x30L fasteners, x8), ⑥ (M10x40L fasteners, x4).

Steps:

1. Place O-ring (part ④) on the bottom adapter (part ③).

2. Attach this bottom adapter assembly to the lower port of the TM-3F filter body. Secure using four M10x40L fasteners (part ⑥).

3. Insert the filter element into the TM-3F body.

4. Place O-ring (part ②) on the top adapter (part ①).

5. Attach this top adapter assembly to the upper port of the TM-3F filter body. Secure using four M10x30L fasteners (from part ⑤).

6. The remaining four M10x30L fasteners (from part ⑤) are likely for mounting the entire assembled unit. Connect to the pump for PKS application.


How do I install the TM-4 for VS series?

Parts for TM-4 for VS: ① (Top adapter), ② (O-ring), ③ (O-ring), ④ (Bottom adapter), ⑤ (M8x25L fasteners, x4), ⑥ (M10x30L fasteners, x6).

Steps:

1. Place O-ring (part ③) on the bottom adapter (part ④).

2. Attach this bottom assembly to the lower part of the TM-4 body. Secure using the six M10x30L fasteners (part ⑥).

3. Place O-ring (part ②) on the top adapter (part ①).

4. Attach this top assembly to the upper part of the TM-4 body. Secure using the four M8x25L fasteners (part ⑤).

5. Connect the assembled TM-4 unit into the VS system, typically to a pump as indicated.


How do I install the TM-4F for VS series?

Parts for TM-4F for VS: ① (Top adapter), ② (O-ring), ③ (Bottom adapter), ④ (O-ring), ⑤ (M8x25L fasteners, x6), ⑥ (M10x30L fasteners, x6), ⑦ (M10x40L fasteners, x6).

Steps:

1. Place O-ring (part ④) on the bottom adapter (part ③).

2. Attach this bottom adapter assembly to the lower port of the TM-4F filter body. Secure using the six M10x40L fasteners (part ⑦).

3. Insert the filter element into the TM-4F body.

4. Place O-ring (part ②) on the top adapter (part ①).

5. Attach this top adapter assembly to the upper port of the TM-4F filter body. Secure using the six M8x25L fasteners (part ⑤).

6. The M10x30L fasteners (part ⑥, x6) are likely for mounting the entire assembled unit. Connect the unit into the VS system.


How do I install the TM-4 for PKS series?

Parts for TM-4 for PKS: ① (Top adapter), ② (O-ring), ③ (O-ring), ④ (Bottom adapter), ⑤ (M10x30L fasteners, x16).

Steps:

1. Place O-ring (part ③) on the bottom adapter (part ④).

2. Attach this bottom assembly to the lower part of the TM-4 body. Secure using eight M10x30L fasteners (from part ⑤).

3. Place O-ring (part ②) on the top adapter (part ①).

4. Attach this top assembly to the upper part of the TM-4 body. Secure using the remaining eight M10x30L fasteners (from part ⑤).

5. Connect the assembled TM-4 unit to the pump for PKS application.


How do I install the TM-4F for PKS series?

Parts for TM-4F for PKS: ① (Top adapter), ② (O-ring), ③ (Bottom adapter), ④ (O-ring), ⑤ (M10x30L fasteners, x16), ⑥ (M10x40L fasteners, x8).

Steps:

1. Place O-ring (part ④) on the bottom adapter (part ③).

2. Attach this bottom adapter assembly to the lower port of the TM-4F filter body. Secure using the eight M10x40L fasteners (part ⑥).

3. Insert the filter element into the TM-4F body.

4. Place O-ring (part ②) on the top adapter (part ①).

5. Attach this top adapter assembly to the upper port of the TM-4F filter body. Secure using eight M10x30L fasteners (from part ⑤).

6. The remaining eight M10x30L fasteners (from part ⑤) are likely for mounting the entire assembled unit. Connect to the pump for PKS application.



CLICK HERE TO DOWNLOAD ULVAC TM-2 (01) PDF MANUAL