How do I take a breath test on the SMART START SSI 20-20?

1. When you turn on the vehicle’s ignition, the SMART START SSI 20-20 will activate and the LCD will display WAIT ####. The device is preparing for a test. Take this time to drink WATER to eliminate breath contaminants.

2. Once the unit has initialized, the LCD will display the word BLOW.

3. You can only take a test when the LCD displays the word BLOW.

4. The best way to take a proper test is to blow steadily into the mouthpiece of the unit for approximately 2 seconds and then transition to a hum by saying the word “WHO”. Keep blowing steadily during the transition. During the test the LCD will display the word TEST.

5. Keep blowing into the mouthpiece while humming “WHO” until the unit clicks and the sound of the beep changes to a higher tone to let you know when to stop (approximately 7 seconds).

6. If you do not successfully complete the test, the LCD will display the word ABORT, followed by the reason.

7. After successful completion of the test, the LCD will display the word ANALYZING.

8. The unit will then analyze the breath sample and display PASS, WARN, FAIL, or VIOL.

9. During normal operation of the SMART START SSI 20-20, the LCD will display “*”, indicating engine running.


What are the possible LCD results after taking a test on the SMART START SSI 20-20?

After you take a test, 1 of 5 things will happen:

1. The LCD display will show the word PASS and you may now start your vehicle.

2. The LCD display will show the word WARN and you may now start your vehicle.

3. The LCD display will show the word FAIL and you will not be able to start your vehicle.

4. The LCD display will show the word VIOLATION and you will not be able to start your vehicle.

5. The LCD display will show the word ABORT and you will not be able to start your vehicle.


What should I do if the SMART START SSI 20-20 displays ABORT or FAIL?

When you blow an ABORT or a FAIL, you must take and pass another breath test before your vehicle will start. After blowing a FAIL, the LCD will display FAIL, cycle back to WAIT ## and then BLOW.

ABORT is generally caused by blowing too hard “ABORT HARD”, for not a long enough period of time “ABORT EARLY”, or not performing the voice tone properly “ABORT HUM”. An ABORT will simply require you to take another test.


How do retests work while driving with the SMART START SSI 20-20?

Once your vehicle is started, the SMART START SSI 20-20 will ask for a random retest by beeping and indicating BLOW plus a timer reading. Failure to take these retests is a violation. The retest timer gives you 6 minutes to safely pull over and take the test if you are not comfortable testing while driving. If you fail to take the retest, the unit will indicate “MISSED TEST”. This will result in a lost violation.

The device will ask for RETESTS by beeping and flashing the word BLOW. Be sure to drink WATER prior to each and every test. Failure to take the retest is a violation. When using the device, always practice safe driving habits and keep your eyes on the road. You should find a safe place to park before taking a retest.


How do lockouts work on the SMART START SSI 20-20?

The LCD displays the number of violations left when you press the pound sign and the number three. The counter starts with the maximum available violations and counts down. Each time a violation is registered, the unit will deduct 1 from that number. The SMART START SSI 20-20 will “lockout” and not allow you to take a test under specific conditions involving time limits, service requirements, or violation limits.


What is a 1-15 Minute Lockout on the SMART START SSI 20-20?

A fifteen minute lockout is indicated by an LCD display of FAIL /LOCK ###. This happens when you blow 3 fails in a 15 minute period. The SMART START SSI 20-20 will TEMPORARILY LOCKOUT for ONLY 15 minutes. This can happen before you start your vehicle OR after you start the vehicle and then fail 3 RE-TESTS.

During this 15 minute lockout the device will not allow you to re-test. Use this time to drink water, take some deep breaths and test again when the device resets. NOTE: If this happens while you are driving, the device will not reset until you turn off your vehicle for 15 minutes. A 15 minute Lockout may require you to return for service.


What is a Restricted Drive Time Lockout on the SMART START SSI 20-20?

A drive time lockout is indicated by an LCD display of “RESTRICTED DRIVE TIME”. This only occurs if the unit is programmed with restricted driving times as ordered by the monitoring authority. During the restricted lockout time, the SMART START SSI 20-20 will not allow you to take a test or start your vehicle.


What is a Service Lockout on the SMART START SSI 20-20?

A service lockout is indicated by an LCD display of SRVC / L ###. This is the number of hours remaining before the device shuts down due to missing your service date. Once the SMART START SSI 20-20 displays “LOCK,” it WILL REQUIRE you to call your service provider for an Unlock Code. There may be a charge for this code. DO NOT IGNORE THE SERVICE WARNING grace period.


What is a Violation Lockout on the SMART START SSI 20-20?

A violation lockout is indicated by an LCD display of “LOCKOUT VIOL”. This will occur after you use your last violation AND you exceed the allowed lockout grace period. A violation is caused by a HIGH LEVEL breath failure, OR by missing a re-test, OR by starting the vehicle without passing a test OR by disconnecting the head while the device is turned on. These violations are counted between service visits.

The LCD display will show the number of hours left until the violation lockout occurs (L##). Once the device displays “LOCKOUT VIOL”, it WILL SHUT DOWN and require you to call your service provider for an unlock Code. There may be a charge for this code. DO NOT IGNORE THE LOCKOUT WARNING grace period.


How do Unlock Codes work for the SMART START SSI 20-20?

Remote unlocking is available if you go into lockout and cannot get to a service center. You will be given a code from the corporate office. The code can be entered into the device using the keypad. This code will extend your lockout grace period for no more than six (6) hours. The code is only good ONE TIME and the device will operate as normal. You are required to take and pass a test before starting the vehicle. The code DOES NOT bypass the SMART START SSI 20-20.


What do the LCD displays mean on the SMART START SSI 20-20?

LCD DISPLAYS DESCRIPTION
WAIT ## The unit is preparing for a breath test.
BLOW The unit is ready to accept a breath test.
TEST The unit is accepting the test.
SRVC / L ### A reminder of the number of hours remaining before the unit goes into lockout due to missing your monthly service appointment.
BLOW / VLOCK @ # D ## A reminder of the days remaining before lockout due to violations.
LOCKOUT VIOL The device is in lockout due to violations. You must call to get an unlock code that is only valid for 6 hours.
APPT #### / MM/DD/YY A reminder, your appointment date is approaching. Starts flashing 5 days before your appointment date.
VIOL REMAIN #### The number of violations remaining before the unit goes into the lockout grace period. Press the # sign and the number three (3) on the keypad to see this display.

What are some helpful hints for operating the SMART START SSI 20-20?

You must drink WATER prior to each and every breath test. This will eliminate breath contaminants. Remember, always take a DEEP BREATH immediately before taking a test.

The interlock device has no effect on the engine operation and can not turn your engine off once it is running.

Anyone can drive your vehicle, but they must use the device, and YOU are responsible for all readings recorded by the SMART START SSI 20-20.

If you are the driver of the vehicle, letting someone else take a test for you is a program violation.

If your vehicle needs service, have the service technician call Smart Start for instructions. Keep receipts from the shop indicating the date and time it was in for service as well as the date and time it was picked up.

If you need to replace your battery or starter, keep the receipt of purchase and keep the time between disconnecting the battery and reconnecting it as short as possible.

You have several minutes to respond to a retest. Find a safe place to park before taking a retest. Missing a retest is a violation and will be recorded by the device.

Once the device begins asking for a retest, be sure to take the test before turning off your ignition or you will lose a violation.

When using the device, always practice safe driving habits.

Do not use a breath freshening agent just before taking a test. Most of these agents contain a high level of alcohol.

Place the device where you can see the LCD display. If a Retest is requested and you are driving with the radio playing loud or a window down, you may not hear the Beeping sound that the unit will make. If you can see the LCD display, you will probably notice the retest indication. An optional LED light is available for clients who are hearing impaired.

Do not place the interlock where it is prone to damage: on the floor, under your ashtray, or where you can’t see it or hear it. Also, do not expose the unit to moisture from liquids. You are responsible for damages due to negligence or abuse of the device.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

CLICK HERE TO DOWNLOAD SMART START SSI 20-20 (01) PDF DOCUMENT


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.