SICK PL560DG-H (01) Image

FREE ENGLISH SICK PL560DG-H (01) PDF DOCUMENT.
FREE ENGLISH SICK PL560DG-H (01) PDF USER GUIDE.
FREE ENGLISH SICK PL560DG-H (01) PDF USER MANUAL.
FREE ENGLISH SICK PL560DG-H (01) PDF OWNER GUIDE.
FREE ENGLISH SICK PL560DG-H (01) PDF OWNER MANUAL.
FREE ENGLISH SICK PL560DG-H (01) PDF REFERENCE GUIDE.
FREE ENGLISH SICK PL560DG-H (01) PDF INSTRUCTION GUIDE.
FREE ENGLISH SICK PL560DG-H (01) PDF REFERENCE MANUAL.
FREE ENGLISH SICK PL560DG-H (01) PDF INSTRUCTION MANUAL.
FREE ENGLISH SICK PL560DG-H (01) PDF OPERATING INSTRUCTIONS.


CLICK HERE TO DOWNLOAD SICK PL560DG-H (01) PDF DOCUMENT

If this is not the document you want for this product, click here to see if we have any other documents for this product.

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

What is the correct use of the SICK PL560DG-H heated reflector?

The SICK PL560DG-H heated reflector is an accessory for SICK distance sensors. It is intended for reflecting the laser beam from a distance sensor. In addition, you must observe the provided instructions and technical specifications.

Misuse

Different or additional use is considered to be improper use. SICK AG shall not be held liable for personal injury and damage to property resulting from this.

About this document and other relevant documents

The mounting instructions describe the installation and electrical connection of the heated reflector. For all work involving the distance sensor, refer to the respective distance sensor operating instructions.


What are the primary safety instructions for working with the SICK PL560DG-H?

Carefully read through the instruction manual before performing any work. The instructions are considered a part of the reflector and must be kept in an accessible location in the immediate vicinity of the reflector at all times.

Observe the distance sensor operating instructions, with particular attention on the safety notices and warnings listed.

Only electrically qualified personnel may mount the reflector, establish the electrical connections or put the reflector into operation.

Switch off the supply voltage for the reflector during all work.

Only mount and operate undamaged reflectors. Check the insulation of the heating element and the connecting cable before installation and before establishing any electrical connections.


What safety precautions are specific to the SICK PL560DG-H reflector itself?

Protect the reflector from mechanical stress such as impacts and vibrations.

Do not expose the reflector to any chemical stress or corrosive media such as solvents.

Installation in a corrosive environment is prohibited.


How should the SICK PL560DG-H be transported and stored?

The reflector must be transported and stored in its original packaging.

Store the reflector in a dry, dust-free location free of vibrations.

Storage temperature: -40 °C to +55 °C


What is included in the scope of delivery for the SICK PL560DG-H?

The scope of delivery includes the reflector, 4 spacer sleeves and these mounting instructions.


What are the mounting requirements for the SICK PL560DG-H?

CAUTION: Falling reflector! An improperly mounted reflector can fall and cause injuries.

Mount the reflector at a location free of shocks and vibrations.

The mounting location and mounting material must be suitable for mounting the reflector.

The mounting location has to be designed for the weight of the reflector.

Observe the specified distances, pitch in relation to the laser beam axis and mounting position relative to the distance sensor. See the relevant distance sensor operating instructions.

Protect the rear side of the reflector from direct sunlight.

Maintain a minimum clearance of at least 2 mm between support and protecting insulation of the reflector.

Protect the rear side of the reflector against ingress and mechanical damage.


How do I mount the SICK PL560DG-H?

1. Carefully unpack the reflector.

2. Carefully mount the reflector.

• Observe the dimensions. See the technical specifications for details.

• Use the spacer sleeves provided as spacers for the mounting location.

• Set the pitch using washers.


What are the electrical installation warnings for the SICK PL560DG-H?

WARNING: Electrical voltage!

Electrical voltage can cause severe injury or death.

Work on electrical systems must only be performed by qualified electricians.

Only connect the reflector while the supply voltage is switched off. Ensure power supply is not connected.

Provide separate fuse protection for the reflector and supply cable.

Only establish the electrical connections if the reflector is undamaged. Check the insulation of the heating element and the connecting cable before installation and before establishing any electrical connections.

National and regional regulations must be complied with.

Safety requirements relating to work on electrical systems must be complied with.


How do I establish the electrical connection for the SICK PL560DG-H?

1. Route the connecting cable securely in place and provide strain relief. While doing so, ensure that the connecting cable is protected from mechanical stress such as tension, compression, excessive bending or repeated bending.

2. Connect the connecting cable to the supply voltage.


How do I commission the SICK PL560DG-H?

For commissioning, refer to the relevant distance sensor operating instructions.


How do I clean and maintain the SICK PL560DG-H?

Proper functionality of the distance sensor requires keeping the reflector clean.

NOTE: Potential damage to the reflector! Improper cleaning can damage the reflector.

Do not use any corrosive cleaning agents or cleaning agents containing abrasives.

Do not use paint thinner.

Do not clean with a high-pressure washer or steam cleaner.

Cleaning the reflector

1. Clean the reflector at regular intervals using a soft, lint-free cloth or sponge. Use conventional dishwashing detergent at the specified concentration as the cleaning agent.

2. Rinse the reflector with clean water.

3. Dry the surface.


How should the SICK PL560DG-H be disassembled and disposed of?

The reflector should be disposed of in an environmentally-friendly way in accordance with applicable national regulations governing waste disposal.

SICK AG is not currently able to take back devices that can no longer be used.


What are the technical specifications for the SICK PL560DG-H?

For the technical data for the distance sensor, refer to the relevant operating instructions.

Specification PL560DG-H
Part number 1023888
Reflector film Diamond grade
Reflection area 605 mm x 605 mm
Baseplate material Anodized aluminum
Dimensions 665 mm x 665 mm
Weight Approx. 7.3 kg
Supply voltage 90 V to 280 V AC
Heat output at 230 V AC 900 W
Electrical connection (connecting cable) 2 m silicone cable, 3 x 0.75 mm², flexible cable, open end with ferrules
Minimum bend radius 51 mm at room temperature
External fuse protection 6 A, provided by customer
Electrical protection class I
Enclosure rating IP X4 acc. to EN 60529
Ambient temperature • Storage: -40 °C to +55 °C
• Operation: -40 °C to +55 °C

What are the dimensions of the SICK PL560DG-H?

The dimensions for the SICK PL560DG-H are as follows:

• Overall dimensions (width x height): 629 mm (24.76 inch) x 665 mm (26.18 inch)

• Reflective surface area: 600 mm (23.62 inch) x 629 mm (24.76 inch)

• Depth: 44 mm (1.73 inch)

• Mounting holes: Ø 6.5 mm (0.26 inch), 4 holes


CLICK HERE TO DOWNLOAD SICK PL560DG-H (01) PDF DOCUMENT


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.