SERENELIFE SLPAC14 (01) Image

FREE ENGLISH SERENELIFE SLPAC14 (01) PDF USER GUIDE
FREE ENGLISH SERENELIFE SLPAC14 (01) PDF USER MANUAL
FREE ENGLISH SERENELIFE SLPAC14 (01) PDF OWNER GUIDE
FREE ENGLISH SERENELIFE SLPAC14 (01) PDF OWNER MANUAL
FREE ENGLISH SERENELIFE SLPAC14 (01) PDF REFERENCE GUIDE
FREE ENGLISH SERENELIFE SLPAC14 (01) PDF INSTRUCTION GUIDE
FREE ENGLISH SERENELIFE SLPAC14 (01) PDF REFERENCE MANUAL
FREE ENGLISH SERENELIFE SLPAC14 (01) PDF INSTRUCTION MANUAL
FREE ENGLISH SERENELIFE SLPAC14 (01) PDF OPERATING INSTRUCTIONS


CLICK HERE TO DOWNLOAD SERENELIFE SLPAC14 (01) PDF MANUAL

If this is not the document you want for this product, click here to see if we have any other documents for this product.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

What is the California Proposition 65 warning for the SERENELIFE SLPAC14?

This product contains Acrylonitrile which is known to the state of California to cause cancer birth defects and other reproductive harm. Do not ingest.


What are the main features of the SERENELIFE SLPAC14 portable air conditioner?

Dehumidification: Removes up to 50 pints of moisture per 24 hours, with a Continuous Drain Option for extended, unattended use.

Self-Evaporation Technology: Helps reduce water drainage requirements.

Safety: Metal control box to prevent fire or explosion risks.

Compressor: Rotary compressor for efficient cooling.

Portability: Universal castors allow easy movement.

Wifi Function: Supports remote control for convenient operation.

Modes: 3 operational modes-Cooling, Dehumidifier, and Fan.

Energy-Efficient: Low power consumption and low noise motor (57 dBA).

User-Friendly: Features push-button controls with an LED display for easy adjustments of temperature, fan speed, and timer settings.


What items are included in the box with the SERENELIFE SLPAC14?

AC Unit

Exhaust Hose

Window Installation Plate

Remote Control


What are the technical specifications of the SERENELIFE SLPAC14?

Power Supply: 115V / 60Hz

Rated Power: 1220W

Refrigerant Type: R32

Cooling Capacity:

ASHRAE: 14,000 Btu/h

DOE: 10,000 Btu/h

Coverage Area: Up to 500 sq. ft.

Air Flow: 400 cubic meters per hour

Moisture Removal (Dehumidifier): 1.5 liters per hour

Fan Speed: Low, Medium, and High settings

Temperature Display: Switchable between °C / °F

Timer: Adjustable up to 24 hours

Noise Level: 57 dBA

Exhaust Hose Max Length: 59 inches

Window Kit: Adjustable from 26.6 to 49.7 inches

Product Dimensions: L x W x H: 32″ x 18.5″ x 15.4″


What are the important safety requirements for using the SERENELIFE SLPAC14?

The SERENELIFE SLPAC14 uses a flammable refrigerant (R32) and must be installed, operated, and stored in a room with a floor area larger than 43 square feet. Always read and follow all safety messages.

Requirements:

Place the unit on a flat, dry surface.

Keep the air conditioner at least 20 inches (50 cm) away from surrounding objects.

Ensure the power supply complies with safety specifications, includes proper grounding, and is securely connected.

After installation, ensure the plug is intact and firmly inserted into the socket.

Keep the air inlet and outlet unobstructed.

If the power cord is damaged, it must be replaced by qualified personnel from the manufacturer’s maintenance department or a similar authorized service center.

Keep the unit away from flammable materials such as gasoline, stoves, or other heat sources.

Arrange wires neatly to avoid tripping hazards or accidental disconnection.

Turn off the unit and unplug it immediately if the power cord is damaged. Seek professional maintenance assistance promptly.

This appliance can be operated by children aged 8 years and above, or individuals with reduced physical, sensory, or mental capabilities, only under proper supervision or instruction regarding safe usage and potential hazards.

Children must not play with the appliance. Cleaning and maintenance must not be performed by children without supervision.


What are the prohibitions when using the SERENELIFE SLPAC14?

This air conditioner is for household use only and should not be used for other purposes.

Do not install the unit in damp areas, such as laundry rooms or locations with excessive moisture.

Avoid turning the unit on or off by plugging or unplugging the power cord.

Do not place objects on the unit or insert items into the air inlet or outlet.

Do not use insecticides, flammable sprays, or other hazardous substances near the air conditioner.

Do not allow oil or water to come into contact with the unit.

Clean the unit with a semi-damp, soft cloth only. Do not use water, benzene, gasoline, alcohol, or chemical solvents. If cleaning is needed, use a neutral detergent.


What are the suggestions for optimal operation of the SERENELIFE SLPAC14?

Cooling mode: Do not use the unit if the ambient temperature exceeds 104°F (40°C).

Heating mode: Do not use the unit if the ambient temperature is below 44.6°F (7°C).


What are the parts of the SERENELIFE SLPAC14?

1. Control Panel

2. Wind Guide Bar

3. Exhaust Hose Assembly

4. Casters

5. Handle

6. Air Intake Grille

7. Power Cord

8. Filter

9. Air Outlet

10. Power Cord Buckle

11. Drainage Outlet


How do I use the control panel on the SERENELIFE SLPAC14?

After shutting down the unit in cooling or heating mode, wait at least 3 minutes before restarting.

Buttons and Display:

POWER: Turns the unit ON or OFF.

MODE: Selects Cool, Fan, or Dry mode. Indicator lights display the selected mode.

UP/DOWN:

Adjusts the temperature in Cool mode.

Adjusts the timer in Timing mode.

Press UP and DOWN simultaneously to switch between Fahrenheit (°F) and Celsius (°C).

SPEED: Adjusts fan speed (Low, Medium, High). The corresponding indicator light will illuminate.

TIMER: Activates the timer setting mode.

88 DISPLAY:

In Cool mode: Displays the set temperature.

In Fan and Dry modes: Displays the room temperature.

“°C” indicates Celsius, and “°F” indicates Fahrenheit.


How do I operate the SERENELIFE SLPAC14 using the remote control?

POWER: Turns the unit ON or OFF.

MODE: Selects Cool, Fan, or Dry mode.

UP/DOWN: Adjusts temperature and timer settings.

FAN: Adjusts fan speed (Low, Medium, High).

TIMER: Sets the timer.

SWING: Controls the air outlet’s oscillation.

°C/°F: Toggles between Celsius and Fahrenheit.


What are the protection functions of the SERENELIFE SLPAC14?

1. Frost Protection Function:

In Cool, Dry, or Energy-Saving modes, the unit will enter protection mode if the exhaust pipe temperature drops too low. It will resume normal operation once the temperature stabilizes.

2. Full Water Protection Function:

If water in the tray exceeds the warning level, the unit will sound an alarm, and the display will show “FL.”

To resolve this, connect a drainage pipe to the outlet and empty the water into a drainage area. Once emptied, the unit will resume normal operation.

3. Compressor Protection Function:

To protect the compressor’s lifespan, there is a 3-minute delay before restarting after the compressor is shut down.


How do I set the timer on the SERENELIFE SLPAC14?

Setting the Timer for Shutdown:

1. While the machine is running, press the Timer key. The timer LED will light up, and the “88” display will flash “0” for five seconds.

2. During this time, press the Up or Down keys to adjust the shutdown time from 1 hour to 24 hours. Each press increases or decreases the time by 1 hour.

3. Once the set time is reached, the machine will shut down automatically.

Setting the Timer for Start-Up:

1. While the machine is in standby mode, press the Timer key. The timer LED will light up, and the “88” display will flash “0” for five seconds.

2. Use the Up or Down keys to adjust the start-up time, following the same procedure as for the shutdown timer.

3. You can also select the working mode (cooling, heating, etc.) and adjust the temperature if applicable. Once the set time is reached, the machine will start automatically and operate in the selected mode.

Changing the Timer Setting:

1. While the timer is active, press the Timer key to display the remaining time. The “88” display will flash.

2. During this time, press the Up or Down keys to adjust the remaining time.

3. If you press the Timer key again while the display is flashing, the timer setting will be canceled.


How do I operate the different modes on the SERENELIFE SLPAC14?

1. Cool Mode:

Press the Mode key to select Cool Mode. The corresponding LED will light up.

Adjust the temperature using the Up or Down keys. The temperature can be set between 60°F and 86°F (16°C and 30°C).

Use the Fan Speed key to select the desired fan speed (Low, Medium, or High).

To enable Sleep Mode, press and hold the Up and Timer keys simultaneously. This forces both fans to operate at low speed. Press the same key combination again or change the mode to cancel Sleep Mode.

2. Dry Mode:

Press the Mode key to select Dry Mode. The corresponding indicator light will turn on. Note: The temperature and fan speed cannot be adjusted in Dry Mode.

3. Fan Mode:

Press the Mode key to select Fan Mode. The corresponding indicator light will turn on.

Use the Fan Speed key to select the desired fan speed (Low, Medium, or High). Note: The temperature cannot be adjusted in Fan Mode.

Important Notes:

1. If the Full Water indicator is displayed, the machine will stop working. Drain the water before restarting the machine.

2. The exhaust duct is not required when using Dry Mode or Fan Mode.

3. If your room is exposed to direct sunlight, close the curtains for optimal cooling performance.


How do I install the SERENELIFE SLPAC14?

1. Selecting the Installation Location:

Install the machine on a flat, dry surface.

Ensure at least 20 inches (50 cm) of clearance around the machine for proper airflow.

The optimal installation distance is 20 inches (50 cm) from the back of the machine to the wall and 36 inches (90 cm) from the air outlet to the floor.

2. Assembly Method of Exhaust Pipe:

a. Connect the Exhaust Pipe Assembly: Attach the exhaust pipe to the round joint.

b. Attach to the Machine: Fix the circular end of the exhaust pipe assembly to the air outlet of the machine.

c. Connect to the Window Sealing Plate: Secure one end of the oblate joint on the exhaust pipe assembly to the window sealing plate.

d. Install the Window Seal: Fit the window seal to the nearest window. Ensure there are no obstacles within 20 inches (50 cm) outside the window to allow smooth exhaust flow.

Important Notes: The length of the exhaust duct should be between 24 inches (60 cm) and 67 inches (170 cm), including the adapter. It is recommended to use the shortest possible length to optimize energy efficiency. The exhaust duct is specifically designed for this air conditioner model; do not use exhaust pipes of different lengths or materials.

3. Installation of Window Sealing Plate:

a. Measure the Window Size: Accurately measure the width or height of your window.

b. Adjust the Window Sealing Plate: Extend or shorten the sealing plate to match the measured window size.

c. Secure the Sealing Plate: Once the length is adjusted, secure the sealing plate using the provided screws to fix it in place.

d. Secure the Sealing Plate to the Window: Install the adjusted and fixed window sealing plate onto the window frame. Ensure it is positioned firmly and securely.

e. Attach the Exhaust Pipe Assembly: Connect the flat end of the exhaust nozzle to the window sealing plate assembly. Use screws to fix the exhaust pipe assembly securely to the sealing plate for a tight connection.


How do I drain water from the SERENELIFE SLPAC14?

During refrigeration or drying mode in humid conditions, the unit may produce excess condensed water. When the water level in the water tray reaches a certain limit, the unit will activate a full water alarm, stop the compressor, and display a “Full Water” indicator on the control panel. An alarm will sound until the water level drops or is manually drained.

How to Drain Water:

1. When the full water alarm is triggered, promptly drain the water.

2. Move the unit to an area where you can safely drain water (e.g., a toilet or sewer).

3. Unscrew the nut on the drainage outlet and remove the water plug.

4. Allow the water to fully drain.

5. Reinstall the water plug and nut securely before using the unit again.

Note: When moving the machine to drain water, handle it carefully to prevent water spillage from inside the unit.


How do I clean and maintain the SERENELIFE SLPAC14?

Important: Before cleaning, ensure the unit is turned off and unplugged from the power source.

1. Cleaning the Surface:

Wipe the exterior of the unit with a duster or a soft, damp cloth. Avoid using harsh chemical agents such as benzene, alcohol, or gasoline.

2. Cleaning the Filter Screen:

A blocked filter can impede air circulation and reduce efficiency. It is recommended to clean the filter every two weeks during long-term use.

Steps to Clean the Filter:

1. Remove the Filter: Pull out the filter.

2. Clean the Filter: Submerge the filter in warm water (approximately 40°C/104°F) mixed with a neutral detergent. Gently clean the filter to remove dust and debris.

3. Dry the Filter: Allow the filter to dry completely in a shaded area. Avoid direct sunlight to prevent damage.


How should I store the SERENELIFE SLPAC14 after the cooling season?

1. Drain Water:

Fully drain the water from the internal water tray through the drain outlet. During drainage, tilt the unit backward slowly to ensure all water is removed.

2. Dry the Unit:

Set the air conditioner to Air Supply Mode.

Press and hold the Wind Speed button for 5 seconds until the downdraft fan begins working.

Let the unit operate in this mode for 2-3 hours to dry the internal components and prevent mildew growth.

3. Power Off and Store Components:

Turn off the unit and unplug the power cord.

Wrap the cord neatly and secure it in place.

Detach the exhaust pipe and store it safely.

4. Protect and Store the Unit:

Cover the air conditioner with a plastic bag to protect it from dust.

Place the unit in a dry location.

5. Remove the Remote Control Batteries:

Remove the batteries from the remote control to prevent leakage. Store them in a cool, dry place.


How do I set up the Wi-Fi connection for the SERENELIFE SLPAC14?

Download and Install the App:

Search for “Smart Life” in your device’s application store to download and install the app.

Registration:

1. If you don’t have an account, register a new one. Open the app and tap to navigate to the Registration Page.

2. The system will automatically detect your country/area, or you can manually select it.

3. Enter your mobile phone number or email address and tap Next.

4. For Mobile Number: Enter the verification code sent via SMS, set a password, and tap Confirm.

5. For Email: Enter a password and tap Confirm to finish registration.

Connect Device:

1. Plug in the SERENELIFE SLPAC14; it will enter Standby Mode. Do not turn on the unit until the Wi-Fi connection is successful.

2. Press and hold the SPEED button for 3 seconds to enter Wi-Fi connection mode. The SPEED button also serves as the reset button.

3. Open the app, tap the “+” icon in the upper-right corner.

4. There are two connection methods: Normal Mode (default, indicator light flashes rapidly) and AP Mode (indicator light flashes slowly). Tap the top-right corner of the page to switch between modes.

For Normal Mode (rapidly flashing light):

1. Ensure the device’s indicator light is flashing rapidly (2 times per second) and tap to proceed.

2. Select the 2.4G Wi-Fi network, enter the password, and tap Confirm to start connecting.

For AP Mode (slowly flashing light):

1. Ensure the device’s indicator light is flashing slowly (1 time every 3 seconds) and tap to proceed.

2. Select the Wi-Fi network, enter the password, and tap Confirm.

3. After connecting with the hotspot, return to the network connection page to continue the connection process.

Once the network connection is successful, the app will display a success screen. If it fails, you can try connecting again or view help for troubleshooting.


How do I control the SERENELIFE SLPAC14 using the Smart Life app?

After successfully configuring the device, the SERENELIFE SLPAC14 will appear on the app’s home page. Tap it to enter its control page.

Note:

When the device is online, it supports shortcut operations.

When the device is offline, it will display “Offline” but can still be controlled.

Smart Life Scenario:

The app allows the device to perform actions based on various conditions, including:

Temperature, Humidity, Weather, PM2.5, Air quality, Sunrise & sunset times, and other Device actions (e.g., turn on/off).


How do I connect the SERENELIFE SLPAC14 to Amazon Echo (Alexa)?

1. Prerequisites:

A stable Wi-Fi network that can access Amazon’s server.

An Echo device (e.g., Echo, Echo Tap, or Echo Dot).

An Amazon account.

The Smart Life app with an associated account.

Your SERENELIFE SLPAC14 already added to your Smart Life app with an easily recognizable name (e.g., “Bedroom Air Conditioner”).

2. Set Up Echo with Alexa App (if not already done):

Make sure your Echo device is powered on.

Open the Alexa app and sign in.

Tap the hamburger menu in the top left, select “Settings,” then “SET UP A NEW DEVICE.”

Select your Echo model, choose the language, and tap “CONNECT TO WI-FI.”

Follow the on-screen instructions to connect your Echo to your Wi-Fi network.

3. Link Smart Life Account to Alexa:

In the Alexa app, tap the hamburger menu and select “Skills & Games.”

Search for “Smart Life.”

Select “Smart Life” and tap “ENABLE TO USE” to enable the skill.

You will be redirected to the account link page. Enter your Smart Life account and password, ensuring the country/region is correct. Tap “Link Now.”

4. Discover Devices:

Echo needs to discover your smart devices. Say, “Alexa, discover devices.”

Alternatively, in the Alexa app, go to the Smart Home section and tap “DISCOVER.”

Echo will discover devices already added in the Smart Life app. Discovered devices will appear in the list.

5. Control Devices by Voice Commands:

Once discovered, you can control your SERENELIFE SLPAC14 with voice commands, such as:

“Alexa, turn on/off bedroom air conditioner.”

“Alexa, set bedroom air conditioner to 70 degrees.”

“Alexa, increase/decrease the temperature.”

Note: Every time you change a device’s name in the Smart Life app, Echo must re-discover the device before you can control it.


What should I do if the SERENELIFE SLPAC14 has an abnormal condition?

In case of the following abnormal conditions, turn off the air conditioner and pull out the plug, then contact a professional electrician:

The fuse often breaks.

The power cord is damaged or the skin of the cord is exposed.

The body produces an abnormal odor.


What do the error codes on the SERENELIFE SLPAC14 mean?

Error-detecting code Multi-functional defection
E1 Coil sensor sensing abnormal
E2 Abnormal perception of room temperature sensor
E4 Anti-freezing protection
FL The machine is in full water alarm state

How can I troubleshoot common issues with the SERENELIFE SLPAC14?

Before contacting a professional electrician, check the following:

TROUBLE CAUSE SOLUTION
The air conditioner doesn’t work Is the power off?
Is the plug not inserted?
Is the fuse blown or closed?
Is the time setting appropriate?
Is there a full water warning?
Normal phenomenon.
Plug in the power plug.
Replace the fuse or turn on the power.
Change the time setting.
Pour out the water.
The air conditioner is not cooling Is the air inlet and outlet blocked?
Is there any other heating source in the room?
Is the filter too dirty?
Is the temperature setting appropriate?
Is the fan speed set to the lowest gear?
Remove the blockage.
Remove other heat sources.
Clean the filter screen.
Change the temperature.
Choose the right wind speed.
The air conditioner is not standing securely, too much noise, and shaking while running Is the fuselage tilted?
Is the ground uneven?
Put it on the ground.
Ensure it’s placed on an even surface.

CLICK HERE TO DOWNLOAD SERENELIFE SLPAC14 (01) PDF MANUAL


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.