What are the general safety precautions when operating the SCHEPPACH HC550TC 400V compressor?
When using electric tools, the following basic safety measures must be observed for protection against electric shock, and the risk of injury and fire for the SCHEPPACH HC550TC 400V compressor. Read all these notices before using the power tool and store the safety instructions well for later reference. (GB)
- Keep the work area orderly. Disorder in the work area can lead to accidents. (GB)
- Take environmental influences into account. Do not expose power tools to rain. Do not use electric tools in a damp or wet environment. There is a risk of electric shock! Make sure that the work area is well-illuminated. Do not use power tools where there is a risk of fire or explosion. (GB)
- Protect yourself from electric shock. Avoid physical contact with earthed parts (e. g. pipes, radiators, electric ranges, cooling units). (GB)
- Keep away from children! Do not allow other persons to touch the tool and cable, keep them away from your work area. (GB)
- Securely store unused power tools. Unused power tools should be stored in a dry, elevated or closed location out of the reach of children. (GB)
- Do not overload your power tool. They work better and more safely in the specified output range. (GB)
- Wear suitable clothing. Do not wear wide clothing or jewellery, which can become entangled in moving parts. Rubber gloves and anti-slip footwear are recommended when working outdoors. Tie long hair back in a hair net. (GB)
- Do not use the cable for purposes for which it is not intended. Do not use the cable to pull the plug out of the outlet. Protect the cable from heat, oil and sharp edges. (GB)
- Take care of your tools. Keep your compressor clean in order to work well and safely. Follow the maintenance instructions. Check the connection cable of the electric tool regularly and have it replaced by a recognised specialist when damaged. Check extension cables regularly and replace them when damaged. (GB)
- Pull the connector out of the socket when the power tool is not in use or prior to maintenance and when replacing tools such as saw blades, drills, cutters. (GB)
- Avoid inadvertent starting. Make sure that the switch is switched off when plugging the plug into an outlet. (GB)
- Use extension cables for outdoors. Only use approved and appropriately identified extension cables for use outdoors. Only use cable reels in the unrolled state. (GB)
- Always remain attentive. Pay attention to what you are doing. Remain sensible when working. Do not use the power tool when you are distracted. (GB)
- Check the power tool for potential damage. Protective devices or other parts with minor damage must be carefully inspected to ensure that they function correctly and as intended prior to continued use of the power tool. Check whether the moving parts function faultlessly and do not jam or whether parts are damaged. All parts must be correctly mounted and all conditions must be fulfilled to ensure fault free operation of the power tool. Damaged protective devices and parts must be properly repaired or replaced by a recognised specialist workshop, insofar as nothing different is specified in the operating manual. Damaged switches must be replaced at a customer service workshop. Do not use any faulty or damaged connection cables. Do not use any power tool on which the switch cannot be switched on and off. (GB)
- Have your power tool repaired by a qualified electrician. This power tool conforms to the applicable safety regulations. Repairs may only be performed by an electrician using original spare parts. Otherwise accidents can occur. (GB)
- Attention! For your own safety, only use accessories and additional equipment that are indicated in the operating manual or have been recommended or indicated by the manufacturer. Use of other tools or accessories that those recommended in the operating manual or in the catalogue could represent a personal danger to you. (GB)
- Noise. Wear hearing protection when using the compressor. (GB)
- Replacing the connection line. If the connection line is damaged, it must be replaced by the manufacturer or an electrician to avoid danger. There is a risk of electric shock. (GB)
- Inflating tyres. Check the tyre pressure immediately after filling using a suitable pressure gauge, e.g. at a petrol station. (GB)
- Street-legal compressors in construction site operation. Ensure that all hoses and fixtures are suitable for the maximum permissible working pressure of the compressor. (GB)
- Set-up location. Only set up the compressor on a flat surface. (GB)
- In case of pressures above 7 bar, it is recommended to equip supply hoses with a safety cable (e. g. a wire rope). (GB)
- Avoid over-stressing the piping system by using flexible hose connections to prevent kinking. (GB)
- Make sure that the oil cooling devices are kept clean and that the protective devices are kept in good operating condition. (GB)
- Risk of burns from hot oil. Wear suitable protective gloves. Never work with the compressor near naked flames. Be careful not to spill oil. (GB)
- Starting the motor is forbidden if the temperature is below 0°C. (GB)
What is the intended use for the SCHEPPACH HC550TC 400V compressor?
The compressor is used to generate compressed air for pneumatically powered tools that can be operated with an air rate of up to 350 l/min. (e.g. tyre inflaters, air blow guns, paint spray guns). (GB)
The compressor may only be operated in a dry and well ventilated indoor space. (GB)
What are the safety instructions for working with compressed air and air blow guns when using the SCHEPPACH HC550TC 400V compressor?
Safety instructions for working with compressed air and air blow guns for the SCHEPPACH HC550TC 400V compressor:
- Ensure there is sufficient distance to the product, at least 2.50 m, and keep the compressed air tools / compressed air attachments away from the compressor during operation. (GB)
- Compressor pump and lines reach high temperatures during operation. Touching them will cause burns. (GB)
- The air which is sucked in by the compressor must be kept free of impurities that could cause fires or explosions in the compressor pump. (GB)
- When disconnecting the hose coupling, hold the coupling piece of the hose firmly with your hand. This will ensure that you avoid injuries caused by the hose recoiling. (GB)
- Wear safety goggles and a respirator when working with the compressed air pistol. Dusts are harmful to health! Foreign objects or blown off parts can easily cause injuries. (GB)
- Do not blow on people or clean clothing whilst on the body with the air blow gun. Danger of injury! (GB)
What are the safety instructions when using spraying attachments (e.g. paint sprayers) with the SCHEPPACH HC550TC 400V compressor?
Safety instructions when using spraying attachments (e.g. paint sprayers) for the SCHEPPACH HC550TC 400V compressor:
- Keep the spray attachment away from the compressor when filling so that no liquid comes into contact with the compressor. (GB)
- Never spray in the direction of the compressor when using the spraying attachments (e.g. paint sprayers). Moisture can lead to electrical hazards! (GB)
- Do not process any paints or solvents with a flash point below 55° C. Risk of explosion! (GB)
- Do not heat up paints or solvents. Risk of explosion! (GB)
- If harmful liquids are processed, filter devices (face masks) are required for protection. Also observe the information on protective measures provided by the manufacturers of such substances. (GB)
- The information and labelling of the hazardous substances ordinance affixed to the outer packaging of the processed materials must be observed. If necessary, take additional protective measures, in particular wear suitable clothing and masks. (GB)
- Do not smoke during the spraying process or in the working area. Risk of explosion! Paint vapours are also highly flammable. (GB)
- Fireplaces, naked flames lights or sparking machinery must not be present or operated. (GB)
- Do not store or consume food or drinks in the work area. Paint fumes are harmful to health. (GB)
- The working area must be larger than 30 m³ and sufficient air exchange must be ensured during spraying and drying. (GB)
- Do not spray into the wind. Always observe the regulations of the local police authorities when spraying flammable or hazardous spraying materials. (GB)
- Do not use media such as white spirit, butyl alcohol and methylene chloride in conjunction with the PVC pressure hose. These media destroy the pressure hose. (GB)
- The work area must be separated from the compressor so that it cannot come into direct contact with the working medium. (GB)
What steps should be taken for the operation of pressure vessels with the SCHEPPACH HC550TC 400V compressor?
Operation of pressure vessels for the SCHEPPACH HC550TC 400V compressor:
- Anyone who operates a pressure vessel must keep this in good working order, operate and monitor it correctly, perform the necessary maintenance and servicing works immediately and implement safety measures as required according to the circumstances. (GB)
- The regulatory authority can instruct necessary monitoring measures in individual cases. (GB)
- A pressure vessel must not be operated if it exhibits a defect that poses a danger to personnel or third parties. (GB)
- Check the pressure vessel for rust and damage each time before use. The compressor shall not be operated if the pressure vessel is damaged or rusty. If you discover damage, please contact the customer service workshop. (GB)
How should the SCHEPPACH HC550TC 400V compressor be assembled?
To assemble the SCHEPPACH HC550TC 400V compressor, you require the following tools:
- Open-ended spanner 12 mm (not included in the scope of delivery). (GB)
- Open-ended spanner 14 mm (not included in the scope of delivery). (GB)
- Open-ended spanner 17 mm (not included in the scope of delivery). (GB)
- Open-ended spanner 4 mm (not included in the scope of delivery). (GB)
- Phillips screwdriver (not included in the scope of delivery). (GB)
Fitting the wheels (Fig. C):
Insert the screw (23) through the wheel (14). Now insert the screw (23) through the mount on the pressure vessel (12). Now insert the screw (23) with the nut (24). Repeat the process on the other side of the pressure vessel (12). (GB)
Fitting the foot (2x) (Fig. D):
Insert the screw (25) through the foot (13). The foot (13) is subsequently fitted on the mount on the pressure vessel (12). Fasten the foot (13) with the nut (26). Repeat the process for the second foot. (GB)
Fitting the air filter (3x) (Fig. E):
Remove the transport protection from the air filter mount (if applicable). Remove the wing nut (27) from the threaded pin on the compressor pump. Fit the air filter housing (1) with the paper filter on the threaded pin. Now refasten the air filter housing (1) with the wing nut (27). Repeat the process with all air filters. Fasten the air filter with the inlet opening facing downwards, to avoid excessive contamination. (GB)
Fitting the transport handle (Fig. F):
Fasten the transport handle (6) to the pressure vessel (12) with the screw (29) as shown. Repeat this process three times. (GB)
How do I perform the initial setup, including adding oil, to the SCHEPPACH HC550TC 400V compressor before commissioning?
Before connecting the SCHEPPACH HC550TC 400V compressor to the machine, make certain that the data on the type plate matches with the mains power data. (GB)
Fill the compressor pump housing with oil as described in point 9.5. (GB)
Check the device for transport damage. Report any damage immediately to the transport company which was used to deliver the compressor. (GB)
Install the compressor near the point of consumption. (GB)
Long air lines and supply cables (extension cable) should be avoided. (GB)
Ensure that the intake air is dry and dust-free. (GB)
Do not deploy the SCHEPPACH HC550TC 400V compressor in damp or wet areas. (GB)
Operate the compressor only in suitable areas (well ventilated, ambient temperature +5°C to 40°C). There must be no dust, acids, vapours, explosive gases or inflammable gases in the room. (GB)
The compressor is designed to be used in dry rooms. It must not be used in areas where splashed water is present. (GB)
The oil level in the compressor pump must be checked before commissioning. (GB)
The compressor may only be used outdoor briefly when the ambient conditions are dry. (GB)
The compressor must always be kept dry and must not be left outdoors after work is complete. (GB)
Compressor oil (Fig. L) preparation:
- Remove the oil plug (y) from the oil filling opening. (GB)
- Fill the compressor oil supplied into the compressor pump housing and fit the oil plug (18) into the oil filling opening. (GB)
- Check the oil level using the sight glass (16). The oil level must be within the red circle. (GB)
How do I start up and adjust the pressure on the SCHEPPACH HC550TC 400V compressor after assembly?
To start up the SCHEPPACH HC550TC 400V compressor, turn the on/off switch (5) on the pressure switch (7) to the “Auto” position. If the pressure in the pressure vessel (12) is too low, the compressor will start up automatically. To switch the compressor off, turn the on/off switch (5) to the “Off” position. (GB)
To adjust the pressure: The pressure at the manometer (9) is adjusted with the pressure regulator (8). The adjusted pressure can be drawn from the quick coupling (10, 19). The vessel pressure can be read off at the pressure gauge (11). (GB)
The pressure switch (7) is set at the factory. Switch-on pressure approx. 8 bar, switch-off pressure approx. 10 bar. (GB)
To relieve overpressure after work is complete, release overpressure in the compressor by switching off the compressor and using up the compressed air still in the pressure vessel, e.g. with a compressed air tool running at idle or with an air blow gun. (GB)
What are the technical specifications for the SCHEPPACH HC550TC 400V compressor?
The technical data for the SCHEPPACH HC550TC 400V compressor are as follows:
| Specification | Value |
|---|---|
| Mains power connection | 400 V~ / 50 Hz |
| Motor output | 3000 W / 4 PS |
| Operating mode | S1 |
| Motor speed | 29000 rpm |
| Pressure vessel volume | 100 l |
| Operating pressure | 10 bar |
| Theo. Ansaugleistung | 550 l/min |
| Theo. Abgabeleistung | 350 l/min |
| Schutzart | IP32 |
| Gerätegewicht | 79.6 kg |
| Oil (15W 40) | 1.2 l |
| Max. Aufstellhöhe (ü. NN) | 1000 m |
| Riemenart | A-1400 |
Technical changes are reserved! (GB)
What should I do if the SCHEPPACH HC550TC 400V compressor does not start?
If the SCHEPPACH HC550TC 400V compressor does not start, check the following:
- Mains voltage not present: Check cable, mains plug, fuse and socket. (GB)
- Mains voltage too low: Avoid extension cables that are too long. Use extension cables with sufficient conductor cross section. (GB)
- Outdoor temperature too low: Do not operate at outside temperatures below +5°C. (GB)
- Motor is overheated: Let the motor cool down, if necessary, eliminate the cause of overheating. (GB)
What should I do if the SCHEPPACH HC550TC 400V compressor runs but produces no pressure?
If the SCHEPPACH HC550TC 400V compressor runs but produces no pressure, check the following:
- The safety valve leaks: Replace the safety valve. (GB)
- The seals are damaged: Check the seal, have defective seals replaced at a specialist workshop. (GB)
- Drain screw for condensate is leaking: Tighten the screw by hand. Check the seal on the screw, replace if necessary. (GB)
What should I do if the SCHEPPACH HC550TC 400V compressor runs, pressure is indicated on the manometer, but the tools are not running?
If the SCHEPPACH HC550TC 400V compressor runs, pressure is indicated on the manometer, but the tools are not running, check the following:
- Hose connection is leaking: Check compressed air hose and tool, replace if necessary. (GB)
- Quick-coupler is leaking: Check quick coupling, replace if necessary. (GB)
- Pressure set too low at pressure regulator: Turn up the pressure regulator further. (GB)
How should the SCHEPPACH HC550TC 400V compressor be cleaned?
To clean the SCHEPPACH HC550TC 400V compressor:
- Pull out the mains plug before carrying out any cleaning or maintenance work! Danger of injury due to electric shocks! (GB)
- Wait until the device has cooled down completely! Danger of burning! (GB)
- Depressurise the device before carrying out any cleaning or maintenance work! Danger of injury! (GB)
- We recommend that you clean the device directly after every use. (GB)
- Keep the device as free of dust and dirt as possible. Rub the device clean with a clean cloth or blow it off with compressed air at low pressure. (GB)
- We recommend that you clean the device directly after every use. (GB)
- Clean the device at regular intervals using a damp cloth and a little soft soap. Do not use any cleaning products or solvents; they could attack the plastic parts of the device. Make sure that no water can penetrate the device interior. (GB)
- The hose and injection tools must be disconnected from the compressor before cleaning. The compressor must not be cleaned with water, solvents or similar. (GB)
How is the V-belt on the SCHEPPACH HC550TC 400V compressor changed?
To change the V-belt on the SCHEPPACH HC550TC 400V compressor:
- Be sure to disconnect the device from the mains. Once the compressor has been successfully disconnected from the mains, remove the protective grate by turning the plastic clips (33) 90° using pliers. (GB)
- Then remove the screw (31) including washers (32), which connects the protective grate (2) with the motor (4) using a 4 mm Allen key. (GB)
- Now undo the four screws (33) on the motor (4) with two size 14 spanners, so that you can subsequently slide the motor. (GB)
- It is now possible to change the V-belt (3). (GB)
- After successfully changing the V-belt, perform the same steps in reverse order to bring the device back into operational condition. Make sure the motor is bolted at a right angle to the running direction, in order to guarantee fault-free running of the V-belt. (GB)
How should the pressure vessel of the SCHEPPACH HC550TC 400V compressor be maintained?
To ensure a long service life for the pressure vessel (12) on the SCHEPPACH HC550TC 400V compressor:
- Drain off the condensate after each use by opening the drain screw (21). Release the vessel pressure beforehand (see 10.5). (GB)
- The drain screw is opened by turning it counter-clockwise (when looking at the screw on the bottom of the compressor) so that the condensate can be completely drained out of the pressure vessel. Then close the drain screw again (turn clockwise). (GB)
- Check the pressure vessel for rust and damage each time before use. The compressor shall not be operated if the pressure vessel is damaged or rusty. If you discover damage, please contact the customer service workshop. (GB)
- The condensate from the pressure vessel contains oil residue. Dispose of the condensate in an environmentally friendly manner at a suitable collection point. (GB)
How is the safety valve (20) on the SCHEPPACH HC550TC 400V compressor actuated?
To actuate the safety valve (20) on the SCHEPPACH HC550TC 400V compressor:
- Actuate the safety valve every 30 operating hours but at least 3 times a year to ensure that it works when required. (GB)
- Turn the perforated drain nut (20.1) anti-clockwise to open it, then pull the valve stem outwards by hand via the perforated drain nut (20.1) to open the safety valve outlet. Now, the valve audibly releases air. Then turn the drain nut clockwise again to tighten. (GB)
How often should the oil level be checked on the SCHEPPACH HC550TC 400V compressor?
To check the oil level regularly on the SCHEPPACH HC550TC 400V compressor:
- Place the compressor on a level and straight surface. (GB)
- The oil level must be at the centre of the oil sight glass (16) (red dot). (GB)
What is the procedure for changing the oil on the SCHEPPACH HC550TC 400V compressor?
The procedure for oil change on the SCHEPPACH HC550TC 400V compressor:
- The original oil filling must be changed after 10 operating hours; afterwards the oil must be drained and replaced with new oil after every 50 operating hours. (GB)
- Switch the motor off and unplug the mains plug from the power outlet. Remove the oil drain screw (15). Additionally open the oil plug (18). (GB)
- To prevent the oil from running out in an uncontrolled manner, hold a small metal chute under the opening and collect the oil in a vessel. If the oil does not drain out completely, we recommend tilting the compressor slightly. (GB)
- Once the oil has fully drained out, replace the oil drain screw (15). (GB)
- Dispose of the old oil at a drop-off point for old oil. (GB)
- To fill in the correct quantity of oil, make sure that the compressor stands on an even surface. (GB)
- Remove the oil plug (18) and add new oil through the oil filling opening until the oil level in the oil sight glass (16) has reached the correct quantity (red dot). (GB)
- Do not exceed the maximum filling quantity. Overfilling the equipment may result in damage. (GB)
- Reinsert the oil plug (18) in the oil filling opening. (GB)
How should the air filter be cleaned on the SCHEPPACH HC550TC 400V compressor?
To clean the air filter on the SCHEPPACH HC550TC 400V compressor:
- The air filter prevents dust and dirt being sucked in. It is necessary to clean this filter at least every 300 operating hours. A blocked air filter significantly reduces the compressor power. (GB)
- Remove the air filter by opening the wing nut (27) on the air filter housing (1). Remove the wing nut (27). (GB)
- Then draw out the air filter housing (1). Draw the air filter housing (1) apart. You can now remove the air filter. (GB)
- Carefully knock out the air filter and the parts of the filter housing. (GB)
- These components must then be blown out with compressed air (approx. 3 bar) and reassembled in reverse order. (GB)
What connections and repairs are permissible for the electrical equipment of the SCHEPPACH HC550TC 400V compressor?
Connections and repair work on the electrical equipment of the SCHEPPACH HC550TC 400V compressor may only be carried out by electricians. (GB)
When making enquiries, please provide the following information:
- Type of current for the motor. (GB)
- Machine data – type plate. (GB)
- Motor data – type plate. (GB)
What are the wearing parts of the SCHEPPACH HC550TC 400V compressor that may require replacement?
The wearing parts* for the SCHEPPACH HC550TC 400V compressor are: Air filter, V-belt, cylinder, piston, piston rings, plastic clips. (* may not be included in the scope of delivery!) (GB)
How should the SCHEPPACH HC550TC 400V compressor be stored?
Storage instructions for the SCHEPPACH HC550TC 400V compressor:
- Disconnect the mains plug, vent the device and all connected compressed air tools. Store the compressor in such a way that it cannot be used by unauthorised persons. (GB)
- Store the device and its accessories in a dark, dry and frost-free place that is inaccessible to children. The optimum storage temperature is between 5 and 30 ˚C. (GB)
- Keep the tool in its original packaging. Cover the tool to protect it from dust or moisture. (GB)
- Store the operating manual with the tool. (GB)
How should the SCHEPPACH HC550TC 400V compressor be transported?
To change the position of the SCHEPPACH HC550TC 400V compressor, lift the transport handle and pull the device to the new location. When transporting the device in a vehicle it must be secured to the loading bed with straps. (GB)
What are the required maintenance tools for the SCHEPPACH HC550TC 400V compressor?
You require the following tools for maintenance on the SCHEPPACH HC550TC 400V compressor:
- Open-ended spanner 17 mm (not included in the scope of delivery). (GB)
- Open-ended spanner 24 mm (not included in the scope of delivery). (GB)
What is the maximum installation altitude for the SCHEPPACH HC550TC 400V compressor?
The maximum installation altitude (above sea level) for the SCHEPPACH HC550TC 400V compressor is 1000 m. (GB)
What is the required oil type and capacity for the SCHEPPACH HC550TC 400V compressor?
The required oil type and capacity for the SCHEPPACH HC550TC 400V compressor is 15W 40, and the capacity is 1.2 l. (GB)
What is the maximum permissible working pressure for the SCHEPPACH HC550TC 400V compressor?
The operating pressure for the SCHEPPACH HC550TC 400V compressor is 10 bar. (GB)
What are the noise data specifications for the SCHEPPACH HC550TC 400V compressor?
The noise data specifications for the SCHEPPACH HC550TC 400V compressor are:
| Specification | Value |
|---|---|
| Sound power level LWA | 97 dB |
| Sound pressure level LpA | 81.7 dB |
| Uncertainty KWA/pA | 2.2 / 3 dB |
Warning: Noise can have serious effects on your health. If the machine noise exceeds 85 dB, please wear suitable hearing protection. (GB)
What is the theoretical suction capability of the SCHEPPACH HC550TC 400V compressor?
The theoretical suction capability of the SCHEPPACH HC550TC 400V compressor is 550 l/min. (GB)
What is the theoretical output performance of the SCHEPPACH HC550TC 400V compressor?
The theoretical output performance of the SCHEPPACH HC550TC 400V compressor is 350 l/min. (GB)
What is the protection category of the SCHEPPACH HC550TC 400V compressor?
The protection category of the SCHEPPACH HC550TC 400V compressor is IP32. (GB)
What is the belt type for the SCHEPPACH HC550TC 400V compressor?
The belt type for the SCHEPPACH HC550TC 400V compressor is A-1400. (GB)
How should the SCHEPPACH HC550TC 400V compressor be connected to the electrical mains?
The electrical motor installed on the SCHEPPACH HC550TC 400V compressor is connected and ready for operation. The connection complies with the applicable VDE and DIN provisions. The customer’s mains connection as well as the extension cable used must also comply with these regulations. (GB)
When working with spray attachments and during temporary use outdoors, the device must be connected to a residual current circuit breaker with a trigger current of 30 mA or less. (GB)
For a 3-phase motor 400 V~ / 50 Hz, the mains power connection and extension leads must be 5-core = 3 P + N + SL. – (3/N/PE). Extension cables must have a minimum cross section of 1.5mm². The mains power connection will be protected with a max. 16 A fuse. (GB)
If the mains connection cable for the product is damaged then it must be replaced by the manufacturer or their customer services personnel or by a similarly qualified person, in order to avoid hazards. (GB)
Connections and repair work on the electrical equipment may only be carried out by electricians. (GB)
What should be done if the electrical connection cable on the SCHEPPACH HC550TC 400V compressor is damaged?
If the electrical connection cable on the SCHEPPACH HC550TC 400V compressor is damaged:
- It must be replaced by the manufacturer or an electrician to avoid danger. There is a risk of electric shock. (GB)
- Check the electrical connection cables regularly for damage. Ensure that the connection cables are disconnected from electrical power when checking for damage. (GB)
- Electrical connection cables must comply with the applicable VDE and DIN provisions. Only use connection cables with the designation H05VV-F. The printing of the type designation on the connection cable is mandatory. (GB)
What is the recommended procedure before starting the SCHEPPACH HC550TC 400V compressor?
Before commissioning the SCHEPPACH HC550TC 400V compressor:
- Before connecting the machine, make certain that the data on the type plate matches with the mains power data. (GB)
- Fill the compressor pump housing with oil as described in point 9.5. (GB)
- Check the device for transport damage. Report any damage immediately to the transport company which was used to deliver the compressor. (GB)
- Install the compressor near the point of consumption. (GB)
- Long air lines and supply cables (extension cable) should be avoided. (GB)
- Ensure that the intake air is dry and dust-free. (GB)
- Do not deploy the compressor in damp or wet areas. (GB)
- Operate the compressor only in suitable areas (well ventilated, ambient temperature +5°C to 40°C). There must be no dust, acids, vapours, explosive gases or inflammable gases in the room. (GB)
- The compressor is designed to be used in dry rooms. It must not be used in areas where splashed water is present. (GB)
- The oil level in the compressor pump must be checked before commissioning. (GB)
- The compressor may only be used outdoor briefly when the ambient conditions are dry. (GB)
- The compressor must always be kept dry and must not be left outdoors after work is complete. (GB)
What maintenance is required for the pressure vessel of the SCHEPPACH HC550TC 400V compressor?
Maintenance for the pressure vessel (12) of the SCHEPPACH HC550TC 400V compressor:
- To ensure a long service life for the pressure vessel (12), drain off the condensate after each use by opening the drain screw (21). Release the vessel pressure beforehand (see 10.5). (GB)
- Check the pressure vessel for rust and damage each time before use. The compressor shall not be operated if the pressure vessel is damaged or rusty. If you discover damage, please contact the customer service workshop. (GB)
How should the safety valve (20) of the SCHEPPACH HC550TC 400V compressor be maintained?
To maintain the safety valve (20) of the SCHEPPACH HC550TC 400V compressor:
- The safety valve (20) is set to the maximum permissible pressure of the pressure vessel. It is not permitted to adjust the safety valve or to remove the connection lock (20.2) between the drain nut (20.1) and its cap (20.3). (GB)
- Actuate the safety valve every 30 operating hours but at least 3 times a year to ensure that it works when required. (GB)
How do I change the V-belt (3) on the SCHEPPACH HC550TC 400V compressor?
To change the V-belt (3) on the SCHEPPACH HC550TC 400V compressor (Fig. H to K):
- Be sure to disconnect the device from the mains. Once the compressor has been successfully disconnected from the mains, remove the protective grate by turning the plastic clips (33) 90° using pliers. (GB)
- Then remove the screw (31) including washers (32), which connects the protective grate (2) with the motor (4) using a 4 mm Allen key. (GB)
- Now undo the four screws (33) on the motor (4) with two size 14 spanners, so that you can subsequently slide the motor. (GB)
- It is now possible to change the V-belt (3). (GB)
- After successfully changing the V-belt, perform the same steps in reverse order to bring the device back into operational condition. Make sure the motor is bolted at a right angle to the running direction, in order to guarantee fault-free running of the V-belt. (GB)
What is the procedure for cleaning the air filter of the SCHEPPACH HC550TC 400V compressor?
To clean the air filter of the SCHEPPACH HC550TC 400V compressor:
- The air filter prevents dust and dirt being sucked in. It is necessary to clean this filter at least every 300 operating hours. (GB)
- Remove the air filter by opening the wing nut (27) on the air filter housing (1). Remove the wing nut (27). (GB)
- Then draw out the air filter housing (1). Draw the air filter housing (1) apart. You can now remove the air filter. (GB)
- Carefully knock out the air filter and the parts of the filter housing. (GB)
- These components must then be blown out with compressed air (approx. 3 bar) and reassembled in reverse order. (GB)
What should I do if the motor of the SCHEPPACH HC550TC 400V compressor overheats?
If the motor of the SCHEPPACH HC550TC 400V compressor overheats, let the motor cool down and, if necessary, eliminate the cause of overheating. (GB)
What should be done regarding the disposal and recycling of the SCHEPPACH HC550TC 400V compressor and its packaging?
Disposal and recycling for the SCHEPPACH HC550TC 400V compressor:
Notes for packaging: The packaging materials are recyclable. Please dispose of packaging in an environmentally friendly manner. (GB)
Notes on the Electrical and Electronic Equipment act (ElektroG): Waste electrical and electronic equipment does not belong in household waste, but must be collected and disposed of separately! (GB)
- Used batteries or rechargeable batteries that are not installed permanently in the old device must be removed non-destructively before disposal! Their disposal is regulated by the battery act. (GB)
- Owners or users of electrical and electronic devices are legally obliged to return them after use. (GB)
- The end user is responsible for deleting their personal data from the old device being disposed of! (GB)
- The symbol of the crossed-out dustbin means that waste electrical and electronic equipment must not be disposed of with household waste. (GB)
- Waste electrical and electronic equipment can be handed in free of charge at the following places: Public disposal or collection points (e.g. municipal works yards). Points of sale of electrical appliances (stationary and online), provided that dealers are obliged to take them back or offer to do so voluntarily. Up to three waste electrical devices per type of device, with an edge length of no more than 25 centimetres, can be returned free of charge to the manufacturer without prior purchase of a new device from the manufacturer or taken to another authorised collection point in your vicinity. Further supplementary take-back conditions of the manufacturers and distributors can be obtained from the respective customer service. (GB)
- If the manufacturer delivers a new electrical device to a private household, the manufacturer can arrange for the free collection of the old electrical device upon request from the end user. Please contact the manufacturer’s customer service for this. (GB)
- These statements only apply to devices installed and sold in the countries of the European Union and which are subject to the European Directive 2012/19/EU. In countries outside the European Union, different regulations may apply to the disposal of waste electrical and electronic equipment. (GB)
You can find out how to dispose of the disused device from your local authority or city administration. (GB)
Fuels and oils: Before disposing of the device, the fuel tank and the motor oil tank must be emptied! Fuel and engine oil do not belong in household waste or drains, but must be collected or disposed of separately! Empty oil and fuel tanks must be disposed of in an environmentally friendly manner. (GB)
CLICK HERE TO DOWNLOAD SCHEPPACH HC550TC 400V (01) PDF DOCUMENT