What are the unit specifications for the SANYO 30K12W?

The unit specifications for the SANYO 30K12W are as follows:

Item Specification
Capacity 28,000 / 27,000 BTU/hr
Air circulation (High) 750 / 710 cu.ft./min.
Moisture removal (High) 8.1 / 7.8 Pints/hr.
Frequency 60 Hz
Phase Single
Voltage rating 230 / 208 V
Available voltage range 187 ~ 253 V
Running amperes 13.0 / 13.9 A
Power input 2,900 / 2,830 W
Power factor 97 / 98 %
S.E.E.R. 10.0 / 10.0 BTU/Whr.

What are the physical dimensions and weight of the SANYO 30K12W indoor and outdoor units?

Dimension/Weight Indoor unit (K3012W) Outdoor unit (C3012)
Height 14-9/16 in. (370 mm) 38 in. (965 mm)
Width 59-1/16 in. (1,500 mm) 26-3/8 in. (670 mm)
Depth 9-7/16 in. (240 mm) 26-3/8 in. (670 mm)
Net weight 64 lbs. (29 kg) 200 lbs. (91 kg)
Shipping volume 9.2 cu.ft. (0.260 cu.m) 25 cu.ft. (0.708 cu.m)
Shipping weight (Approx.) 79 lbs. (36 kg) 227 lbs. (103 kg)

How do I operate the SANYO 30K12W in Manual Cooling mode?

To operate the SANYO 30K12W in Manual Cooling mode:

Step 1: Set the COOL/FAN SELECTOR knob to COOL.

Step 2: Set the OPERATION SELECTOR knob to MANUAL.

Step 3: Set the FAN SPEED as desired.

Step 4: Press the OPERATION ON/OFF button. To stop the air conditioner, press the OPERATION ON/OFF button again.

Note: This appliance has a built-in 3-minute time delay circuit to ensure reliable operation. If the operation button is pressed, the compressor will start running after three minutes. In the event of power failure, the unit will stop. When the power is applied, the unit will re-start automatically after 3 minutes.


What is the Energy Saver Mode on the SANYO 30K12W and how do I use it?

By selecting this mode and pressing the OPERATION ON/OFF button, the air conditioner will perform cooling operation until the temperature in the room reaches the set value, then the thermostat will cause the unit to pause. After about 30 minutes, the air conditioner will automatically raise the set temperature 2°F to save energy without sacrificing comfort. This function is convenient when the room is vacant or soft cooling is needed.

To use Energy Saver Mode:

Step 1: Set the OPERATION SELECTOR knob to ENERGY SAVER before turning the system on.

Step 2: Press the OPERATION button. The ENERGY SAVER and COOL lamps will light.

To cancel the Energy Saver mode, move the selector to MANUAL.


How does the Night Setback Mode work on the SANYO 30K12W?

By selecting this mode and pressing the OPERATION ON/OFF button, the air conditioner will perform cooling operation until the temperature in the room reaches the set value, then the thermostat will cause the unit to pause. After about 30 minutes, the air conditioner will automatically raise the set temperature 2°F. When the room temperature reaches the newly set value, the thermostat will cause the unit to pause. After about 30 minutes, the temperature is again raised by 2°F. This function is convenient when leaving the air conditioner on all night or soft cooling is needed.

To use Night Setback Mode:

Step 1: Set the “H” OPERATION SELECTOR knob to NIGHT SETBACK before turning the system on.

Step 2: Press the “A” OPERATION ON/OFF button. The NIGHT SETBACK and COOL lamp will light.


How do I adjust the fan speed on the SANYO 30K12W?

Automatic Adjustment:

Simply set the FAN SPEED selector to the “AUTO” position. A microcomputer in the air conditioner automatically controls the fan speed when the AUTO mode is selected. When the air conditioner starts operating, the difference between the room temperature and the set temperature is detected by the microcomputer which then automatically switches the fan speed to the most suitable level.

When difference between room temperature and set temperature is FAN SPEED
4°F High
Between 4°F and 2°F Medium
Below 2°F Low

Manual Adjustment:

If you want to adjust the fan speed manually during cooling, just set the FAN SPEED control as desired (HIGH, MED, or LOW).


How do I use the timer function on the SANYO 30K12W?

Timer OFF Mode (System stops after set hours):

Step 1: Set the TIMER SET knob to the desired number of hours. (e.g., set to 6 for six hours).

Step 2: Set the OPERATION SELECTOR knob to TIMER OFF. The TIMER lamp will light.

Step 3: Press the OPERATION ON/OFF button. The TIMER lamp will light.

Timer ON Mode (System starts after set hours):

Step 1: Set the TIMER SET knob to the desired number of hours.

Step 2: Set the OPERATION SELECTOR knob to TIMER ON.

Step 3: Press the OPERATION ON/OFF button. The TIMER lamp will light.

Note: If power failure occurs, the time counted up to that point will become void. After the power is applied, the timer newly starts counting at the set time.


How do I adjust the air flow direction on the SANYO 30K12W?

Horizontal Adjustment:

The horizontal air flow can be adjusted by moving the vertical vane to the left or right.

Vertical Adjustment:

Hold both ends of the flap and move the flap up and down to adjust the vertical air flow.

Note: Be sure to set the flap within zone “A” for COOLING. If the flap is set within zone “B”, condensation may form near the air outlet grille and drip onto the floor.


How should I select an installation site for the indoor unit of the SANYO 30K12W?

AVOID:

• Areas where leakage of flammable gas may be expected.

• Places where large amounts of oil mist exist.

• Direct sunlight.

• Nearby heat sources that may affect performance of the unit.

• Locations where remote control will be splashed with water or affected by dampness or humidity.

• Installing remote control unit behind curtains or furniture that obstruct air circulation.

DO:

• Select an appropriate position from which every corner of the room can be uniformly cooled. (High on the wall is best.)

• Select a location that will hold the weight of the unit.

• Select a location where piping and drain pipe have shortest run to the outside.

• Allow room for operation and maintenance as well as unrestricted air flow around the unit.

• Install unit within the maximum height up or down of outdoor unit and within a total piping length stipulated (Max allowable piping length: 50 ft. / Limit of piping length: 100 ft.).

• Allow room for mounting control unit about 1 m (4 ft.) off the floor, in an area that is not in direct sunlight or in the flow of cool air from the unit.


What are the piping connection torque specifications for the SANYO 30K12W?

When connecting pipes between the indoor and outdoor units:

• Flare nut on large dia. pipe (5/8″ pipe) should be torqued to 520 ~ 560 lbs. in.

• Flare nut on large dia. pipe (3/4″ pipe) should be torqued to 600 ~ 680 lbs. in.

• Flare nut on the narrow pipe (3/8″ pipe) should be torqued to 300 – 340 lbs-in.

After performing a leak test on the connecting part, insulate it with an insulation and finish with a vinyl masking tape over it.


How do I perform air purging on the SANYO 30K12W?

Air Purging Procedure (Conventional evacuation system):

1. Check gas leakage of all joints with liquid soap.

2. If no gas leakage is confirmed, connect both vacuum pump and vacuum gauge to service valve through 1/4″ port with a flare nut.

3. Run the vacuum pump until the pressure reaches to 1.5 mm Hg abs. or less value than that.

4. Close the low pressure side knob on the gauge manifold valve and stop evacuation.

5. Remove the cap from the wide pipe service valve and turn the spindle gradually until it is back seated.

6. Disconnect vacuum pump and gauge manifold valve from the service valve. Then replace bonnet and flare nut to 1/4″ port of service valve.

7. The spindle of narrow pipe service valve shall be fully back seated. Then, tighten the valve seal cap with the copper gasket.

8. The all air purge procedure has been completed and the unit is ready for trial operation.


How do I clean the air filter on the SANYO 30K12W?

The air filter behind the air intake grille should be checked and cleaned at least once every two weeks.

Step 1: Place the flap on the air outlet grille in the bottom-most position.

Step 2: Grasp the air filter by the tab at the bottom, and pull downward.

Step 3: Use a vacuum cleaner to remove light dust. If there is sticky dust on the filter, wash the filter in lukewarm, soapy water, rinse it in clean water, and dry it.

Step 4: When replacing the filter, check that the FRONT mark is facing you.


How should I clean the casing and grille of the SANYO 30K12W indoor unit?

Clean the casing and grille of the indoor unit with a vacuum cleaner brush, or wipe them with a clean soft cloth. If these parts are stained, use a clean cloth moistened with a mild liquid detergent. When cleaning the grille, be careful so as not to force the vanes out of place.

CAUTION:

1. Do not pour water on the unit to clean it. This will damage the internal components and cause an electric shock hazard.

2. Never use solvents, or harsh chemicals. Do not wipe the plastic casing using very hot water.


What should I check if the SANYO 30K12W air conditioner does not operate and the circuit breaker trips?

If the circuit breaker trips or the fuse blows:

1. Check the interunit power line (between indoor and outdoor units). Is the wiring correct? If No, execute rewiring. If Yes, check for a possibility of a ground fault.

2. Check insulation resistance of power supply cords.

3. Check insulation resistance of the outdoor unit. Is the insulation resistance low?

4. If the resistance value is 1 MΩ or less, remove the interunit power cables and check insulation resistance between terminal (2) and ground and between terminal (1) and ground in the electrical component box of the outdoor unit.

5. If insulation is defective in the outdoor unit, check insulation of the compressor motor, outdoor fan motor, and crankcase heater.

6. If insulation is defective in the indoor unit, check insulation of the indoor fan motor and transformer.


What steps should be taken if neither the indoor nor outdoor unit of the SANYO 30K12W runs?

1. Check the power supply. Is power being supplied to the wall receptacle? If No, wait for recovery or contact the power company.

2. If Yes, check the operation lamp. Is the lamp lit? If No, check the fuse on the P.C.B. Ass’y for continuity.

3. If the fuse is blown, replace it. If the fuse blows again, check the power transformer and indoor fan motor. If these are defective, replace them.

4. If the P.C.B. Ass’y is defective, replace it.


How do I disassemble the casing on the SANYO 30K12W indoor unit?

1. Remove the side cover (A) by unfastening two screws.

2. Remove the front panel (B) by unfastening three screws and then (B), other panels can be done by the same method.


How do I remove the evaporator on the SANYO 30K12W indoor unit?

1. Remove the electrical component box.

2. Loosen the fixing screws of the flap Ass’y and remove the flap Ass’y.

3. Remove the refrigerant piping holder (A).

4. Remove the evaporator mounting plate (D).

5. The evaporator and drain pan can be pulled out after removing the screws shown in the diagram.


What is the pump down procedure for the SANYO 30K12W?

Pump down means collecting all refrigerant in the system back into the outdoor unit without losing refrigerant gas. Pump down is used when the unit is moved or for servicing the refrigerant circuit.

1. Close valve on wide pipe halfway (2 turns).

2. Close valve on narrow pipe all the way (4 turns).

3. Turn unit on (cooling) for approximately 3 minutes then shut off.

4. Close valve on wide pipe all the way (2 additional turns).

5. Disconnect pipes slowly allowing pressure to equalize inside and out.

6. When piping is disconnected provide dust covers for both valves and pipes until unit is reconnected.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

CLICK HERE TO DOWNLOAD SANYO 30K12W (01) PDF DOCUMENT


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.