What are the primary safety precautions I should follow when using the RHINO SG3H-SD back bar cooler?

When using your RHINO SG3H-SD, please observe the following safety precautions and instructions at all times:

• This appliance is for indoor use only.

• Do not use this appliance other than for its intended use as a beverage display cooler.

• Always disconnect the mains power supply before removing any covers, performing maintenance work, cleaning or making any repairs.

• Do not cover the front grille or rear air vents and please observe the installation and setting up instructions.

• Do not probe any openings in the cabinet and be careful not to touch any moving parts such as the fans, or hot surfaces such as the compressor, or rear pipework; or cold surfaces such as the interior surfaces or the evaporator plate.

• Do not overload the power supply. Always ensure that the power supply is sufficient for the electrical requirements specified on the rating label. Never use adaptors or multi-block extension leads to connect the appliance to the mains power.

• Do not store explosive substances such as aerosol cans with a flammable propellant inside this appliance.

• Do not use any electrical appliances inside the refrigerated compartment of this appliance.

• Do not damage the refrigeration circuit. If you do so, then open a window or door immediately so as to ventilate the area. The refrigerant is flammable.

• During all operations, please be careful not to jolt, jar, bump or thump the cabinet. Handle it gently and with care.

• Do not exceed the maximum shelf loading weight of 25 kgs per shelf so as to avoid injury or damage.

• Never move or tilt the appliance whilst the power switch is in the “ON” position.

• The appliance must always be earthed.


Who should perform electrical work or refrigeration repairs on the RHINO SG3H-SD?

Any refrigeration repair or any electrical work on the RHINO SG3H-SD must only be carried out by suitably qualified, competent, and skilled persons. A skilled person is somebody who possesses the appropriate technical training, experience and valid certifications necessary to be aware of the hazards to which he or she may be exposed and of the measures necessary to minimise the dangers to themselves and other persons.


Can children use the RHINO SG3H-SD?

The RHINO SG3H-SD can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.


What should I do if the power supply cord for my RHINO SG3H-SD is damaged?

If the mains power supply cord for your RHINO SG3H-SD is damaged, it must be replaced by the appliance manufacturer, its service agent or suitably qualified, competent and skilled persons in order to avoid a hazard.


How should I unpack and position my RHINO SG3H-SD?

• During all operations, please be careful not to jolt, jar, bump or thump the cabinet. Handle it gently and with care as the refrigeration pipework is delicate.

• Remove all packaging and ensure that it is recycled in accordance with all local laws and regulations.

• Take care not to pinch or damage the power cord in any way. Please examine the power cord for any splits, cuts or damage.

• Do not place it next to a source of heat or humidity, in direct sunlight, or near to a source of static electricity.

• The room must be well ventilated and free from sources of ignition.

• Please make sure the floor is level and even. If the cabinet is not level, hazards and malfunctions may occur. You may adjust the appliance using the levelling feet, being careful not to pinch your fingers.

• The appliance requires a minimum ventilation space at sides, top and rear of 20mm. The front grille must be completely unobstructed.


How do I adjust the shelves in the RHINO SG3H-SD?

The shelves in your RHINO SG3H-SD may be adjusted by moving the clips. The shelves may be adjusted by squeezing together the relevant support clips and re-locating in a new position. Please ensure the clips are fully inserted and securely located prior to loading the shelves. The clips should be mounted in such a way that the shelf is level. Failure to do so could result in the shelf falling out of position and would be dangerous.

Warning: Do not exceed the maximum shelf loading weight of 25 kgs per shelf so as to avoid injury or damage.


What are the environmental operating conditions for the RHINO SG3H-SD?

The RHINO SG3H-SD appliance is designed for a maximum of Climate Class 4. Climate Class 4 is defined as a maximum environmental condition of 30C ambient temperature and 55% relative humidity.


How do I connect the RHINO SG3H-SD to the power supply and turn it on?

1. Please observe all of the warnings and procedures stated in section 1.1.

2. Please take care not to pinch or damage the power cord in any way. If it is unsatisfactory then it must be replaced.

3. Plug in the cooler and turn on the power.

4. Switch on the appliance using the red power switch on the front control panel.


How does the RHINO SG3H-SD operate and defrost?

The RHINO SG3H-SD appliance is designed to run automatically. Defrosting is automatic and is performed by the electronic controller, requiring no user intervention. The condensate water is evaporated automatically by the system.


How do I adjust the temperature of my RHINO SG3H-SD?

The electronic controller on your RHINO SG3H-SD has been factory set to chill beverages to approximately 2 Centigrade. Should you wish to alter the set point, please adopt the following procedure:

Step 1: Press and hold the “SET” button for approximately 4 seconds until the display flashes “F1”.

Step 2: Press the set button quickly once more and the current set point temperature will be displayed.

Step 3: Press the up or down arrow buttons to adjust the setting temperature.

Step 4: Press and hold the SET button for approximately 4 seconds and your new selection will be stored. If you fail to press SET, the controller will time out and revert to the previously stored setting.


Is there a setting on the RHINO SG3H-SD controller that I should not change?

Yes. Please do not alter the value shown at F2. It must remain at 4 for the cooler to function correctly. This value represents the difference between the compressor switch on and off temperatures and should not be tampered with. To do so would invalidate the guarantee.


How should I maintain the lighting in my RHINO SG3H-SD?

The RHINO SG3H-SD uses LED lighting strips powered by a low voltage transformer. If replacement is required, please order genuine replacement parts from Rhino. Replacement is a job for an appropriately qualified, skilled and competent person.


How do I clean the interior and exterior of the RHINO SG3H-SD?

The interior walls and shelves of your RHINO SG3H-SD should be cleaned and sanitised on a regular basis to ensure hygiene regulations are met. Please do not use splashing, dripping, jetting or running water. Do not use steam. Only a damp or wet cloth should be used in conjunction with appropriate cleaning materials for the task in hand. Always follow the instructions specific to the cleaning materials being used.


How do I clean the condenser on the RHINO SG3H-SD?

The condenser must be kept clean and free of dust at all times to work efficiently. It is recommended to check that it is clean and dust free at least every three months. Please adopt the following procedure:

Step 1: Empty the appliance. Switch it off using the red power switch. Pull it out from its enclosure. Unplug from the mains power supply.

Step 2: Looking at the back of the appliance, remove the screws from the rear compartment cover.

Step 3: Locate the condenser and examine it for dust or debris.

Step 4: Clean the condenser using the nozzle of a vacuum cleaner or a soft brush. Dust that is removed must be cleared away. The condenser is a delicate component and must be treated with great care and respect. Be careful of the fan blades and be sure not to bend or deflect them in any way. NEVER use water in this area.

Step 5: Replace the cover and screws and plug back in to the mains power supply.

Note: If the condenser has been contaminated with grease or fat, then a skilled and competent refrigeration specialist will be required to do the cleaning. A fire hazard may be present.


What should I do if my RHINO SG3H-SD has a malfunction?

In the event of a malfunction, please be sure only to use a suitably qualified, competent and skilled refrigeration service engineer and insist upon genuine Rhino parts. If the appliance is under guarantee, please call the company from whom you purchased the appliance. Always have the serial number to hand. The serial number is located on the inside wall of the refrigerated compartment.


How should the RHINO SG3H-SD be disposed of at the end of its life?

The RHINO SG3H-SD contains flammable refrigerant within its sealed system and also within the insulation foam. It must be recycled by a professional, competent, authorised and regulated organisation with expertise in the handling of refrigeration appliances. For further information, please consult your local Authority.


CLICK HERE TO DOWNLOAD RHINO SG3H-SD (01) PDF DOCUMENT


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.