What are the key safety precautions when using the RHINO SG1L-SS back bar cooler?

Please observe the following safety precautions and instructions at all times for your RHINO SG1L-SS:

• This appliance is for indoor use only.

• Do not use this appliance other than for its intended use as a beverage display cooler.

• Always disconnect the mains power supply before removing any covers, performing maintenance work, cleaning or making any repairs.

• This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of knowledge if they have been given supervision or instruction. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.

• Do not cover the front grille or rear air vents. Keep all ventilation openings in the appliance enclosure clear of obstruction.

• Do not probe any openings in the cabinet. Be careful not to touch any moving parts like fans, hot surfaces like the compressor or rear pipework, or cold surfaces like the interior or evaporator plate.

• Any electrical work must only be carried out by suitably qualified, competent and skilled persons.

• Do not overload the power supply. Ensure the supply is sufficient for the electrical requirements on the rating label inside the cabinet. Do not use adaptors or multi-block extension leads.

• If the mains power supply cord is damaged, it must be replaced by the manufacturer, its service agent or suitably qualified persons to avoid a hazard.

• Do not store explosive substances such as aerosol cans with a flammable propellant inside this appliance.

• Do not use any electrical appliances inside the refrigerated compartment.

• Defrosting is automatic; do not use mechanical devices to accelerate the process.

• Do not damage the refrigeration circuit. If damaged, open a window or door immediately to ventilate the area. The refrigerant is flammable.

• The appliance must always be earthed.

• Never move or tilt the appliance while the power switch is in the “ON” position.


How should I unpack and position my RHINO SG1L-SS cooler?

When unpacking and positioning your RHINO SG1L-SS, follow these steps:

• During all operations, handle the cabinet gently and with care. Do not jolt, jar, bump or thump the unit, as the refrigeration pipework is delicate.

• The appliance is heavy; carry out a risk assessment before moving it.

• Carefully cut the banding straps. Remove all packaging and recycle it in accordance with local laws and regulations.

• Take care not to pinch or damage the power cord. Examine it for any splits, cuts or damage.

• This appliance is designed for a maximum of Climate Class 4 (30C ambient temperature and 55% relative humidity).

• Do not place it next to a source of heat or humidity (e.g., dishwasher, oven, heater outlet), in direct sunlight, or near a source of static electricity.

• The room must be well-ventilated and free from sources of ignition.

• Ensure the floor is level and even. If the cabinet is not level, you may adjust the levelling feet, being careful not to pinch your fingers.

• The appliance requires a minimum ventilation space of 20mm at the sides, top, and rear. The front grille must be completely unobstructed.


How do I adjust the shelves in the RHINO SG1L-SS?

The shelves in your RHINO SG1L-SS may be adjusted by moving the clips. Follow these steps:

1. Squeeze together the relevant support clips and remove them.

2. Re-locate the clips in a new position on the support strip.

3. Ensure the clips are fully inserted and securely located before loading the shelves.

4. The clips should be mounted in such a way that the shelf is level.

Warning: Do not exceed the maximum shelf loading weight of 25 kgs per shelf to avoid injury or damage. Failure to secure the clips properly could result in the shelf falling, which is dangerous.


How do I connect the RHINO SG1L-SS to power and turn it on?

1. Please observe all safety warnings and procedures.

2. Take care not to pinch or damage the power cord. If it is unsatisfactory, it must be replaced according to safety instructions.

3. Plug the cooler into the power outlet.

4. Switch on the appliance using the red power switch on the front control panel.


How can I adjust the temperature of my RHINO SG1L-SS?

The electronic controller is factory set to approximately 2 Centigrade. To alter the set point on your RHINO SG1L-SS, follow this procedure:

Step 1: Press and hold the “SET” button for approximately 4 seconds until the display flashes “F1”.

Step 2: Press the SET button quickly once more, and the current set point temperature will be displayed.

Step 3: Press the up or down arrow buttons to adjust the setting temperature.

Step 4: Press and hold the SET button for approximately 4 seconds, and your new selection will be stored. If you fail to press SET, the controller will time out and revert to the previously stored setting.

WARNING! Please do not alter the value shown at F2. It must remain at 4 for the cooler to function correctly. This value represents the difference between the compressor switch on and off temperatures and should not be tampered with. To do so would invalidate the guarantee.


How should I clean the interior and exterior of my RHINO SG1L-SS?

The interior walls and shelves should be cleaned and sanitised on a regular basis to ensure hygiene regulations are met.

• Please do not use splashing, dripping, jetting or running water. Do not use steam.

• Only a damp or wet cloth should be used in conjunction with appropriate cleaning materials for the task in hand.

• Always follow the instructions specific to the cleaning materials being used.


What is the procedure for cleaning the condenser on the RHINO SG1L-SS?

The condenser must be kept clean and free of dust to work efficiently. It is recommended to check and clean it at least every three months. Please adopt the following procedure:

Step 1: Empty the appliance. Switch it off using the red power switch. Pull it out from its enclosure and unplug from the mains power supply.

Step 2: Looking at the back of the appliance, remove the screws from the rear compartment cover.

Step 3: Locate the condenser and examine it for dust or debris.

Step 4: Clean the condenser using the nozzle of a vacuum cleaner or a soft brush. Dust that is removed must be cleared away. The condenser is a delicate component and must be treated with great care. Be careful of the fan blades and be sure not to bend or deflect them in any way. NEVER use water in this area.

Step 5: Replace the cover and screws and plug back in to the mains power supply.

Note: If the condenser has been contaminated with grease or fat, then a skilled and competent refrigeration specialist will be required to do the cleaning. Do not use the cabinet or plug it back in until the cleaning has been done professionally by a skilled person, as a fire hazard may be present.


What are the general operating characteristics of the RHINO SG1L-SS?

• The appliance is designed to run automatically.

• Defrosting is automatic.

• The condensate water is evaporated automatically by the system.

• Maintenance must be performed according to the procedures detailed in these instructions.


What should I do if my RHINO SG1L-SS malfunctions?

In the event of a malfunction, please be sure only to use a suitably qualified, competent and skilled refrigeration service engineer and insist upon genuine Rhino parts. Always have the serial number to hand. The serial number is located on the inside wall of the refrigerated compartment. It is often accompanied by, or located next to, a bar code.


How should the RHINO SG1L-SS be disposed of at its end-of-life?

This appliance contains flammable refrigerant within its sealed system and also within the insulation foam. It must be recycled by a professional, competent, authorised and regulated organisation with expertise in the handling of refrigeration appliances. For further information, please consult your local Authority.