Free English PIMA CLM351 (01) PDF Document. Free English PIMA CLM351 (01) PDF User Guide. Free English PIMA CLM351 (01) PDF User Manual. Free English PIMA CLM351 (01) PDF Owner Guide. Free English PIMA CLM351 (01) PDF Owner Manual. Free English PIMA CLM351 (01) PDF Reference Guide. Free English PIMA CLM351 (01) PDF Instruction Guide. Free English PIMA CLM351 (01) PDF Reference Manual. Free English PIMA CLM351 (01) PDF Instruction Manual. Free English PIMA CLM351 (01) PDF Operating Instructions.
CLICK HERE TO DOWNLOAD PIMA CLM351 (01) PDF DOCUMENT
If this is not the document you want for this product, click here to see if we have any other documents for this product.
How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.
What is the PIMA CLM351 Cellular Transmitter?
The PIMA CLM351 is an Ethernet-to-3G cellular transmitter that allows the Hunter-Pro Series and Captain 8 intruder alarm systems to communicate over a cellular network. It replaces the GSM-200 transceiver. The transmitter is supplied mounted on a bracket that is adapted to the alarm system housing.
The CLM351 is based on PIMA net4pro Ethernet card and Teltonika RUT230 router, and it supports 3G network.
The CLM351 is supplied without a SIM card.
What are the general technical specifications for the PIMA CLM351?
• Operating voltage: 12VDC
• Current consumption: 100mA (max)
• Weight: 360 gr
• Operational temperature: -10 to +50 °C
What are the specifications for the integrated net4pro and RUT230 components of the PIMA CLM351?
net4pro
• Fully panel integrated
• Ethernet: LAN, WAN
RUT230
• Mobile: 3G HSPA+ Up to 14.4 Mbps; UMTS; EDGE; GPRS;
• Power supply: 9-30 VDC, 4-pin DC connector
• SIM: 1 x external SIM holder
• Status LEDs: 2 x connection type status, 5 x connection strength, 2 x LAN status, 1 x Power
• Auto Failover
• Connection monitoring: Ping Reboot, Periodic Reboot, Wget Reboot, LCP and ICMP for link inspection
Can you identify the parts of the PIMA CLM351?
| # | Part Name | # | Part Name |
|---|---|---|---|
| 1 | CLM351 Transmitter | 8 | Status LED (net4pro) |
| 2 | RUT230 router | 9 | CAT5 Bridging Cable |
| 3 | 3G Antenna | 10 | Power Socket |
| 4 | DC and Serial Data Terminal Block | 11 | SIM Card Holder |
| 5 | Molex Cable | 12 | Mobile signal strength indication LEDs |
| 6 | SERIAL Socket (Hunter-Pro/Captain 8) | 13 | LAN Socket |
| 7 | DC in Plug | 14 | Reset Button |
What is included in the PIMA CLM351 product package?
• CLM351 Transmitter
• Antenna
• This guide
• SIM Needle
What are the placement guidelines for the PIMA CLM351 transmitter?
• Have a clear line of sight to the sky (where possible)
• Be clear and free of obstacles
• Be clear of metal objects
• Be located away from other transmitting devices
• Be securely affixed the antenna in location
How do I install the PIMA CLM351?
Important: Disconnect the control panel from AC and battery power before installing the CLM351.
Follow the next steps to install the transmitter.
1. Push the RUT230 SIM holder button with the supplied SIM needle, and pull out the SIM holder.
2. Insert the SIM card given by your ISP (Internet Service Provider) into the SIM holder. Mind the card orientation.
3. Slide the SIM holder back into the router.
4. Mount the bracket at the top of the control panel’s box using the supplied screws.
5. Attach the 3G antenna.
6. Connect the Molex harness of the CLM351 to the SERIAL connector on the control panel.
7. Connect the control panel to power. Check the net4pro’s Status and network LEDs illuminate, and check the router’s reception LEDs to check the signal strength.
8. Program an encryption into the net4pro using the Comax software.
9. Set the transmitter in the control panel as described in the setup instructions.
10. Test the transmitter by generating events.
How do I set the PIMA CLM351 transmitter in the control panel?
1. In an LCD keypad, enter the Technician code.
2. Press ‘3’ (Communication) and press ENTER (MS1 Options).
3. Press and hold the asterisk key (*) for two seconds (to enable the Advanced Programming menu).
4. Press BACK (Advanced Prog.) and press ENTER (Choose Provider).
5. Press BACK (Network Settings) and press ENTER (MS1 URL/IP).
6. Enter the CMS’s IP address and port number (IP:port) and press ENTER.
7. Press END X 2 (Advanced Prog.), BACK X 4 (Serial Output) and press ENTER (LNLN).
8. Press NEXT and press the pound key (#) under N (Network MS 1) to enable it (+).
9. Press Enter and then END to exit the menu.
10. If Account No.1 is not set, go to the Communication menu, press NEXT, ENTER X 2 and set it.
What are the additional setup steps if the PIMA CLM351 is replacing a GSM-200 transceiver?
If the CLM351 replaces the GSM-200 transceiver, do the steps that follow in addition to the standard setup steps:
1. Repeat steps 1-2 of the standard setup (Enter Technician code, press ‘3’ for Communication and ENTER for MS1 Options).
2. Press NEXT X 6 (GSM Transmitter) and press ENTER (GSM Settings).
3. Press ENTER (GRTYS) and press the pound key (#) under G (GSM Tx Installed) to disable it (-).
4. Press ENTER and press END to exit the menu.
What is the ordering information for the PIMA CLM351?
• CLM351: P/N 8300031
CLICK HERE TO DOWNLOAD PIMA CLM351 (01) PDF DOCUMENT