What should I check when unpacking the NB Unit?

When unpacking the NB Unit, check carefully for any external scratches or other damages. Also, shake the Unit gently and check for any abnormal sound.


Where must the NB Unit be installed?

The NB Unit must be installed in a control panel.


What are the requirements for the mounting panel?

The mounting panel must be between 1.6 and 4.8 mm thick. Tighten the Mounting Brackets evenly to a torque of between 0.5 and 0.6 N-m to maintain water and dust resistance. If the tightening torque exceeds the specified value, or the tightening is uneven, deformation of the front panel may occur. What is more, make sure the panel is not dirty or warped and that it is strong enough to hold the Units.


What precaution should be taken when preparing the panel?

Do not let metal particles enter the Units when preparing the panel.


What type of power supply should be used for the NB Unit?

Use a DC power supply. Do not connect an AC power supply to the DC power terminals. The DC power supply should have a slight voltage fluctuation and provide a stable output even if the input is momentarily interrupted for 10 ms. The Rated Power Supply Voltage is DC 24V (Allowable range DC 20.4~27.6V).


What are the critical warnings regarding product handling and operation?

Do not attempt to take the product apart and do not touch the product inside while the power is being supplied. Otherwise it may result in electric shock.

Always ensure that the personnel in charge confirm that installation, inspection, and maintenance were properly performed for the NB Unit. “Personnel in charge” refers to individuals qualified and responsible for ensuring safety during machine design, installation, operation, maintenance, and disposal.

Ensure that installation and post-installation checks are performed by personnel in charge who possess a thorough understanding of the machinery to be installed.

Do not use the input functions of the touch switch, etc. of the NB Unit, in applications that involve human life, in applications that may result in serious injury, or for emergency stop switches.

Do not attempt to disassemble, repair, or modify the NB Unit. Otherwise it may cause NB Unit to loose its safety function.

Never press at two or more points on the touch panel of the NB Unit at a time. Otherwise, it may activate a switch somewhere between the two points.


What is the caution regarding grounding for the NB-S Series?

In the case of the NB-S Series, when grounding the positive terminal of power supply of 24 V to the NB, do not ground functional grounding terminal at NB side. Some functions of a PC connected to the NB may cause a short circuit and the NB Unit may cause damage.


Why is this grounding precaution necessary for the NB-S Series?

Depending on the types of PC, SG terminals of RS-232C port or USB port and contour of connector can be connected. As the contour of tool port of the NB and the functional grounding terminal are not insulated they are connected. Therefore, connecting the PC allows GND terminal and functional grounding terminal of the NB to be connected. If the power supply of 24V to the NB is grounded positively, grounding the functional grounding terminal allows a short circuit as shown in the diagram upper right and may result in damage.


What should be considered when using the Test Function?

The Test Function is performed on PC, and it has different behaviors with actual NB running system. A problem may occur due to communication timing, cable differences and unexpected PC circumstances(such as freeze). When the Test Function is performed, please consider possible unexpected circumstances on the actual NB running system and confirm that any dangerous event will not occur beforehand.


What are the precautions for handling products containing lithium primary batteries with perchlorate?

The following precaution must be displayed on all products containing lithium primary batteries with a perchlorate content of 6 ppb or higher when exporting them to or shipping them through California, USA: Perchlorate Material-special handling may apply. See http://www.dtsc.ca.gov/hazardouswaste/perchlorate. The NB Series contains a lithium primary battery with a perchlorate content of 6 ppb or higher. When exporting a product containing the NB Series to or shipping such a product through California, USA, label all packing and shipping containers appropriately.


What cleaning agents should be avoided?

Do not use benzene, paint thinner, or other volatile solvents, and do not use chemically treated cloths.


How should the NB Units be disposed of?

Do not dispose the Units together with general waste at waste yards. When disposing them, follow the related local ordinances or rules. Dispose of the Units and batteries according to local ordinances as they apply.


Can the backlight lamp in the NB Unit be replaced?

The backlight lamp inside the NB Unit cannot be replaced.


What should be done if touch points move due to deterioration?

Deterioration over time can cause the touch points to move. Calibrate the touch panel periodically.


What happens if the front sheet is torn or peeling?

Water and oil resistance will be lost if the front sheet is torn or is peeling off. Do not use the Unit, if the front sheet is torn or is peeling off.


What maintenance is required for the rubber packing?

The rubber packing will deteriorate, shrink, or harden depending on the operating environment. Inspect the rubber packing periodically.


Are COM1 and COM2 communication cables interchangeable?

The communication cables of the COM1 and COM2 connectors are not interchangeable. Confirm the pins of the ports before carrying out communications. (NB3Q-TW00B and NB3Q-TW01B only have COM1.)


What check is needed for applications where the PT is subject to contact with oil or water?

Periodically check the installation conditions in applications where the PT is subject to contact with oil or water.


Is it permissible to perform a dielectric strength test?

Do not perform a dielectric strength test.


How should terminal screw connections be made?

Make the connection by using terminal screws crimping on a twisted-pair cable with a crimping range of 12-26AWG, and only 6.5 mm of insulation peel of the cable needs to be peeled off. Tighten the terminal screws to a torque of between 0.3 and 0.5 N-m. Make sure the screws are properly tightened.


How can malfunctions due to noise be prevented?

To prevent malfunctions caused by noise, ground the Unit correctly.


What precautions should be taken when handling the circuit board?

Do not touch the packaging part of the circuit board with your bare hands. Discharge any static electricity from your body before handling the board.


What are the specifications for using the No. 6 pin of the COM1 connector for DC+5V?

When using the No. 6 pin of the serial communication port COM1 connector for a voltage of DC+5V, make sure the supply equipment’s current capacity is below 250mA before using it. The DC+5V voltage output of the NB main unit is +5V±5%, and the maximum current is 250mA. (The serial communication port COM1 of NB3Q-TW00B and NB3Q-TW01B is unable to output the current.)


Can USB memory be used in environments with strong vibration?

Do not use the USB memory in an environment subject to strong vibration.


What are the specifications for connecting equipment to the USB HOST connector?

When connecting the equipment with the USB HOST connector, make sure the supply equipment’s current capacity is below 150mA before using it. The DC+5V voltage output of the USB HOST is +5V±5%, and the maximum current is 150mA.


When should cables be connected or disconnected?

Turn OFF the power supply before connecting or disconnecting cables.


What should be done after connecting a communication cable?

Always keep the connector screws firmly tightened after the communication cable is connected.


What is the maximum tensile load for connectors?

The maximum tensile load for connectors is 30 N. Do not apply loads greater than this.


What should be confirmed before turning power ON/OFF or pressing the reset button?

Confirm the safety of the system before turning ON or OFF the power supply, or pressing the reset button.


What can happen depending on how the power supply is turned ON/OFF?

The whole system may stop depending on how the power supply is turned ON or OFF. Turn ON/OFF the power supply according to the specified procedure.


What should be done after changing DIP switch settings?

Once the DIP switch settings are changed, reset by pressing the reset button, or restart the power supply.


How can system safety be ensured before running the system?

To ensure the system’s safety, make sure to incorporate a program that can confirm the normal functionality of the NB Unit before running the system.


When should actual system application start?

Start actual system application only after sufficiently checking screen data, macros and the operation of the program at the host side.


What is the maximum force for pressing the touch panel?

Do not press a touch panel with a force greater than 30 N.


What objects should not be used to operate or scrub the screen?

Do not use hard or pointed objects to operate or scrub the screen, otherwise the surface of the screen may be damaged.


What should be confirmed before pressing the touch panel?

Confirm the safety of the system before pressing the touch panel.


What might happen if touch switches are pressed consecutively at high speed?

Signals from the touch switches may not be input if the switches are pressed consecutively at high speed. Confirm that that the PT has detected the input of a touch switch before pressing any other touch switch.


What precaution should be taken if the backlight is not lit or the display does not appear?

Do not accidentally press the touch panel when the backlight is not lit or when the display does not appear. Make sure of the safety of the system before pressing the touch panel.


How can numeric input functions be used safely?

To use numeric input functions safely, always make maximum and minimum limit settings.


What should be done before initializing screen data?

Before initializing screen data, confirm that existing data is backed up at the NB-Designer.


What is the procedure when changing the password with the system menu?

When changing the password with the system menu, do not reset or turn OFF the power supply until writing is finished. Failure to save the password may cause the screen to fail to function.


What should be confirmed before performing operations with an equipment monitor?

When using an equipment monitor, confirm the safety of the system before carrying out the following operations:

• Changing monitor data

• Changing operation mode

• Forced set/reset

• Changing the current value or the set value


Can a USB connector be connected to any device?

Do not connect a USB connector to any device that is not applicable.


What operations should be avoided while uploading or downloading screen data or system programs to prevent corruption?

While uploading or downloading screen data or system programs, do not perform the following operations as they may corrupt the screen data or the system program:

• Turning OFF the power supply of the NB Unit

• Pulling out the USB memory

• Pressing the PT’s reset switch

Before connecting a USB connector to a device, make sure that the device is out of damage.


What precautions are needed when using a USB Hub?

Commercially available and the recommended USB Hub are different from the general specifications of the NB Unit. The Unit may not function well in an environment subject to noise, static electricity. Therefore, when using a USB Hub, employ sufficient noise and static electricity insulation measures, or install it at a site free of noise or static electricity.


In what locations should the NB Unit NOT be installed?

Do not install the Unit in any of the following locations:

• Locations subject to severe changes in temperature

• Locations subject to temperatures or humidity outside the range specified in the specifications

• Locations subject to condensation as the result of high humidity

• Locations subject to corrosive or flammable gases

• Locations subject to strong shock or vibration

• Locations outdoors subject to direct wind and rain

• Locations subject to strong ultraviolet light

• Locations subject to dust

• Locations subject to direct sunlight

• Locations subject to splashing oil or chemicals


When should countermeasures be taken for system installation locations?

Take appropriate and sufficient countermeasures when installing systems in the following locations:

• Locations subject to static electricity or other forms of noise

• Locations subject to strong electric field or magnetic field

• Locations close to power supply lines

• Locations subject to possible exposure to radioactivity


What is the specified surrounding air temperature for UL/CSA compliance?

The surrounding air temperature is 50°C.


How should the Unit power connector be wired for UL/CSA compliance?

Connect a 24V-DC isolated power supply to the power input terminals.


What are the power supply specifications for connectable power supplies (UL/CSA)?

The following table shows the specification for the power supply that can be connected:

TypeRated voltagePower supply capacity
NB3Q-TW00BDC24V5W
NB3Q-TW01BDC24V9W
NB5Q-TW0OBDC24V6W
NB5Q-TW01BDC24V10W
NB7W-TW00BDC24V7W
NB7W-TW01BDC24V11W
NB10W-TW01BDC24V14W

What is the applicable wire size for the Unit power source terminal block (UL/CSA)?

The applicable wire size for the Unit power source terminal block is as follows:

TypeWire size
Twisted-pair cableAWG12-26

Tighten the terminals screw to a torque of 5 lb-in. Make sure the screws are properly tightened.


How is the NB Series installed in a control panel (UL/CSA context)?

The NB Series are normally installed on a flat surface in an operation panel. Please refer to the following procedure:

1. Create an opening in the panel. Panel thickness: 1.6 to 4.8mm. The opening dimensions (W*H mm) and Enclosure Type vary by model:

TypeOpening dimension (W*H mm)Enclosure Type
NB3Q-TW0*B119.0*93.0Type 1, indoor use only
NB5W-TW0*B172.4*131.0Type 1, indoor use only
NB7W-TW0*B191.0*138.0Type 1, indoor use only
NB10W-TW01B258.0*200.0Type 1, indoor use only

2. Install the NB Series from the front of the panel. Direction of installing: horizontally or vertically. Angle of installing: 180°.

3. With the provided mounting brackets, secure the NB Series to the panel. Tighten them evenly to the specified torque. To maintain water-resistance performance, the tightening torque must be 0.5~0.6N.m.


What RS232C cables are recommended for the PT (UL/CSA)?

For the PT RS232C Cable, use one of the recommended cables: XW2Z-200T or XW2Z-500T.


What are the guidelines for RS422A and RS485 cables for the PT (UL/CSA)?

For RS422A and RS485 Cable for PT:

1) Do not use ferrule terminals.

2) Use the recommended cable: NB-RSEXT-2M.

3) For the setup of terminal resistance, please refer to NB Series Setup Manual (V107).


What are the requirements for communication cables (UL/CSA)?

These communication cables are Internal Wiring only. Segregate communication cables from live parts and all other wiring by minimum 6.4 mm (1/4 inch).


Is the battery user-replaceable (UL/CSA)?

Battery is not user-replaceable.


How does this product conform to EU Directives for EMC?

This product is EMC-compliant when assembled in a complete PLC system of the PLC series which type-name shows. For earthing, selection of cable and any other conditions for EMC-compliance, please refer to the manual for installation. This is a class A product. In residential areas it may cause radio interference, in which case the user may be required to take adequate measures to reduce interference.


What are the conditions for conformance to EN Standard?

• Surrounding Air Temperature: 0-50 °C (Avoid freezing or condensation)

• Surrounding Air Humidity: Max. 90%

• Indoor use only

• Altitude: Max. 2000 m

• Installation environment: Over Voltage Category II, Pollution Degree 2

• Terminal Temperature: 80 °C