What are the operating precautions for the OLYMPUS PTBK-E01?
The OLYMPUS PTBK-E01 is designed exclusively for use with the PT-E series underwater cases. Do not combine this product with any product other than those listed as compatible. Also, ensure that the PT-E series underwater case is attached securely before using this product.
Which models are compatible with the OLYMPUS PTBK-E01?
| Applicable models (As of June 2005) | |
|---|---|
| Underwater case mount for digital camera | PT-E01 |
| Arm mount for use on the bracket grip extremity | PTSA-01 |
How do I assemble the OLYMPUS PTBK-E01?
First, identify the components:
1. Bracket grip mount
2. PT-E series waterproof case mount
3. Bracket base
4. PT-E series waterproof case clamping screws (x 2)
5. Bracket grip clamping screws (x 2)
6. Bracket grip
7. Arm mount for use on the bracket grip extremity
8. Bracket grip clamping wrench
To assemble the unit:
1. Attach the bracket grip (6) to the bracket grip mount (1) on the bracket base (3) using the two bracket grip clamping screws (5).
2. Attach the PT-E series waterproof case to the PT-E series waterproof case mount (2) on the bracket base (3) using the two PT-E series waterproof case clamping screws (4).
How do I adjust the bracket grip position on the OLYMPUS PTBK-E01?
The bracket position can be adjusted according to the mounting position of the bracket base.
1. Loosen the two bracket grip clamping screws using the bracket grip clamping wrench that is provided with this product.
2. Slide the bracket grip to extend or contract the length.
3. Tighten the two bracket grip clamping screws.
How do I mount the optional PTSA-01 short arm to the OLYMPUS PTBK-E01?
The separately available PTSA-01 short arm can be mounted on the end of the bracket grip.
1. Loosen the short arm clamping screw of the separately available optional short arm.
2. Attach the short arm while taking care that it does not interfere with the rotation stopper boss. For removal, reverse the mounting procedure.
3. Tighten the short arm clamping screw.
What are the storage precautions for the OLYMPUS PTBK-E01?
• After using this product in sea water, immerse it in pure water to remove any salt.
• Be sure to detach this product from the PT-E series underwater case before storage.
• Never use alcohol, gasoline, lacquer thinner, benzine or similar organic solvents or chemical detergents to clean this product. Such chemicals can damage the product and cause it to deteriorate.
• Do not store this product when it has moisture, sand or dust on it.
What are the specifications of the OLYMPUS PTBK-E01?
Dimensions: Width 308 mm x Height 155 mm x Depth 40 mm / Thickness 6 mm (max.)
Weight: 350 grams
How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.
CLICK HERE TO DOWNLOAD OLYMPUS PTBK-E01 (01) PDF DOCUMENT