What’s included with the fountain unit?
The fountain unit comes with a 3/8" OD copper water inlet tube and a hanger bracket.
What’s not included with the fountain unit?
The following items are not included: 4x appropriate wall anchors, 1 1/4" P-Trap, and a water shut-off valve.
What tools are recommended for inspection?
The recommended tools include a pilot drill bit (for chosen wall anchors), a slotted screwdriver, a T15 Torx bit driver, a power drill (suitable for wall anchors), a bubble level, and a tape measure.
What should I inspect the carton and water cooler for?
Inspect the carton and water cooler for evidence of rough handling and concealed damage. Damage claims should be filed with the carrier.
What is the maximum water supply line pressure for this drinking water cooler?
This drinking water cooler is designed to be operated at a water supply line pressure of up to 100 psi (690 kPa).
What should I do if the water pressure exceeds 100 psi?
A pressure regulator must be installed in front of the unit’s water inlet if the water pressure (including any possible pressure spikes) could exceed 100 psi (690 kPa).
What type of circuit should this drinking water cooler be connected to?
This drinking water cooler is intended to be connected to a 20A minimum ground fault circuit interrupting (GFCI) device to meet UL requirements.
What is a warning regarding alterations or modifications to the machine?
The warranty and the Underwriters Laboratory Listing for this machine are automatically voided if this machine is altered, modified, or combined with any other machine or device. Alteration or modification of this machine may cause serious flooding and/or hazardous electrical shock or fire.
How do I install the hanger bracket?
Install the hanger bracket that came attached to the fountain unit frame with 2x of your appropriate anchors for the installation location (not provided).
What should I do before installing the unit?
FLUSH BUILDING WATER SUPPLY LINE BEFORE INSTALLING THE UNIT. Failure to do so will result in the in-line strainer at the cartridge inlet being clogged and a resulting loss in water pressure and/or damage to the cartridge.
How should I hang the fountain unit?
Hang the fountain unit on the installed wall bracket. ENSURE THE UNIT IS HUNG ON THE GALVANIZED STEEL FRAME AND NOT UNDER THE RETURN EDGE OF THE STAINLESS STEEL BASIN TOP.
How do I remove the front panel?
Remove the front panel by loosening the two front Tl5 screws at the base of the unit and by removing the two Tl5 screws at the top of the panel under the fountain nose.
How do I install the lower wall anchors?
Install 2x of your chosen wall anchors into the lower two locations called out in Figure 2. Mark the hole locations then, remove the unit to drill the pilot holes. Reinstall the unit and secure with your wall anchors.
How do I install a P-Trap?
Install a P-Trap (not provided) to the waste line stub-out and the basin drainpipe. Cut the basin drainpipe as needed.
How do I connect the water supply?
Connect the supplied copper Water Supply tube to the shut-off valve location shown in Figure 2.
How do I fill the tank after connecting the water supply?
Turn on the water supply and fill the tank by activating the dispense buttons on the unit and allow water to flow to the bubbler until you get an uninterrupted stream.
What should I check for after turning on the water supply?
Check for any leaks in the water lines and drain.
How do I adjust the bubbler stream height?
a. Locate the slotted adjustment knob in the center slot beneath the fountain nose. b. With a slotted screwdriver, rotate the cartridge adjustment knob clockwise to increase the stream height and counterclockwise to reduce it. While dispensing water, make adjustments until the stream height is a minimum of 4" per ADA requirement.
What should I do before powering on the unit?
Before powering on the unit, rotate the condenser fan blade by hand to ensure that it is free of obstructions.
How do I plug in the power supply cord?
Plug the power supply cord into the wall outlet.
What is the note about an outlet that is external to the unit frame?
For an outlet that is external to the unit frame, route the power cord through the rear most 1-1/3" knock-out at the base of the unit frame. Ensure the hole is free of any burrs. The use of a Heyco bushing #2184 is recommended.
How do I reinstall the front panel?
Reinstall the front panel previously removed in step 4.
What maintenance is required?
The only maintenance operation required is the removal of dirt and lint from the condenser where used.
How often should I inspect the unit?
Inspection should be made at 3-month intervals.
How do I access the condenser for maintenance?
To access the condenser, remove the front panel as described in step 4. To remove the side panel, remove the two screws on the bottom of the unit and loosen (but do not remove) the two rear screws on the stainless-steel basin.
How do I clean the condenser?
Disconnect the power supply cord and then clean the condenser with a small stiff non-wire or vacuum cleaner attachment brush when required.
Why is it important to clean the condenser?
Observance of this procedure will ensure adequate air circulation through the condenser so operation is efficient and economical.
How do I clean the outside of the unit?
The outside of the unit can be wiped clean with a mild soap and water mixture. Never use harsh chemicals or abrasive cleaners, including any chlorine solutions. Rinse thoroughly with clean water, then dry surfaces.
What is the overload protection for?
The compressor motor, where used, is equipped with an automatic reset protector which will disconnect the motor from the line in case of an overload.
What kind of lubrication does this unit require?
This unit is equipped with a hermetically sealed compressor and requires no additional lubrication. The fan motor, where used, on this unit seldom needs oiling, but if required, a few drops of SAE 10 oil should be used.