What tools and hardware are required?
- Electric drill/driver
- Small tubing cutter for plastic line
- 5/16“ nut driver
- 1/4” nut driver
- Means to cut 1 1/4” drain pipe
- T15 Torx screwdriver or bit
- T20 Torx screwdriver or bit
- 4 appropriate wall anchors (not supplied)
What is included in the kit?
- 10” of ¼” OD plastic tubing with 9” of tubing insulation
- Installation instructions
- Assembled NNEBFEZ Cabinet
- Side Mounting Bracket x2
- Drain Elbow x2
- Drainpipe x2
- Center Bracket
- ¼” Elbow
- ¼” Union
- #8 Torx Screws x3
- #10 Hex Screws x6
- 0.25” Terminals x2
- #8 Thread Cutting Hex Screw
- Strain Relief
- P-Clip
How do you prepare for single level NNEBFEZ installation?
- Remove fountain wrapper.
- Turn OFF water supply to the unit. Bleed any remaining pressure from the lines by activating the bubbler valve.
- Disconnect power by UNPLUGGING the unit from the wall socket.
- Loosen or remove the P-trap so that the fountain nose assembly may be freely removed.
- Remove fountain nose assembly. To do this, remove 4x #10 Torx screws from the fountain using a T20 Torx bit.
- Disconnect ONLY the nose assembly wires from the cold control and solenoid valve. Leave all other wires connected to the cold control and solenoid valve. For non-refrigerated models, unplug the unit.
- Disconnect the water line from the bubbler inside the nose. DO NOT disconnect from the fountain.
- After the nose assembly has been removed, cover the two bare terminals with the insulated female spade terminals (provided) for safety.
- Locate the solenoid valve on the Elkay unit. Disconnect both water lines from the solenoid valve. Join the two water lines together using a ¼” elbow fitting (provided). Allow the cooling tank water outlet line to extend freely upward.
How do you install the NNEBFEZ cabinet?
- Remove the kit from the packaging and separate it into the assemblies and components. Do not misplace the provided mounting screws and insulated terminals.
- Place the retrofit frame against the wall and set it onto the top flange of the cooler frame without taking the cooler off the wall. Use the two windows at the bottom of the frame to position it so that the amount of the cooler frame showing is equidistant on both sides.
- Affix the frame to the wall with at least 4 anchors into any appropriate anchor points through the staggered slotted holes. Ensure the frame stays centered on the cooler frame.
- Assemble the center bracket to the holes in each of the cooler struts.
- Assemble the two side brackets to the cooler frame using the slotted holes on the bottom with two #10 screws for each bracket. Ensure that the brackets are oriented correctly.
- Install the drip tray support bracket (keep drip tray pre-assembled) to the center bracket and frame using 4x, #8 Torx screws which are provided in the kit.
- Attach the filter guard bracket with 2x, #8 Torx screws to the frame and drip tray support bracket. This bracket helps to prevent the filter cartridge from falling into the cooler unit below during installation or replacement.
- Attach one of the drain elbows to the drip tray stem. Insert the drainpipe provided into the elbow and then attach another elbow onto the pipe. Use the remaining drainpipe and connect the drip tray drainage system to the installed P-trap. Drainpipes will need to be positioned and cut to length as needed.
- Assemble NNEBFEZ wrapper to the installed frame. Rest the alcove on the drip tray and ensure the wrapper walls rest OUTSIDE of the frame and side brackets. The drip tray will hold the weight of the wrapper but it is recommended to keep a hold on the unit during installation for safety.
- If the outer edge of the drip tray is not properly aligned, loosen the screws on the back of the drip tray support bracket and slide the bracket forward or backward as needed. Then retighten the screws.
- Once the wrapper has been installed, loosen the side bracket mounting screws until the bracket can be slid up and down. Adjust the bracket until the mounting hole screws through the slot and then drive in one of the #8 Torx screws and then tighten the two #10 mounting screws.
- Attach the ¼” union fitting to the Cooling Tank water line out.
- Attach one end of the provided ¼” water line with insulation tubing to the solenoid valve located on the alcove, and the other end to the ¼” union fitting. Cut provided water line and insulation tubing as needed.
- Guide the power cord down to the lower portion of the cooler. Ensure that the power cord does not become entangled with other components and ensure that the IEC connector is firmly installed into the power brick.
- Install the provided strain relief P-Clip to the power cord roughly 36” from the grounded plug. Attach it to the back side flange of the fountain frame with a #8 Torx screw.
- Attach the ring terminal to the ground screw on the left side of the fountain strut through the lower flared hole using the provided #8 thread cutting hex Screw. Do not remove/alter the original ground.
- Finish by plugging in the grounded plug into the duplex socket.
- Turn on water supply and check for any leaks.
- Ensure that nothing is obstructing the fan blade.
- Plug the Elkay power cord into the wall outlet.
- Test the contactless bottle filler by placing a water bottle into the alcove of the bottle filler. Check for leaks.
- Install the cabinet top panel, filter access panel and Elkay cooler wrapper.
Where can I find the programming options?
Refer to page 34 in the PDF.
How do you prepare for split level installation?
- Remove the fountain wrappers and noses from each unit as shown on pages 5-6 to prepare the units for the NNEBFEZ installation. Unplug BOTH units and shut off their water source.
- Begin split level assembly by disconnecting and removing any drainpipes except for the p-trap and disconnecting the water lines between the fountain units. Ensure water to the units has been turned off.
- Since the split level fountain cold tank is already pressurized, disconnect all water lines from the solenoid valves in both the refrigerated and dummy unit. Do not discard any water tubing. Cover any bare terminals. Refer to page 7.
- The final result should have the water line from the cold tank water outlet connect to the tee and split off to the dummy unit and up to the top of the refrigerated unit.
- Set the frame from the second NNEBFEZ kit onto the top of the dummy unit frame and mark the location for each all anchor. PRE-DRILL the holes for your chosen anchors (not included).
How do you install the NNEBFEZ for split level?
- Remove the dummy unit from the wall hanger and place it out of the way. Completely assemble a NNEBFEZ to the refrigerated side first (Refer to pages 10-17).
- Take the second NNEBFEZ out of the carton and prepare the unit. Assemble the side brackets and center bracket to the dummy unit. Refer to page 12.
- Lay the dummy unit on the floor and position the frame so that it sits on the top flange of the fountain frame, then assemble the drip tray assembly bracket to the unit. Refer to page 11. It is recommended that the filter guard bracket is not installed in this step.
- Assemble the provided drain elbows and short drainpipe to the drip tray drain.
- Assemble the supplied P-Clip roughly 36” from the grounded plug on the supplied power cord, then secure the P-Clip to the inside surface of the horizontal strut of the fountain frame with a #8 Torx screw.
- Install the ring terminal to the inside vertical strut of the dummy unit with the provided #8 thread cutting hex screw. Screw into one of the empty flared holes of the strut.
- Disconnect the IEC connector from the power brick located behind the alcove. Set aside but do not discard the supplied power cord. Do not remove the power brick.
- Secure the wrapper assembly to the unit by inserting the 6, #8 Torx screws into the frame and side brackets. Refer to pages 15. Do not perform the steps on page 16 yet.
- Pick up the assembly by taking hold of both the fountain frame and NNEBFEZ cabinet, then hang the fountain on the wall hanging bracket. Ensure that the NNEBFEZ frame sits on top of the fountain frame. Center the cabinet on the frame.
- Ensure that the frame is flat against the wall and install your four chosen anchors (not supplied) into the wall to secure the unit. Ensure that the frame does not shift and is still centered, sitting on the frame of the cooler frame. Once secured, follow step 9 on page 16 if necessary.
- After the NNEBFEZ has been hung, the fountain frame may not properly sit back on the wall. Loosen the side screws so that the fountain may rest against the wall, then re-tighten the side screws.
- Install the provided long drainpipes to the elbow fittings of each unit. Next, install the Elkay drainpipes to connect the drains and then connect to the P-Trap. Cut provided pipes as needed.
- Connect the provided ¼” union fittings to the water-out lines of each fountain. Connect the provided ¼” water lines and sponge tubing from each kit to the fountain water out lines and install into the solenoid located on top of the alcove. Reference page 17.
- Turn on the water supply and check for leaks.
- Plug in the power cords for the refrigerated unit and the cord for the NNEBFEZ units. DO NOT plug in the dummy unit power cord. Check for any malfunctions.
- Reinstall the NNEBFEZ top panel and fountain wrappers with the appropriate screws.
Where can I find the programming options?
Refer to page 33.
What are the factory default program settings?
- Bottle Count = 0.5L (1 Bottle)
- Flow Rate = 1.2 GPM
- 20 second maximum dispense time
How do you change the program settings?
For each model top cap will need to be set aside until programming is complete. Remove top cap by unscrewing two (2) T15 torx screws if needed. Remove wire tie bundling pushbutton inside bottle filler and feed it through hole in cooler top. You can then adjust program using pushbutton through access panel of cooler.
What display actions can be performed to change the program settings?
- Home Screen: Depress button for 3 seconds to enter into the following menu settings and make changes. Note: at anytime it will exit menu and save settings when idle for 10 seconds (no button press) and revert back to Home Screen.
- LTR/GAL: Depress button 3 seconds to change from Gallons to Liters, or momentary press to advance to next menu.
- UNFILT/FILT? : Depress button 3 seconds to change from Unfiltered to Filtered unit, or momentary press to advance to next menu.
- FLOW METER? : Depress button 3 seconds to change from Rate Selected to (Flow) Meter Enabled, or momentary press to advance to next menu.
- SELECT RATE: To change flow rate, momentarily depress button to change whole gallon digit. Hold button 3 seconds to advance to TENTHS of gallon digit. Depress momentarily to change the digit. Hold button 3 seconds to advance to the next menu.
- RESET 00000000 GALLON CNT [LTR COUNT]: Depress button for 3 seconds to reset Gallon or Liter count, or momentary press to advance to next menu.
- FILT CAPAC OF 1250 GAL [4731 LTR]: Depress button for 3 seconds to change filter capacity to 3000 GAL [11355 liters] for Galaxi green filter, or momentary press to advance to next menu.
- 3 sec rule? : Depress button for 3 seconds to switch from 0.5L bottle to 3 sec rule, or momentary press to advance to next menu. (The 3 Sec rule increases the bottle count based on a 3 second dispense).
- Reset 00000000 BOT COUNT? : Depress button for 3 seconds to reset (Home Screen) BOTTLES REUSED count, or momentary press to advance to next menu.
- Bot Filler Set_time: Depress button for 3 seconds to change maximum dispense time to 10, 20 or 30 seconds, or momentary press to advance to next menu.
- RUN CAL: Depress button 3 seconds to run calibration again.