What are the main safety warnings for using the NUTONE NC1500 central vacuum?

To reduce the risk of fire, electric shock, or injury when using your NUTONE NC1500, please follow these warnings:

1. Do not use on wet surfaces or outdoors.

2. Do not vacuum liquids or fine powders (such as drywall dust).

3. Do not use to pick up flammable or combustible liquids such as gasoline or use in areas where they may be present.

4. Do not pick up anything that is burning or smoking, such as cigarettes, matches, or hot ashes.

5. Do not allow to be used as a toy. Close attention is necessary when used by or near children.

6. Use only as described in the manual. Use only manufacturer’s recommended attachments.

7. Keep hair, loose clothing, fingers, and all parts of the body away from openings and moving parts.

8. Turn off all controls before unplugging.

9. Use extra care when cleaning on stairs.

10. Do not handle plug or appliance with wet hands.

11. Do not use with a damaged cord or plug. If the appliance is not working as it should, if it has been dropped, damaged, left outdoors, or dropped into water, return it to a Service Center.

12. Keep your work area well-lighted.

13. Connect to a properly grounded outlet only. See grounding instructions.

14. When performing installation, servicing, or cleaning the unit, it is recommended to wear safety glasses and gloves.

15. When applicable local regulations comprise more restrictive installation and/or certification requirements, the aforementioned requirements prevail on those of this document and the installer agrees to conform to these at his own expense.


What cautions should I take when operating the NUTONE NC1500?

Please observe the following cautions when using your NUTONE NC1500:

1. Do not put any object into openings. Do not use with any opening blocked; keep free of dust, lint, hair, and anything that may reduce air flow.

2. Ensure air flows freely and exhausts unobstructed from the top or side outlet.

3. Do not use without a filter in place.

4. Do not use to blow leaves or debris.

5. Do not place any object on top of the unit.

6. Do not install the unit horizontally.

7. Do not use the pail as a wash bucket.

8. Do not use the pail as a stool.

9. Avoid picking up sharp objects.

10. This appliance is for use on a standard 120 VAC, dedicated 15-amp branch circuit. Some brands of house panel breakers may be more sensitive to startup current than others. In the event of nuisance tripping, after ensuring the circuit is DEDICATED to the central vacuum, we recommend changing the breaker with an “HM” type of the same AMP rating.

11. Do not unplug the unit by pulling on the cord. To unplug, grasp the plug, not the cord.

12. Store your vacuum cleaner indoors in a clean, dry area, and away from extreme temperatures.

13. Any servicing other than that recommended in this manual should be performed by an authorized service facility.

14. We recommend that your unit be inspected by a specialized technician once a year.


How should I work with the plastic tubing during the installation of my NUTONE NC1500 system?

Cutting Tubing:

Measure the length of tube needed, allowing 5/8″ for inserting into fittings and 1 1/2″ for placing into flexible tubing. Cut the plastic tubing with a hacksaw, ensuring the cut is exactly square. Use a small knife or steel wool to remove any burrs from inside the tube. Use a file to slightly bevel the outside of the tube so it slides easily into the fitting. Buff the surface to be glued with steel wool or light-grained sandpaper.

Making a Joint:

1. Insert the tube into the fitting and align the parts as they will be installed. Mark the tube and fitting to help realign the joint.

2. Apply cement in an inch-wide band to the outside of the tube.

3. Insert the tube into the fitting with the alignment marks a quarter turn apart, then quickly push and turn the fitting to align the marks and spread the cement.

4. Allow 1 minute for the joint to dry.

Cementing Flexible Tubing:

Ensure the ends of the flexible tubing are even. Apply cement to both the inside of the flexible tubing and the outside of the plastic tubing or mounting plate tubing ring. Twist both pieces while joining them to evenly spread the glue. Allow 5 minutes for the cement to set.

Secure Wire to Tubing:

The low-voltage power wiring is run along with the tubing. Use electrical tape to secure the wire to the tubing approximately every 12″ to 18″.


How do I install a wall inlet for my NUTONE NC1500 central vacuum?

1. Making the Wall Inlet Cutout:

The wall inlet should be located 18″ on-center from the floor. The wall inlet cutout must be exactly 3 7/8″ high by 2 7/8″ wide.

2. Attaching the Inlet Mounting Plate (V144):

Reach through the inlet hole, pull the flexible tubing through, and remove the low-voltage wiring from inside. Remove the nail flange from the inlet mounting plate. Apply cement to both the inside of the flexible tubing and the outside of the mounting plate’s tube ring. Insert the mounting plate’s tube ring into the flexible tubing, twisting as you join them to spread the cement. Align the mounting plate vertically. Strip the ends of the two low-voltage wires and connect them to the screw terminals on the back of the inlet cover. Assemble the inlet cover to the tube guard and mounting plate.

3. Completing the Inlet Assembly:

Once the mounting plate is attached, pull the low-voltage wire through the top wiring hole in the mounting plate.

4. Installing the Inlet (V111):

Place the inlet into the wall cutout, with the inlet cover remaining on the outside. Hold the inlet in place and gradually tighten each screw a little bit at a time.


Where is the best location to install the NUTONE NC1500 power unit?

Follow these guidelines for locating your NUTONE NC1500 power unit:

• Locate the power unit away from the general living area in an accessible location for cleaning and maintenance.

• Locate the power unit within 6 feet of a grounded electrical outlet. The unit requires a 120 VAC power source on a dedicated 15-amp branch circuit.

• Do not locate the power unit close to a source of extreme heat (e.g., water heater) or in an area with a high ambient temperature (e.g., attic, furnace room).

• If the power unit is located in a closet or a small utility room, make sure the area is well-ventilated (e.g., with door louvers).


How can I change the intake line direction on my NUTONE NC1500 power unit?

The intake line connects to the right side of the unit by default. To connect it to the left side, follow these steps:

1. Remove the debris pail from the power unit by releasing both latches on the sides of the unit, pulling them out and then pushing up.

2. For the NUTONE NC1500: Grasp the edges of the bag collar and pull down; the bag will slide off easily. Do not pull on the bag. Set the bag aside.

3. For the NUTONE NC1500: Using a Phillips no. 2 screwdriver, remove the screw tightening the bag adapter and intake elbow junction. Disassemble the bag adapter from the intake elbow and set it aside with its screw and nut.

4. All units: Disassemble the intake elbow from the back of the unit using a 3/8″ socket to remove both retaining nuts and screws.

5. All units: Flip the intake elbow 180°, then reassemble it to the unit, taking care to keep its gasket in its original position. Ensure the gasket is not folded to prevent lack of suction and noise.

6. For the NUTONE NC1500: Reassemble the bag adapter to the intake elbow. Align the triangle with the small inclined stud, then tighten the junction using the screw and nut previously removed.

7. For the NUTONE NC1500: Put the bag back in place by grasping the edges of its collar and inserting it over the bag adapter. Be careful not to tear the bag. Ensure the collar is positioned between the taper ring and the bag stopper on the bag adapter.

8. All units: Put the debris pail back in place.


How do I mount the NUTONE NC1500 power unit to the wall?

1. Carefully remove the debris pail. Make sure the bag is properly installed (if needed). Remove the installation kit and securely reinstall the debris pail.

2. Maintain minimum clearance dimensions: 12″ minimum from side walls, 12″ minimum from the ceiling, and 18″ minimum above the floor.

3. Position and install the wall mounting bracket with the provided screws. Ensure to screw the wall mounting bracket directly to a wall stud for a solid installation.

4. Use the provided mounting screws to secure the mounting bracket on the wall through the upper and lower mounting holes.

5. Hang the power unit onto the wall mounting bracket. Ensure the back brackets of the power unit are engaged with the corresponding wall bracket top fingers and lower tab. Pull the power unit down to secure.


How do I connect the main vacuum line to the NUTONE NC1500 power unit?

1. Run the house vacuum line up to the elbow behind the power unit. Insert the end of the line in the elbow opening and secure it by hand-tightening the screw and nut provided. DO NOT GLUE.

2. Assemble exhaust tubing to the exhaust outlet on the top or top side of the unit, according to the power unit model. DO NOT GLUE.

3. Make sure all tubing connections are airtight.

4. The exhaust should not be vented into a wall, ceiling, or concealed space in the house. It is recommended to vent the vacuum exhaust air to the outdoors. An exterior vented exhaust line should end using a Model V145 wall cap. For optimal indoor air quality, exhausting the power unit to the outdoors is recommended but is not required.


What are the proper grounding and wiring instructions for the NUTONE NC1500?

Grounding Instructions:

Improper connection of the equipment-grounding conductor can result in a risk of electric shock. This appliance must be grounded. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances. Check with a qualified electrician or service person if you are in doubt as to whether the outlet is properly grounded. Do not modify the plug provided with the appliance – if it will not fit the outlet, have a proper outlet installed by a qualified electrician.

Wiring:

The NUTONE NC1500 is for use on a standard 120 VAC, dedicated 15-amp branch circuit with a NEMA 5-15R receptacle. Make sure the power unit is connected to an outlet that has a grounding attachment plug that looks like the one shown in the manual. No adapter should be used. Inlet leads are to be connected to the power unit low voltage tabs using crimp connectors (included in the parts bag) and the low voltage harness.


How do I operate the NUTONE NC1500 central vacuum system?

Open the wall inlet cover and insert the end of the hose into the inlet to turn on the vacuum.

For non-switched hoses, inserting the hose automatically turns on the power unit; removing the hose shuts off the power unit. Some hoses have switches which can be used to activate the power unit. The ON/OFF switch located on the power unit needs to be kept in the OFF position.

As you vacuum, dirt and dust are carried to the power unit where they remain in a bag or in the debris pail.

Use the cleaning tools as you would for any other vacuum cleaner. Avoid picking up very large or lengthy debris as these kinds of objects may become lodged in the hose or tubing.


When should I change the bag on my NUTONE NC1500?

With a 6 U.S. gallons (22.7 liters) capacity, under normal conditions the bag requires changing approximately twice a year. If the bag is full, you will notice a reduced suction from the system. Unless this loss of suction is caused by a blockage, changing the bag will solve the problem.

NOTE: Even if not filled to capacity, if the bag seems tightly stretched when removing the debris pail, changing the bag will prevent it from tearing.


How do I replace the disposable bag in my NUTONE NC1500?

1. To remove the disposable bag, release both latches on the sides of the unit by pulling them out and then pushing up. Remove the pail from the unit. Grasp the edges of the bag collar and pull down. The bag will slide off easily. Do not pull on the bag.

2. Unfold the new bag.

3. Grasp the collar where indicated on the new bag and insert it over the bag adapter. Be careful not to tear the bag. Ensure the collar is positioned between the taper ring and the bag stopper on the bag adapter. Put the pail back in its place.


How do I maintain the motor foam filter on my NUTONE NC1500?

The NUTONE NC1500 has a motor foam safety filter located at the top of the vacuum chamber. It provides protection against dirt being pulled into the motor if the disposable bag should accidentally be torn. This filter should be checked and cleaned if necessary when a replacement bag is installed.

To clean, simply brush the filter clean. If the filter is excessively soiled, hand wash it in a water and mild detergent solution, rinse, and let it dry completely on a flat surface before reinstalling.

CAUTION: Operating the power unit without the motor foam filter will void the warranty.

Removing the Motor Foam Filter:

Remove the debris pail and disposable bag. Lift the center of the wire retaining the motor foam filter and slide the filter out of its location.

Reinstalling the Motor Foam Filter:

To reinstall the filter, reverse the steps described above.


How do I install the hose hanger for my NUTONE NC1500 accessories?

1. Secure the hose hanger to the wall using the 2 provided screws. Depending on the chosen location, you may need to use wall anchors (not included).

2. Wind the hose around its hanger when not in use.


How do I install the wand hanger for my NUTONE NC1500 accessory kit (if applicable)?

1. Secure the wand hanger to the wall using the 2 included screws. Depending on the wall surface, the use of wall anchors (not included) may be necessary.

2. Push the wand in its hanger when not in use for storage.


How do I connect the various hoses to a wall inlet for my NUTONE NC1500?

Low Voltage Hose:

To ensure proper operation, insert the hose into the wall inlet. Align the tab on the hose up with the depression in the wall inlet (A).

Dual Voltage Hose (Electric Kits Only):

In addition to connecting into the wall inlet (A), the dual voltage hose must also be connected to a standard electrical outlet (B).


How does the operating switch on the handle work for NUTONE NC1500 hoses?

Low Voltage Hose:

The switch will turn the power unit ON (I position) and OFF (O position).

Dual Voltage Hose:

• Switch on II position: Central vacuum mode with power brush.

• Switch on I position: Central vacuum mode without power brush.

• Switch on O (center) position: Power unit is turned OFF.


How do I assemble the power brush accessory for my NUTONE NC1500 electric kit?

1. Read important safety instructions before installing the power brush.

2. Ensure the hose is disconnected from the power supply before installing the power brush.

3. Push the wand into the power brush neck so that the lock button snaps in place.

4. Connect the hose handle into the wand quick connector and ensure that the prongs are aligned with the receptacle holes. Push until the lock button snaps in place.

CAUTION: Always check the underside of the product for any obstructions prior to use.

WARNING: Never leave the electric power brush unattended while it is plugged in.


How do I use the various features of the power brush and wand with my NUTONE NC1500?

CAUTION: Always pick up hard or sharp objects by hand before using your power brush. Items such as pins, hairpins, tacks, crayons, etc., may damage the brush roll or may break the belt.

Wand Release: The power brush is not recommended for use on bare floors. The wand release pedal (A) allows you to quickly disconnect the wand and switch to a combination floor/rug tool for use on bare floors.

Power Brush Neck Release: Push down the power brush neck release pedal (B) to unlock the brush neck. Return the neck to the upright position for storage. Always unlock the brush neck before use.

Power Brush Height Adjustment: Select the carpet pile height by depressing the height adjustment pedal (C) to the desired position: Extra-Low, Low, Medium, or High.

Wand Length Adjustment: Extend or shorten the wand to a comfortable working position by holding the wand grip (G) in one hand and sliding the upper section (with the prongs) with the other hand.

Edge Cleaner: The brush extends the full width for effective edge cleaning. To operate, simply run the cleaner along the edge board.


What should I do if the electronic circuit breaker on my NUTONE NC1500 power brush trips?

The power brush is equipped with an electronic circuit breaker that protects the motor and belt if a large object is picked up. If the power brush stops while vacuuming, follow these steps:

1. Turn the power unit off using the handle.

2. Release the power brush from the wand and turn it over to see if there is an obstruction.

3. Once the brush roll jam has been cleared, press the reset button (H) and connect the power brush back to the wand.

4. Turn the power unit/power brush back on.

If it fails to restart or continues to trip without any apparent reason, the power brush must be serviced by an authorized service center.


How do I clean and store the power brush accessory for my NUTONE NC1500?

WARNING: Disconnect the electrical supply before servicing or cleaning the unit. Failure to do so can result in electrical shock or personal injury from the cleaner suddenly starting.

Brush Roll Cleaning:

To maintain high cleaning efficiency, the brush roll must be cleaned every time the belt is changed. It should also be cleaned according to the following schedule:

• Heavy use (daily): Clean every week.

• Moderate use (2-3 times per week): Clean every month.

• Light use (once a week): Clean every 2 months.

Check and remove hair, string, and lint build-up frequently in the brush roll and end cap areas.

Housing Cleaning:

To keep the power brush housing clean, wipe it with a damp cloth and a mild soap solution, then dry thoroughly. Never use any type of chemical as it can damage the housing.

Storage:

1. Ensure the hose and power cord are disconnected from the wall inlet before unplugging the power brush.

2. Disconnect the hose handle from the wand.

3. Always keep the hose neatly coiled when not in use.

4. When not in use, the power brush should be stored in a clean, dry place.


How do I change the belt on the power brush for my NUTONE NC1500?

WARNING: Disconnect the electrical supply before servicing or cleaning. The motor shaft can become hot during normal use; avoid touching it to prevent burns.

1. Turn the power brush over and, using a Phillips no. 2 screwdriver, remove the 3 brush roll cover retaining screws and set them aside.

2. Remove the brush roll cover.

3. To free the brush roll from the base, start by sliding the belt side end and pull the brush roll sideways (1). Once disengaged from the housing, lift the brush roll (2) out of its compartment.

4. Disengage the brush roll from the worn belt and extract the belt from the motor shaft by a twisting motion in the enlarged area (I) specifically made for that purpose.

5. Install the new belt by reversing steps 4 to 1. To ease belt replacement, start by inserting one end around the motor shaft in the enlarged area (I). Insert the brush roll through the belt until the belt is seated in its place. Push the brush roll back in place.


How do I change the brush roll on the power brush for my NUTONE NC1500?

Replace the brush roll when its bristles are worn to the base support bars level.

1. Turn the power brush over and, using a Phillips no. 2 screwdriver, remove the 3 brush roll cover retaining screws and set them aside.

2. Remove the brush roll cover.

3. To free the brush roll from the base, start by sliding the belt side end and pulling the brush roll sideways (1). Once disengaged from the housing, lift the brush roll (2) out of its compartment.

4. Disengage the brush roll from the belt. Discard the worn brush roll.

5. Insert the new brush roll through the belt until the belt is seated in its place. Push the brush roll back in place.

6. Finalize the installation by reversing steps 3 to 1.


What should I do if my NUTONE NC1500 experiences a loss or decrease of suction?

If you experience a loss of suction, check the following possible causes and remedies:

Possible Cause: Debris pail or disposable bag is completely full.

Remedy: Change the disposable bag as described in the manual.

Possible Cause: Debris pail gasket damaged or missing.

Remedy: Replace the debris pail gasket.

Possible Cause: Obstruction in the hose.

Remedy: Determine if the hose is blocked by checking suction at various wall inlets. If the hose is blocked, disconnect it and insert a blunt instrument (like a flexible garden hose) to push the obstruction through.

Possible Cause: Obstruction in the tubing system inside the walls.

Remedy: Insert the hose end into any inlet to run the power unit. Place the palm of your hand over the opposite end of the hose. When you feel suction increase, hold your hand over the end for a few seconds and then quickly remove it. Repeat this procedure several times. If the blockage is not cleared, contact your nearest Service Center.

Possible Cause: Disposable bag is torn.

Remedy: Clean the interior of the unit and install a new disposable bag.

Possible Cause: Wall inlet cover not properly sealed.

Remedy: Check all wall inlet covers to be sure they are closed and sealed tightly.

Possible Cause: Exhaust tubing or vent is clogged.

Remedy: Inspect and remove any blockages.


What should I do if my NUTONE NC1500 power unit does not start or stops suddenly?

If your power unit fails to start or stops suddenly, check these possible causes and remedies:

Possible Cause: Defective inlet.

Remedy: Check other wall inlets. If others work, replace the defective wall inlet.

Possible Cause: Power unit internal circuit breaker has been activated (the reset button is popped up).

Remedy: Push on the circuit breaker reset button located on the left side of the power unit. If this button pops up again, contact your authorized Service Center.

Possible Cause: Blown fuse or tripped circuit breaker on the house electrical panel.

Remedy: Replace the fuse or reset the circuit breaker. Ensure the circuit is DEDICATED to the central vacuum unit. Some brands of house panel breakers may be more sensitive to startup current; you can correct this by changing the breaker with an “HM” type of the same AMP rating.

Possible Cause: Defective hose.

Remedy: Replace the hose as required.

Possible Cause: Power unit overcurrent protector has been activated.

Remedy: Unplug the power unit, wait at least 15 minutes, and plug the power unit back in.


What should I do if my NUTONE NC1500 power unit runs continuously when the hose is removed?

If the power unit continues to run after removing the hose, check the following:

Possible Cause: The unit power switch is in the ON position.

Remedy: Set the unit power switch to the OFF position.

Possible Cause: An electrical short has occurred somewhere in the system.

Remedy: Perform a complete check of all wall inlets and power unit low voltage control lead connections. Contact your authorized Service Center.


What are the main service parts for the NUTONE NC1500 power unit?

When ordering service parts, please use the Part No., not the Key No.

KEY NO.PART NO.DESCRIPTION
1S10941411TOP CAP ASS’Y
366369MOTOR FOAM FILTER WITH FASTENER
4S10941400GASKET
6S99670648DEBRIS PAIL (INCLUDING KEY NO. 7)
7S10941199LATCH AND SCREWS
8S10941404LATCH KEEPER WITH SCREWS
9S10941405BAG ADAPTER WITH NUT AND SCREW
11S10941406INTAKE ELBOW WITH GASKET, SCREWS, AND NUTS
12S99670650EXHAUST PORT WITH GASKET AND SCREWS
13S30390555UNIT SUPPORT BRACKET
*391CDISPOSABLE BAG (SET OF 3)