What should I do before servicing or cleaning the NUTONE 765HL ventilation fan?

Before servicing or cleaning the NUTONE 765HL unit, switch power off at the service panel. Lock or tag the service panel to prevent power from being switched on accidentally.


How should the NUTONE 765HL be used in relation to fuel burning equipment combustion?

Provide sufficient air for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the combustion equipment standards such as those published by the National Fire Protection Association (NFPA), the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and local codes.


What should be done if electrical wiring or other hidden utilities are damaged while cutting or drilling for the NUTONE 765HL installation?

When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.


Where must ducted fans for the NUTONE 765HL be vented?

Ducted fans must always be vented to the outdoors.


What is required for the power supply of the NUTONE 765HL?

Provide a separate 20 AMP circuit. Use 12 GA., 90° C minimum power cable which meets code.


Can a speed control be used with the NUTONE 765HL?

Do not use a speed control with this product.


What is required regarding grounding for the NUTONE 765HL?

This unit must be grounded.


For what use should the NUTONE 765HL be used only?

For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.


Where must the NUTONE 765HL product be mounted?

THIS PRODUCT MUST BE MOUNTED IN A FLAT CEILING ONLY. Installations in ceilings 9-feet high or less will provide maximum comfort. DO NOT MOUNT THIS PRODUCT IN A WALL.


What is the required distance from any wall when installing the NUTONE 765HL in the ceiling?

Install in ceiling only at least 6 inches from any wall.


How can motor bearing damage and noisy, unbalanced impellers be avoided during the installation of the NUTONE 765HL?

To avoid motor bearing damage and noisy, unbalanced impellers, keep drywall spray, construction dust, etc. off motor and impeller.


How do I clean the NUTONE 765HL for quiet and efficient operation?

For quiet and efficient operation, long life, and attractive appearance – lower or remove grille and vacuum interior of fan with a dusting brush attachment.


What should be done if the motor bearings of the NUTONE 765HL make excessive or unusual noise?

If the motor bearings make excessive or unusual noise, replace the motor with the exact service motor. The impeller should also be replaced.


What type and maximum wattage bulb should be used to replace the light bulb in the NUTONE 765HL?

Replace light bulb with a 100-Watt (maximum) incandescent light bulb.


How is the heater, fan, and light operated on the NUTONE 765HL?

Use a 3-Function Control to operate the heater, fan, and light separately. See “Connect Wiring” for details.


What is the recommended location for the NUTONE 765HL unit installation regarding duct runs?

The unit will operate most quietly and efficiently when located where the shortest possible duct run and minimum number of elbows will be needed.


What type of cap should be used for the NUTONE 765HL to reduce backdrafts?

Use a roof cap or wall cap that has a built-in damper to reduce backdrafts.


How should the hanger bars be inserted into the NUTONE 765HL housing during installation?

Slide hanger bars into channels on housing. Make sure hanger bar tabs face “up” as shown.


How far can the sliding hanger bars for the NUTONE 765HL housing extend?

Four (4) sliding hanger bars are provided to allow for accurate positioning of housing anywhere between framing. They can be used on all types of framing (I-joist, standard joist, and truss construction) and span up to 24″.


How should the damper/duct connector be attached to the NUTONE 765HL housing?

Snap damper / duct connector onto housing. Make sure connector is flush with top of housing and damper flap falls closed.


How should the 4-inch round ductwork be connected to the NUTONE 765HL?

Connect 4-inch round ductwork to damper / duct connector. Run ductwork to a roof cap or wall cap. Tape all ductwork connections to make them secure and air tight.


How should the hanger bars be secured to the framing when mounting the NUTONE 765HL housing?

Extend hanger bars to the width of the framing. Hold fan in place with the hanger bar tabs wrapping around the bottom edge of the framing. Nail fan to framing or fasten with screws (not provided) through holes near nails.

To ensure a noise-free mount: Secure hanger bars together with screws or use a pliers to crimp mounting channels tightly around hanger bars.


What is the procedure for plugging in the light for the NUTONE 765HL grille assembly?

Hold grille assembly up near housing. Connect light plug from grille assembly to receptacle inside of housing.


How is the grille attached to the NUTONE 765HL?

Place grille/reflector combination over protruding screw and fasten in place using acorn nut provided. HAND TIGHTEN acorn nut 1/4 turn after it is snug.


What is the maximum wattage incandescent bulb accepted by the NUTONE 765HL unit?

The unit accepts a 100-Watt (maximum) incandescent bulb.


How is the light lens removed from the grille of the NUTONE 765HL?

Insert a small flat-bladed screwdriver into the slot at one end of the light lens. Carefully pry the lens out.


How is the light lens attached back onto the grille of the NUTONE 765HL?

Hook the tabs on one end of the lens into the slot in the grille. Lift other end of lens up and snap into place.


How do you direct the heat from the heater grille on the NUTONE 765HL?

Use a flat-bladed screwdriver to rotate the round heater grille to provide heat in the desired direction.


What is the nominal capacity rating for each two-position rocker switch controlling the NUTONE 765HL?

Each two-position rocker switch is rated 15 A @ 120VAC. The total load on this control must not exceed 20 A @ 120VAC.


What wiring connections should be made between the wiring plate and the ventilator housing for the light function on the NUTONE 765HL?

Connect RED (Light) on the wiring plate to BLUE (Light) on the ventilator housing.


What wiring connections should be made between the wiring plate and the ventilator housing for the fan function on the NUTONE 765HL?

Connect BLACK to BLACK (Fan) on the wiring plate to BLACK on the ventilator housing.


What wiring connections should be made between the wiring plate and the ventilator housing for the heat function on the NUTONE 765HL?

Connect BLACK to RED (Heat) on the wiring plate to RED on the ventilator housing.


What are the specified wire color connections for the ground on the NUTONE 765HL?

Connect GROUND on the wiring plate to GREEN on the ventilator housing.


What are the wire color connections for the white neutral wires on the NUTONE 765HL?

Connect WHITE to WHITE (Neutral) from the ventilator to WHITE on the wiring plate, and WHITE to WHITE on the ventilator housing.


What is the general instruction for connecting house wiring to the wiring plate of the NUTONE 765HL?

Run 120 VAC house wiring to installation location. Use proper UL approved connectors to secure house wiring to wiring plate. Connect wires as shown in wiring diagram(s).


What step is performed after installing the electrical wiring for the NUTONE 765HL?

Finish ceiling. Install ceiling material. Cut out ceiling material closely around housing.


What is the span capability of the hanger bars provided for the NUTONE 765HL housing?

The hanger bars can be used on all types of framing (I-joist, standard joist, and truss construction) and span up to 24″.


What connection must be made between the 4-inch round ductwork and the NUTONE 765HL damper/duct connector?

Connect 4-inch round ductwork to damper / duct connector.


What is the maximum on-center span for mounting the housing of the NUTONE 765HL to joists, trusses, or I-joists?

Housing mounted to joists, trusses, or I-joists. Up to 24-inches on-center.


What wiring connections are required for a double-gang switch box controlling the NUTONE 765HL?

The following connections are shown for a double-gang switch box:

LINE IN GRD GRD
INTERRUPTOR DEL VENTILADOR (Fan Switch) NEGRO NEGRO BLANCO
INTERRUPTOR DE LUZ (Light Switch) NEGRO ROJO BLANCO
INTERRUPTOR DEL CALEFACTOR (Heat Switch) NEGRO NEGRO BLANCO

The UNIT side connections are:

LUZ BLANCO AZUL ROJO
VENTILADOR BLANCO NEGRO NEGRO
CALOR BLANCO NEGRO ROJO

What must be done to secure and make the ductwork connections airtight for the NUTONE 765HL?

Tape all ductwork connections to make them secure and air tight.


What should be done after installing the ceiling material around the NUTONE 765HL housing?

Install ceiling material. Cut out ceiling material closely around housing.