Free English NEMCO 9122A-1 (01) PDF document. Download the PDF, use the online viewer, or browse the FAQs for easy troubleshooting.
CLICK HERE TO DOWNLOAD NEMCO 9122A-1 (01) PDF DOCUMENT
If this is not the document you want for this product, click here to see if we have any other documents for this product.
What are the important safety instructions for the NEMCO 9122A-1?
When using electrical appliances, basic safety precautions should be followed, including the following:
Warning – To reduce the risk of burns, electric shock, fire, injury to persons, or exposure to excessive electromagnetic energy:
1) Read all instructions before using the appliance.
2) Read and follow the specific “PRECAUTIONS TO AVOID POSSIBLE ELECTRIC SHOCK”.
3) This appliance must be grounded. Connect only to properly grounded outlet. See “GROUNDING INSTRUCTIONS”.
4) Use this appliance only on the specified electrical circuit.
5) Install or locate this appliance only in accordance with the provided installation instructions.
6) Do not heat any sealed cans on the induction range. A Sealed can may explode.
7) Use this appliance only for its intended use as described in the manual. Do not use corrosive chemicals or vapors on this appliance.
8) As with any appliance, close supervision is necessary when used by or around children.
9) Do not operate this appliance if it has a damaged cord or plug, broken or cracked glass surface, if it is not working properly, or if it has been damaged or dropped.
10) This appliance should be serviced only by qualified service personnel. Contact Nemco for the authorized service facility for examination, repair or adjustment.
11) Do not cover or block any openings on the appliance. Allow 4″ clearance from all vent openings.
12) Do not place the range in, on or near open flames, electric burners, ovens or other high temperature surroundings.
13) Do not move the range while cooking or while hot.
14) Do not store this appliance outdoors. Do not use this product near water – for example, near a kitchen sink, in a wet basement, near a swimming pool, or similar locations.
15) Do not immerse cord or plug in water.
16) Keep cord away from heated surfaces.
17) Do not let cord hang over edge of table or counter.
18) When cleaning, use only mild, nonabrasive soaps or detergents applied with a sponge of soft cloth.
19) Do not clean with metal scouring pads. These will scratch and damage the glass and control surfaces.
20) Do not touch the hot surface of the glass cooktop.
21) Do not heat empty pots/pans. Using an empty pan can result in extremely high temperatures that may damage the pan and the range.
22) Keep pacemakers at least 2 feet from the cooktop.
What are the functions of the controls on the NEMCO 9122A-1?
The control panel on your NEMCO 9122A-1 includes the following features:
Display: Shows power level, time, and error codes.
Power On/OFF: The red button turns the unit on and off.
Start/Stop: Starts or stops the heating cycle.
Mode: Button for selecting control modes (Note: Temperature control mode is not available on this model).
Min/Sec: Button used for setting the timer in minutes and seconds.
Timer: Button to activate the timer setting mode.
Multi-Purpose Knob: Used to adjust power levels and timer settings.
What happens if I remove a pan or the NEMCO 9122A-1 overheats?
The NEMCO 9122A-1 has several safety features:
No Pan Detection: The range will not operate without an appropriate pan on the cooktop. The display will flash ‘00’ indicating no pan is present. If the pan is removed during cooking, the unit will turn off after about 40 seconds. To resume cooking, place the pan back on the cooktop and press the ‘Start/Stop’ button.
Overheat Protection: If the cooktop temperature reaches 260° C or 500° F, the unit turns off automatically and displays an error code. This can happen if a pan is empty or boils dry. Allow the unit to cool off, then restart by pressing the power on/off button.
Voltage/Current Protection: If the voltage or current is abnormal, the unit will shut itself off and display an error code.
Small Object Detection: Small objects like a knife or spoon will not be “seen” as a valid pan, and the range will not operate. Do not place items other than induction cookware on the range surface.
How do I operate the NEMCO 9122A-1 induction range?
1. Plug the unit into the appropriate power outlet. The display will show four red dots.
2. Press the red power on/off button. The display will show ‘00’ and the unit is now in the ready state.
3. Place an appropriate pan on the glass cooktop, centering it on the target.
4. Press the ‘Start/Stop’ button. The display will show ‘5’ or ‘6’, and the fan will start. The range is now cooking at the displayed power level.
5. Rotate the knob to the right to increase the power setting.
6. Rotate the knob to the left to decrease the power level.
7. The power for the NEMCO 9122A-1 will adjust from H1 to H7 (hold settings) and 1 to 10 (cooking settings). Power levels H1 thru H7 are designed to keep food warm at a constant temperature. Power levels 1 thru 10 are for cooking and deliver continuous power similar to a gas flame.
8. While cooking, press the ‘Start/Stop’ button or remove the pan to stop the cooking cycle. If the pan is removed and replaced within approximately 40 seconds while ’00’ is flashing, the system will automatically resume heating. After 40 seconds with no pan, the display will show a steady ’00’.
9. The power level can be adjusted ‘on the fly’ at any time while the unit is heating.
10. When the unit is turned off using the Power On/Off button, the cooling fan may continue to run for a short period.
11. Do not unplug the unit until the fan has stopped running.
Are there any power setting recommendations for cooking with the NEMCO 9122A-1?
The best power settings will vary. Until you get a ‘feel’ for the unit, you should start at medium settings of 5 or 6 and adjust up or down from there. You can use the following as a starting guide:
1. Stir Fry: Quickly stir fry on high heat settings of 8 to 10.
2. Boil Water: Boil water on high heat settings of 9 or 10, then reduce to level 5 or 6 to maintain a hard boil. Reduce to 3 or 4 for a slow boil.
3. Pan Fry: Pan fry on medium to high heat settings of 5 to 10.
4. Sauté/Simmer: Use medium to low settings 3 to 5.
5. Warming: Hold food at serving temperatures using setting 2. Results will vary depending on the volume of food being held.
6. Chocolate Melting: Use setting 1.
How do I use the Temperature Control Mode on my NEMCO 9122A-1?
Temperature control mode is not available on the NEMCO 9122A-1. If you press the ‘Mode’ button the display will show ‘000F’, but it will have no effect on the operation of the unit. Pressing the ‘Start/Stop’ button in this mode will result in an ‘E5′ error message after a few seconds. Press the red ‘Power’ button to turn the unit off and clear the error message.
How do I set the timer on the NEMCO 9122A-1?
The timer can be set from 1 second up to 719 minutes. The timer resets to 719 minutes every time the power is turned off/on. If the unit runs continuously for 12 hours (719 minutes), the timer will run out and the unit will turn off.
Setting the Timer:
• With the unit powered on and in the Ready state (display shows a steady ’00’), press the ‘TMR’ button. The display will show ‘0719′.
• To change the timer setting, press the ‘MIN/SEC’ button. The display will flash ‘719’.
• Turn the knob to adjust the number of minutes. Turning left reduces minutes. Turning right past 719 will switch to seconds, displaying ‘00.59’.
• To set both minutes and seconds (e.g., 3 minutes and 30 seconds), turn the knob until the display shows ‘03.59’. Press the ‘MIN/SEC’ button again. The ‘seconds’ field will flash. Use the knob to adjust the seconds to 30. The display will show ‘03.30’.
• When the time is set, press the ‘Start/Stop’ button. The power will come on and the timer will count down. When the timer reaches 0, the unit will stop heating.
• While heating, the display alternates between the timer and the power setting. You can adjust the power setting when the power level is displayed.
• Press the TMR button while heating to stop the alternating display. The timer will continue to run. Press the TMR button again to resume the alternating display.
• While heating, the timer display decimal points will flash.
• Once the timer counts down to zero, pressing the ‘Start/Stop’ button will restart the cycle at the time you set previously. Turning the unit off/on using the ‘Power’ Button will reset the timer to 719 minutes.
How should I clean the NEMCO 9122A-1?
After the induction range has cooled down, clean as follows:
Glass Cooktop: Wipe with a damp cloth or use a mild, non-abrasive cleaning solution.
Control Panel: Wipe with a damp cloth only. Do not spray with cleaning solutions! Do not use sharp or metal objects to press the buttons! Only press the buttons using your finger!!
DO NOT USE SHARP OBJECTS OR ABRASIVES ON THE GLASS COOKTOP. SCRATCHES IN THE GLASS CAN WEAKEN IT AND LEAD TO BREAKAGE!
What are the cookware requirements for the NEMCO 9122A-1?
Cooking with the NEMCO 9122A-1 requires the use of induction compatible pots/pans. In general this means that the vessel must be magnetic. If a magnet sticks to it, it will probably be a good Induction pan. Other things to consider are:
Size and Shape: Pans should have a minimum bottom diameter of 4.75 inches, and the bottom of the pan should be flat within about 1/8 of an inch. For best results, the maximum bottom diameter of the pan should not exceed 10.25 inches.
Incompatible Materials: Materials that will NOT work with induction ranges include glass, ceramics, earthenware, bronze, copper, aluminum or 300 series stainless steel.
To Test a Pan: Put it on the range, press the Start button and increase the power level. If the display flashes ’00’ the pan is not compatible with induction cooking.
What are the product specifications for the NEMCO 9122A-1?
| Model | Frequency | Voltage | Amps | Power | Weight | Dimensions |
|---|---|---|---|---|---|---|
| 9122A-1 | 50/60Hz | 208 or 240 | 15 | 3500 W | 14 lbs. | L 14 9/16″ W 11 5/8″ D 3 1/8″ |
What are the installation guidelines for the NEMCO 9122A-1?
Always ensure that the glass surface of the range is mounted FLUSH with the counter top. The exposed edge of the glass is fragile and can be easily chipped or broken by side impact.
If flush mounting is not feasible, you can purchase the optional Stainless Steel Trim Ring. This allows you to make a simple cut-out in the counter top, and the Trim Ring supports the unit and protects the glass edge from damage.
With either mounting method, seal around the unit (and Trim Ring) with silicone caulking to keep liquids from penetrating and getting below the surface.
If the units are mounted in a closed cabinet, you must ensure that there is adequate air flow. Each unit draws in cooling air from the back, and exhausts warm air from the front. In a closed cabinet you must provide adequate openings for both the intake and the exhaust air.
How do I troubleshoot error codes on the NEMCO 9122A-1?
| Flashing Display Indication | Cause | Solution |
|---|---|---|
| U | No pan or non-induction pan | Place an appropriate pan on the cooktop target |
| 1 | Over current | Check for abnormal conditions like water, moisture or broken parts or cord. Unplug the unit. Plug it back in. If the error continues, contact customer service. |
| 2 | Over Voltage | Check to verify that the outlet voltage is correct and within limits. Unplug the unit. Plug it back in. If the error continues, contact customer service. |
| 3 | Under Voltage | Check to verify that the outlet voltage is correct and within limits. Unplug the unit. Plug it back in. If the error continues, contact customer service. |
| 4 | Main Heat Sink Over Temp | Check to verify that the fans are working. Check to make sure the air flow is unrestricted. |
| 5 | External Temp. Probe problem | Temp mode not available on BKT series. |
| 6 | Pan is Overheated | Make sure the pan is not empty. Allow the unit to cool down. |
| 7 | Power Frequency is Unstable | Check the incoming power for frequency stability. Unplug the unit. Plug it back in. If the error continues, contact customer service. |
| 8 | OP Amp Offset Error | Unplug the unit. Plug it back in. If the error continues, contact customer service. |
| 9 | Main Coil Overcurrent | Unplug the unit. Plug it back in. If the error continues, contact customer service. |
What are the part numbers for the main components of the NEMCO 9122A-1?
| Model | Main PCB | Coil | Control Board | Filter PCB | Fan | Ferrite Bead | Glass | Overlay |
|---|---|---|---|---|---|---|---|---|
| 9122A-1 | 48858A | 48866 | 48871A | 48860 | 48879 | 48881 | 69508 | 48920 |
How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.
CLICK HERE TO DOWNLOAD NEMCO 9122A-1 (01) PDF DOCUMENT