Free English MOTOROLA NURSERY PIP15-4 MULTI (01) PDF document. Download the PDF, use the online viewer, or browse the FAQs for easy troubleshooting.


CLICK HERE TO DOWNLOAD MOTOROLA NURSERY PIP15-4 MULTI (01) PDF DOCUMENT

If this is not the document you want for this product, click here to see if we have any other documents for this product.

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

How long should I charge the MOTOROLA NURSERY PIP15-4 MULTI before initial use?

You should charge both the parent unit and baby units for 16 hours before initial use. When charging for the first time, charge for at least 16 hours continuously.


Where should I place the baby unit of the MOTOROLA NURSERY PIP15-4 MULTI?

Determine a location for the baby unit that will allow you to hear your baby in his/her cot.

Place the baby unit on a flat surface, such as a dresser, bureau, or shelf.

NEVER place the baby unit or cords within the cot.

Place your units within reach of the AC power outlet and wall socket.

The units and cords should be more than 1 meter (3 feet) away from the babies.

Make sure there is a minimum distance of 2 meters (6 feet) between the parent and baby units to avoid audio feedback.


How do I install the batteries into the baby unit of the MOTOROLA NURSERY PIP15-4 MULTI?

Lift up the battery cover to remove it from the baby unit.

Insert the rechargeable Ni-MH battery cells supplied. Note the ’+’ and ’-’ markings beside the battery compartment and insert in the correct direction.

Place the battery cover back into place.

Warning! Use only the approved rechargeable Ni-MH battery cells (2 x AAA Ni-MH rechargeable batteries) supplied with your product.


How do I connect and charge the baby unit of the MOTOROLA NURSERY PIP15-4 MULTI?

Plug the supplied USB type-C cable into the USB-C power socket.

Plug the USB-C power socket cable into the power jack on the side of the unit and plug the other end into the wall socket.

Switch on the AC power (if your AC power outlet has a switch). The battery charging LED indicator will light up in red and turn dim when the batteries are fully charged.


How do I install the batteries into the parent unit of the MOTOROLA NURSERY PIP15-4 MULTI?

Lift up the battery cover to remove it from the parent unit.

Insert the rechargeable Ni-MH battery cells supplied. Note the ’+’ and ’-’ markings inside the battery compartment and insert in the correct direction.

Place the battery cover back into place.

Warning! Use only the approved rechargeable Ni-MH battery cells (2 x AAA Ni-MH rechargeable batteries) supplied with your product.


How do I connect and charge the parent unit of the MOTOROLA NURSERY PIP15-4 MULTI?

Plug the supplied USB type-C cable into the USB-C power socket.

Plug the USB-C power socket cable into the power jack on the side of the parent unit and plug the other end into the wall socket.

Switch on the AC power (if your AC power outlet has a switch). When the parent unit is fully charged, the battery icon will appear steadily on the screen display.


What does the battery low warning indicate on the MOTOROLA NURSERY PIP15-4 MULTI?

On the baby units, if the battery charging LED indicator flashes red when turning on the power button, it means the battery level is low and needs recharging.

On the parent unit, if the battery icon flashes on the screen display when turning on the power button, it means the battery level is low and needs recharging.


How do I turn the baby unit of the MOTOROLA NURSERY PIP15-4 MULTI on and off?

To turn on: Press and hold the power button on the baby unit. The power LED indicator lights up in red first and becomes green.

To turn off: Press and hold the power button on the baby unit again. The power LED indicator will turn off.


How do I turn the parent unit of the MOTOROLA NURSERY PIP15-4 MULTI on and off?

To turn on: Press and hold the power button on the parent unit. The power / linking LED indicator lights up in green.

To turn off: Press and hold the power button on the parent unit again. You will hear a beep sound. The power / linking LED indicator will turn off.


How do I adjust the speaker volume on the MOTOROLA NURSERY PIP15-4 MULTI parent unit?

Press the Up or Down arrow buttons to increase or decrease the volume. It has 5 volume levels and mute.


How do I use the Talk Back feature on the MOTOROLA NURSERY PIP15-4 MULTI?

Press the microphone button continuously on the parent unit to select an individual baby unit or all baby units. Then the screen will display the microphone icon with the baby unit number(s) selected.

Press and hold the talk back button, and speak to your baby/babies through the microphone of the parent unit.

Release the button when you finish speaking.

In standby mode, press and hold the talk back button to speak directly to all babies.


How do I name the baby units on the MOTOROLA NURSERY PIP15-4 MULTI?

1. Press MENU then scroll up/down to select NAME, then press OK.

2. Scroll up/down to select a baby unit, then press OK.

3. Scroll left or right to select a character on the screen, then press OK to confirm. The character will be added.

4. To remove a character, scroll left or right to select X and press OK.

5. Repeat the same process until you finish editing. The maximum number of characters is limited to 5.

6. Scroll left or right to select the checkmark symbol to save the name.

7. To name another baby unit, repeat from step 1.


How do I register a new baby unit to the MOTOROLA NURSERY PIP15-4 MULTI parent unit?

1. Make sure the baby unit is switched off.

2. Press and hold the power button on the baby unit until you hear a beep tone and the LED on the baby unit flashes. The baby unit enters pairing mode.

3. On the parent unit, press MENU then scroll up/down to REGISTER.

4. Press OK then scroll up/down to PAIR.

5. Press OK to confirm. When pairing is successful, SUCCEED will appear on the screen and you will hear a beep tone.


How do I deregister a baby unit on the MOTOROLA NURSERY PIP15-4 MULTI?

1. On the parent unit, press MENU then scroll up/down to REGISTER.

2. Press OK then scroll up/down to UNPAIR.

3. Press OK then scroll up/down to select a baby unit.

4. Press OK to confirm. When unpairing is successful, SUCCEED will appear on the screen and you will hear a beep tone.


How do I reset the MOTOROLA NURSERY PIP15-4 MULTI baby monitor?

1. Press MENU then scroll up/down to RESET.

2. Press OK two times to confirm.


How do I change the temperature format on the MOTOROLA NURSERY PIP15-4 MULTI?

1. Press MENU then scroll up/down to TEMPERATURE.

2. Press OK then scroll up/down to °C/°F.

3. Press OK then scroll up/down to select a desired option. Press OK to confirm.


How do I set the temperature alert on the MOTOROLA NURSERY PIP15-4 MULTI?

1. Press MENU then scroll up/down to TEMPERATURE.

2. Press OK then scroll up/down to TEMP ALERT.

3. Press OK then scroll up/down to select HIGH TEMP/LOW TEMP.

4. Press OK then press up/down to adjust the temperature. Press OK to confirm.

Note: You can only set the lowest and highest temperature for all baby units but not to an individual unit. The temperature range is limited to 14°C/57°F and 39°C/102°F.


How do I set the night light brightness on the MOTOROLA NURSERY PIP15-4 MULTI?

You can toggle the brightness by single-pressing the power/night light button on the baby unit.

Alternatively, using the parent unit:

1. Press MENU then scroll up/down to NIGHT LIGHT.

2. Press OK then scroll up/down to select a baby unit.

3. Press OK and scroll up/down to choose among OFF / LOW / MEDIUM or HIGH. Press OK to confirm.


How do I play lullabies on the MOTOROLA NURSERY PIP15-4 MULTI?

1. Make sure the baby unit(s) are switched on.

2. On the parent unit, press MENU then scroll up/down to LULLABY.

3. Press OK then scroll up/down to select a baby unit, press OK two times to confirm.

To select a specific lullaby: Repeat step 2. Then select a baby unit, press OK then scroll up/down to CHOOSE. Press OK and scroll up/down to the desired option. You can choose among 5 lullabies or PLAY ALL. Press OK to confirm.


How do I adjust the microphone sensitivity (VOX) level on the MOTOROLA NURSERY PIP15-4 MULTI?

1. Press MENU then scroll up/down to VOX.

2. Press OK then scroll up/down to select LEVEL.

3. Press OK then scroll up/down to select a baby unit.

4. Press OK and scroll up/down to choose among 4 levels or OFF. Press OK to confirm.

The VOX setting has OFF, LEVEL 1, LEVEL 2, LEVEL 3 and LEVEL 4. The lowest sensitivity is at Level 1 where only loud crying or screeching sounds from your baby can be heard.


Why does the power/linking LED indicator on the MOTOROLA NURSERY PIP15-4 MULTI parent unit not turn on?

Check whether the parent unit is powered on.

Check whether the batteries are correctly installed and not drained.

Connect the parent unit to the power supply to recharge it.


Why is the power/linking LED indicator on the MOTOROLA NURSERY PIP15-4 MULTI parent unit flashing?

The parent unit and the baby unit may be out of range with each other. Reduce the distance between the units. Make sure the distance between the parent unit and baby unit is less than 450 meters (1500 feet).

The baby unit may be powered off. Press and hold the power button on the baby unit to power it on.


What should I do if I cannot hear the sound or baby cry from the MOTOROLA NURSERY PIP15-4 MULTI parent unit?

The volume level in the parent unit may be set too low. Increase the volume level of the parent unit.

The parent unit and the baby unit may be out of range with each other. Make sure the distance between the parent unit and baby unit is less than 450 meters (1500 feet).


Why is the MOTOROLA NURSERY PIP15-4 MULTI producing a high-pitched noise?

The parent unit and the baby unit are too close with each other. Move the baby and parent units further apart. Make sure the distance between the parent unit and baby unit is less than 450 meters (1500 feet).

The speaker volume of the parent unit may be set too high. Decrease the volume of the parent unit.


What are the technical specifications for the MOTOROLA NURSERY PIP15-4 MULTI?

RF frequency bands 1881.792 MHz to 1897.344 MHz (Europe)
1921.536 MHz to 1928.448 MHz (USA & Canada)
RF transmission power < 0.25 W (EU version)
Line of sight operating range between the baby and parent units 450 meters (1500 feet)
Power adapter for the baby and parent units SHENZHEN BAIJUNDA ELECTRONIC CO. LTD.
Model : UT-681A-5100UY
Input 100-240V AC 50/60Hz, 200mA
Output DC5V 1A

OR

TEN PAO INTERNATIONAL LTD.
Model: S005CAU0500100
Input 100-240V AC 50/60Hz, 200mA
Output DC5V 1A
Battery GPI INTERNATIONAL LTD.
Model :100AAAHC
1.2V 950mAh, AAA
Battery performance For the parent unit:
• 12 hours for a single baby unit
• 9 hours for two baby units
• 6.7 hours for three baby units
• 5.5 hours for four baby units

For the baby unit:
• 14 hours when both night light and lullaby are OFF
• 11.5 hours when the lullaby is ON
• 10 hours when the night light is ON
• 9 hours when both night light and lullaby are ON
NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

CLICK HERE TO DOWNLOAD MOTOROLA NURSERY PIP15-4 MULTI (01) PDF DOCUMENT


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.