FREE ENGLISH MITSUBISHI ELECTRIC MSZ-EX15NLB (01) PDF DOCUMENT.
FREE ENGLISH MITSUBISHI ELECTRIC MSZ-EX15NLB (01) PDF USER GUIDE.
FREE ENGLISH MITSUBISHI ELECTRIC MSZ-EX15NLB (01) PDF USER MANUAL.
FREE ENGLISH MITSUBISHI ELECTRIC MSZ-EX15NLB (01) PDF OWNER GUIDE.
FREE ENGLISH MITSUBISHI ELECTRIC MSZ-EX15NLB (01) PDF OWNER MANUAL.
FREE ENGLISH MITSUBISHI ELECTRIC MSZ-EX15NLB (01) PDF REFERENCE GUIDE.
FREE ENGLISH MITSUBISHI ELECTRIC MSZ-EX15NLB (01) PDF INSTRUCTION GUIDE.
FREE ENGLISH MITSUBISHI ELECTRIC MSZ-EX15NLB (01) PDF REFERENCE MANUAL.
FREE ENGLISH MITSUBISHI ELECTRIC MSZ-EX15NLB (01) PDF INSTRUCTION MANUAL.
FREE ENGLISH MITSUBISHI ELECTRIC MSZ-EX15NLB (01) PDF OPERATING INSTRUCTIONS.
CLICK HERE TO DOWNLOAD MITSUBISHI ELECTRIC MSZ-EX15NLB (01) PDF DOCUMENT
If this is not the document you want for this product, click here to see if we have any other documents for this product.
How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.
What do the symbols displayed on the MITSUBISHI ELECTRIC MSZ-EX15NLB mean?
The symbols on your MITSUBISHI ELECTRIC MSZ-EX15NLB indicate the following:
- A2L WARNING (Risk of fire): This symbol indicates that the unit uses a flammable refrigerant. If refrigerant leaks and comes in contact with fire or a heating part, it will create harmful gas and there is a risk of fire.
- Read OPERATING INSTRUCTIONS: This symbol indicates that you should read the operating instructions carefully before operation.
- Service Personnel Requirement: This symbol indicates that service personnel are required to carefully read the operating instructions and installation manual before operation.
- Further Information: This symbol indicates that further information is available in the operating instructions, installation manual, and similar documents.
What are the required tools for installing the MITSUBISHI ELECTRIC MSZ-EX15NLB?
To install the MITSUBISHI ELECTRIC MSZ-EX15NLB, you will need the following tools:
- Phillips head screwdriver
- Level
- Scale
- Utility knife or scissors
- 3 inches (75 mm) hole saw
- Torque wrench
- Wrench (or spanner)
- 5/32 inch (4 mm) hexagonal wrench
- Flare tool for R410A/R454B
- Gauge manifold for R410A/R454B
- Vacuum pump for R410A/R454B
- Charge hose for R410A/R454B
- Pipe cutter with reamer
What are the key safety warnings I should observe before and during the installation of the MITSUBISHI ELECTRIC MSZ-EX15NLB?
It is critical to observe the following safety warnings for the MITSUBISHI ELECTRIC MSZ-EX15NLB:
WARNING (Could lead to death or serious injury.)
Do not install the unit by yourself (user). Improper installation can cause fire, electric shock, or injury. Always consult a qualified installer.
Follow the instructions in the installation manual precisely.
Use appropriate protective equipment and tools for safety during installation.
Install the unit securely in a location that can bear its weight.
Do not alter the unit, as it may cause fire, electric shock, or injury.
Perform electrical work according to the manual and use an exclusive circuit. Do not connect other appliances to the circuit.
Ground the unit correctly. Do not connect the ground wire to a gas pipe, water pipe, lightning rod, or telephone ground.
Do not damage the wires.
Always shut off the main power when working on the indoor P.C. board or wiring.
Use the specified wires to securely connect the indoor and outdoor units.
Do not install the unit where flammable gas may leak.
Do not use an intermediate connection or extension cord for the power cord. Do not connect many devices to one AC outlet.
Use only the provided or specified parts for installation work.
When plugging in the power supply, ensure the outlet and plug are free of dust, blockages, or loose parts.
Securely attach the electrical cover to the indoor unit and the service panel to the outdoor unit.
Ensure no substance other than the specified refrigerant (R454B) enters the refrigerant circuit.
Do not discharge refrigerant into the atmosphere. Ventilate the room if a leak occurs during installation.
Use appropriate tools and piping materials, as the pressure of R454B is 1.6 times higher than R22.
When pumping down the refrigerant, stop the compressor before disconnecting the refrigerant pipes.
Securely connect the refrigerant pipes before starting the compressor.
Fasten a flare nut with a torque wrench as specified.
When using a gas burner or other flame-producing equipment, completely remove all refrigerant from the air conditioner and ensure the area is well-ventilated.
Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
The appliance shall be stored in a room without continuously operating ignition sources.
Do not pierce or burn.
CAUTION (Could lead to serious injury when operated incorrectly.)
Depending on the installation area, install a Ground Fault Interrupt (GFI) circuit breaker.
Perform the drainage/piping work securely according to the installation manual.
Do not touch the air inlet or the aluminum fins of the outdoor unit.
Do not install the outdoor unit where small animals may live.
Where should I install the indoor unit of the MITSUBISHI ELECTRIC MSZ-EX15NLB?
For the MITSUBISHI ELECTRIC MSZ-EX15NLB indoor unit, select a location with the following characteristics:
The mounting height shall be 5.9 feet (1.8 m) or more from the floor. Up to 7.5 feet (2.3 m) is recommended.
The unit must be installed in a room that exceeds the minimum room area (Amin) determined by the total refrigerant amount (M), as shown in the table below.
SYSTEM WITHOUT BRANCH BOX
| M [kg] | Amin [m²] | Amin [ft²] |
|---|---|---|
| 0.5 | 1.9 | 20 |
| 0.6 | 2.3 | 24 |
| 0.7 | 2.6 | 28 |
| 0.8 | 3.0 | 32 |
| 0.9 | 3.4 | 36 |
| 1.0 | 3.8 | 40 |
| 1.1 | 4.1 | 44 |
| 1.2 | 4.5 | 48 |
| 1.3 | 4.9 | 52 |
| 1.4 | 5.2 | 56 |
| 1.5 | 5.6 | 60 |
| 1.6 | 6.0 | 64 |
| 1.7 | 6.3 | 68 |
| 1.8 | 6.8 | 73 |
| 1.9 | 7.2 | 77 |
| 2.0 | 7.6 | 81 |
| 2.1 | 7.9 | 85 |
| 2.2 | 8.3 | 89 |
| 2.3 | 8.7 | 93 |
| 2.4 | 9.1 | 97 |
| 2.5 | 9.4 | 102 |
| 2.6 | 9.8 | 106 |
| 2.7 | 10.2 | 110 |
| 2.8 | 10.6 | 114 |
Also, ensure the location is:
Where airflow is not blocked.
Where cool (or warm) air spreads over the entire room.
On a rigid wall to reduce the possibility of vibration.
Where it is not exposed to direct sunlight.
Where it can be easily drained.
At a distance of 3 feet (1 m) or more away from a TV and radio.
In a place as far away as possible from fluorescent and incandescent lights.
Where the air filter can be removed and replaced easily.
Where it is away from the other heat or steam source.
Note: Install the indoor unit high on the wall where air can distribute over the entire room.
Avoid the following places for installation:
Where flammable gas could leak.
Where there is an excessive amount of machine oil in the air.
Salty places such as the seaside.
Where sulfide gas is generated (hot spring, sewage, etc.).
Where there is high-frequency or wireless equipment.
Where there is emission of high levels of VOCs.
What are the electrical and refrigerant pipe specifications for the MITSUBISHI ELECTRIC MSZ-EX15NLB?
The specifications for the MITSUBISHI ELECTRIC MSZ-EX15NLB are as follows:
Electrical Specifications
| MODEL | MSZ-EX09NL MSZ-EX12NL MSZ-EX15NL MSZ-EX18NL |
|---|---|
| INDOOR UNIT | |
| Power supply (V, PHASE, Hz) | 208/230, 1, 60 |
| Minches Circuit Ampacity (A) | 1.0 |
| Fan motor (F.L.A.) (A) | 0.67 |
Refrigerant Pipes
| Pipe | Outside diameter inch (mm) | Minimum wall thickness inch (mm) | Insulation thickness inch (mm) | Insulation material |
|---|---|---|---|---|
| For liquid | 1/4 (6.35) | 0.0315 (0.8) | 5/16 (8) | Heat resistant foam plastic 0.045 Specific gravity |
| For gas | 3/8 (9.52) | 0.0315 (0.8) | 5/16 (8) | |
| 1/2 (12.7) | 0.0315 (0.8) | 5/16 (8) |
Wire Connection Notes:
For connecting wires and ground wire, use solid conductor Minches AWG14 or stranded conductor Minches AWG14. Use double insulated copper wire with 600 V insulation. Use copper conductors only and follow local electrical codes.
For the power supply cable and ground wire, use solid or stranded conductor Minches AWG14. Use copper conductors only and follow local electrical codes.
Refrigerant Pipe Notes:
To prevent condensation, insulate both refrigerant pipes. Be sure to use the insulation of the specified thickness. Refrigerant pipe bending radius must be 4 inches (100 mm) or more.
What parts are included with the MITSUBISHI ELECTRIC MSZ-EX15NLB, and what parts do I need to supply?
Before installing your MITSUBISHI ELECTRIC MSZ-EX15NLB, check for the following parts:
Accessories (Indoor unit):
(1) Installation plate – 1
(2) Attachment screws for the installation plate (4 x 25 mm) – 5
(3) Wireless remote controller – 1
(4) Felt tape (For left or left-rear piping) – 1
(5) Remote controller holder – 1
(6) Screws for the remote controller holder (3.5 x 16 mm, Black) – 2
(7) Battery (AAA) for (3) – 2
(8) Air cleaning filter – 2
(9) Soft dry cloth (NAB type only) – 1
Field-Supplied Parts:
(A) Indoor/outdoor unit connecting wire – 1
(B) Extension pipe – 1
(C) Wall hole sleeve – 1
(D) Wall hole cover – 1
(E) Pipe attachment strap – 2 to 5
(F) Screw for (E) (4 x 20 mm) – 2 to 5
(G) Piping tape – 1
(H) Putty – 1
(I) Drain hose (or soft PVC hose, 19/32 inches [15 mm] inner diameter or hard PVC pipe VP16) – 2 to 5
(J) Refrigerant oil – 1
(K) Power supply cord – 1
How do I install the indoor unit of the MITSUBISHI ELECTRIC MSZ-EX15NLB?
Follow these steps to install the indoor unit of the MITSUBISHI ELECTRIC MSZ-EX15NLB:
1. Attaching the Installation Plate:
Find a stud in the wall to attach the installation plate (1) horizontally by tightening the fixing screws (2) firmly. To prevent vibration, install the screws in the holes indicated in the illustration.
2. Drilling:
Determine the hole location on the wall. Drill a Ø 3 inches (75 mm) hole. The outdoor side should be 6/32 to 9/32 inch (5 to 7 mm) lower than the indoor side. Insert the wall hole sleeve (C).
3. Connecting Wires:
Remove the panel assembly.
Place the upper part of the indoor unit on the installation plate.
Remove corner box R and the electrical cover.
Remove the display P.C. board holder, conduit cover, and conduit plate.
Attach the straight joint or elbow joint to the conduit plate with a lock nut.
Process the end of the ground wire and connect it to the ground terminal of the electrical parts box.
Process the end of the indoor/outdoor unit connecting wire (A) and attach it to the terminal block. Ensure no mis-wiring.
Firmly tighten the terminal screws.
Reinstall the conduit plate, conduit cover, and display P.C. board holder.
According to the piping direction, remove the shaded part of corner box L or R. Reinstall the electrical cover, corner box, and front panel.
How do I perform pipe forming and drain piping for the MITSUBISHI ELECTRIC MSZ-EX15NLB?
For pipe forming and drain piping of your MITSUBISHI ELECTRIC MSZ-EX15NLB, follow these general and specific instructions:
Pipe Forming General Instructions:
Place the drain hose below the refrigerant piping.
Ensure the drain hose is not crowded or bent.
When the drain hose passes through a room, wrap it with insulation material (field-supplied).
For Left or Left-Rear Piping:
1. Place the refrigerant piping and the drain hose together, then firmly apply felt tape (4) from the end.
2. Pull out the drain cap at the back right of the indoor unit.
3. Pull out the drain hose at the back left of the indoor unit.
4. Put the drain cap into the section where the drain hose was originally attached at the rear of the unit.
5. Insert the drain hose fully into the drain pan at the back right of the indoor unit.
6. Insert the drain hose into the wall hole sleeve (C) and attach the upper part of the indoor unit to the installation plate (1).
7. Use two pieces of cardboard from the shipping box as spacers to lift the indoor unit.
8. Connect the refrigerant piping with the extension pipe (B).
9. Attach the lower part of the indoor unit into the installation plate (1).
For Rear or Bottom Piping:
Follow similar steps to combine refrigerant piping and the drain hose, insert them into the wall hole sleeve, and securely hook the indoor unit onto the installation plate.
For Right Piping:
Ensure wiring is completed and the conduit cover is installed. Then, combine piping and the drain hose, insert them into the wall hole sleeve, and securely hook the indoor unit onto the installation plate.
Drain Piping:
If the extension drain hose passes through a room, wrap it with insulation.
The drain hose should point downward for easy drainage.
If the provided drain hose is too short, connect it with a field-supplied drain hose.
When connecting to a hard vinyl chloride pipe, insert it securely.
Do not put the drain pipe directly in a drainage ditch where Ammonia or Sulphuric gas may be generated.
How do I make a flare connection for the MITSUBISHI ELECTRIC MSZ-EX15NLB refrigerant pipes?
Follow these steps to create a proper flare connection for the MITSUBISHI ELECTRIC MSZ-EX15NLB:
1. Cut the copper pipe as straight as possible with a pipe cutter.
2. Remove all burrs from the cut section of the pipe, being careful not to get metal shavings into the piping.
3. Remove the flare nuts attached to the indoor and outdoor units and put them on the pipe.
4. Perform the flaring work. Firmly hold the copper pipe in the dimension shown in the table below. Select dimension ‘A’ from the table according to the tool you use.
5. Check the flare. The inside should be shining without any scratches, and the length should be even all around. If defective, cut it off and repeat the procedure.
| Pipe diameter inch (mm) | B inch (mm) | A inches (mm) | Tightening torque | |||
|---|---|---|---|---|---|---|
| Clutch type tool for R410A/ R454B | Clutch type tool for R22 | Wing nut type tool for R22 | ft-lb (kgf.cm) | N•m | ||
| ø 1/4 (6.35) | 21/32 (17) | 0 to 0.02 (0 to 0.5) | 0.04 to 0.06 (1.0 to 1.5) | 0.06 to 0.08 (1.5 to 2.0) | 10 to 13 (140 to 180) | 13.7 to 17.7 |
| ø 3/8 (9.52) | 7/8 (22) | 0.08 to 0.10 (2.0 to 2.5) | 25 to 30 (350 to 420) | 34.3 to 41.2 | ||
| ø 1/2 (12.7) | 1-1/32 (26) | 36 to 42 (500 to 575) | 49.0 to 56.4 | |||
| ø 5/8 (15.88) | 1-5/32 (29) | 54 to 58 (750 to 800) | 73.5 to 78.4 | |||
How do I connect the pipes, perform an airtight test, and insulate the piping for the MITSUBISHI ELECTRIC MSZ-EX15NLB?
Follow these procedures after flaring the pipes for your MITSUBISHI ELECTRIC MSZ-EX15NLB:
1. Pipe Connection:
Fasten the flare nut with a torque wrench as specified in the table. When connecting the indoor unit, first align the center, then tighten the first 3 to 4 turns of the flare nut by hand. Use two wrenches to tighten to the specified torque. For the outdoor unit, connect pipes to the stop valve pipe joint using the same procedure.
2. Refrigerant Pipe Airtight Test:
1. Connect your testing tools. Ensure the stop valves are closed.
2. Add pressure to the refrigerant lines through the service port of the stop valve for GAS. Pressurize to 601 psig (4.15 MPa) slowly.
3. If the specified pressure holds for about one day and does not decrease, the pipes have passed the test.
4. If the pressure decreases, there is a gas leak. Find and repair the source of the leak.
3. Insulation and Taping:
1. Cover the piping joints with a pipe cover.
2. For the outdoor unit side, insulate the piping, including the valves.
3. Apply piping tape (G) starting from the connection on the outdoor unit. Use additional field-supplied insulation if the piping is installed through a ceiling, closet, or where temperature and humidity are high.
How do I perform a test run on the MITSUBISHI ELECTRIC MSZ-EX15NLB after installation?
To perform a test run on your MITSUBISHI ELECTRIC MSZ-EX15NLB:
1. Insert the power supply plug into the power outlet and/or turn on the breaker.
2. Press the Emergency Operation Switch (E.O. SW) once for COOL, and twice for HEAT operation. The test run will be performed for 30 minutes. If the left lamp of the operation indicator blinks every 0.5 seconds, inspect the indoor/outdoor unit connecting wire for mis-wiring. After the test run, emergency mode (set temperature 75°F [24°C]) will start.
3. To stop the operation, press the E.O. SW several times until all LED lamps turn off.
To check the remote (infrared) signal reception, press the OFF/ON button on the remote controller and listen for an audible indicator from the indoor unit. Press the button again to turn the air conditioner off.
What is the auto restart function on the MITSUBISHI ELECTRIC MSZ-EX15NLB?
The MITSUBISHI ELECTRIC MSZ-EX15NLB is equipped with an auto restart function. When the power supply is cut off during operation, such as during a blackout, the function automatically starts operation in the previous setting once the power supply is resumed. If this function is unnecessary, it can be deactivated by a service representative.
How do I remove and reinstall the panel assembly on the MITSUBISHI ELECTRIC MSZ-EX15NLB?
Removal Procedure:
1. Unlock the upper and lower vanes using a thin instrument. Then, remove the horizontal vanes.
2. Remove the 2 screws which fix the panel assembly.
3. Remove the panel assembly. Be sure to remove its bottom right end first.
Installation Procedure:
1. Install the panel assembly by following the removal procedure in reverse.
2. Be sure to press the positions as indicated by the arrows to attach the assembly completely to the unit.
3. Install the horizontal vanes.
How do I remove the indoor unit of the MITSUBISHI ELECTRIC MSZ-EX15NLB from the installation plate?
To remove the bottom of the indoor unit from the installation plate, release both the left and right bottom corner parts of the indoor unit and pull it downward and forward as shown in the figure in the manual.
How do I perform a pump down on the MITSUBISHI ELECTRIC MSZ-EX15NLB?
Refer to the procedures indicated in the installation manual of the outdoor unit for pump down instructions. WARNING: If the refrigeration circuit has a leak, do not execute pump down with the compressor. When pumping down the refrigerant, stop the compressor before disconnecting the refrigerant pipes. The compressor may burst if air etc. get into it.
How do I connect an interface to the MITSUBISHI ELECTRIC MSZ-EX15NLB?
To connect an interface (such as a Wi-Fi adapter) to the MITSUBISHI ELECTRIC MSZ-EX15NLB, follow these steps:
1. Remove the panel and the lower right corner box.
2. Open the covers of the indoor control P.C. board.
3. Join the connecting cable to CN105 on the indoor control P.C. board.
4. Attach the cable clamp provided with the interface to the thick part of the connecting cable with a screw (4×16).
5. Hook the connecting cable into the ribs as shown in the installation manual’s figure.
6. Close the covers of the indoor control P.C. board. Be careful not to catch the thin part of the connecting cable in the cover. Reinstall the panel and the lower right corner box.
Note: Do not cut or extend the connecting cable of the interface. Keep as much distance as possible between the connecting cable and power supply wires. The thin part of the connecting cable should be stored where customers cannot touch it.