KUSSMAUL 091-158 (01) PDF MANUAL

****** Page 1 ****** FILE: 091-158 DATE: 10-12-04 INSTRUCTION MANUAL LOGIC MODULE 3 INPUT AND/OR MODEL# POWER INPUT: +1 2 volts DC LOGIC INPUT: +1 2 volts DC or Ground 3 YEAR WARRANTY KUSSMAUL ELECTRONICS COMPANY, INC. 170 CHERRY AVENUE, WEST SAYVILLE, NY 11796, TEL: 631-567014, 800-346-0857, FAX: 631-567-5826

****** Page 2 ****** INTRODUCTION The 091-158 is a logic module that permits switching on a load when certain other circuits are energized. Complete isolation between circuits is maintained. Two separate logic modes are available and programmed by switches on the circuit board. “AND” Logic: “OR’ Logic: In this mode an output is obtained when there is an input at INPUT 1 and INPUT 2 and INPUT 3. All three inputs must be present in order to obtain an output In this mode an output is obtained when there is an input at INPUT 1 or INPUT 2 or INPUT 3. Any input present will create an output. Input Signal Polarity: An input signal polarity selector switch permits operating with inputs that are either a +12 volt or they may be a connection to ground. Output Signal Polarity: An output signal polarity selector switch permits selecting whether the output should be +12 volts or a connection to ground. CAUTION The output load, either +12 volts or ground Must not exceed 2 amperes

****** Page 3 ****** INSTALLATION Mount the logic module in a dry location away from any sources of heat. Figure 1 illustrates the wiring required. The +12 volts and Ground input are required to supply the output of the logic module. Note that the input signal may be either a +12 volts or Ground. The polarity of the input signal is independent of the polarity of the output. A separate selector switch is provided to select the polarity of the output. NOTE: DO NOT EXCEED AN OUTPUT LOAD OF 2 AMPERES. KI O OR AND/OR SELECTORS Both must be in the same position Gnd Input 1 Input 2 Input 3 o o o o o o O z Gnd 2 o o o o 0 o O O KBALElE-alOKSIhC Gnd z +12 V 1 3 4 5 6 o o Input Signal Polarity Output Signal Polarity OUTPUT FIGURE 1 PROGRAMMING SWITCH LOCATIONS AND INSTALLATION WIRING

****** Page 4 ****** LOGIC PROGRAMMING Figures 2 and 3 illustrate the switch positions for programming the “AND” and the “OR” function. AND CII KUSSMAUL ELECTRONICS INC 091-158-001 GND AND ‘¯IGN D KUSSMAUL ELECTRONICS INC 091-158-001 +12Vå GND cn Programming Switch Positions 3 Input “OR” Logic Positive Signal Input Positive Signal Output Figure 2 Programming Switch Positions 3 Input “AND” Logic Positive Signal Input Positive Signal Output Figure 3

****** Page 5 ****** KI O OR AND/OR SELECTORS Both must be in the same position Gnd Input 1 Input 2 o o 9 o o o o • o z Gnd +12V 2 o o O • O O O o o o Gnd 5 z +12 V 1 3 4 5 Input Signal Polarity Output Signal Polarity 6 OUTPUT NOTE: All programming switch positions are identical to 3 input configuration FIGURE 4 INSTALLATION WIRING FOR USE WITH ONLY 2 INPUT SIGNALS

****** Page 6 ****** TYPICAL- APPLICATIONS 091-158 3 INPUT LOGIC MODULE “OR” Configuration I 23456 Alarm Horn +12v from Ignition Switch Ground High Temperature Low Oil Pressure Compartment Door Open +12 volts Ground +12 volts from ignition switch +12 volts 120 volts A.C. From Shoreline Connection 091-158 3 INPUT LOGIC MODULE (Connected for 2 inputs) “AND” Configuration 123456 Alarm Horn sounds when logic module senses any one of the three inputs Alarm Horn Alarm Horn sounds when logic module senses engine running AND 120 voltsA.C. Figure 5 Typical Applications

****** Page 7 ****** SPECIFICATION AND OUTLINE Power Input: +12 volts D.C., at 2 amperes max. Output: 2 amperes max. Signal Input: Each input, 12 volts at 0.04 amperes 4.50 4.00 O I .27 2.62

****** Page 8 ****** INSTALLATION RECORD e WARRANTY Date Installed Installed By Vehicle Identification Vehicle Owner WARRANTY All products of Kussmaul Electronics Company Inc. are warranted to be free of defects of material or workmanship. Liability is limited to repairing or replacing at our factory, without charge, any material or defects which become apparent in normal use within 3 years from the date the equipment was shipped. Equipment is to be returned, shipping charges prepaid and will be returned, after repair, shipping charges paid. Kussmaul Electronics Company, Inc. shall have no liability for damages of any kind to associated equipment arising from the installation and /or use of the Kussmaul Electronics Company, Inc. products. The purchaser, by the acceptance of the equipment, assumes all liability for any damages which may result from its installation, use or misuse, by the purchaser, his or its employees or others.

FREE ENGLISH PDF

OPERATING INSTRUCTIONS

USER GUIDE – USER MANUAL

OWNER GUIDE – OWNER MANUAL

REFERENCE GUIDE – REFERENCE MANUAL

INSTRUCTION GUIDE – INSTRUCTION MANUAL


KUSSMAUL 091-158 (01) PDF MANUAL
KUSSMAUL 091-158 (01) PDF MANUAL

Leave a comment, question, review or page error below. Account not required.

This site uses Akismet to reduce spam. Learn how your comment data is processed.

Scroll to top