How do I get started with my HONEYWELL VOYAGER XP CURVE 1400G?

Before connecting the HONEYWELL VOYAGER XP CURVE 1400G scanner, you should turn off the computer’s power. Once the scanner is fully connected, you can then power up the computer.


How do I connect the HONEYWELL VOYAGER XP CURVE 1400G scanner to a computer using USB?

To connect the HONEYWELL VOYAGER XP CURVE 1400G via USB, plug the interface cable into the bottom of the scanner and then plug the other end of the cable into a USB port on your computer.


How do I connect the HONEYWELL VOYAGER XP CURVE 1400G scanner using a Keyboard Wedge connection?

To connect the HONEYWELL VOYAGER XP CURVE 1400G as a Keyboard Wedge, first turn off the computer. Unplug the keyboard from the computer. Connect the scanner’s Y-cable into the keyboard port on the computer, and then plug the keyboard into the other end of the Y-cable. If your scanner requires external power, plug the power supply into the cable and then into a wall outlet. Once all connections are secure, you can turn the computer on.


How do I connect the HONEYWELL VOYAGER XP CURVE 1400G scanner to an RS232 Serial Port?

To connect the HONEYWELL VOYAGER XP CURVE 1400G to a serial port, first turn off the computer. Connect the scanner’s cable to the RS232 serial port on your computer. Plug the power supply into the cable and then into a wall outlet. Once the connections are secure, turn the computer on.


What are the proper reading techniques for the HONEYWELL VOYAGER XP CURVE 1400G?

For a good read with your HONEYWELL VOYAGER XP CURVE 1400G, follow these techniques:

• The view finder projects an aiming dot that should be centered over the barcode. It can be positioned in any direction for a successful read.

• Hold the scanner over the barcode, press the button, and center the aiming dot on the barcode.

• The aiming dot appears smaller when the scanner is closer to the code and larger when it is farther away. For smaller barcodes, hold the scanner close. For large barcodes, hold the scanner farther away.

• If a barcode is highly reflective (e.g., laminated), you may need to tilt the scanner at an angle to successfully scan the barcode.


How can I reset my HONEYWELL VOYAGER XP CURVE 1400G to the standard product default settings?

To reset all standard product default settings on your HONEYWELL VOYAGER XP CURVE 1400G, scan the “Standard Product Defaults” barcode found in the Quick Start Guide.


How do I program the keyboard country layout on my HONEYWELL VOYAGER XP CURVE 1400G?

To program the keyboard layout for your country or language, scan the appropriate country code barcode from the Quick Start Guide. By default, national character replacements are used for the following characters: # $ @ [ ] \ | ^ ` { } ~.

Available country codes include:

• USA (Default)

• Belgium

• Denmark

• Finland

• France

• Germany/Austria

• Great Britain

• Italy

• Norway

• Spain

• Switzerland


How do I change the trigger mode on my HONEYWELL VOYAGER XP CURVE 1400G?

You can set your HONEYWELL VOYAGER XP CURVE 1400G to one of two trigger modes by scanning the corresponding barcode:

Manual Trigger – Normal Mode (Default): You need to press the button to read a barcode. Scan the “Manual Trigger – Normal” barcode to enable this mode.

Presentation Mode: The scanner is activated automatically when it “sees” a barcode. Scan the “Presentation Mode” barcode to enable this mode.


How can I add or remove a suffix after each barcode scan on my HONEYWELL VOYAGER XP CURVE 1400G?

You can configure your HONEYWELL VOYAGER XP CURVE 1400G to add a suffix (like a carriage return or tab) after each scan, or to remove suffixes.

• To add a carriage return (CR) after the barcode, scan the Add CR Suffix barcode.

• To add a tab after the barcode, scan the Add Tab Suffix barcode.

• To remove all suffixes, scan the Remove Suffix barcode.


How do I add a Code ID prefix to all symbologies on my HONEYWELL VOYAGER XP CURVE 1400G?

If you want to add a Code ID prefix to all symbologies at once, scan the “Add Code ID Prefix To All Symbologies (Temporary)” barcode from the Quick Start Guide.


How do I enable or disable the Function Code Transmit feature on my HONEYWELL VOYAGER XP CURVE 1400G?

When Function Code Transmit is enabled, and function codes are contained within the scanned data, the scanner transmits the function code to the terminal. When the scanner is in keyboard wedge mode, the scan code is converted to a key code before it is transmitted.

• To turn this feature on, scan the Enable (Default) barcode.

• To turn this feature off, scan the Disable barcode.


How do I use the Data Format Editor on my HONEYWELL VOYAGER XP CURVE 1400G?

The following are abbreviated instructions for entering a data format. For complete instructions, refer to your User Guide.

Step 1. Scan the Enter Data Format symbol.

Step 2. Primary/Alternate Format: scan 0 for Primary Format.

Step 3. Terminal Type: scan 099 for any terminal type.

Step 4. Code I.D.: scan 99 for any barcode type.

Step 5. Length: scan 9999 for any length barcode.

Step 6. Editor commands: use the Programming Chart that follows in the guide.

Step 7. Scan Save to save your entries.


How can I clear all data formats on the HONEYWELL VOYAGER XP CURVE 1400G?

To clear all existing data formats on your HONEYWELL VOYAGER XP CURVE 1400G, scan the “Clear All Data Formats” barcode from the Quick Start Guide.

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

CLICK HERE TO DOWNLOAD HONEYWELL VOYAGER XP CURVE 1400G (01) PDF DOCUMENT


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.