Free English HONEYWELL V8043F (01) PDF document. Download the PDF, use the online viewer, or browse the FAQs for easy troubleshooting.


CLICK HERE TO DOWNLOAD HONEYWELL V8043F (01) PDF DOCUMENT

If this is not the document you want for this product, click here to see if we have any other documents for this product.


How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.


What are the primary features of the HONEYWELL V8043F motorized zone valve?

The HONEYWELL V8043F offers the following features:

– Quiet, dependable operation provided by a motor-operated powerhead and swing-type ball valve.

– A unique rotating ball plug that seats on a different part of its surface on each closing.

– Closes against the flow of water to assure quiet operation.

– Manual opener moves the ball away from the seat, allowing the valve to be installed without disassembly.

– Manual operation is possible on power failure.

– Easy servicing because the entire powerhead assembly can be replaced without removing the valve body from the line.

– Low power requirements allow four valves to be operated from a single 40 VA transformer.

– Includes an integral line voltage end-switch to permit the sequencing of auxiliary equipment.

– Choice of sweat, female NPT, and flare (with union-flare adapters) body styles.

– Compact construction permits fitting under the cover of most baseboards.


What are the technical specifications for the HONEYWELL V8043F?

The HONEYWELL V8043F technical specifications include:

– Static Pressure Rating: Models are available for both 125 psi (VC8043F1000 series) and 300 psi (V8043F3300 series).

– Liquid Temperature Rating: 4 degrees Celsius to 93 degrees Celsius (40 degrees Fahrenheit to 200 degrees Fahrenheit).

– Ambient Temperature Rating: 4 degrees Celsius to 52 degrees Celsius (40 degrees Fahrenheit to 125 degrees Fahrenheit).

– Steam: Standard valves are not recommended for steam service; consult a representative for steam applications.

– Power Requirements: 24 V, 50/60 Hz, 6 W nominal.

– Timing: 15 seconds to open and 4 to 5 seconds to close.

– Auxiliary Switch Ratings: 4.4 Amps running at 120 Vac.

– Thermostat Heater Setting: 0.32 Amps for heat anticipation.


What are the close-off water pressures and capacity ratings for the HONEYWELL V8043F?

The close-off water pressure ratings for the HONEYWELL V8043F are as follows:

– 50 psi for 1.0 Cv

– 20 psi for 3.5 Cv (Standard Rating)

– 8 psi for 8.0 Cv


What are the dimensions for the HONEYWELL V8043F model?

The dimensions for the HONEYWELL V8043F in mm (inches in brackets) are:

Dimension Label Measurement
A 60 (2 3/8)
B 79 (3 1/8)
C 22 (7/8)
D 19 (3/4)
E (Conduit Cover) 98 (3 7/8)
F 98 (3 7/8)
G 87 (3 7/16)
J 19 (3/4)

What are the mounting requirements for the HONEYWELL V8043F?

When installing the HONEYWELL V8043F, follow these mounting instructions:

– The valve may be mounted in any position on a vertical line.

– On a horizontal line, the valve must be mounted so that the powerhead is even with or above the center line of the piping.

– Ensure that enough room is provided above the powerhead to remove the cover for servicing.

– Mount the valve directly in the pipe or tube. It must be installed so that the arrow stamped on the valve body side corresponds to the flow direction.

– For sweat copper fittings, ensure good solder connections are made. Do not use silver solder because of the high melting temperature it requires.

– For normally closed models with sweat fittings, set the opener lever to “MAN. OPEN” before applying heat to the fittings to protect the plug inside the valve. After installation, place the manual opener in the “AUTO” position.


How do the different manual operation modes work on the HONEYWELL V8043F?

The HONEYWELL V8043F actuator has different manual settings:

– AUTO Mode: In this mode, the valve cycles with the thermostat and activates the auxiliary switch when the valve is fully open.

– OPEN Mode: The valve is opened to allow the system to be filled, flushed, or drained. The auxiliary switch is not activated in this mode. The valve returns to AUTO mode when it is energized.

– SWITCH Mode (available on 300 psi models only): The valve is opened and the auxiliary switch is activated to run the pump. The valve returns to AUTO mode when it is energized.


What is the sequence of operation for a Normally Closed HONEYWELL V8043F?

For a Normally Closed HONEYWELL V8043F, the operation is as follows:

Step 1. With the manual opener set to AUTO and the powerhead energized, the valve opens.

Step 2. When the powerhead is de-energized, a spring return mechanism drives the valve to the closed position.

Step 3. The valve can be opened without electrical power by moving the manual opener lever over the stop and pushing slowly and firmly to the “MAN. OPEN” position. The valve will return to the automatic position once it is energized.

Note: The auxiliary switch is not energized when the valve is manually opened.


What wiring connections are used for the HONEYWELL V8043F Tradeline Model?

The HONEYWELL V8043F Tradeline Model features a 5-screw terminal board. This includes a “blind” terminal for transformer and thermostat wiring convenience. It also includes an add-on line voltage enclosure with a conduit opening for end switch wiring.


What are the recommended replacement parts for the HONEYWELL V8043F?

The following replacement parts are specified for the HONEYWELL V8043F:

– Replacement Powerhead (125 psi models): P/N 40003916-013

– Replacement Motor (24 Vac, 50/60 Hz): P/N 272748AB

– Replacement Motor (24 Vac, 50/60 Hz, Plated Motor): P/N 272748ABP

– Replacement End Switch (Old Style, prior to 1978): P/N 272744A

– Replacement End Switch (New Style): P/N 272744B

– Replacement O-Ring: P/N 272756A


CLICK HERE TO DOWNLOAD HONEYWELL V8043F (01) PDF DOCUMENT