FREE ENGLISH HONEYWELL T4700A CHRONOTHERM (01) PDF USER GUIDE

FREE ENGLISH HONEYWELL T4700A CHRONOTHERM (01) PDF USER MANUAL

FREE ENGLISH HONEYWELL T4700A CHRONOTHERM (01) PDF OWNER GUIDE

FREE ENGLISH HONEYWELL T4700A CHRONOTHERM (01) PDF OWNER MANUAL

FREE ENGLISH HONEYWELL T4700A CHRONOTHERM (01) PDF REFERENCE GUIDE

FREE ENGLISH HONEYWELL T4700A CHRONOTHERM (01) PDF INSTRUCTION GUIDE

FREE ENGLISH HONEYWELL T4700A CHRONOTHERM (01) PDF REFERENCE MANUAL

FREE ENGLISH HONEYWELL T4700A CHRONOTHERM (01) PDF INSTRUCTION MANUAL

FREE ENGLISH HONEYWELL T4700A CHRONOTHERM (01) PDF OPERATING INSTRUCTIONS


CLICK HERE TO DOWNLOAD HONEYWELL T4700A CHRONOTHERM (01) PDF MANUAL

If this is not the document you want for this product, click here to see if we have any other documents for this product.

What are the main features of the T4700 Chronotherm thermostat?

Digital temperature sensing and control for energy efficient precision operation.

Flexibility of 5-1-1 day or 7-day programming.

Exceptional comfort control of resistance-rated heating equipment.

Patented CoolSwitch™ design offers a long service life.

Night and day setback of space temperature can save up to 29 percent of the energy used to heat a controlled zone.

Offers up to a 12 percent energy saving during comfort periods compared with conventional bi-metallic electric heating thermostat, according to the Electric Power Research Institute.


What are the different models of the T4700 thermostat?

T4700A: SPST; makes heating circuit on temperature fall.

T4700B: DPST; makes heating circuit on temperature fall. Breaks both sides of 240 volt line with switch in OFF position.


What are the temperature ratings for the T4700?

Operating Range: -20 to +104°F (-30° to +40°C).

Control Range: 45 to 80°F (7 to 27°C) in 1° increments. Factory set at 16°C (61°F).


What are the electrical ratings for the T4700?

Electrical Ratings (Noninductive): 3800W, 16A maximum; 500W, 2A minimum at 240V, 60 Hz.

Wiring: 6 in. (150 mm) stranded copper leadwires, suitable for connection to aluminum wiring if approved special service CO/ALR connectors are used.


What type of sensing element and switching does the T4700 use?

Sensing Element: Electronic thermistor.

Switching: Patented CoolSwitch®.


What happens during the initial power-up of the T4700 thermostat?

When the thermostat is first powered up (or after eight hours of continuous power loss), the display blinks for two seconds and then undergoes a self-test — while 00E displays for about 15 seconds.

This is followed by the display flashing (1:00 PM); the internal checkout is complete and the thermostat is ready to be programmed.


What is the default factory programming for the T4700?

The thermostat defaults to a normal non-programmable thermostat at power-up, indicated with Hold appearing in the display. Pressing the Prog key once enters the programming mode. The thermostat is preset with a factory set schedule for 7 days.

Table 1. Preset Factory Schedule for 7-days.

Event Time Temperature
WAKE 6:00 AM 70°F (21°C)
LEAVE 8:00 AM 61°F (16°C)
RETURN 6:00 PM 70°F (21°C)
SLEEP 10:00 PM 61°F (16°C)

How can I reset the T4700 thermostat to its default settings?

The T4700 can be reset to its default settings (Table 1) by inserting a bent paper clip or similar wire into the small hole on the front of the thermostat (next to the (+) key with the cover open). This resets only the clock; the programmed schedule is retained.

What are the programmable time periods available on the T4700?

The thermostat is flexible and can be programmed to meet your lifestyle. Four time periods are available:

WAKE is the time the thermostat turns on the equipment after an energy saving period. When deciding what time to set for your WAKE period, include extra lead time, depending on the outside temperature and your equipment response time, to give the equipment time to adjust the temperature before you get up.

LEAVE is the time you can set for an energy-saving temperature while you are away at work or school.

RETURN is the time the thermostat turns on the equipment after an energy saving period. When deciding what time to set for your RETURN period, include extra lead time, depending on the outside temperature and your equipment response time to give the equipment time to adjust the temperature before you arrive home.

SLEEP is the time you can set for an energy-saving temperature while you are sleeping.

IMPORTANT: After programming is complete, the device reverts to normal Run mode within five minutes, if no key was pressed, and any new setting is stored in its memory. Always press the keys with your fingertip or similar blunt tool. Sharp instruments like pens and pencil points can damage the keys.


How do I set the current day and time on the T4700?

Follow these steps:
Step Press This Key Description
1 Prog Displays day of the week.
2 + or – Displays changed day of the week.
3 Prog Displays hour of the day.
4 + or – Displays changed hour of the day.
5 Prog Displays minute of the day.
6 + or – Displays changed minute of the day.

How do I set the daily schedule (7-Day programming)?

Follow these steps:
Step Press This Key Description
1 Prog Scrolling through the display shows the first day to program, beginning with Monday.
2 Prog Displays WAKE time.
3 + or – Displays changed WAKE time in ten-minute increments.
4 Prog Displays WAKE setpoint temperature.
5 + or – Displays changed WAKE setpoint temperature.
6 Prog Displays LEAVE time.

NOTE: Continue through LEAVE, RETURN, and SLEEP periods using the same procedure to set the time and temperature for each period.


How do I copy a schedule from one day to another?

Follow these steps:
Step Press This Key Description
1 Prog (until desired day to copy FROM is shown) Selects and displays the day to be copied; for example, Monday.
2 Func Displays COPY FROM day (Monday).
3 + Displays COPY TO day (Tuesday). Use + or – to select the target day.
4 Func Enters the program. (NOTE: Repeat sequence to copy additional days.)

NOTE: To exit the programming mode: 1) press and hold the Prog key for three seconds and the display returns to Run mode, or 2) during the programming session, after five minutes elapsed time with no program change, the display reverts to Run mode. This does not change any of the programmed steps. Simply keep pressing the Prog key until you arrive at the desired mode.


How do I temporarily override the programmed schedule?

To temporarily override the program:
Step Press This Key Description
1 + or – Changes to TEMPorary mode and controls at a new temperature until the next scheduled event (for example, RETURN).

How do I indefinitely override the programmed schedule (Hold Mode)?

To indefinitely override the program (Hold Mode):
Step Press This Key Description
1 Func Changes to HOLD mode and controls at the HOLD temperature indefinitely.
2 + or – Increases or decreases the HOLD temperature.
3 Func Changes from the HOLD mode to the RUN mode.

How do I change additional functions like °C/°F display or 5-1-1/7-day programming?

Use the following steps to program additional functions:
Function Press This Key Description
Begin sequence to convert display or mode. Press and hold both the Prog and Func keys. Initially a random four-digit/letter display occurs (for example, FF FF). Continue to press Prog key until temperature symbol appears.
Convert to °C or °F. Press Prog key a second time. Display shows °C. Use (+) key to change to °F if desired (or °F to C°).
Convert 5-1-1 to 7 day. Press Prog key a third time. Display shows 511d. Press (+) key to change mode to 7-day programming (or back to 5-1-1 programming). Then adjust using the (+) or (-) keys.

NOTE: To exit the programming mode: 1) press and hold the Prog key for three seconds and the display returns to Run mode, or 2) during the programming session, after five minutes elapsed time with no program change, the display reverts to Run mode. This does not change any of the programmed steps. Simply keep pressing the Prog key until you arrive at the desired mode.


How do I check if the thermostat is controlling the heater after initial setup?

1. Press the (+) key until the setpoint displayed exceeds the room temperature to verify that the thermostat is turning on the baseboard heater.

2. When the (°) symbol is flashing, feel for warmth near the heating element that indicates that the unit is generating heat.

3. Press and hold the Prog key until the thermostat returns to the RUN mode.


What should I do if the display shows ‘Oload’?

This indicates the connected load exceeds 3800W. Ensure total baseboard wattage connected does not exceed 3800W. A fire hazard exists if wattage exceeds 3800W. Push Reset key to clear and reset clock.

What should I do if the display shows ’06E’?

This indicates a power failure was detected. Push Reset key to clear and reset clock.

What should I do if there is a missing segment or other abnormal display?

The cause is unknown. Push Reset key to clear and reset clock. If problem persists, call Honeywell Customer Response Center at 1-800-468-1502.

Who can I contact for assistance with the T4700 thermostat?

Please direct any questions about the operation of this thermostat to Honeywell Customer Assistance at 1-800-468-1502, Monday-Friday, 7:00 a.m. – 5:30 p.m. Central time.

How do I return the product if it is defective under warranty?

If the product is defective:

(i) return it, with a bill of sale or other dated proof of purchase, to the retailer from which you purchased it, or

(ii) package it carefully, along with proof of purchase (including date of purchase) and a short description of the malfunction, and mail it, postage prepaid, to the following address:

In the USA:
Honeywell Return Goods
Dock 4 MN10-3860
1885 Douglas Dr N
Golden Valley, MN 55422

In Canada:
Honeywell Limited/Honeywell Limitée
Product Services ON15-FFE
740 Ellesmere Road
Scarborough, Ontario M1P 2V9

This warranty does not cover removal or reinstallation costs.


What is the duration of the warranty for the T4700?

Honeywell warrants this product, excluding battery, to be free from defects in the workmanship or materials, under normal use and service, for a period of one (1) year from the date of purchase by the consumer. The duration of any implied warranties, including the warranties of merchantability and fitness for a particular purpose, is hereby limited to the one year duration of this warranty. Some states do not allow limitations on how long an implied warranty lasts, so this limitation may not apply to you.

Who do I contact for questions concerning the warranty?

If you have any questions concerning this warranty, please write Honeywell Customer Assistance Center, 1985 Douglas Dr, Golden Valley, MN 55422 or call 1-800-468-1502, Monday-Friday, 7:00 a.m. to 5:30 p.m., Central time.

In Canada, write Retail Products ON15-02H, Honeywell Limited/ Honeywell Limitée, 35 Dynamic Drive, Scarborough, Ontario M1V4Z9.


CLICK HERE TO DOWNLOAD HONEYWELL T4700A CHRONOTHERM (01) PDF MANUAL


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.