What surfaces is the HEAT & GLO SL-550TRSI-AUE approved for mounting?
The HEAT & GLO SL-550TRSI-AUE can be mounted on a flat surface with a minimum 6 mm base or on four corner supports, such as concrete masonry blocks, positioned to contact all four perimeter edges on the bottom of the unit.
What are the minimum clearances from the HEAT & GLO SL-550TRSI-AUE to combustible materials?
The minimum clearances are: Glass Front: 914 mm; Floor: 0 mm; Rear: 13 mm; Sides: 13 mm; Top: 86 mm; Ceiling: 787 mm.
What are the minimum clearances from the vent pipe of the HEAT & GLO SL-550TRSI-AUE to combustible materials?
Vertical Sections: 25 mm. Horizontal Sections: Top 75 mm, Bottom 25 mm, Sides 25 mm. At Wall Firestops: Top 75 mm, Bottom 25 mm, Sides 25 mm.
What type of ignition system does the HEAT & GLO SL-550TRSI-AUE use?
The HEAT & GLO SL-550TRSI-AUE uses an electronic ignition system that operates on a 6 volt system.
What are the inlet and manifold pressure requirements for the HEAT & GLO SL-550TRSI-AUE when using natural gas?
For natural gas, the minimum inlet gas supply pressure is 1.13 kPa and the manifold outlet pressure should be set at 0.8 kPa.
What are the inlet and manifold pressure requirements for the HEAT & GLO SL-550TRSI-AUE when using propane?
For propane, the minimum inlet gas supply pressure is 2.75 kPa and the manifold outlet pressure should be set at 2.36 kPa.
Can I mix DVP-series and SLP-series flue components on the HEAT & GLO SL-550TRSI-AUE?
No, you must not mix DVP-series and SLP-series components in any flue system configuration for the HEAT & GLO SL-550TRSI-AUE.
What is the maximum vertical flue length allowed for the HEAT & GLO SL-550TRSI-AUE?
The maximum vertical flue length allowed for the HEAT & GLO SL-550TRSI-AUE is 10.97 meters.
When is a vertical flue restrictor required on the HEAT & GLO SL-550TRSI-AUE?
A vertical flue restrictor must be installed if the HEAT & GLO SL-550TRSI-AUE installation requires a vertical flue exceeding 4.5 meters above the unit with no horizontal flue or elbows.
What is the maximum horizontal run for straight out flueing on the HEAT & GLO SL-550TRSI-AUE?
The maximum horizontal run for straight out flueing on the HEAT & GLO SL-550TRSI-AUE is 610 mm.
What must be done to the HEAT & GLO SL-550TRSI-AUE gas supply line before the first firing?
The gas supply line for the HEAT & GLO SL-550TRSI-AUE should be purged of any trapped air prior to the first firing of the unit.
How do I light the HEAT & GLO SL-550TRSI-AUE?
To light the HEAT & GLO SL-550TRSI-AUE, simultaneously press the star and up arrow buttons on the remote control until a short acoustic signal confirms the start sequence has begun.
How do I turn off the gas to the HEAT & GLO SL-550TRSI-AUE?
To turn off the gas to the HEAT & GLO SL-550TRSI-AUE, push the OFF button on the remote control and remove the batteries from the receiver.
How do I access the controls on the HEAT & GLO SL-550TRSI-AUE?
The controls for the HEAT & GLO SL-550TRSI-AUE are located in the lower compartment behind the lower door. Access is gained by lifting the door up.
What should I do if the HEAT & GLO SL-550TRSI-AUE power is interrupted during operation?
In the event of a power interruption during operation of the HEAT & GLO SL-550TRSI-AUE, either push the OFF button on the remote control or open the access door and manually push the switch to OFF. The switch must be returned to the ON position prior to operation once power is restored.
What is the required maintenance for the HEAT & GLO SL-550TRSI-AUE burner and pilot?
To properly clean the burner and pilot assembly of the HEAT & GLO SL-550TRSI-AUE, turn off the gas, remove the logs, and clean all foreign materials from the top of the burner and pilot. Check to make sure the burner orifice is clean and the pilot orifice is not plugged.
How can I clean the glass door on the HEAT & GLO SL-550TRSI-AUE?
The glass door on the HEAT & GLO SL-550TRSI-AUE should be cleaned using a household glass cleaner. Do not handle or attempt to clean the glass when it is hot.
How do I troubleshoot “No transmission, motor does not turn” on the HEAT & GLO SL-550TRSI-AUE?
The receiver must learn a new code. Press and hold the receiver’s reset button until you hear 2 acoustic signals. After the second longer acoustic signal, release the reset button and within the subsequent 20 seconds, press the down arrow on the remote handset until you hear an additional long acoustic signal confirming the new code is set on your HEAT & GLO SL-550TRSI-AUE.
What causes glass sooting in the HEAT & GLO SL-550TRSI-AUE and how can it be corrected?
Glass sooting in the HEAT & GLO SL-550TRSI-AUE can be caused by flame impingement on logs, improper venturi setting, or debris around the venturi. To correct it, adjust the log set so the flame does not impinge on it, adjust the air shutter at the base of the burner, or inspect the opening at the base of the burner to ensure no material is placed there.
What are the technical specifications for the HEAT & GLO SL-550TRSI-AUE natural gas burner injector?
The burner injector size for the HEAT & GLO SL-550TRSI-AUE when using natural gas is 2.49 mm.
What are the technical specifications for the HEAT & GLO SL-550TRSI-AUE propane burner injector?
The burner injector size for the HEAT & GLO SL-550TRSI-AUE when using propane is 1.45 mm.
What is the maximum gas consumption of the HEAT & GLO SL-550TRSI-AUE for natural gas?
The maximum gas consumption of the HEAT & GLO SL-550TRSI-AUE for natural gas is 28.0 mJ/h.
What is the maximum gas consumption of the HEAT & GLO SL-550TRSI-AUE for propane?
The maximum gas consumption of the HEAT & GLO SL-550TRSI-AUE for propane is 26.0 mJ/h.
How should the HEAT & GLO SL-550TRSI-AUE flame behave after startup?
After the first few minutes of lighting the HEAT & GLO SL-550TRSI-AUE, moisture will disappear and within 15-30 minutes the flames should become yellow. Tips of the flames should never hit the top of the firebox.
What should be checked if the HEAT & GLO SL-550TRSI-AUE pilot flames but there is no main gas flow?
Check if the manual override knob is in the MAN position, ensure the valve is not turned down to pilot flow, or check for low inlet pressure to the valve of the HEAT & GLO SL-550TRSI-AUE.
Can I use solid fuel in the HEAT & GLO SL-550TRSI-AUE?
No, the HEAT & GLO SL-550TRSI-AUE is not for use with solid fuel.
What is the proper way to remove the glass door on the HEAT & GLO SL-550TRSI-AUE?
To remove the glass door of the HEAT & GLO SL-550TRSI-AUE, release the four glass clips around the glass door and carefully lift the glass up and out away from the appliance.
How do I replace the glass panel on the HEAT & GLO SL-550TRSI-AUE?
To replace the glass door on the HEAT & GLO SL-550TRSI-AUE, place the bottom edge on top of the bottom mounting brackets, push the glass against the unit, and latch the two fasteners at the top and the two fasteners at the bottom.
How should log #1 be placed in the HEAT & GLO SL-550TRSI-AUE?
Place log #1 onto the log grate of the HEAT & GLO SL-550TRSI-AUE so that the notches in the bottom of the log fit on the right three grate bars, then push it towards the rear locating tabs.
How should log #2 be placed in the HEAT & GLO SL-550TRSI-AUE?
Place log #2 in the HEAT & GLO SL-550TRSI-AUE so that its left edge sits against the left front grate corner and its right edge rests against the tab on the second grate bar.
How should log #3 be placed in the HEAT & GLO SL-550TRSI-AUE?
Position log #3 in the HEAT & GLO SL-550TRSI-AUE so that its right edge sits on log #1 and its left edge sits on the first grate bar behind log #2.
How should log #4 be placed in the HEAT & GLO SL-550TRSI-AUE?
Position log #4 in the HEAT & GLO SL-550TRSI-AUE between log #1 and the locating tab on the fourth grate bar, pushing its left hand side back to the locating tab on the grate bar.
How should log #5 be placed in the HEAT & GLO SL-550TRSI-AUE?
Put the forked end of log #5 on the base of the HEAT & GLO SL-550TRSI-AUE in front of the grate, towards the center of the second bar grate.
How should log #6 be placed in the HEAT & GLO SL-550TRSI-AUE?
Place log #6 on the base in front of the grate of the HEAT & GLO SL-550TRSI-AUE as shown.
How should log #7 be placed in the HEAT & GLO SL-550TRSI-AUE?
Place log #7 on the groove in log #2 of the HEAT & GLO SL-550TRSI-AUE, with its rear top on log #1 and front top resting on log #5.
How should log #8 be placed in the HEAT & GLO SL-550TRSI-AUE?
Hook log #8 on the right hand corner grate bar of the HEAT & GLO SL-550TRSI-AUE and rest its rear on log #1.
What caution should be taken when handling logs for the HEAT & GLO SL-550TRSI-AUE?
Logs for the HEAT & GLO SL-550TRSI-AUE are fragile; remove them carefully from the packaging. The logs get very hot, so handle them only when cool.
What is the required overlap for flue pipe slip sections on the HEAT & GLO SL-550TRSI-AUE?
Maintain a 1-1/2 inch (38 mm) overlap between the slip section and the pipe section on the HEAT & GLO SL-550TRSI-AUE.
How often must the flue system for the HEAT & GLO SL-550TRSI-AUE be supported?
For horizontal runs, the HEAT & GLO SL-550TRSI-AUE flue system must be supported every 1.5 m. For vertical runs, it must be supported every 2.4 m above the heater flue outlet by wall brackets.
Are firestops required for the HEAT & GLO SL-550TRSI-AUE flue installation?
Yes, for horizontal runs, firestops are required on both sides of a combustible wall through which the HEAT & GLO SL-550TRSI-AUE flue passes. For vertical runs, one firestop is required at the hole in each ceiling through which the flue passes.
What is the requirement for the termination cap on the HEAT & GLO SL-550TRSI-AUE?
The termination cap for the HEAT & GLO SL-550TRSI-AUE must be positioned so that the arrow is pointing up.
How should joints between the finished walls and the HEAT & GLO SL-550TRSI-AUE be sealed?
If joints between the finished walls and the HEAT & GLO SL-550TRSI-AUE surround (top and sides) are sealed, a 149° C minimum sealant material must be used. These joints are not required to be sealed.
What caution should be taken regarding air inlet/outlet grilles on the HEAT & GLO SL-550TRSI-AUE?
When finishing the HEAT & GLO SL-550TRSI-AUE, never obstruct or modify the air inlet/outlet grilles in any manner.
What should I do if the HEAT & GLO SL-550TRSI-AUE pilot sparks, but the pilot will not light?
Verify that the incoming gas line ball valve is open, ensure the ignitor gap is correctly set (0.43 cm from ignitor to pilot hood), and ensure the module is securely grounded to the metal chassis of the HEAT & GLO SL-550TRSI-AUE.
What does a 3 short beep sound indicate on the HEAT & GLO SL-550TRSI-AUE?
This indicates that the batteries in the HEAT & GLO SL-550TRSI-AUE are low. Replace them with quality alkaline batteries.
How should the thermocouple be positioned in the HEAT & GLO SL-550TRSI-AUE pilot flame?
Typically, the top 10 mm of the thermocouple on the HEAT & GLO SL-550TRSI-AUE should be engulfed in the pilot flame.
What is the function of the dress guard on the HEAT & GLO SL-550TRSI-AUE?
The dress guard is fitted to the HEAT & GLO SL-550TRSI-AUE to reduce the risk of fire or injury from burns and no part of it should be permanently removed.
Are there operational cautions regarding the HEAT & GLO SL-550TRSI-AUE and aerosols?
Yes, do not spray aerosols in the vicinity of the HEAT & GLO SL-550TRSI-AUE while it is in operation.
Can I connect 240 VAC to the gas control valve of the HEAT & GLO SL-550TRSI-AUE?
No, do not connect 240 VAC to the gas control valve or control wiring system of the HEAT & GLO SL-550TRSI-AUE.
What should I do if the HEAT & GLO SL-550TRSI-AUE has been under water?
Do not use the HEAT & GLO SL-550TRSI-AUE if any part has been under water. Immediately call a qualified service technician to inspect the unit and replace any part of the control system and any gas control which has been under water.
How do I test for gas leaks on the HEAT & GLO SL-550TRSI-AUE?
After the gas pipe installation for the HEAT & GLO SL-550TRSI-AUE is complete, check all gas connections for leaks with a commercially available, non-corrosive leak check solution. Rinse off all solution following testing. Do not use an open flame.
What is the purpose of the Heat & Glo SL-550TRSI-AUE top heat shield?
The heat shield on the Heat & Glo SL-550TRSI-AUE protects the area from elevated header temperatures; do not remove it as it may cause a fire.
How does the fan in the Heat & Glo SL-550TRSI-AUE operate?
The fan in the Heat & Glo SL-550TRSI-AUE is wired in series with a speed control switch and a temperature sensor switch. Once the speed control is set to an ON position, the temperature sensor will automatically start the fan when it warms up and stop it when it cools down.
What are the required hole dimensions for a ceiling pass-through on the Heat & Glo SL-550TRSI-AUE?
When using DVP pipe with the Heat & Glo SL-550TRSI-AUE, cut a 254 mm x 254 mm hole. When using SLP pipe, cut a 229 mm x 229 mm hole.
What should I do if the Heat & Glo SL-550TRSI-AUE flue cap has been removed?
Once the flue cap on the Heat & Glo SL-550TRSI-AUE has been removed, it cannot be reattached.
Are there specific wiring requirements for the Heat & Glo SL-550TRSI-AUE power supply?
The Heat & Glo SL-550TRSI-AUE requires 240 VAC to be wired to the factory installed junction box. If any original wire as supplied with the appliance must be replaced, it must be replaced with type 105° C rated wire.