What should I do with the packing material for the HANNA INSTRUMENTS HI97713?
Note: Save all packing material until you are sure that the instrument works correctly. Any damaged or defective item must be returned in its original packing material with the supplied accessories.
What safety precautions should be observed when handling reagents for the HANNA INSTRUMENTS HI97713?
The chemicals contained in the reagent kits may be hazardous if improperly handled.
Read the Safety Data Sheets (SDS) before performing tests.
Safety equipment: Wear suitable eye protection and clothing when required, and follow instructions carefully.
If a reagent spill occurs, wipe up immediately and rinse with plenty of water. If reagent contacts skin, rinse the affected area thoroughly with water. Avoid breathing released vapors.
For proper disposal of reagent kits and reacted samples, contact a licensed waste disposal provider.
What are the specifications for the Range and Resolution of the HANNA INSTRUMENTS HI97713 Phosphate LR measurement?
Range: 0.00 to 2.50 mg/L (as PO43-)
Resolution: 0.01 mg/L
What is the Accuracy specification for the HANNA INSTRUMENTS HI97713 Phosphate LR measurement?
Accuracy: ±0.04 mg/L ±4% of reading at 25 °C
What is the light source and bandpass filter specification for the measurement system of the HANNA INSTRUMENTS HI97713?
Light source: Light Emitting Diode
Bandpass filter: 610 nm
Bandpass filter bandwidth: 8 nm
Bandpass filter wavelength accuracy: ±1.0 nm
What is the recommended cuvette type for the HANNA INSTRUMENTS HI97713?
Cuvette type: Round 24.6 mm diameter (22 mm inside)
What are the additional specifications regarding auto logging and auto-off for the HANNA INSTRUMENTS HI97713?
Auto logging: 50 readings
Auto-off: After 15 minutes of inactivity (30 minutes before a READ measurement)
What is the typical battery life for the HANNA INSTRUMENTS HI97713?
Battery life: >800 measurements (without backlight)
What is the operating environment specification for the HANNA INSTRUMENTS HI97713?
Environment: 0 to 50 °C (32 to 122 °F); 0 to 100% RH, non-serviceable
What is the case ingress protection rating for the HANNA INSTRUMENTS HI97713?
Case ingress protection rating: IP67, floating case
How does the internal reference system of the HANNA INSTRUMENTS HI97713 photometer function?
The internal reference system (reference detector) of the HANNA INSTRUMENTS HI97713 photometer compensates for any drifts due to power fluctuations or ambient temperature changes, providing a stable source of light for your blank (zero) measurement and sample measurement.
How do I perform a CAL Check validation using the HANNA INSTRUMENTS HI97713?
To perform a CAL Check:
1. Press CAL Check from measurement mode. The “Not Available“ message or the date, time and status of the last CAL Check will be displayed on the screen.
2. Press Check to start a new CAL Check. Press the functional key at any time to abort the validation process.
3. Use the functional keys to enter the certificate value of the calibration standard found on the CAL Check Standard Certificate. Press Next to continue.
4. Insert the A ZERO CAL Check Cuvette A then press Next to continue. The “Please wait…“ message will be displayed during the measurement.
5. Insert the HI97713B CAL Check Cuvette B then press Next to continue. The “Please wait…“ message will be displayed during the measurement.
6. When the CAL Check is complete the display will show one of the following messages and the value obtained during the measurement:
• “PASSED”: The measured value is within the accuracy specification, no user calibration is required.
• “OUT OF SPECIFICATION“ and Calibrate is available: The measured value is near the expected value. To update the user calibration press Calibrate. Press Accept to confirm or Cancel to return to the previous screen.
• “OUT OF SPECIFICATION“: A user calibration is not allowed, the measured value is outside of the tolerance window. Check the certified value, expiration date and clean the outside of the cuvette. Repeat the CAL Check procedure. If this error continues, contact your nearest HANNA INSTRUMENTS Customer Service Center.
How can I change the displayed chemical formula or unit conversion on the HANNA INSTRUMENTS HI97713?
In order to view the displayed result in the desired chemical formula, enter menu by pressing the functional key and use the functional keys to select Chemical Form. Press Select to change the displayed chemical formula. Use the functional keys to highlight the desired chemical formula and press Select. The selected formula will be saved when the instrument is powered off.
The available options are:
| Chemical Form | Unit |
|---|---|
| PO43- | (mg/L) |
| P | (mg/L) |
| P2O5 | (mg/L) |
Use the functional keys and press Select to change the displayed chemical formula to mg/L of phosphorus (P) and phosphorus pentoxide (P2O5).
How do I view the Good Laboratory Practice (GLP) data on the HANNA INSTRUMENTS HI97713?
Press the functional key to enter the menu. Use the functional keys to select GLP and press Select. Good Laboratory Practice (GLP) shows the date and time of the last user calibration (if available) or factory calibration. To erase the last user calibration and to clear the CAL Check, press Clear and follow the prompts. Press Yes to erase and return to the factory calibration data or No to exit the clear procedure.
How do I view or delete logged data on the HANNA INSTRUMENTS HI97713?
Press the functional key to enter the menu. Use the functional keys to select Log Recall and press Select.
Use the functional keys to highlight a log and press Info to view additional information about the log. From this screen Next and Previous can be used to view other logs.
Press Delete to erase logged data. After pressing Delete a prompt on display is asking for confirmation.
Press No or the functional key to return to the previous screen.
Press Yes to delete selected log.
Press Del All to erase all the logged data. If Del All is pressed, follow the prompt to confirm. Press Yes to delete all logged data, No or the functional key to return to the log recall.
How can I adjust the Backlight setting on the HANNA INSTRUMENTS HI97713?
Option: 0 to 100%
Press Modify to access the backlight intensity. Use the functional keys to increase or decrease the value. Press Accept to confirm or the functional key to return to the Setup menu without saving the new value.
How can I adjust the Contrast setting on the HANNA INSTRUMENTS HI97713?
Option: 0 to 100%
Press Modify to change the display’s contrast. Use the functional keys to increase or decrease the value. Press Accept to confirm the value or the functional key to return to the Setup menu without saving the new value.
How do I modify the Date & Time on the HANNA INSTRUMENTS HI97713?
Press Modify to change the date and time. Press the functional keys to highlight the value to be modified (year, month, day, hour, minute or second). Press Edit to modify the highlighted value. Use the functional keys to change the value.
Press Accept to confirm or the functional key to return to the previous screen.
How can I change the Time Format on the HANNA INSTRUMENTS HI97713?
Option: AM/PM or 24-hour
Press the functional key to select the desired time format.
How can I change the Date Format on the HANNA INSTRUMENTS HI97713?
Press Modify to change the date format. Use the functional keys to select the desired format. Press Accept to confirm or the functional key to return to the Setup menu without saving the new format.
How can I change the Decimal Separator on the HANNA INSTRUMENTS HI97713?
Option: Comma (, ) or Period (.)
Press the functional key to select the desired decimal separator. The decimal separator is used on the measurement screen.
How can I change the Language on the HANNA INSTRUMENTS HI97713?
Press Modify to change the language. Use the functional keys to select the desired language. Press Accept to choose one of the languages installed.
How can I enable or disable the Beeper on the HANNA INSTRUMENTS HI97713?
When enabled, a short beep is heard every time a key is pressed.
A long beep alert sounds when the pressed key is not active or an error is detected.
Press the functional key to enable or disable the beeper.
How can I enable or disable the Tutorial mode on the HANNA INSTRUMENTS HI97713?
When enabled, the user will be guided step-by-step through the measurement procedure.
How can I view the Meter Information on the HANNA INSTRUMENTS HI97713?
Press Select to view the model, serial number, firmware version and selected language. Press the ON/OFF power button key to return to the Setup menu.
How do I restore factory settings on the HANNA INSTRUMENTS HI97713?
Press Select to reset to factory settings. Press Accept to confirm or Cancel to exit without restoring the factory settings.
How do I access the Reagents / Accessories list on the HANNA INSTRUMENTS HI97713?
Press the functional key to enter the menu. Use the functional keys to select Reagents / Accessories and press Select to access a list of reagents and accessories. To exit press the ON/OFF power button key.
How do I access the contextual help mode on the HANNA INSTRUMENTS HI97713?
Press the ? key. The instrument will display additional information related to the current screen. To read all the available information, scroll the text using the functional keys. To exit help mode press the ON/OFF power button or the ? key and the meter will return to the previous screen.
What do the battery icons on the HANNA INSTRUMENTS HI97713 LCD indicate?
100% battery icon: Battery is full.
10% battery icon: Battery is below 10%. Replace the batteries soon.
Low Battery Low icon: Battery is low. Replace the batteries with new ones.
How do I replace the batteries in the HANNA INSTRUMENTS HI97713?
To replace the instrument’s batteries, follow these steps:
Turn the instrument off by pressing and holding the ON/OFF power button key.
Remove the battery cover by turning it counterclockwise.
Remove the old batteries, replace them with three new 1.5V AA batteries.
Replace the battery cover, turn it clockwise to close.
How do I properly use the powder packet reagent for the HANNA INSTRUMENTS HI97713?
1. Use scissors to open the powder packet.
2. Push the edges of the packet to form a spout.
3. Pour out the content of the packet.
What is the procedure for preparing a cuvette for measurement using the HANNA INSTRUMENTS HI97713?
Rinse the cuvette by adding a small quantity of sample. Ensure that the plastic stopper is in place and shake the cuvette several times. Empty the cuvette.
Fill the cuvette with 10 mL of sample (up to the mark). Replace the plastic stopper and the cap.
Insert the cuvette into the holder and ensure that the notch on the cap is positioned securely in the groove.
Whenever the cuvette is placed into the measurement holder, it must be dry outside and free of fingerprints, oil or dirt. Wipe it thoroughly with HI731318 microfiber cleaning cloth or a lint-free wipe prior to insertion.
To avoid reagent leaking and to obtain more accurate measurements, close the cuvette first with the supplied HDPE plastic stopper and then the black cap.
What is the step-by-step measurement procedure for phosphate using the HANNA INSTRUMENTS HI97713?
1. Rinse the cuvette by adding a small quantity of sample. Ensure that the plastic stopper is in place and shake the cuvette several times. Empty the cuvette.
2. Fill the cuvette with 10 mL of sample (up to the mark). Replace the plastic stopper and the cap.
3. Insert the cuvette into the holder and ensure that the notch on the cap is positioned securely in the groove.
4. Press Zero. The display will show “-0.0-” when the meter is zeroed and ready for measurement.
5. Remove the cuvette and add the content of one packet of HI93713-0 Phosphate LR Reagent. Replace the plastic stopper and the cap. Shake gently (for about 2 minutes) until the powder is completely dissolved.
6. Insert the cuvette into the holder and ensure that the notch on the cap is positioned securely in the groove.
7. Press Read and the display will show a 3 minute countdown prior to the measurement. Alternatively, wait 3 minutes then press Read twice. When the timer ends, the meter will perform the reading. The instrument displays concentration in mg/L of phosphate (PO43-).
What interferences can affect the phosphate reading on the HANNA INSTRUMENTS HI97713?
Interference may be caused by:
Iron, Silica above 50 mg/L
Copper, Silicate above 10 mg/L
Arsenate, Highly-buffered samples, Hydrogen sulfide, Turbid samples