FREE ENGLISH GEYA GRT6-ST (01) PDF DOCUMENT.
FREE ENGLISH GEYA GRT6-ST (01) PDF USER GUIDE.
FREE ENGLISH GEYA GRT6-ST (01) PDF USER MANUAL.
FREE ENGLISH GEYA GRT6-ST (01) PDF OWNER GUIDE.
FREE ENGLISH GEYA GRT6-ST (01) PDF OWNER MANUAL.
FREE ENGLISH GEYA GRT6-ST (01) PDF REFERENCE GUIDE.
FREE ENGLISH GEYA GRT6-ST (01) PDF INSTRUCTION GUIDE.
FREE ENGLISH GEYA GRT6-ST (01) PDF REFERENCE MANUAL.
FREE ENGLISH GEYA GRT6-ST (01) PDF INSTRUCTION MANUAL.
FREE ENGLISH GEYA GRT6-ST (01) PDF OPERATING INSTRUCTIONS.
CLICK HERE TO DOWNLOAD GEYA GRT6-ST (01) PDF DOCUMENT
If this is not the document you want for this product, click here to see if we have any other documents for this product.
How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.
What is the GEYA GRT6-ST relay designed for?
The GEYA GRT6-ST relay is designated for the delay ON function of motors in a star/delta configuration.
What are the main function features of the GEYA GRT6-ST?
– Time t1 (star): Features a time scale from 0.1 seconds to 10 minutes, divided into 4 time ranges. Rough time setting is adjusted by a rotary switch.
– Time t2 (delay): Features a time scale from 0.1 seconds to 1 second. The time is set using a potentiometer.
– Relay status is indicated by an LED.
– It is a 1-MODULE device designed for DIN rail mounting.
How can I identify the rated control supply voltage from the model number of the GEYA GRT6-ST?
The rated control supply voltage is indicated by the code at the end of the model number GRT6-ST/.
A230: AC230V
A400: AC400V
S240: AC/DC 24V-240V
What are the technical specifications of the GEYA GRT6-ST?
| Technical parameters | GRT6-ST |
|---|---|
| Function | Delay ON star/delta |
| Supply terminals | A1-A2 |
| Voltage range (Model S240) | AC/DC 24-240V(50-60Hz) |
| Burden (Model S240) | AC 0.7-3VA/DC 0.5-1.7W |
| Voltage range (Models A230, A400) | AC 230V, AC 400V (50-60Hz) |
| Power input (Models A230, A400) | AC max. 6VA/1.3W |
| Supply voltage tolerance | -15%; +10% |
| Supply indication | green LED |
| Time ranges | Range of time delay t1: 0.1 s – 10 min, Switch time t2: 0.1 s – 1 s |
| Time setting | potentiometer |
| Time deviation | 10% – mechanical setting |
| Repeat accuracy | 0.2% – set value stability |
| Temperature coefficient | 0.05%/°C, at=20°C (0.05%°F, at=68°F) |
| Output | 2xSPDT |
| Current rating | 10A/AC1 |
| Switching voltage | 250VAC/24VDC |
| Min. breaking capacity DC | 500mW |
| Output indication | red LED |
| Mechanical life | 1×10⁷ |
| Electrical life (AC1) | 1×10⁵ |
| Reset time | max. 200ms |
| Operating temperature | -20°C to +55°C (-4°F to 131°F) |
| Storage temperature | -35°C to +75°C (-22°F to 158°F) |
| Mounting/DIN rail | Din rail EN/IEC 60715 |
| Protection degree | IP40 for front panel/IP20 terminals |
| Operating position | any |
| Overvoltage category | III. |
| Pollution degree | 2 |
| Max. cable size (mm²) | solid wire max. 1×2.5 or 2×1.5 / with sleeve max. 1×2.5 (AWG 12) |
| Tightening torque | 0.4Nm |
| Dimensions | 90x18x64mm |
| Weight | S240-82g, A230-80g |
| Standards | EN 61812-1, IEC60947-5-1 |
What do the indicators and controls on the front panel of the GEYA GRT6-ST represent?
Based on the panel diagram, the front panel elements are:
Un: This green LED indicates that the supply voltage is on.
R: This red LED indicates the output relay status.
Time range setting (1s, 10s, 1m, 10m): A rotary switch to set the base time range for the star time (t1).
Time setting (10-100%): A potentiometer for fine adjustment of the star time (t1).
Star/delta delay setting (0.1s – 1.0s): A potentiometer to set the delay time (t2) between the star and delta contactors switching.
How does the Delay ON star/delta function work on the GEYA GRT6-ST?
The operational sequence is as follows:
1. When supply voltage (U) is applied, the relay for the star connection (terminals 15-18) closes, and the star time (t1) begins counting.
2. After the set time t1 elapses, the star relay (15-18) opens.
3. A fixed delay time (t2) immediately begins.
4. After the delay time t2 elapses, the relay for the delta connection (terminals 25-28) closes and remains closed as long as the supply voltage is present.
How do I set the delay time on the GEYA GRT6-ST?
To set the star delay time (t1), you use two knobs. The final delay time is the value of Knob 1 multiplied by the value of Knob 2.
Knob 1: This is the delay gear setting. Select a time range (e.g., 10s for 10 seconds, 10m for 10 minutes). “s” stands for second, and “m” stands for minute.
Knob 2: This provides fine adjustment of the delay time, from 10% to 100% of the range selected with Knob 1.
Example 1: Setting for 5 seconds.
Set Knob 1 to 10s. Set Knob 2 to 50%. The delay time will be 10s x 50% = 5s.
Example 2: Setting for 8 minutes.
Set Knob 1 to 10m. Set Knob 2 to 80%. The delay time will be 10m x 80% = 8m.
The transition delay between star and delta (t2) is set using its own dedicated potentiometer, adjustable between 0.1 and 1.0 seconds.
What are the dimensions of the GEYA GRT6-ST?
The dimensions of the GEYA GRT6-ST are 90mm (height) x 18mm (width) x 64mm (depth).
What safety precautions should be followed when installing the GEYA GRT6-ST?
The GEYA GRT6-ST must be installed by qualified electricians. All electrical connections for the product must comply with the appropriate safety standards.
How should the GEYA GRT6-ST be disposed of?
All electrical waste, including the GEYA GRT6-ST, should be disposed of in compliance with current WEEE (Waste Electrical and Electronic Equipment) regulations.