GARDINER TECHNOLOGY GARDTEC 591 (01) PDF SUMMARY:
How do I set the system using an LCD keypad?
With the display showing, enter the User code (followed by YES if Master or Main type code has been used). The display will show and a continuous exit tone will sound. Exit the premises via the authorized exit route (the exit tone will change if any detectors are violated during exit). Once the premises are secure, listen for the exit tone to return to the continuous tone. Wait until the exit tone finishes before leaving.
How do I unset the system using an LCD keypad?
Enter the premises via the authorized entry route (the broken entry tone will sound) and proceed to the keypad. At the keypad, enter a valid code, and the display will show. The system is now unset.
What are the different types of user codes available on the Gardtec 590/591?
Four types of User Codes are available:
- Set Only: Allows only for the setting of the system.
- Main User: Allows setting, part setting, zone removal (if programmed by the engineer), system test, unsetting, and reset after alarm (if programmed by the engineer).
- User: Allows setting, part setting, reset after alarm (if programmed by the engineer), and unsetting.
- Master: Allows setting, unsetting, zone removal (if programmed by the engineer), system test, view log, chime on/off, user codes, set time/date, and reset after alarm (if programmed by the engineer).
How do I remove zones using a Master or Main code?
With the display showing, enter a Master or Main level code. The display will show “Do you want to . . Set?”. Press NO, the display will show “Do you want to . . REMOVE Zones?”. Press YES, the display will show “Enter Zone No. – -then + YES or – NO”. Enter the zone number you wish to remove, followed by YES (pressing NO will ‘un-remove’ a zone). Repeat the previous step until you have removed all required zones. Press 0 to escape. Press YES, the continuous exit tone will sound. Exit the premises via the authorized exit route. Once the premises are secure listen for the exit tone to return to the continuous tone. Wait until the exit tone finishes before leaving. Zone removal is only effective for the one set.
How do I part set the system using Master & Main type codes?
With the display showing, enter a Master or Main type code, the display will show “Do you want to . . Set ?”. Press 1, 2, or 3 (for Part 1, 2, or 3). The exit tone may or may not be heard depending on system settings. Exit the premises or retire to an unprotected part of the system. At the end of the exit time, either the exit sounder will stop or a single beep will be emitted.
How do I view the event log using a Master code?
With the display showing, enter a Master Code. The display will show “Do you want to . . Set ?”. Press NO three times, the display will show “Do you want to . . View the LOG ?”. Press YES, the display will show “Read Log” for 3 seconds, then display the most recent event in the log. While viewing the log, pressing NO will move back to the previous event. Pressing YES will move forward to the next event. Pressing 7 will take you back to the last event of the previous day. Pressing 9 will take you forward to the first event of the next day. When you have finished viewing the Log, press 0 twice, the display will show “Do you want to . . Set ?”.
How do I test the system using a Master or Main code?
With the display showing, enter a Master or Main level code, the display will show “Do you want to . . Set ?”. Press NO, the display will show “Do you want to . . REMOVE Zones ?”. Press NO again, the display will show “Do you want to . . TEST the System ?”. Press YES, the display will show “< All Zones OK > TESTING . . .” for 3 seconds. Pressing 1 will enter zone Status mode. Pressing 6 will silence the internal sounder. Pressing 4 will toggle the Strobe On/Off. Pressing 9 will toggle the Bell On/Off. While in test mode, any zones violated will sound the internal sounder (if it has not been silenced) and show on the display. When you have finished testing the system, press 0 twice.
How do I program user codes using a Master code?
With the display showing, enter a Master Code. Press NO five times, the display will show “Do you want to . . Prog. USER CODES ?”. Press YES, the display will show “Enter User No. – – (1-7) Then YES”. Enter the user number (1 to 7) that you wish to program followed by YES, the display will show “Now Enter Code . . – – – – – – Then YES”. Enter the code you require (codes may be 4, 5, or 6 digits) followed by YES. The display will show “Choose Type . . – 0= xxxxxx 1= xxxxxx”. Enter the required type followed by YES. If you wish to program other User Codes, return to step 4, or press 0 to return to the Unset display.
How do I change the chime status using a Master code?
With the display showing, enter a Master Code. Press NO four times, the display will show “Do you want to . . Change Chime ?”. Press YES, the display will show “Chime is Off ok ?” or “Chime is On ok ?”. Press NO to change the status of the chime, then press YES. Press 0 to escape.
How do I initiate remote access using a Master code?
With the display showing, enter a Master Code. Press NO seven times, the display will show “Do you want to . . Access Remote ?”. Press YES, the display will show “Please WAIT Dialling” until dialing commences, then “Please WAIT Connect” until the connection is established. When the installation company has finished, the display will return to “Do you want to . . Set ?”.
How do I program the time and date using a Master code?
With the display showing, enter a Master Code. Press NO six times, the display will show “Do you want to . . Set DATE / TIME ?”. Press YES, the display will show “Enter Day / Month – – / – – Then YES”. Enter the Day/Month (e.g., 0706 for 7th June) followed by YES. The display will show “Enter Hrs / Mins – – : – – Then YES”. Enter the time using the 24Hr Clock (e.g., 23:30 for 11:30pm) followed by YES. Press 0, the display will show “Do you want to . . Set DATE / TIME ?”.
How do I reset the system after an alarm using an Anti-Code?
Contact the central station or engineer, and quote the source given by the display. The central station or engineer will provide a return Anti-Code. Enter this Anti-Code into the keypad, and the system will be reset.
How do I reset the system after a mains failure?
After a mains failure, the user will have to enter their code twice in order to operate the system.
How do I set the system using an LED keypad?
With the display showing “U N”, enter the User Code (followed by YES if Master or Main type code has been used). The display will show “E =” and the exit tone will sound. Exit the premises via the authorized exit route (the exit tone will change if any detectors are violated during exit). Once the premises are secure, listen for the exit tone to return to the continuous tone. Wait until the exit tone finishes before leaving.
How do I unset the system using an LED keypad?
Enter the premises via the authorized entry route (the broken entry tone will sound). Proceed to the keypad and enter a valid user code. The display will show “U N”. The system is now Unset.
How do I part set the system using Master & Main type codes with an LED keypad?
With the display showing “U N”, enter a Master or Main type code. The display will show “S E” (flashing). Press 1, 2, or 3 (for Part 1, 2, or 3), the display will show “E” and:
- Two bottom bars if Part 1 has been selected.
- The top and bottom bars if Part 2 has been selected.
- The bottom bar only if Part 3 has been selected. The exit tone may or may not be heard depending on system settings. Exit the premises or retire to an unprotected part of the system. At the end of the exit time, either the exit tone will stop or a single beep will be emitted.
How do I remove zones using a Master or Main code with an LED keypad?
With the display showing “U N”, enter a Master or Main level code. The display will show “S E” (flashing), press NO. The Display will show “r E” (flashing), press YES. The display will show “r -”. Enter the zone number you wish to remove followed by YES. If you wish to remove other zones, return to the previous step. To escape, press 0, the display will show “S E” (flashing). Press YES to start setting the system. Zone removal is only effective for the one set.
How do I view the event log using a Master code with an LED keypad?
With the display showing “U N”, enter a Master code. The display will show “S E” (flashing), press NO three times. The display will show “L O” (flashing). Press YES, the display may show, for example, “A L”, which is the most recent event. While viewing the Log, pressing NO will move back to the previous event. Pressing YES will move forwards to the next event. Pressing 7 will take you back to the first event of the previous day. Pressing 9 will take you forwards to the first event of the next day. Pressing 3 will display the Date / Time in the format Day of month (two digits) Month (two digits) Hour (two digits) Seconds (two digits). When you have finished viewing the Log press 0 twice to return to the Unset condition.
How do I test the system using a Master or Main code with an LED keypad?
With the display showing “U N”, enter a Master or Main level code. The display will show “S E” (flashing). Press NO twice, the display will show “t E” (flashing). Press YES, the display will show “t A” press YES if you wish to test all areas (or press NO until the area you wish to test is displayed then press YES). The display will show “t E” (if all zones are clear). While in test mode, pressing 6 will silence the internal sounders. Pressing 4 will toggle the strobe On/Off. Pressing 9 will toggle the Bells On/Off. When you have finished testing the system, press 0 twice to return to the Unset condition.
How do I program the date and time using an LED keypad?
With the display showing “U N”, enter a Master code. The display will show “S E”. Press NO six times, the display will show “D t” (flashing). Press YES, the display will show “D -”, enter the day and month followed by YES (e.g., 0706 for 7th June). The display will show “t -”, enter the time using the 24Hr clock followed by YES (e.g., 2330 for 11:30pm). If you wish to re-program the time, return to the step where the display shows “D t” (flashing) or press 0 to return to the Unset condition.
How do I initiate remote access with an LED keypad?
With the display showing “U N”, enter a master level code, then press NO seven times, the display will flash “A r”. Press YES, the display will show “W X” (Wait), then “D I” (Dialing), then “( N” (Connected). When the installation company has finished, the display will return to “U N”.
How do I change the chime status using a Master code with an LED keypad?
With the display showing “U N”, enter a Master code. The display will show “S E” (flashing). Press NO four times, the display will show “( H”. Press YES, the display will show “O F” or “O N”. Press NO to change the Chime status. When you have finished, press 0 twice to return to the Unset condition.
How do I program user codes using a Master code with an LED keypad?
With the display showing “U C”, enter a Master code. The display will show “S E”. Press NO five times, the display will show “U C” (flashing). Press YES, the display will show “U -”. Enter the User number you wish to program (1 to 7 for 800) followed by YES. The display will show “( O”. Enter the required code (4, 5, or 6 digits) followed by YES. The display will show “t -”, enter the code type, then press YES.
What do the different displays mean during normal use with an LED keypad?
- U N: System Unset.
- E $: The system is full setting.
- $: The system is fully set.
- E %: The system is part 1 setting.
- %: The system is part 1 set.
- E &: The system is part 2 setting.
- &: The system is part 2 set.
- E ^: The system is part 3 setting.
- ^: The system is part 3 set.
- A L: An alarm has occurred press NO to view.
- F B: Fuse blown or battery volts low.
- C B: Control box tamper.
- B B: Bell box tamper.
- P L: Telephone Line fault (or coms fail).
- P C: Power Cut.
- t 4: Tamper keypad 4 (may show 1 to 4).
- E R: Reset is required by a higher level code or an error has occurred whilst programming.
- A C: Reset by Anti-Code is required.
- S E (flashing): Do you want to Set.
- r E: Remove zones.
- t E: Test system.
- ( H: Change Chime.
- U C: Program User codes.
- D t: Program date time.
- L O: Log.
- _ _: Waiting for numeric input.
- W X: Wait, system in use.
- E N: Engineer code reset required.
- E N (flashing): Call Engineer.
How do I reset the system after an alarm with an LED keypad?
If the system is programmed for any code reset, enter a user code (followed by YES if Master or Main code is used), the exit tone will sound, and the display will show for example, “E $”. Enter the code again to abort the setting, and the system will be reset. If the display shows “Er” when you attempt to reset, refer to the programmed reset mode and take the appropriate action.
What are the different reset types and their actions when using an LED keypad?
- Master Code: Use a Master code to set and abort setting.
- Engineer Code: Call the installation company.
- Engineer + Anti-Code: Call the installation company.
- Anti-Code: When you try to set the system, make a note of the four-digit number given on the display, call the installation company or central station for an Anti-Code, and proceed as shown. To reset the system with an Anti-Code, enter the number provided by the central station or installation company into the keypad (this may contain the YES & NO keys), the system is now reset.
How do I reset the system after a mains failure with an LED keypad?
After a mains failure, the user will have to enter their code twice in order to operate the system.
How do I set the system using ACE?
Point the keyfob at the ACE receiver and press the button. When the exit tone sounds, exit the premises in the usual way.
How do I part set the system using ACE?
Point the keyfob at the ACE receiver and press the button. When you hear the exit tone, press the keyfob button again (within 3 seconds) for Part Set 1. Or, press 1, 2, or 3 on the receiver/keypad for the Part Set you require.
How do I unset the system using ACE?
Enter the premises via an authorized entry point. Point the keyfob at the receiver and press the button.
How do I program ACE keyfobs in normal security mode?
Follow the procedure for programming user codes to the point when the user code is entered. Point the keyfob at the ACE unit and press the button on the fob. Repeat this procedure for any other fobs you wish to be programmed using the same user number each time. If more than one ACE receiver is fitted, fobs need to be programmed onto all ACE receivers, yet again the same user number should be used. When programming the fob onto more than one receiver (on the same system), the button on the fob MUST be held down continuously between programming onto the first and subsequent ACE receivers.
How do I program ACE keyfobs in high security mode?
Follow the procedure for programming user codes to the point when the user code is entered. Point the keyfob at the ACE unit and press the button on the fob. Repeat this procedure for any other fobs you wish to be programmed using a different user number each time. If more than one ACE receiver is fitted, fobs need to be programmed onto all ACE receivers, retaining the same user number for each individual fob. When programming the fob onto more than one receiver (on the same system), the button on the fob MUST be held down continuously between programming onto the first and other ACE receivers. Note: When the ACE is used, only Master & Main user levels will allow part setting via the keyfob. Other code levels will only allow part setting in conjunction with the keypad.
CLICK HERE TO DOWNLOAD GARDINER TECHNOLOGY GARDTEC 591 (01) PDF MANUAL