What safety precautions should I take when using the FeverWatchers device?

  • Follow the maintenance advice in the instruction manual.
  • Use the device for personal home use only.
  • Only use the device for the purposes described in the instruction manual.
  • Ensure the device is used in an ambient temperature range of between 50°F and 104°F (10°C and 40°C).
  • Keep the device in a clean, dry area.
  • Do not expose the thermometer to electric shocks.
  • Do not expose the thermometer to extreme temperature conditions of >122°F (>50°C) or <-4°F (<-20°C).
  • Do not use this device in relative humidity higher than 85%.
  • Do not touch the glass of the infrared lens with your fingers.
  • Clean the glass with a cotton swab lightly moistened with 70 proof isopropyl alcohol.
  • Do not expose the thermometer to sunlight or to water.
  • Do not use this device outside.
  • Never drop the device.
  • If a problem occurs with your device, contact your retailer and do not attempt to repair it yourself.

What should I do before using the FeverWatchers RC802i?

Allow the FeverWatchers RC802i to acclimate to any significant changes in the ambient temperature due to a change in environment for 15 to 20 minutes before using it. Allow a one-minute interval between two measurements.


How do I take a temperature using the FeverWatchers RC802i?

Aim at the forehead, over the right temporal region, from a distance of about 2 in (5cm), press the thermometer’s measurement button, and the temperature is instantly displayed. The reliability of the measurement cannot be guaranteed if the temperature is measured over another part of the body (e.g., arm, torso…).


What constraints should I observe before taking a temperature measurement?

  • Push back hair from the forehead.
  • Wipe away any perspiration from the forehead.
  • Avoid any airflow (e.g., from nasal passages, air conditioning…).
  • Allow a 1-minute interval between two measurements.
  • Each time there is a significant change in the ambient temperature due to a change in environment, allow the FeverWatchers RC802i to acclimate to this ambient temperature for at least 15 minutes before using it.

What are the functions of the FeverWatchers RC802i?

  1. Specially designed to take the body temperature of a person regardless of the room temperature.
  2. Quick and reliable results as the device uses the HEIMMANN infrared detection system.
  3. Audible alarm if temperature exceeds set value.
  4. Memorization of the 32 last measurements.
  5. LCD back-lighted digital screen.
  6. Data displayed in Celsius or Fahrenheit.
  7. Automatic power-off (energy saver).
  8. Small, convenient, easy to use.

What additional uses does the FeverWatchers RC802i have?

It can also be used to measure the temperature of a baby bottle or bath, or room temperature by using the Surface Temp function.


How do I use the FeverWatchers RC802i?

  1. Install battery.
  2. For the first use or when inserting new batteries, wait between 10 minutes for the warm-up of the apparatus and when inserting the new batteries.
  3. Aim towards the forehead (see the diagram below for the FeverWatchs positioning), from a distance of 2 in (5 cm), Squeeze the trigger, and the temperature is displayed in 1 second. The temperature can also be taken behind the ear lobe.
  4. Before taking the temperature, make sure to remove hair and perspiration from the forehead. You can also take the temperature from behind the ear lobe.

How do I choose the temperature unit (Fahrenheit or Celsius)?

Press the PROG SETTING button for 3 seconds, the screen displays: F1. Select ‘-’ for degrees Celsius, ‘+’ for degrees Fahrenheit. Confirm by pressing the PROG SETTING button.


How do I set up the alarm?

Press the PROG SETTING button for 3 seconds, the screen displays: F1. Press twice the PROG SETTING button to get to F2. Select ‘+’ to increase the threshold by 0.1°F (0.1°C), ‘-’ to reduce it by 0.1°F (0.1°C). Confirm by pressing the PROG SETTING button.


What is the default alarm threshold value?

The alarm threshold default value is 100.4°F (38°C).


How do I choose between Body or Surface temperature mode?

Press the PROG SETTING button for 3 seconds, the screen displays: F1. Press the PROG SETTING button twice to get to F3. Select 0 by pressing the ‘-’ button to get the BODY mode. Select 1 by pressing the ‘+’ button to get the SURFACE TEMP mode. Confirm by pressing the PROG SETTING button.


What is the measurement range for Body mode?

The measurement range for Body mode: 90°F – 109°F (32°C – 42.9°C).


What is the measurement range for Surface TEMP mode?

Measurement range for Surface TEMP mode: 32°F – 140°F (32°C – 60°C).


When should I use Body mode versus Surface Temp mode?

Select the BODY mode for an internal temperature reading and the SURFACE TEMP mode for an external area reading (bottle, bath, room…).


What mode is the FeverWatchers RC802i automatically set to at the factory?

The FeverWatchers RC802i is automatically set to BODY at the factory.


How do I adjust the total variation of my FeverWatchers RC802i?

Press the PROG SETTING button for 3 seconds, the screen displays: F1. Press the PROG SETTING button three times to get to F4. Select ‘+’ to increase the difference by 0.1°F (0.1°C), ‘-’ to reduce it by 0.1°F (0.1°C). Confirm by pressing the PROG SETTING button. If in doubt, you are advised to leave the total variance at +0°F (+0°C), which is the original factory setting.


When might I need to adjust the total variance setting?

The variance setting exists as a way to offset the difference between the axillary and temporal artery measurements. Normally, this setting does not need to be adjusted unless fine-tuning the device is needed due to skin condition differences. Each time there is a significant change in the ambient temperature due to a change in environment, allow the FeverWatchers RC802i to acclimatize to this ambient temperature for at least 15 minutes before using it.


How do I turn the buzzer on or off?

Press the PROG SETTING button for 3 seconds, the screen displays: F1. Press four times the PROG SETTING button to get to F5. Select ‘+’ to open the buzzer (a sound icon is displayed on the LCD screen), and press ‘-’ to stop it (the icon disappears). Confirm by pressing the PROG SETTING button.


How do I exit the setting mode?

Press the PROG SETTING button until the screen turns off.


How do I display the last temperature measurement?

To display the last temperature measurement, press simultaneously the ‘-’ and ‘+’ button.


How do I navigate the data memory?

To display the last temperature measurement, press simultaneously the ‘-’ and ‘+’ button. You will obtain the last temperature measurement. To switch to the previous measurement, press the ‘+’ button. The number indicated in the interval of two measures corresponds to the number of measurements. Press on the button ‘-’ to go see the next measurement. To exit data memory, press the measure key. The FeverWatchers switches off automatically after 5 seconds.


How do I change the batteries?

When the LCD screen displays ‘Battery’, the battery is low. Open the lid and change the batteries, taking great care of the correct positioning. A mistake with installing the battery could cause damage to the apparatus and compromise the warranty of your FeverWatchers RC802i. Never use rechargeable batteries. Use only alkaline batteries for single usage.


What do I need to know about the FeverWatchers RC802i precision?

  • From 34°C to 35.9°C = ± 0.3°C
  • From 93.2°F to 96.6°F =± 0.3°F
  • From 36°C to 39°C = ± 0.2°C
  • From 96.8°F to 102.2°F = ±0.2°F
  • From 39°C to 42.5°C = ± 0.3°C
  • From 102.2°F to 108.5°F = ± 0.3°F

The FeverWatchers RC802i can take temperature readings below 32°C or above 42.9°C (90°F to 109°F), but precision is not guaranteed outside of this range.


What advice should I keep in mind regarding the FeverWatchers RC802i?

  • The protective glass over the lens is the most important and fragile part of the thermometer; please take great care of it.
  • Clean the glass with cotton fabric, wet with water or 70 proof isopropyl alcohol
  • Do not use other batteries than alkaline batteries, do not recharge non-rechargeable batteries, do not throw in fire.
  • Remove the batteries when the thermometer is not used for an extended period of time.
  • Do not expose the thermometer to sunlight or water.
  • An impact will damage the product.

What do I do if the screen displays a temperature greater than 95°?

The temperature is in Fahrenheit; change the measurement to Celsius by pressing the Program Setting button to get to the F1 function key.


What do I do if the screen displays a body temperature lower than 32°C (89.6°F)?

To take a body temperature, the function key F3 must be on Body mode. If you’re on Surface Temp mode, the 32°C (89.6°F) temperature displayed is showing the external temperature that your body releases.


What does it mean if the screen displays the message HI?

The analysis is above the measurement range selected, either greater than 42.9°C (109°F) in Body Mode or greater than 60°C (140°F) in Surface Temp Mode.


What does it mean if the screen displays the message LO?

The temperature analyzed is under the measuring range selected, either less than 32°C (90°F) in Body Mode or less than 0°C (32°F) in Surface Temp Mode.


What are some reasons for the LO message display and their corresponding advice?

  • Temperature reading hampered by hair, perspiration…: Make sure that there is no obstruction prior to taking a temperature.
  • Temperature hampered by airflow: Make sure there is no airflow, as this could interfere with the infrared system.
  • Temperature readings too close together, the FeverWatchers did not have the chance to reboot itself: Allow a pause of 15 seconds minimum between two readings – a 1-minute pause is advised.
  • The measuring distance is too far: Please respect the measuring distance (between 2 in and 3.14 in or 5 and 8 cm).