What are the general specifications for the FAGOR QR-2?
The general specifications for the FAGOR QR-2 reach-in refrigerator are as follows:
| Model | FAGOR QR-2 |
| Capacity (Cu.Ft.) | 49 |
| Number of Shelves | 6 |
| BTU’S/Hr | 2104 |
| Refrigerant Charge (Ounces) | 11.2 |
| Refrigerant Type | 134a |
| Shipping Weight (lbs) | 475 |
What are the electrical specifications and recommended wire gauges for the FAGOR QR-2?
The electrical requirements for the FAGOR QR-2 are outlined below:
Maximum Amps: 6.9
Horsepower: 1/3 HP
Voltage: 115 / 60 / 1
NEMA Plug: 5-15P
Breaker Size: 15 amp
To prevent a 2% voltage drop in supply circuits, the following wire gauges are recommended based on distance from the breaker to the FAGOR QR-2:
| Distance (Feet) | Wire Gauge (AWG) |
| 40 ft | 14 AWG |
| 60 ft | 12 AWG |
| 80 ft | 12 AWG |
| 100 ft | 10 AWG |
| 120 ft | 10 AWG |
| 140 ft | 10 AWG |
How should the FAGOR QR-2 be uncrated and handled during installation?
When uncrating the FAGOR QR-2, follow these steps:
1. Remove all outer packaging.
2. Cut the four clamps that secure the refrigerator to the skid.
3. Lift the unit off the skid.
4. If the machine was laid down during uncrating or transportation, the cabinet must be left in an upright position for 24 hours before connecting it to a power source.
What are the location requirements for installing the FAGOR QR-2?
To ensure efficient operation of the FAGOR QR-2, the chosen location must meet these criteria:
Indoor Use: The unit is intended for indoor use only.
Floor Strength: The floor must be strong enough to support the total weight of the unit and its contents.
Clearance: Provide at least three inches of space between the sides, back, and top of the unit.
Ambient Temperature: The unit should not be installed in environments where temperatures exceed 100 degrees Fahrenheit. If relative humidity is higher than 60 percent, the door frames may sweat, which is normal.
Airflow: Ensure the unit has access to ample air. Avoid hot corners and locations near stoves or ovens. The area must be open and clean to reduce debris accumulation on the condenser fan and coil.
How should the FAGOR QR-2 be cleaned before it is turned on?
Before turning the FAGOR QR-2 on for the first time, the inside of the cabinet must be cleaned. Use warm water and a mild detergent. Once the unit is cleaned and completely dry, install the accessories and plug the unit into a dedicated outlet. You must wait 24 hours after plugging the unit in before placing any product inside to ensure it is working properly.
How are the castors or optional legs installed on the FAGOR QR-2?
To install castors on the FAGOR QR-2, follow these instructions:
1. Cut the four straps holding the refrigerator to the pallet.
2. Slide the unit out until the castor holes are exposed.
3. Install castors with brakes in the front of the unit.
4. Carefully lift the unit high enough to install the casters and repeat for the remaining wheels.
5. To level the unit, insert the provided shims between the castor and the frame rail. If using more than one shim, turn the slot of the shim at a 90-degree angle to prevent them from slipping out.
6. Turn the bearing race clockwise to tighten and use the provided tool to secure all castors.
7. If using optional legs, thread them by hand into the cabinet bottom frame rail. The ends of the legs are adjustable for leveling.
Note: Never lay the FAGOR QR-2 on its back. If this occurs, leave the cabinet upright for 24 hours before connecting to power.
How do I install the shelving in the FAGOR QR-2?
To install the shelves in the FAGOR QR-2:
1. Hook the shelf rails onto the shelf pilasters.
2. Position all shelf rails at an equal distance from the floor so the shelves are level.
3. Orient the wire shelves so that the cross support bars are facing down.
4. Place the shelves on the shelf clips, ensuring all corners are seated properly.
How do I operate the electronic controller on the FAGOR QR-2?
To start the FAGOR QR-2, turn on the rocker switch located next to the controller. The display will light up and show the internal temperature. The compressor and fan icons will flash for three minutes before the unit begins cooling.
The controller buttons serve the following functions:
UP Arrow: Increases the temperature set point or turns the unit ON/OFF (when held for 3 seconds).
SET Button: Used to change the set point or access programming mode.
DOWN Arrow: Decreases the temperature set point or initiates a manual defrost (when held for 3 seconds).
How can the temperature set point be adjusted on the FAGOR QR-2?
The FAGOR QR-2 comes with a factory default set point of 32 degrees Fahrenheit. To change it:
1. Push the SET button for one second until a flashing number appears, then release it.
2. Press the UP or DOWN arrows to increase or decrease the temperature.
3. Press the SET button again to save the new point.
The maximum allowed set point for the refrigerator is 40 degrees Fahrenheit (5 degrees Celsius), and the minimum is 30 degrees Fahrenheit (-1 degree Celsius).
How do I change the temperature display from Fahrenheit to Celsius on the FAGOR QR-2?
To change the reading of the temperature on your FAGOR QR-2:
1. Press and hold the SET button for five seconds until “PS” appears on the display.
2. Press the SET button once to see the number zero (0).
3. Use the UP arrow to set the value to “22”, then press the SET button. “PS” will appear again.
4. Use the DOWN arrow to find the parameter “EZY” and press SET once.
5. Use the UP or DOWN buttons to set the value based on your needs: Set to “3” for Fahrenheit or “4” for Celsius.
6. Press and hold the SET button for five seconds to confirm. The display will show the temperature in your selected scale.
How do I initiate a manual defrost on the FAGOR QR-2?
To select a manual defrost on the FAGOR QR-2, hold the DOWN arrow button for 5 seconds. A snowflake icon will appear on the display; when this icon is solid, the equipment is in defrost mode. To exit manual defrost early, hold the DOWN arrow button again for 5 seconds. The icon will turn off, and you should wait 2 minutes for the compressor to restart.
What are the maintenance requirements for the FAGOR QR-2 stainless steel surfaces?
Proper care of the FAGOR QR-2 stainless steel includes:
Cleaning Tools: Use only soft cloths or plastic scouring pads. Never use steel pads, wire brushes, or scrapers.
Cleaning Solutions: Use alkaline or non-chloride cleaners. Avoid any cleaners containing chlorides as they damage the protective film of the steel. Never use acid-based solutions.
Daily Routine: Clean the unit every day with soap and water. For extreme stains or grease, use a non-abrasive cleaner and a plastic scrub pad.
Rinsing: If a chloride cleaner is used, rinse the surface repeatedly and dry it thoroughly immediately after.
How should the condenser coil be cleaned on the FAGOR QR-2?
The condenser coil of the FAGOR QR-2 requires regular cleaning every 30 to 60 days. Follow these steps:
1. Disconnect the machine from the power source.
2. Remove the front bottom panel and carefully slide out the condensing unit.
3. For light dust, use a simple brush. For heavier build-up, use a vacuum or compressed air.
4. If heavy grease is present, use a de-greasing agent, then dry the coil with compressed air. Ensure all parts are dry before turning the power back on.
5. Slide the condensing unit back in carefully, ensuring the drain pipe is located over the drain pan, and replace the front panel.
Note: Never use high-pressure water to clean the coil as it can damage electrical components.
How do I maintain and replace gaskets on the FAGOR QR-2?
Gaskets on the FAGOR QR-2 should be cleaned regularly with warm soapy water to prevent mold and maintain elasticity. Avoid chemical products that can cause the gasket to become brittle. Do not use sharp tools or knives for cleaning. To replace a gasket, pull the old one toward you to remove it. To install a new one, press it against the groove of the door until it snaps into place.
What should I check if my FAGOR QR-2 refrigerator is not working?
If the FAGOR QR-2 fails to operate, check the following:
1. Ensure the machine is properly connected to the power source.
2. Verify that the ON/OFF button on the controller is in the ON position.
3. Check that the thermostat is not set to the OFF position.
4. Ensure the unit is not currently in a defrost cycle.
What troubleshooting steps should be taken if the FAGOR QR-2 does not reach the proper temperature?
If the FAGOR QR-2 is running but not reaching the desired temperature, verify the following:
Saving Mode: Ensure the unit is not in saving mode.
Ventilation: Ensure there is a minimum of 2 inches of space from other appliances and the unit is away from heat sources.
Ambient Temp: Confirm the environment is not hotter than 100 degrees Fahrenheit.
Airflow: Product must not be stacked higher than the maximum level mark on the internal wall.
Door Seal: Check that the gasket is in good condition and the door is sealed properly.
Fan Operation: Open the door and press the door switch to verify the fan is moving.
Food Loading: Do not put food inside until the unit has reached the proper temperature. Ensure the unit has been running for 24 hours prior to introducing perishables.
What should I do if there is water inside or under the FAGOR QR-2?
If water is detected in or around the FAGOR QR-2, perform these checks:
Water inside: Check that the internal drain pan is in the correct position and that no food is clogging the drain line.
Water under the unit: Ensure the external drain pipe is positioned correctly over the drain pan and verify that the cabinet is level. Check for any loose or disconnected hose connections.
Environmental factors: Units in humid environments will produce more water; it is the owner’s responsibility to clear the drain pan as needed.