Click here to download ELITECH RCW-600A (01) PDF MANUAL


PDF Content Summary:

****** Page 1 ****** Elitech Elitech Points Record 100 binding O Insert SIM 18:16 Fri TEMP ‘C LowHUMI .10.oC Max TEMP 70.0% 60.5 % Low HUMI 10.0% RCW-600A USER GUIDE Keep Running After Power—off User—friendly Interface

****** Page 2 ****** User Guide Chapterl Product Introduction 1 – 1.1 Overview 1.2 Features and functions 1.3 Technical parameters – Chapter II Instructions for Use 2.1 Device operation procedure 2.1.1 Product introduction 2.1.2 Installation instruction 2.1.3 Operating instructions 2.2 Platform operation procedure 2.2.1 Platform registration 2.2.2 Add devices in the platform 2.2.3 Device parameter setting in platform – 2.2.4 Create project in platform – 2.2.5 Browse project function 2.3 Cell phone operation guide 2.3.1 Cellphone binding 2.3.2 SMS alarm command list Chapter Ill Frequently asked question – 3.1 Cellphone could not be bound 3.2 Cancel phone call alarm —————— 3.3 Big temperature and humidity data error Chapter IV Accessory 4.1 Standard Accessories – 4.2 Optional Accessories ——–21 2 2 2 2 3 3 3 3 5 7 9 9 11 12 -13 13 13 21 21 -21 21 21 21 21 4.3User guide of Elitech cold chain network platform 0

****** Page 3 ****** Chapter I Product Introduction 1.1 Overview RCW-600A cold chain safety monitor is a high-tech product based on networking tech nology. It completely updates the traditional management style of manual record to a new one that uses a monitor to track, monitor and record data in a real—time and dynamic way. It effectively solves the problems of cold storage temperature and humidity abnormity caus ed by human monitoring error, thus avoiding economic loss and hidden danger. The monitor completely complies with the latest GSP standard and can be widely used in industries of pharmaceuticals, foodstuffs, catering, logistics, HACCP system certification, The monitor transmits data to cold chain network platform via 3G network in WCDMA sys tem so that users can achieve real—time monitoring, remote view and management of data online through browser or smart phone terminal. In case of temperature/humidity abnormity, the monitor will immediately alarm by sending short messages or beeping the buzzer. Vario us probes are available. For example, users can select one temperature probe and one hu midity probe based on their actual needs. The monitor has built—in rechargeable lithium ba ttery, so it can provide real—time data uploading and SMS alarm service even in case of cold storage power outage. 1.2 Features and functions • Comply with the latest GSP standard. Real—time monitoring and recording of temperature, humidity and running status of the cold storage. SMS, cellphone APP and on—site alarm in case of over temperature/humidity. Keep working for at least 2 hours after power supply is disconnected. Record cycle could be flexibly adjusted according to the real situation. The record capacity of the monitor is 20000 points, which can be synchronized to the cloud. The cloud has no space limitation so users can conduct statistics and analysis on the record data. 1.3 Technical parameters Power supply: 5V/2.5A(DC); It can connect with power supply of 220V, 50/60HZ by exter nal power adapter. • Temperature measuring range: —400 700 • Temperature accuracy: —200-400 ( ± IC ) , Temperature resolution: 0.1 ; Humidity measuring range: 10-900/0RH; Humidity accuracy: ± 5%RH; Temperature sensor type: N T C; Humidity sensor type: Honeywell; Record cycle: 1 min to 24 hours continuously set; Record capacity: 20,000 points for each way (Max); Applicable environment: temperature —10 C —45 ; Indoor use only, prohibited from exposure to rain and sun. Alarm output: indicator, short message, phone call and buzzer; Communication interface: 3G, SMS; • Standby battery: 3.7 V 1100mAH lithium battery. 0

****** Page 4 ****** Chapter II Instructions for Use 2.1 Device operation procedure 2.1.1 Product introduction Network signal Battery Menu Navigation key 2.1.2 Installation instruction Temperature and humidity sensor Record 100 binding O Ffi 6.7 Ins•vt TEMP 80.aC .10.cc 70.0* 60.5 6.7 60.5 Alarm indicator Power indicator Navigation key Screen lock Power adapter

****** Page 5 ****** GSM antenna Reset (Reserved} Temperature and humidity sensorport Power adapter port Sensor connector should be plugged into the monitor sensor socket.

****** Page 6 ****** 2.1.3 Operating instructions ,lll binding C Points Record 00 Op erations Guide Press the menu key to enter parameter setting interface Press tha up and down key to select the corres ponding parameter. Press theright and left key to adjust the parameters. Press the return key to save parameters. Also can set parameters via SMSi send[bplto bound phone number and send [code] can query all instructions. till binding C Points Record 1 OO Opera Guide Press the menu key to enter parameter setting interface, Press the up and down key to select the corres ponding parameter, Press therigttt and left key to adjust the parameters, Press the return key to save parameters, Also can set parameters via SMS, send[bplto bound phone number and send [code] can query all in structions. Parameter settings binding 0 Enter the password Points Record i 00 On/Off 1 Slide the On/Off key on the back of the monitor to the right, and the monitor is on and displays start—up picture. 2. When the monitor is switched on for the first time or reset to factory defaults, it will display “Operation guide” . Press the Menu button to enter the main interface (Other buttons are disabled at the moment). 3. Slide the On/Off key to the left to switch off the monitor. Main interface GSM signal strength: the signal strength the I monitor has searched currently. 2. Bound cellphones: it displays bound cellphone amount. 3. Alarm indicator: it does not light in normal status; it flashes once a second during over—temperature alarm. I. In the “Main interface” , press to enter the interface of “Enter password” 2. Press and to adjust the digit position; press and to adjust the value. 3. You can set the password on the network platform. The initial password is 123. 4. After inputting the password, press to u enter “Parameter settings” interface.

****** Page 7 ****** binding C Points Record 1 00 “Parameter settings” interface 1 . You can set alarm parameter, data transmission parameter, screen standby, language and factory 1 ,Parameters of the probes 2.1JpIaad record Seting 3.Standhy and Language 4,Factory Reset S About this product reset on this interface. 2. Select “Alarm parameter settings” parameters. Set alarm parameter to set alarm binding O 1 .TEMP upper limit 2. TEMP lower limit 3-TEMP delay 4.HUM upper limit S.HI,JM lower limit 6.HUM delay binding O Data transmit Upload interval Points Record 00 8.0 •c 2.0 •c 70 % 45 % O Points Record open 10min O I . Temperature range: —400—70C; humidity range: 0-1000/0RH; press to select data uploading interval 2. Press within I minute 24 hours. 3. Press to save the parameters and enter ” Parameter settings” interface.

****** Page 8 ****** all binding 0 Points Record 100 Language Standby English 1 min Reset to factory defaults binding 0 Points Record 100 After confirming,the record data and phone mum ber will be cleared , please be cateful! A About the monitor Screen standby and language selection and > I. Select language: Press to switch Chinese/EngIish. 2. Screen standby: three modes are available: 1 min, 5 min and off. The default setting is 1 min. Please press and to select your desired mode. 3. Press S to save the parameters and enter “Parameter settings” interface. Factory defaults reset 1 press and to switch Yes/No. 2. If you select Yes, press and a dialog box will pop up to ask you to confirm or cancel factory defaults reset. When you press u, the monitor resets to factory defaults, i.e. all the record points and bound cellphone numbers will be cleared. 3. Press to save the parameter and enter “Parameter settings” interface. I. Interface: software version, ID and help. 2. Software version: the current software version. 3. ID: the only ID code (a figure with 20 digits) for each monitor. and the A and V to select “Help” 4. Help: press press interface will pop up. 2.2 Platform operation procedure 2.2.1 Platform registration Please visit website: i—elitech.com “Operation guide”

****** Page 9 ****** Step I: Register account Username : Password : Checkcode : Step 2: Submit information Nane : Password ; Passwcyd : Step 3: Log in the platform Username : Password : Checkcode Register Eitetr•e Register 1 .2

****** Page 10 ****** 2.2.2 Add devices in the platform Step 4: Select “device management” , add device ID in the platform (Device ID is label ed in the left side of the product) Add oev«te. Name : B.cw-eav»•. Step 5: After the adding of devices is finished, in the status column, it displays the status of “online activated” , then click “Edit” to set the device parameters. Of.AO R C W-•co.•, 2.2.3 Device parameter setting in platform step 6: Click “Set” to set the time of the device Device Mintainte GUIO: 190-389431c934363841

****** Page 11 ****** Step 7: Set offline record interval. If the device keeps offline for a long time (for example, no credit in SIM card), it is suggested setting a long record interval in order to record data in a long term. Set set ge€:otdinterv8 r Set Set name Set Oe*eG1.O. Step 8: Synchronize cell phone number and the bound number will be displayed on this interface. Step 9: Set the bound cell phone number. You can also bind your cellphone by sending short message to the device. Step 10: Set short message push time tirneaone •agt•og t i”

****** Page 12 ****** Step 11 : Set sensor name, three letters at most. Add Ov•vwé.. Majntance step 12: GLO•. Prot*l PreQ Set sensor parameters 1 . Set upper/lower limit value of sensors 2. Modify the deviation of temperature and humidity. This function is only available for administer. For common users, it is invisible. 3. Alarm delay time; unit: minute. 4. After finishing setting, check “Enable” and then click “Set” sensor setting. GUItr Protea type : t.nt::• 2.2.4 Create project in platform to finish Step 13: Create new project and you can monitor the status of the device and view the coordinate in the map. o

****** Page 13 ****** Step 14: Edit project information (I) Edit the name of project, the type of project, and cold storage volume (2) It displays all added devices in the column of “Select devices” . Select certain device (such as medicine storage shown in the following diagram), and click “Add” button, then it will appear in the column of “selected devices” . Click “Save” button to finish project creating. In the figure below, it has created a medicine project, which uses medicine cold storage device. Selected devote Add 22.5 Browse project function Step 1 5: Device overview—display device list in the format of squares; Type: RCW-OOA RCW.OA iot_adtnin Online 2

****** Page 14 ****** Step 16: Project information—display the basic project information and alarm list mert.L”3: JW•gsu Xuzti•C0 NO, I MO”.nt information; Base info Narr»e: Creator COId Cold kyt_adrnirt Step 17: Data record—display the recorded data and diagram of the device; 2.3 Cell phone operation guide 2.3. I Cellphone binding (I) Connect the power supply of the monitor, and after three minutes the network signal appears in LCD display. Then you can start to bind cell phone one minute later. (2) If you use the monitor for the first time, please send text message “set” by your cellphone to the monitor’ s phone number. Once receiving a confirmation message that it has been successfully bound, you can operate according to SMS prompts. (3) Other common users can send text message “set” by cellphone to the monitor’ s phone number. It will be 0K once a confirmation message is received that it has been successfully bound. (4) The one who first binds his/her cellphone is the administrator and has the authority to modify the command parameters. For details, you can send “code” for reference. You can also refer to the part “2.3.2 SMS alarm command list.” 2.3.2 SMS alarm command list In the following table, rxxxxxJ represents SMS content cellphone users send to the monitor. SMS content does not include the symbol J 13

****** Page 15 ****** SMS alarm administrator command Aim APN settings Bind cellphone Set tempera ture Set humidity Message user sent name r bpJ r hhx x Message device recevied Wait for the display to show GSM network signal, send SMS setting andAPN in accordanqe with SIM operator (If APN is settthere is no need to repeat setting,) Thanks for using, and you are administrator!Send r qsd to query status; send [code] to query all command codes; send rcpJ to cancel binding;send other cellphone number to bind that cell hone. You are administrator now, please do not bind repeatedly. The binding number reaches its upper limit, binding fails. Set success , limit: x xC, limit: x x C. temperature upper temperature lower Set invalid, temperature range –50— 100b, and temperature upper limit should be higher than temperature lower limit. Set success, humidity upper limit: humidity lower limit: Set invalid, humidity range and humidity upper limit should be higher than humidity lower limit. Operating instruction When the cell phone number is repeatedly bound If the alarm value is lower than Ot,then add the symbol ” before the tempera ture; For duel channel tempera turej this set will be valid for both chann els; if the second channel is for humi dity, this set will be only valid for first channel tempera ture. When set tempera ture is overl 000, or lower than —50, or upper limit is lower than lower limit, it will prompt this message. Set humidity alarm value. When set humidity is overl 00% or lower than 1% , or upper limit is lower than lower limit, it will prompt this message.

****** Page 16 ****** Aim Set alarm delay Change push time push closed Change sensor name Change sensor name Query cold storage status Message user sent r daxxJ rptXXYY ZZJ Message device recevied Set success, alarm delay x x min. p2x rqs] x Set invalid, alarm delay range 0-90 min. Set success, timing push XXV YY. ZZ. Set invalid, , hour in 24—hour system, range 0-23. Setting success, timing push is closed. Senorl is renamed tox x x. Set invalid, only could change name of sensor I and sensor 2 with max. 3 characters. Senor 2 is renamed tox x x. Set invalid, only could change name of sensor 1 and sensor 2 with max. 3 characters. ( push ) sensorl : 12.1 C, temperature normal; sensor 2: 40%, humidity normal; power supply normal. ( push ) sensorl : -12.10, temperature normal; sensor 2: 240, temperature normal; power supply normal. Operating instruction x x ” is alarm time delay, default value is 5min, range 0-90, and it could only be set by administrator. If it is set beyond the range 0-90min, the it will prompt this message. If want to close pushing, send [close push J Sensor name has max. 3characters. If over 3 characters, it will automatically intercept first three characters. Sensor name has max. 3characters. If over 3 characters, it will automatically intercept first three characters. It could query current temperature and power supply status of the cold storage.

****** Page 17 ****** Aim phone Bind other cellphone Query all bound numbers Cancel other user’ s cellphone number Change password Message user sent FcpJ Message device recevied Administrator identification is deleted and cellphone is unbound! x x x x x x x x x x x x x x x x successfully bound! x x x x x x x x x x x x xxxxxxx XXXXJ r PW x xxxxxxxxxxx unbound! Password change success, new password is x x x Operating instruction At the time deleting the cellphone, the count of bound cell phones in LCD will also decrease I automatically. If it has bound several cellphones, when administrator’ s cellphone is unbound, the position will be kept and the next new user who binds his cellphone will become administrator. x x x” is the cell phone number, and administrator could bind other user’ s cellphone number. Please input the cellphone number correctly to avoid unnecessary trouble. The one who is bound cellphone will receive a binding message. It could query all bound cellphones. Administrator could unbind other bound cellphones. After finish password change, next time need to input new password to bind cellphone.

****** Page 18 ****** Aim Query all command code Message user sent r code J Message device recevied Send rqpJ toquery all bound Operating instruction numbers; send r dpx x x xxx x x x x x J to cancel other user’ s cellphone number; send rpwx x x to change password; Send rpt XXYY It could query all ZZJ to send push time; send r h x xl SMS command by x x ] to set alarm temperature; send sending [code] fidax x J to set alarm delay; send [cpd to unbound cellphone; send [pl xx x J to rename sensor I to b Wrong command When common users send other commands XXX. Wrong command, send [code J to query all command code Permission denied, please contact with administrator. SMS alarm command for common users It will reply this message only for bound users when they send wrong code. Notice Items Query all command code Message 3 user sent rqsJ Message device recevied When bound by administrator When unbound by administrator When common users send other commands (push) sensorl : 12.1 C, temperature normal; sensor 2: 40%, humidity normal; power supply normal. (push) sensorl : —12.1 Ci temperature normal; sensor 2: 240,temperature normal; power supply normal. Thanks for using! Your cellphone has been bound! Send r code] to query all command codes. Your cellphone has been unbound by administrator. Permission denied, please contact with administrator. 17

****** Page 19 ****** Push message cellphone received Items Timing push Temperature/ humidity alarm Sensor abnormity Cold storage power outage Cold storage power connection Device power off reminding Message received (push) Pl: 12.1 C,temperature normal; P2: 40%, humidity normal; power supply normal. —12.1 c, temperature normal; P2: 240, (push) Pl temperature normal; power supply normal. ( alarm) temperatureupper limit, the device is alarming now! To cancel alarm, please dial the phone of the device. ( alarm) P2:50%, over humidity upper limit, the device is alarming now! To cancel alarm, please dial the phone of the device. ( alarm ) Pl lower limit, the device is alarming now! To cancel alarm, please dial the hone of the device. ( alarm) P2:50%,over humidity lower limit, the device is alarming now! To cancel alarm, please dial the phone of the device. (alarm) Sensor is disconnected. (back to normal) Sensor is connected. (alarm) Power supply abnormal! Please repair it soon! (back to normal) Power is connected! (alarm) The power of cold storage is disconnected, and device will be powered off soon! Please check it asap! 18 Notice

****** Page 20 ****** Chapter Ill Frequently asked question 3.1 (2) (3) 3.2 3.3 (1) (2) Cellphone could not be bound. Check if there is signal in LCD display. Check if there is enough credit in the monitor’ s SIM card. Remove SIM card from the monitor and insert it into a cellphone to check. Check if there has a stable signal around the monitor. Cancel phone call alarm After receiving an alarm message or alarm call, dial the monitor’ s phone, alert can be canceled when you hear the hanging up of the monitor. Big temperature and humidity data error Do not put probe lines and high—voltage power lines together. If extending probe line, please solder the connection points by tin solder to ensure a good connection. Chapter IV Accessory 4.1 Standard Accessories One RCW 600A monitor One temperature/humidity sensor ( with 5m wire) One user manual One power adapter 4.2 Optional Accessories Dual temperature sensor 4.3 ( User guide of Elitech cold chain network platform ) Download address: i—elitech.com

FREE ENGLISH PDF

OPERATING INSTRUCTIONS

USER GUIDE – USER MANUAL

OWNER GUIDE – OWNER MANUAL

REFERENCE GUIDE – REFERENCE MANUAL

INSTRUCTION GUIDE – INSTRUCTION MANUAL



ELITECH RCW-600A (01) PDF MANUAL

Leave a comment, question, review or page error below. Account not required.

This site uses Akismet to reduce spam. Learn how your comment data is processed.