What are the recommended wire gauges for ELECTRO-VOICE EVID-S5.2XB installations to maintain a 0.5 dB loss?
For a 100 Watt system, use 18 AWG for up to 230 ft, 16 AWG for 360 ft, 14 AWG for 560 ft, and 12 AWG for 910 ft. For a 40 Watt system, use 18 AWG for 560 ft, 16 AWG for 900 ft, 14 AWG for 1400 ft, and 12 AWG for 2300 ft. For a 10 Watt system, use 18 AWG for 2300 ft, 16 AWG for 3600 ft, 14 AWG for 5600 ft, and 12 AWG for 9100 ft.
How do I install the U-Bracket for the ELECTRO-VOICE EVID-S5.2XB?
First, draw a level line on the mounting surface. Second, align the screw holes of the U-Bracket on that line. Third, install two mounting screws to securely attach the U-Bracket to the wall.
What is the procedure for mounting the ELECTRO-VOICE EVID-S5.2XB to the U-Bracket?
Once the U-Bracket is installed, insert the two provided screws into the U-Bracket mounting points. Loosely tighten these screws using the provided Allen wrench. Aim the speaker in the desired direction, then fully tighten the two screws to secure the speaker to the U-Bracket.
How do I wire the ELECTRO-VOICE EVID-S5.2XB with two cables?
Loosen both gland nuts and push the wires through them. Connect the wires to the Euroblock connector. Plug the connector into the speaker. Insert the four screws into the weather cover and loosely tighten them. Tighten the four screws to secure the cover, adjust the wire length, and finally tighten the gland nuts.
What are the steps to wire the ELECTRO-VOICE EVID-S5.2XB with one cable?
Loosen both gland nuts. Push the wire through one of the gland nuts and insert the provided plug into the other. Tighten the gland nut with the plug to seal it. Connect the wire to the Euroblock connector, plug it into the speaker, secure the weather cover with four screws, adjust wire length, and tighten the remaining gland nut.
How do I change the transformer settings on the ELECTRO-VOICE EVID-S5.2XB?
Use the rotary switch on the input panel to select the desired power tap. If you wish to set the speaker to 8 ohm mode, you must also remove the safety screw from the panel.
What is the procedure for replacing the logo on the ELECTRO-VOICE EVID-S5.2XB?
Remove the existing logo. Clean the surface thoroughly with alcohol. Align the new logo with the recess on the grille. Remove the paper backing from the logo and insert it into the recess. Press firmly to ensure it is applied correctly.
What should I check if there is no sound from the ELECTRO-VOICE EVID-S5.2XB?
Check that all electronics are powered on, the signal routing is correct, the source is active, and the volume is turned up. Connect a known working test speaker to the amplifier outputs; if there is still no sound, the issue is with the electronics. If there is sound, the problem lies in the wiring.
How do I troubleshoot poor low frequency response on the ELECTRO-VOICE EVID-S5.2XB?
Poor low frequency response often indicates that the speakers are wired out of polarity. Verify that the amplifier positive terminal is connected to the red speaker terminal and the negative terminal is connected to the black speaker terminal. If using a subwoofer, ensure the subwoofer input panel is correctly wired.
What causes constant noise like buzzing or humming in the ELECTRO-VOICE EVID-S5.2XB?
Constant noise usually points to a defective amplifier or other electronic device in the signal chain. Alternatively, it may be caused by poor system grounding or a ground loop, which should be checked and corrected.
What are the transformer tap settings for the ELECTRO-VOICE EVID-S5.2XB?
The 70V settings are 60 W, 30 W, 15 W, 8 W, and 8 Ω. The 100V settings are 60 W, 30 W, 16 W, and 8 Ω.
What is the recommended high-pass setting for the ELECTRO-VOICE EVID-S5.2XB?
The recommended high-pass setting is 60 Hz at 24 dB/octave.
What is the ingress protection rating of the ELECTRO-VOICE EVID-S5.2XB?
The ELECTRO-VOICE EVID-S5.2XB is IP65 rated per IEC-60529.
What is the nominal impedance of the ELECTRO-VOICE EVID-S5.2XB?
The nominal impedance of the ELECTRO-VOICE EVID-S5.2XB is 8 Ω.
What is the minimum impedance of the ELECTRO-VOICE EVID-S5.2XB?
The minimum impedance of the ELECTRO-VOICE EVID-S5.2XB is 6.5 Ω.
What are the dimensions of the ELECTRO-VOICE EVID-S5.2XB?
The dimensions are 255 mm x 180 mm x 148 mm (10.0 in x 7.1 in x 5.8 in), excluding the U-Bracket.
What is the net weight of the ELECTRO-VOICE EVID-S5.2XB?
The net weight of the ELECTRO-VOICE EVID-S5.2XB is 3.2 kg (7.1 lb), excluding the U-Bracket.
What is the maximum wire size allowed for the ELECTRO-VOICE EVID-S5.2XB connectors?
The connectors support a maximum wire size of 12 AWG (2.05 mm diameter).
Does the ELECTRO-VOICE EVID-S5.2XB include a safety cable loop?
Yes, the ELECTRO-VOICE EVID-S5.2XB features a safety cable loop for added security.
What are the power handling specifications for the ELECTRO-VOICE EVID-S5.2XB?
The power handling is 75 W continuous pink noise (100 hours) with a 300 W peak.
Can I use a threaded rod to install the ELECTRO-VOICE EVID-S5.2XB U-Bracket?
Yes, the ELECTRO-VOICE EVID-S5.2XB U-Bracket can be installed to a threaded rod.
Can I mount the ELECTRO-VOICE EVID-S5.2XB using a pole mount?
Yes, the ELECTRO-VOICE EVID-S5.2XB U-Bracket can be installed to a pole mount using steel band clamps.
How do I install the ELECTRO-VOICE EVID-S5.2XB to a junction box?
The ELECTRO-VOICE EVID-S5.2XB U-Bracket can be installed to a junction box using a 0.25 inch rubber grommet for wiring.
What are the coverage angles of the ELECTRO-VOICE EVID-S5.2XB?
The coverage angle of the ELECTRO-VOICE EVID-S5.2XB is 90 degrees horizontal and 90 degrees vertical.
Is the ELECTRO-VOICE EVID-S5.2XB paintable?
No, the ELECTRO-VOICE EVID-S5.2XB cannot be painted when used in UL1480, ULC-S541, or EN54-24 fire installations.
Are there special requirements for fire installations of the ELECTRO-VOICE EVID-S5.2XB?
Yes, for UL1480, ULC-S541, and EN54-24 fire installations, the weather cover must be used.
Can the ELECTRO-VOICE EVID-S5.2XB be connected to DC supervised systems?
No, for UL1480, ULC-S541, and EN54-24 fire installations, the ELECTRO-VOICE EVID-S5.2XB is not intended for connection to DC supervised systems.
What is the sensitivity of the ELECTRO-VOICE EVID-S5.2XB?
The sensitivity of the ELECTRO-VOICE EVID-S5.2XB is 89 dB (half-space, on wall, averaged 100 Hz to 10 kHz, 1 W).
How do I dispose of the ELECTRO-VOICE EVID-S5.2XB at the end of its life?
This product must be disposed of separately from household waste according to local laws and regulations to allow for reuse and recycling.
Are there redundant safety requirements for suspending the ELECTRO-VOICE EVID-S5.2XB?
Yes, it is suggested to install an extra suspension point back to the building structural supports with as little slack as possible, preferably less than 1 inch.
What is the low frequency performance of the ELECTRO-VOICE EVID-S5.2XB?
The ELECTRO-VOICE EVID-S5.2XB features a 5.25 inch woofer that provides extended LF performance down to 55 Hz.
What is the maximum SPL of the ELECTRO-VOICE EVID-S5.2XB?
The calculated maximum SPL of the ELECTRO-VOICE EVID-S5.2XB is 108 dB (114 dB Peak).
What is included in the packing list for the ELECTRO-VOICE EVID-S5.2XB?
The packing list includes 2 speakers, 1 Allen wrench, 4 safety screws for the U-Brackets, 2 U-brackets, 2 weather covers, 8 weather cover screws, 2 spare grille logos, and 1 installation manual.
How are the U-Brackets for the ELECTRO-VOICE EVID-S5.2XB mounted?
The U-Brackets can be mounted using a standard 2-inch or 4-inch U-Bolt.
What are the environmental ratings of the ELECTRO-VOICE EVID-S5.2XB?
The ELECTRO-VOICE EVID-S5.2XB is IP65 rated, designed to withstand the toughest weather conditions.
What is the rated frequency range for UL1480/ULC-S541 installations of the ELECTRO-VOICE EVID-S5.2XB?
The rated frequency range for UL1480/ULC-S541 installations is 400 Hz to 4 kHz.
What is the rated frequency range for UL1480A/CSA C22.2 NO. 205 installations of the ELECTRO-VOICE EVID-S5.2XB?
The rated frequency range for UL1480A/CSA C22.2 NO. 205 installations is 55 Hz to 20 kHz.
What is the cabinet construction of the ELECTRO-VOICE EVID-S5.2XB?
The enclosure and baffle of the ELECTRO-VOICE EVID-S5.2XB are made of UL 94-5VB fire rated ABS plastic.
Are there specific installation standards I should follow when wiring the ELECTRO-VOICE EVID-S5.2XB?
Yes, in Canada you must follow CSA C22.1 and ULC-S524. In the United States, follow the National Electrical Code NFPA 70 and NFPA 72. In the EU, follow national electrical codes.
What type of connector is used for the ELECTRO-VOICE EVID-S5.2XB?
The ELECTRO-VOICE EVID-S5.2XB uses a removable locking 4-pin connector (Euroblock).
Can I use rigid conduit for wiring the ELECTRO-VOICE EVID-S5.2XB?
No, connections for the ELECTRO-VOICE EVID-S5.2XB shall not be made with rigid conduit but with flexible conduit or wiring only.
What is the acoustic design of the ELECTRO-VOICE EVID-S5.2XB?
The ELECTRO-VOICE EVID-S5.2XB utilizes a two-way design, internally damped, with a passive crossover.
How should I clean the surface before replacing the ELECTRO-VOICE EVID-S5.2XB logo?
Clean the surface with alcohol before applying the new logo.
What should I do if a speaker is not working after checking the wiring on the ELECTRO-VOICE EVID-S5.2XB?
If the connection is clean and tight but the problem persists, the issue might be in the amplifier or the wiring. Connect a test speaker in parallel to test each connection point along the line.
Are there specific tools provided with the ELECTRO-VOICE EVID-S5.2XB?
Yes, a 5-mm Allen wrench is provided with the ELECTRO-VOICE EVID-S5.2XB.
What is the shipping weight of the ELECTRO-VOICE EVID-S5.2XB?
The shipping weight of the ELECTRO-VOICE EVID-S5.2XB package is 9.5 kg (21.0 lb).
What is the grille material of the ELECTRO-VOICE EVID-S5.2XB?
The grille for the ELECTRO-VOICE EVID-S5.2XB is made of power-coated Aluminum.
Does the ELECTRO-VOICE EVID-S5.2XB have a pass-through feature?
Yes, the ELECTRO-VOICE EVID-S5.2XB has a 60 W transformer with an 8 Ω pass-through.
Is the ELECTRO-VOICE EVID-S5.2XB suited for outdoor use?
Yes, the ELECTRO-VOICE EVID-S5.2XB is engineered for the toughest weather conditions and is IP65 rated, making it suitable for both indoor and outdoor applications.
What should I do if the sound is very weak during ELECTRO-VOICE EVID-S5.2XB testing?
If the sound is very weak, the line may have a short circuit, possibly caused by a scrape, pinch, or staple puncture.
How can I confirm if a wire is open in the ELECTRO-VOICE EVID-S5.2XB installation?
If the test speaker produces sound at a normal level when connected in parallel, but the main line is silent or weak, the wire is likely open, indicating a cut wire or missed connection.
What is the high frequency transducer size of the ELECTRO-VOICE EVID-S5.2XB?
The high frequency transducer size of the ELECTRO-VOICE EVID-S5.2XB is 0.75 in (20 mm).
What is the low frequency transducer size of the ELECTRO-VOICE EVID-S5.2XB?
The low frequency transducer size of the ELECTRO-VOICE EVID-S5.2XB is 5.25 in (133 mm).
Are there any specific color options for the ELECTRO-VOICE EVID-S5.2XB?
Yes, the ELECTRO-VOICE EVID-S5.2XB is available in black (RAL 9004) or white (RAL 9003).
What is the frequency response (-3 dB) of the ELECTRO-VOICE EVID-S5.2XB?
The frequency response (-3 dB) of the ELECTRO-VOICE EVID-S5.2XB is 90 Hz to 20 kHz.
What is the sensitivity (SPL 1 W / 1 m) of the ELECTRO-VOICE EVID-S5.2XB in UL1480 installations?
The sensitivity (SPL 1 W / 1 m) of the ELECTRO-VOICE EVID-S5.2XB for UL1480/ULC-S541 installations is 87 dB.
What is the power handling of the ELECTRO-VOICE EVID-S5.2XB at 8 ohms in UL1480 installations?
In UL1480/ULC-S541 installations, the power handling of the ELECTRO-VOICE EVID-S5.2XB at 8 ohms is 30 W.