****** Page 1 ****** USER MANUAL PREMIUM LOW ENERGY COMPRESSOR DEHUMIDIFIER WITH DIGITAL HUMIDISTAT AND SMART APP CONTROL CD12PRO-LE – 12 Litres per day CD20PRO-LE – 20 Litres per day Thank you for choosing electriQ. Please read this user manual before using this innovative dehumidifier and keep it safe for future reference Visit our page electriQ.co.uk for our entire range of Intelligent Electricals

****** Page 2 ****** CONTENTS SAFETY INSTRUCTIONS INSTALLATION CONTROL PANEL QUICK REFERENCE GUIDE POSITIONING WATER DRAINAGE SETTING UP AND USING THE APP CARE AND MAINTENANCE TROUBLESHOOTING TECHNICAL DATA 1 2 5 7 9 11 12 13 23 24 25

****** Page 3 ****** SAFETY INSTRUCTIONS IMPORTANT Carefully read the instructions before operating the unit This appliance is for indoor use only and intended for use in a domestic environment only. Any other use is not recommended by the manufacturer and may cause fire, electrical shocks or other injuries to user or property. Rating: This unit must be only connected to a 220-240 V / 50 Hz earthed outlet. Installation must be in accordance with the regulations of the country where the unit is used. If you are in any doubt about the suitability of your electrical supply, have it checked and if necessary, modified by a qualified electrician. This dehumidifier has been tested and is safe to use. However, as with any electrical appliance – use it with care. Disconnect the power before dismantling, assembling or cleaning. Avoid touching any moving parts of the appliance. Never insert fingers, pencils or any other objects though the guard This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities. It is also not intended for use by those with a lack of experience and knowledge unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety. Do not leave children unsupervised with this appliance. Do not clean the unit by spraying it or immersing it in water. Never connect the unit to an electrical outlet using an extension cord. If a power outlet is not available, one should be installed by a qualified electrician. Never operate this appliance if the cord, power adapter or plug is damaged. Ensure the power cord is not stretched or exposed to sharp objects/edges. • A damaged power supply cord should be replaced by the manufacturer or a qualified electrician in order to avoid a hazard. Any service other than regular cleaning or filter replacement should be performed by an authorized service representative. Failure to comply could result in a voided warranty. Do not use the appliance for any purpose other than its intended use. Do not tilt the unit while in use. The unit is designed to work only while in a vertical position. This dehumidifier must always be stored and transported upright, otherwise irreparable damage may be caused to the compressor; if in doubt we suggest waiting at least 24 hours before starting the unit. • Avoid restarting the dehumidifier unless 5 minutes have passed since being turned off. This prevents damage to the compressor. Never use the plug as a switch to start or turn off the dehumidifier. Use the provided ON/OFF switch located on the control panel. Always place the unit on a dry and stable surface. The appliance should not be installed in laundry or wet rooms where the humidity is higher than 85% RH Do not dry laundry above the unit to prevent water from entering the dehumidifier. Place the laundry at least 1 meter away from your dehumidifier. 2

****** Page 4 ****** The appliance must be placed in a room without sources of ignition (for example open flames, an operating gas appliance or an operating electric heater). R290 refrigerant gas complies with European environmental directives. R290 has a low GWP (Global Warming Potential) of 3. The CD12PRO-LE contains about 60g of R290 refrigerant gas. • The CD20PRO-LE contains about 75g of R290 refrigerant gas. Do not use or store the CD20PRO-LE in an unventilated space with an area smaller than 4.1m2 per unit. Do not use or store the CD12PRO-LE in an unventilated space with an area smaller than 2.6m2 per unit. If the appliance is installed, used or stored in an unventilated room, the room must be such as to prevent stagnation of possible leaks of refrigerant gas as there could be a danger of fire or explosion should the refrigerant come into contact with electric heaters, stoves or other sources of ignition. Refrigerant gas may be odourless. Do not use the product and contact the retailer for advice, if damage has occurred to the unit which may have compromised the refrigerant system. Any repairs or maintenance must only be carried out on the unit by a suitably qualified engineer. Before opening and servicing the unit, the authorized engineer must be in possession of a copy of the manufacturer’s service manual and must follow the safety information contained within it to ensure all hazards are minimized. The refrigerant system should not be perforated or punctured. Do not place the unit next to heat sources (e.g. electrical fires, fireplaces, etc.) Avoid mishandling the dehumidifier. Dropping, throwing the unit can cause damage to its internals and increases the risks of operating it. Do not store or use gasoline, petrol, paint, solvents or other flammable vapours or liquids in the vicinity of this dehumidifier or any other appliance. This dehumidifier must not be used in spaces where there is a high concentration of gases, solvent or other volatile organic compounds; in very dusty environments; in any domestic, commercial or industrial environment where the air composition is flammable. ENERGY SAVING AND UNIT SAFETY PROTECTION TIPS Do not cover or restrict the airflow from the outlet or inlet grills. Do not operate and follow troubleshoot procedure if the self-opening louvres do not open on power on. For maximum performance, the minimum distance from a wall or objects should be 20 cm Keep the filters or grills of the unit clean. Under normal conditions, filters or grills should only need cleaning once every three weeks (approximately). Since the filters remove airborne particles, more frequent cleaning may be necessary, depending on the air quality. Vacuum both mesh and optional carbon filters and wash the mesh filters with hot soapy water and dry them before placing them back in the unit. 3

****** Page 5 ****** VISUAL SAFETY GUIDE ON WHERE OR WHEN NOT TO USE YOUR DEHUMIDIFIER Exposed to the weather outdoors If an extension lead may become overloaded Where it may be damaged by chemicals Near water Where the power cable may be damaged Where there is a risk or interference by foreign objects If ther power cable wires are frayed or cut On a slope or uneven surface This product is not made for DIY repair Where small children may be left unattended Where there is risk of fire or close to a naked flame If there is a risk of water falling on the unit 4

****** Page 6 ****** INSTALLATION Remove any water from within the water tank before starting the unit. In order to save energy, do not open windows or doors while the unit is running. Place the unit on a hard / flat surface. On first use run the unit continuously for 24 hrs. TO REDUCE NOISE LEVELS: Place a piece of carpet or a rubber mat under the unit to reduce any vibrations while the unit is running. The CDI 2PRO-LE and CD20PRO-LE dehumidifiers use compressor technology to extract water from the environment. Compressor dehumidifiers are ideal for normal domestic or office environments which are heated during the winter months and maintain a temperature above 12-150C. The dehumidifiers are easy to move around on castors and are designed to extract unwanted humidity while saving money due to their power-saving logic. They feature an intelligent humidistat where the desired relative humidity can be adjusted in increments of 5% between 40 and 80% ensuring your room is not dried too much, and power is not wasted. FEATURES Your dehumidifier belongs to the electriQ low energy premium dehumidifiers featuring low power consumption, power- saving logic and advanced air purification option. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 15. Easy to use controls Low energy only uses a fraction of the electricity of similar dehumidifiers Great for up to 3 bed (CD12PRO-LE) and 5 bed (CD20PRO-LE) houses A cost-effective way to combat mould, condensation and damp Smart App control Dries laundry more efficiently than a tumble dryer Designed to complement any modern space Low and High fan speed selection for the best balance between running quietly and maximum water extraction Anti-dust self-closing oscillating louvres for improved airflow Castors for improved mobility Intelligent CPU controlled digital humidistat with 35-80% RH and room humidity display 24 hours start / stop timer Tank operation or permanent drainage option with splash-proof tank Tank full alarm & auto-stop function Air purifier function with UV sterilisation 5

****** Page 7 ****** PARTS 3. Air Outlet 4. Humidity Indicator light 7. Pre -filter/activated Carbon filter 9 . Continuous Drain Port 10 . Back Cover 12 . Power cord OPTIONAL Activated carbon filter (Optional) 1. Louvres 2. Handle 5. Wheels 11 6. Control Panel 8. Air inlet Water tank 6

****** Page 8 ****** CONTROL PANEL Humidity Indicator HUMIDITY • t01CATCR Timer Down Oscillation Up On/Off Water tank full Defrost indicator HIGH • LOW Mode MODE SMART FAN OPERATION POWER TANK FULL DEFROST Power HIGH • LOW POWER MODE HUMIDITY TOICATOR LIGHT MODE SMART • FAN OPERATION • TANK FULL DEFROST POWER Turn the appliance on/off MODE Button Select the function of the unit between SMART / HIGH / LOW / and FAN. The LED’s next to the button will show which mode is selected. SMART MODE: The unit will default to SMART mode the first time it is switched on and remains in this mode until another program is chosen. In smart mode, it will aim for a relative humidity of 50-55%, and the fan speed will be adjusted automatically. HIGH: The unit will dehumidify and aim for the humidity set using the up and down buttons. LOW: The unit will dehumidify and aim for the humidity set using the up and down buttons. FAN: Only the fan will run, and water is not extracted. Use with the UV function for improved air purification HUMIDITY INDICATOR MODE When the appliance is first started, the indicator light will turn on automatically. The colour of the indicator light will change according to the humidity condition of the room it is situated in. RED: High humidity, RH2700/0 ORANGE: Comfortable, 700/0> RH 260% GREEN: Dry, RH OFF UV o Room Temperature Profile: Use to change the name of the dehumidifier and amend user settings. ON 1 OFF Button: Use to turn the unit on or off. Mode: Change the operating mode AUTO/ FAN/ HIGH/ LOW UV: Turn the UV light On and Off. Current Room Temperature: Displays the current room temperature Humidity indicator: This turns the colour changing humidity indicator on the front of the unit on or off. Oscillation: Set the position of the Louvres. 19 Schedule: Set a time for the dehumidifier to turn ON or OFF. A number of scheduled events can be programmed to enable automatic operation.

****** Page 21 ****** SMART SCENES Smart Scenes is a powerful tool providing the option to customise the operation of the dehumidifier based both on conditions within the room and outside influences. This gives the user the option of specifying much more intelligent actions. These are split into two catagories Scene and Automation. SCENE Scene allows for a one touch button to be added to the Home screen. The button can be used to change a number of settings in one go, and can change all the settings within the unit. A number of scenes can easily be setup, allowing the user to easily change between a number of preset configurations. Below is an example of how to set up a scene: 1. Press on the Smart Scene tab at the bottom of the Home screen 2. Press on the Plus in the top right corner to add a smart 3. my home 19.3 All Devices My Home Medi.„ Bedroom scene. Edit Automaticm Intelligent Living Roomm Select Scene to create a new Scene Add Scene Please Select Type Scene 53 One key control or select “Automatic- for automatic. Automation Execute automatically according to weathere device„ No dev.ces Add Device Scenes Smart Setting O Save Please Enter Scene Name Execute following actions Add a execution action Show on dashboard O 4. Press the Pen next to “Please Enter Scene Name” to input the name for your Scene Show on Dashboard: Leave this on if you require the scene to be displayed as a button on the Home Screen Press the Red Plus to add the action required. Then select the dehumidifier from the list of devices. 5. Chose the function, set the value for the function, and then press the back button in the top right corner, to return to the previous screen. Select Function Set Humidity Wind Speed Lock Shake Power Mode 6. Once all the functions required have been added, press the Save button in the top right corner to finalise and save your new Scene 20

****** Page 22 ****** AUTOMATION Automation allows an automatic action to be set up for the device. This can be triggered by the Time, indoor temperature, humidity of the room, weather conditions, and a range of other influences. 1. Press on the Smart Scene tab at the bottom of the Home screen 2. Press on the Plus in the top right corner to add a smart my home 19.3 All Devices My Home Medi.„ Bedroom scene. Edit Automaticm Intelligent Living Roorn No dev.ces Add Device Scenes Smart Setting Please Enter Scene Name Z When any condition is satisfied v When the following conditions are met Execute following actions Add a execution action. O Save O o 4. Setup is very similar to the scene setup on the previous page, and includes an extra section for specifying a trigger for the scene to start. Press the Pen next to ‘Please Enter Scene Name” to input the name for your Scene Press the Red Plus next to “When any condition is satisfied” to add the trigger Press the Red Plus next to “Execute following actions” to add the action required. Then select the dehumidifier from the list of devices. Select Function 6. Chose the function, set the value for the function, and then press the back button in the top right corner, to return to the previous screen. Set Humidity Wind Speed Lock Shake 21 > 3. Select Automation to create a new Automation Scene Add Scene Please Select Type Scene One key control or select “Autornatic• for automate. Automation Execute automatically according to weather. device X 5. Select the condition when the automation should start. A number of triggers can be combined. Select Condition Select Condition for Task Temperature Humidity Weather PM2.5 Air Quality Sunrise/Sunset 7. Once all the functions required have been added, press the Save button in the top right corner to finalise and save your new scene. The automation is now set up, it can be turned on and off using the toggle on the image shown on step 2.

****** Page 23 ****** DEVICE DETAILS SCREEN Device Details Basic Device Information Device Name Device Location Others Share Device Create Group Device Information electriQ CDI 2PRO-LE > > The device details screen gives you the option to edit the details for the devicel, and use some of its additional features. The device details screen can be accessed from the device screen by pressing on the symbol in the top right hand corner. CHANGING THE NAME OF YOUR DEVICE The top option within this allows you to change the name of the device to something relevant to the use of the product, such as “Living Room Dehumidifier”. Within the menu, you also have the option of setting up a pattern lock or change your password. DEVICE SHARING This allows you to share access to the controls of your dehumidifier with friends and family. Help and feedback Check for Firmware Upgrade Remove Device Restore Factory Defaults PROFILE TAB The Profile tab allows you to make changes to the app, such as setting up a username and editing or adding rooms. Within the Profile tab, you are also able to change settings related to the app itself. 22 O a Tap to Set Username Family Management Message Center Help Center More Services Settings Home Smart g Me

****** Page 24 ****** CONNECTION TROUBLESHOOTING 1. 2. 3. 4. 5. 6. 7. Check whether the device is powered on and is in the correct standby mode, if not please refer to the CHANGING BETWEEN CONNECTION MODES section on page 12. Ensure the wifi password has been entered into the app correctly (Case sensitive) Check that the phone is connected to the wifi you are connecting the device to. Ensure the network you are connecting it to is 2.4Ghz (5Ghz wifi networks are not supported), and that there is a strong wifi signal to the item. If your router is dual band, ensure that the 2.4ghz network has a different network name (SSID). Further advice on changing router settings will be available from your Internet service provider / Router manufacturer. Check the settings on the router. Encryption should be WPA2-PSK and authorisation type should be set to AES Try using the alternative connection method. i.e. If connection is failing when attempting to connect through CF mode, try AP mode. CARE AND MAINTENANCE Always shut off the unit and unplug from the mains before cleaning or performing any maintenance. When it is not in use for long periods it is advisable to remove the plug from the power socket. Do not use chemical solvents (such as benzene, alcohol or gasoline) as they may cause irreversible damage to the unit. 1. CLEAN THE GRILLE AND CASE Use water and a mild detergent to clean the washable mesh filters. Do not use bleach or abrasives. Do not splash water directly onto the main unit. Doing so may cause an electrical shock and can lead to the insulation to deteriorate, or cause the unit to rust. The air intake and outlet grilles get soiled easily, so use a vacuum attachment or soft brush to clean. Wipe the dehumidifier body with a soft damp cloth or kitchen towel. Remove the ABS filter frame. If the optional carbon filters are fitted, remove them from the frame and hoover gently approximately every 2-3 weeks. If the mesh filter is dirty hoover it, if it is heavily soiled wash it with warm soapy water and dry thoroughly before reinserting it in the unit. When filter cleaning is finished and filters are dry placed them back into the unit. NOTE: While the carbon filter is optional never run the unit without the mesh filter frame correctly inserted. 2. CLEAN THE WATER TANK Every few weeks, clean the tank to prevent the growth of mould, mildew and bacteria. Partially fill the tank with clean water and add a little mild detergent. Swish it around and then empty the tank and rinse. NOTE: Do not use a dishwasher to clean the tank. After cleaning and drying, the tank must be reinserted securely into dehumidifier in order to restart operation. END OF SEASON MAINTENANCE 1. Empty and clean the water tank. 2. Clean the unit and the filters as per the cleaning procedure above. 3. Coil the power cord on the special cord storage rest at the back of the unit. 4. Cover the unit and keep it in a dry place. 23

****** Page 25 ****** FREQUENTLY ASKED QUESTIONS Why doesn’t the dehumidifier seem to extract much water if the temperature is low? This is a compressor dehumidifier which works best in temperatures above 150C. If the temperature is low and the air is dryer than the setting on the humidistat the unit will not extract water. If you want to use a dehumidifier for outside buildings, unheated properties, boats or garages please check our desiccant range. Why doesn’t the unit work lor stops suddenly? The water tank may be full or displaced. To rectify: empty the tank and carefully place the tank back in the unit. Also the unit may be running in dehumidifying mode with a low room temperature. Please check if the room temperature is lower than 50C. If so, the unit will stop working while in dehumidifying mode. (unit may be defrosting). The ambient operating range is between 50C and 350C with a relative humidity ranging from 30% to 80%. For maximum efficiency use the unit between 150C and 320C. Sometimes cold and/or hot air comes out from the air outlet grill, why? When the unit is in dehumidifying mode it absorbs humid air from room and freezes it to reduce the humidity. During the cold cycle there should be cold air coming out of the unit During the hot cycle hot dry air should be coming out of the outlet grill. TROUBLESHOOTING Issue Hot or cold air being produced Unit does not operate Front louvres do not open Dehumidifier does not extract water Airflow seems weak Unit is noisy during operation E3 or E4 El or E2 E5 or E6 Defrost light on and unit sto s re ularl Tank full red li ht Cause Normal Operation Is the plug properly inserted in the socket? Does the tank full indicator is red? Louvre motor is blocked Is the unit set to a humidity level lower than the one in the room? Is the temperature too low for water extraction to be efficient? Is any intake grill or discharge blocked? Is the unit too close to walls. Is filter dirty or clo ed? Is the unit on an uneven surface? Is filter clo ed? Humidity sensor error Temperature sensor Abnormal Coil sensor tem erature or current Unit is defrosting Water tank full notification Solution When the unit is in dehumidifying mode it absorbs humid air from room and freezes it to reduce the humidity. During the cold cycle there should be cold air coming out of the unit Durin the defrost c cle hotd air should be comin out of the outlet rill. Insert the plug into the socket and turn the switch on. Tank full, float displaced or tank not properly inserted. Empty tank, check float and make sure tank is ro erl inserted in unit. Check if anything is blocking the louvre Try to move gently the louvres up and down while the unit if off If the above fails return the unit to service centre Set the humidity level on the humidistat bellow current humidity reading Increase temperature in the room or reposition the unit. Remove obstructions and restart the unit. Ensure a distance of at least 20 [cm between the unit & walls Please service the filters regularly as per user manual. Please place on flat horizontal surface. Please service the filters re ularl as er user manual. Use the unit within the prescribed humidity range. Unplug the unit, rest and lu it back in. If error re eats, call for service centre. Use the unit within the prescribed temperature range. Unplug the unit, rest and lu it back in. If error re eats, call for service centre. Use the unit within the prescribed humidity and temperature range. Unplug the unit, rest and lu it back in. If error re eats, call for service centre. Allow the unit to automatically defrost. The protection will clear after the unit self defrosts. Increase temperature in the room if this repeats too often Tank is full or is not in the right position– Empty the tank and replace in the ri ht osition. Any other malfunctions will need to be reported to electriQ service centre. Do not attempt unauthorised repairs as these may invalidate the warrant

****** Page 26 ****** TECHNICAL DATA Model Voltage Dehumidifying capacity Fan Speeds Power Consumption Running Amps Tank Capacity Humidity settings range IP RATING Refrigerant Airflow m3/h High / Low Pressure Max noise level dB(A) Filters Dimensions mm (WxDxH) Weight kgs GWP CD12PRO-LE 1 Ph, 220-240V 50Hz 12 L/ day (at 300 C / 800/0RH) 2 180W 0.91 Amps 4 litres 800/0 PXI R290, 60 grams 180 1.5/O.5MPa 42-49 carbon (optional) 380x580x195 14 3 CD20PRO-LE I Ph, 220-240V 50Hz 20 L/ day (at 300 C / 800/0RH) 2 270W 1.2 Amps 4 litres 800/0 IPXI R290, 75 grams 180 1.5/O.5MPa 42-49 carbon (optional) 380x580x195 14.3 3 All information provided is for reference only. Products specifications may change due to continuous product development. 25

****** Page 27 ****** electriQ UK SUPPORT electriQ.co.uk/support Office hours: 9AM – 5PM Monday to Friday Unit J6, Lowfields Business Park Lowfields Way, Elland West Yorkshire, HX5 9DA DECLARATION OF CONFORMITY Hereby, electriQ declares that this Portable air conditioner is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: electriQ.co.uk/content/declaration-of-conformity DISPOSAL: Do not dispose this product as unsorted municipal waste. Collection of such waste must be handled separately as special treatment is necessary. Recycling facilities are now available for all customers at which you can deposit your old electrical products. Customers will be able to take any old electrical equipment to participating civic amenity sites run by their local councils. Please remember that this equipment will be further handled during the recycling process, so please be considerate when depositing your equipment. Please contact the local council for details of your local household waste recycling centres. V20190827 26

FREE ENGLISH PDF

OPERATING INSTRUCTIONS

USER GUIDE – USER MANUAL

OWNER GUIDE – OWNER MANUAL

REFERENCE GUIDE – REFERENCE MANUAL

INSTRUCTION GUIDE – INSTRUCTION MANUAL



ELECTRIQ CD20PRO-LE (01) PDF MANUAL

Leave a comment, question, review or page error below. Account not required.

This site uses Akismet to reduce spam. Learn how your comment data is processed.