****** Page 1 ****** USER MANUAL CDIOL-V5 10 LITRE COMPRESSOR DEHUMIDIFIER Thank you for choosing electriQ. Please read this user manual before using this innovative dehumidifier and keep it safe for future reference Visit our page electriQ.co.uk for our entire range of Intelligent Electricals
****** Page 2 ****** SETTLING IN 0K? We hope this has been helpful to you. We would love to see how you’re getting on with your new purchase, so please share any snaps you have on the platform of your choice below. Our community awaits your uploads – Snap, tag and hashtag away! ooo @eIectriQUK #eIectriQUK WE’RE HERE TO HELP Should you have any problems or questions with your purchase, please contact a member of our customer service team. 0330 390 3061 support@electriQ.co.uk Mon-Fri 1 9am to 5pm Unit J6, Lowfields Business Park, Lowfields Way, Elland West Yorkshire, HX5 9DA 1
****** Page 3 ****** CONTENTS SAFETY INSTRUCTIONS VISUAL SAFETY GUIDE FEATURES INSTALLATION POSITIONING THE DEHUMIDIFIER PARTS CONTROL PANEL WATER DRAINAGE CARE AND MAINTENANCE TROUBLESHOOTING TECHNICAL DATA SUPPORT 2 3 5 5 6 6 7 8 9 11 12 13 14
****** Page 4 ****** SAFETY INSTRUCTIONS IMPORTANT Carefully read the instructions before operating the unit This appliance is for indoor use only and intended for use in a domestic environment only. Any other use is not recommended by the manufacturer and may cause fire, electrical shocks or other injury to user or property. Rating: This unit must be only connected to a 220-240 V / 50 Hz earthed outlet. Installation must be in accordance with regulations of the country where the unit is used. If you are in any doubt about the suitability of your electrical supply have it checked and if necessary, modified by a qualified electrician. This dehumidifier has been tested and is safe to use. However, as with any electrical appliance – use it with care. Disconnect the power before dismantling, assembling or cleaning. Avoid touching any moving parts within the appliance. Never insert fingers, pencils or any other objects though the guard This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities. It is also not intended for use by those with a lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety. Do not leave children unsupervised with this appliance. Do not clean the unit by spraying it or immersing it in water. Never connect the unit to an electrical outlet using an extension cord. If a power outlet is not available, one should be installed by a qualified electrician. Never operate this appliance if the cord, power adapter or plug is damaged. Ensure the power cord is not stretched or exposed to sharp objects/edges. A damaged power supply cord should be replaced by the manufacturer or a qualified electrician in order to avoid a hazard. Any service other than regular cleaning or filter replacement should be performed by an authorised service representative. Failure to comply could result in a voided warranty. Do not use the appliance for any purpose other than its intended use. Do not tilt the unit while in use. The unit is design to work only in vertical position. This dehumidifier must always be stored and transported upright, otherwise irreparable damage may be caused to the compressor; if in doubt we suggest waiting at least 24 hours before starting the unit. Avoid restarting the dehumidifier unless 5 minutes have passed since being turned off. This prevents damage to the compressor. Never use the plug as a switch to start or turn off the dehumidifier. Use the provided Power button located on the control panel. Always place the unit on a dry and stable surface. The appliance should not be installed in laundry or wet rooms where the humidity is higher than RH Do not dry laundry above the unit to prevent water entering the dehumidifier. Place the laundry at least 1 meter away from your dehumidifier. 3
****** Page 5 ****** Before moving the appliance the water tank should be emptied. When carrying the unit, it should be kept upright and suifficiently supported from its base. The appliance must be placed in a room without sources of ignition (for example: open flames, an operating gas appliance or an operating electric heater). R290 refrigerant gas complies with European environmental directives. R290 has a low GWP (Global Warming Potential) of 3. The CDIOL contains about 50g of R290 refrigerant gas. Do not use or store the appliance in an unventilated space with an area smaller than 4m2 per unit. If the appliance is installed, used or stored in an unventilated room, the room must be such as to prevent stagnation of possible leaks of refrigerant gas as there could be a danger of fire or explosion should the refrigerant come into contact with electric heaters, stoves or other sources of ignition. Refrigerant gas may be odourless. Do not use the product and contact the retailer for advice, if damage has occurred to the unit which may have compromised the refrigerant system. Any repairs or maintenance must only be carried out on the unit by a suitably qualified engineer. Before opening and servicing the unit the authorized engineer must be in possession of a copy of the manufacturer’s service manual and must follow the safety information contained within it to ensure all hazards are minimized. The refrigerant system should not be perforated or punctured. Do not place the unit next to heat sources (e.g. electrical fires, fireplaces, etc.) Avoid mishandling the dehumidifier. Dropping, throwing the unit can cause damage to its internals and increases the risks of operating it. Do not store or use gasoline, petrol, paint, solvents or other flammable vapours or liquids in the vicinity of this dehumidifier or any other appliance. This dehumidifier must not be used in spaces where there is a high concentration of gases, solvent or other volatile organic compounds; in very dusty environments; in any domestic, commercial or industrial environment where the air composition is flammable. ENERGY SAVING AND UNIT SAFETY PROTECTION TIPS Do not cover or restrict the airflow from the outlet or inlet grills. Do not operate and follow troubleshoot procedure if the self-opening louvers do not open on power on. For maximum performance the minimum distance from a wall or objects should be 20 cm Keep the filters or grills of the unit clean. Under normal conditions, filters or grills should only need cleaning once every three weeks (approximately). Since the filters remove airborne particles, more frequent cleaning maybe necessary, depending on the air quality. Vacuum both mesh and optional carbon filters and wash the mesh filters with hot soapy water and dry them before placing them back in the unit. 4
****** Page 6 ****** QUICK VISUAL SAFETY GUIDE ON WHERE OR WHEN NOT TO USE YOUR DEHUMIDIFIER Exposed to the weather outdoors If an extension lead may become overloaded Where it may be damaged by chemicals FEATURES Near water Where the power cable may be damaged Where there is a risk or interference by foreign objects If ther power cable wires are frayed or cut On a slope or uneven surface This product is not made for DIY repair Where small children may be left unattended Where there is risk of fire or close to a naked flame If there is a risk of water falling on the unit Your dehumidifier belongs to the electriQ dehumidifier range. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. Easy to use controls Great for up to 3 bed houses Lightweight and portable Cost effective way to combat mould, condensation and damp Laundry mode – dries laundry more efficiently than a tumble dryer Designed to complement any modern space Intelligent CPU controlled digital humidistat with 35-80% RH and room humidity display 24 hours stop timer Easy to remove front tank. Tank operation or permanent drainage option Tank full alarm & auto-stop function Auto restart following power cut. 5
****** Page 7 ****** INSTALLATION Remove any water from within the water tank before starting the unit. In order to save energy do not open windows or doors while the unit is running. Place the unit on a hard / flat surface. On first use run the unit continuously for 24 hrs. TO REDUCE NOISE LEVELS: Place a piece of carpet or a rubber mat under the unit to reduce any vibrations while the unit is running. The CDIOL dehumidifier uses compressor technology to extract water from the environment. Compressor dehumidifiers are ideal for normal domestic or office environments which are heated during the winter months and maintain a temperature above 12-150C. Your dehumidifier is lightweight and easy to move. It is designed to extract unwanted humidity while saving money due to its power saving logic. The unit features an intelligent humidistat where the desired relative humidity can be adjusted in increments of 5% between 35 and 80% ensuring your room is not dried too much and power is not wasted. POSITIONING THE DEHUMIDIFIER A badly positioned dehumidifier will have little effect. In positioning the dehumidifier please ensure circulation of air in not restricted around the unit. Allow at least 20 cm space around the unit. This dehumidifier is designed only for indoor residential or small office applications and any commercial or industrial use will invalidate the warranty. Use in an enclosed area for maximum efficiency. Close all doors, windows to create an effective operating environment. Do not use outdoors. 20cn 5 Ocm 20cm 20cm Your electriQ dehumidifier will begin to protect your space from the harmful effects of excessive moisture as soon as it is turned on. Excess moisture is dispersed throughout your home. For this reason, the dehumidifier should be positioned in a central and clear location so that it can draw this moist air towards it from all over the home. A warm hallway or landing is an excellent position for your dehumidifier. If possible, leave interior doors ajar to allow air circulation. Alternatively, if you have a serious problem in one area you can begin by positioning the dehumidifier there and moving it to a more central location at a later date. For the most effective use, run your dehumidifier with external doors and windows kept closed. Please note the unit should not be placed directly against a radiator or other heat source. Before moving the appliance the water tank should be emptied. When carrying the unit, it should be kept upright and suifficiently supported from its base. When positioning your electriQ dehumidifier, ensure that it is placed clear of any obstacle that may limit the air movement. Place the dehumidifier on a flat dry surface. 6
****** Page 8 ****** PARTS HUMIDITY INDICATOR AIR INLET OPTIONAL CONTROL PANEL AIR OUTLET WATER TANK CASTORS CONTINOUS DRAINAGE PORT To fit the filters, remove the filter frame from tha air inlet, and place them flush within the air inlet. If using both the Carbon and HEPA filters in combination, the Carbon filter should be inserted first. CARBON FILTER Replacement Activated carbon filters are available from the retailer under reference: ACFlL-CDIOL-V5 7 HEPA FILTER Replacement HEPA filters are available from the retailer under reference: HEPA-CDIOL-V5
****** Page 9 ****** CONTROL PANEL TIMER TIMER Q) O HIGH FAN O AUTO O LAUNDRY O HUMIDITY INDICATOR HUMIDITY INDICATOR POWER TARGET HUMIDITY TARGET HUMIDITY MODE MODE POWER POWER Turn the appliance on/off MODE Select the operating mode of the unit between Laundry and Auto. The fan will operate continuously to monitor the humidity. AUTO MODE: The unit will start dehumidifying when the humidity increases to 5% above the desired humidity and will stop when the humidity drops to 5% below the desired humidity. The default desired humidity is 55% RH LAUNDRY MODE: The unit will dehumidify continuously unless the water tank is full or the unit is going through its defrost cycle. This is ideal for drying clothes. TARGET HUMIDITY During Auto Mode press to adjust the desired humidity of the room. This can be changed between 35% and 80% in 5% increments. The unit will initially default to FAN SPEED Press to change between HIGH and LOW fan speeds. HUMIDITY INDICATOR When the appliance is started,the indicator light will turn on automatically. The indicator light colour will change according to the humidity. RED: High humidity RH2700/0 ORANGE: Above ideal humidty 700/0>RH2600/0 GREEN: Ideal humidity RH<600/0 Press the HUMIDITY INDICATOR button to turn the humidity display on or off. NOTE: It can take around 2 minutes after the humidity has changed for the colour indicator to change, for example, if the humidty drops to 55%, it may take 2 minutes for the indicator to change to green. TIMER Press the TIMER button to program the timer. When the timer is activated the "TIMER" light will be illuminated. Before programming the timer, ensure the timer function has not been activated (the light must be off). The following timer programs are available. DELAYED POWER-OFF FUNCTION: While the appliance is running with the desired settings, repeatedly press the TIMER button to set in how many hours time you require the unit to stop (004 hours). 8 ****** Page 10 ****** DISPLAY 88 NOTES Shows the desired humidity when the TARGET HUMIDITY button is pressed Shows the timer duration when the TIMER button is pressed If a permanent drainage pipe is fitted the unit will not stop operating. Setting the desired humidity to around 35% is good for laundry mode, a quick drying boost, or in emergencies. It is not recommended for long normal operation in a domestic or office environment. To allow more moisture in the air, set a higher desired humidity (e.g. 60-70%). We recommend setting the desired humidity to 50-55%. This is great for domestic operation and dry storage Setting the humidity to 60% is great for personal comfort and applications where 50% RH is considered too dry Setting the humidity to 70% is ideal for unoccupied properties or where an economical run is needed without the need to reduce the humidity further. OTHER FEATURES AND INDICATORS TANK FULL INDICATION When the water tank is full, removed or incorrectly inserted the unit will stop dehumidifying, E2 will display and the unit will bleep. Empty the tank and reinsert it correctly to resume operation. AUTO DEFROST When frost builds up on the evaporator coils, the compressor will cycle off and the unit will go in to defrost mode. Following completion of the defrost mode, the unit will return to the previously operating settings. e When the unit is running in a room with a temperature between OOC and 120C, it will enter defrost mode for 8 minutes roughly every 30minutes. • When the unit is running in a room with a temperature between 12 oc and 160C, defrost mode for 5 minutes roughly every 60minutes. e When the unit is running in a room with a temperature between 160C and 200C, defrost mode for 5 minutes roughly every 90minutes. AUTO MODE it will enter it will enter When the humidity of the room is 5% lower than the desired humidity the compressor will turn off automatically but the fan will continue to operate to ensure that the air within the room is not stale. The unit will use only a minimal amount of energy in fan mode. When the humidity of the room is 5% higher than the desired humidity the compressor will restart after a 3 minutes delay to protect the compressor. POWER After the unit has stopped, to protect the compressor it is not recommended to resume operation for at least 5 minutes. Operation can resume after this period lapses. When the unit is restarted there is a 3 minutes delay before compressor will start. 9 ****** Page 11 ****** WATER DRAINAGE When the water tank is full, the unit will stop automatically. When this happens the unit will display E2 on the control panel. NOTE: Only empty the water tank when it is full or before moving or storing the unit. There are two ways to dispense collected water. USE THE TANK When the tank is full, the unit will automatically stop running, and E2 will display on the control panel. Slowly pull out the tank. Empty the water tank and reinsert it into the dehumidifier. The tank must be in place and securely seated for the dehumidifier to operate again. The dehumidifier will re-start when the tank is restored in its correct position. NOTES: When you remove the water tank, do not touch sensors or any parts which are situated behind tank. Doing so may damage the product. Be sure to push the tank gently all the way into the unit. Banging the bucket against anything or failing to push it in securely into place may cause the unit not to operate. Do not remove any parts from the water tank or tank enclosure. The water full sensor will no longer be able to detect the water level correctly and water may leak from the water tank. CONTINUOUS DRAINAGE Water can be automatically plumbed in or drained into a sink, a larger recipient or through the wall into an outside drain by attaching a pipe to the unit (9 mm internal diameter). A 1.5m pipe is supplied, although longer pipes can be used. Insert the pipe into the drain outlet at the back of the unit as shown here. Make sure the connection between pipe and the drain outlet is tight and does not leak. Then direct the pipe to a suitable drainage point. This unit uses gravity to dispose of water hence the drain should be lower than the water outlet on the unit. Put the tank back. Be sure to run the water pipe downward and let the water to flow out smoothly. Do not kink or bend the pipe. The permanent drain can be used in conjunction with an external water pump (e.g. when draining from a cellar) to lift the water upwards. 10 ****** Page 12 ****** CARE AND MAINTENANCE Always shut off the unit and unplug from the mains before cleaning or performing any maintenance. When it is not in use for long periods it is advisable to remove the plug from the power socket. Do not use chemical solvents (such as benzene, alcohol or gasoline) as they may cause irreversible damage to the unit. 1. CLEAN THE GRILLE AND CASE Use water and a mild detergent to clean the washable filter frame. Do not use bleach or abrasives. Do not splash water directly onto the main unit. Doing so may cause an electric shock and can lead to the insulation to deteriorate, or cause the unit to rust. The air intake and outlet grilles get soiled easily, so use a vacuum attachment or soft brush to clean. Wipe the dehumidifier body with a sof t damp cloth or kitchen towel. Remove the filter frame. If the optional carbon filters are fitted, remove them from the frame and hoover gently approcimately every 2-3 weeks. If the mesh filter is dirty hoover it, if it is heavily soiled wash it with warm soapy water and dry thoroughly before reinserting it in the unit. When filter cleaning is finished and filters are dry placed them back into the unit. NOTE: While the carbon and HEPA filters is optional, never run the unit without the filter frame correctly inserted. 2. CLEAN THE WATER TANK Every few weeks, clean the tank to prevent growth of mould, mildew and bacteria. Partially fill the tank with clean water and add a little mild detergent. Swish it around and than empty the tank and rinse. NOTE: Do not use a dishwasher to clean the tank. After cleaning and drying, the tank must be reinserted securely into dehumidifier in order to restart operation. END OF SEASON MAINTENANCE 1. 2. 3. 4. 5. Run the unit for at least 30 minutes with the desired humidity set to max, this will allow the unit to internally dry. After 30 minutes, empty and clean the water tank, ensuring it is fully dry before reinserting into the unit. Clean the unit and the filters as per cleaning procedure above. Coil the power cord on the special cord storage rest at the back of the unit Cover the unit and keep it in a dry place. 11 ****** Page 13 ****** FREQUENTLY ASKED QUESTIONS Why doesn't the dehumidifier seem to extract much water if the temperature is low? This is a compressor dehumidifier which works best in temperatures above 150C. If the temperature is low and the air is dryer than the setting on the humidistat the unit will not extract water. If you want to use a dehumidifier for outside buildings, unheated properties, boats or garages please check our desiccant range. Why doesn't the unit work /or stops suddenly? The water tank may be full or displaced. To rectify: empty the tank and carefully place the tank back in the unit. Also the unit may be running in dehumidifying mode with a low room temperature. Please check if the room temperature is lower than 50C. If so, the unit will stop working while in dehumidifying mode. (unit may be defrosting). The ambient operating range is between 50C and 350C with a relative humidity ranging from 35% to 80%. For maximum efficiency use the unit between 150C and 320C. Sometimes cold and/or hot air comes out from the air outlet grill, why? When the unit is in dehumidifying mode it absorbs humid air from room and freezes it to reduce the humidity. During the cold cycle there should be cold air coming out of the unit. During the hot cycle hot dry air should be coming out of the outlet grill. TROUBLESHOOTING Issue Hot or cold air being produced Unit does not operate Dehumidifier does not extract water Airflow seems weak Unit is noisy during operation Q Error Code Ca use Normal Operation Is the plug properly inserted in the socket? Is E2 displayed on the control panel Is the unit set to a humidity level lower than the one in the room? Is the temperature too low for water extraction to be efficient? Is any intake grill or discharge blocked? Is the unit too close to walls. Is filter dirty or clogged? Is the unit on an uneven surface? Is filter clogged? Water tank is full Solution When the unit is in dehumidifying mode it absorbs humid air from room and freezes it to reduce the humidity. During the cold cycle there should be cold air coming out of the unit During the defrost cycle hot dry air should be coming out of the outlet grill. Insert the plug into the socket and turn the switch on. Tank full, float displaced or tank not properly inserted. Empty tank, check float and make sure tank is properly inserted in unit. Set the humidity level on the humidistat bellow current humidity reading. Increase temperature in the room or reposition the unit. Remove obstructions and restart the unit. Ensure a distance of at least 20 [cm between the unit & walls Please service the filters regularly as per user manual. Please place on flat horizontal surface. Please service the filters regularly as per user manual. Tank full, float displaced or tank not properly inserted. Empty tank, check float and make sure tank is properly inserted in unit. Any other malfunctions will need to be reported to electriQ service centre. Do not attempt unauthorised repairs as these may invalidate the warranty. 12 ****** Page 14 ****** TECHNICAL DATA Model Voltage Dehumidifying capacity Fan Speeds Power Consumption Running Amps Tank Ca pacity Desired Humidity Range IP Rating High / Low Pressure Filters Dimensions mm (WxDxH) Weight (Kgs) Refrigerant GWP CDIOL-V5 220-240V—50Hz IOL / day (at 300 C/ 800/0RH) 2 240W 1.3 Amps 2.4 litres 35 – 'PXI 3.2/0.7MPa Carbon (Optional) 260x220x480(mm) 9 R290, 50 grams 3 I-JK R290 Disposal: Do not dispose this product as unsorted waste. Collection of such waste must be handled separately as special treatment is necessary. Recycling facilities are now available for all customers at which you can deposit your old electrical products. Customers will be able to take any old electrical equipment to participating sites run by their local councils. Please remember that this equipment will be further handled during the recycling process, so please be considerate when depositing your equipment. Please contact the local council for details of your local household waste recycling centres. 13 ****** Page 15 ****** electriQ UK SUPPORT electriQ.co.uk/support Please, for your own convenience, make these simple checks before calling the service line. 1. 2. 3. 4. 5. 6. Has the unit been standing upright for at least 2 hours? Is the unit plugged into the mains? Is the fuse 0K? Switch the unit off and wait three minutes to see if the issue is resolved. Restart the unit. Check if the water tank is full. Was the troubleshooting guide followed? If the unit still fails to operate call: 0330 390 3061 or complete the online form Office hours: 9AM – 5PM Monday to Friday Unit J6, Lowfields Business Park, Lowfields Way, Elland West Yorkshire, HX5 9DA 14 V20221108