What components are included in the DRUCK DPI620PC Pressure Calibrator Package?
The DRUCK DPI620PC package contains the following items:
DPI620G Genii Calibrator
PV621G Pressure Generation Station
PM620 Pressure Module
4Sight2 Calibration Management Software
How do I install the battery in the DRUCK DPI620PC?
To install the IO620-BATTERY in your DRUCK DPI620PC, follow these steps:
Step 1. Remove the five Pozidriv screws (A) from the device.
Step 2. Remove the battery cover.
Step 3. Align the battery connections with the connections located in the battery compartment.
Step 4. Place the battery into the battery compartment.
Step 5. Replace the battery cover.
Step 6. Secure the cover back in place with the five Pozidriv screws (A).
Step 7. Connect the battery charger and allow the battery to fully charge before initial use.
How do I charge and attach the battery for the intrinsically safe version of the DRUCK DPI620PC?
For the intrinsically safe components of the DRUCK DPI620PC package, follow these procedures for the IO620G-IS-BATTERY:
To charge the battery:
Step 1. Fit the battery to the battery cradle.
Step 2. Connect the battery charger and allow it to fully charge before use.
To attach the battery to the calibrator:
Step 1. Align the battery with the Intrinsically Safe Calibrator.
Step 2. Secure the battery to the calibrator using the provided thumb screws.
How is the DRUCK DPI620PC Pressure Calibrator set up for operation?
To set up the DRUCK DPI620PC Pressure Calibrator, follow these assembly steps:
Step 1. Place the Calibrator unit onto the Pressure Generation Station and latch it into position.
Step 2. Hand tighten the Pressure Module into the sensor port of the Pressure Generation Station.
Note: For the intrinsically safe version of the DRUCK DPI620PC, place the Intrinsically Safe Calibrator onto the Intrinsically Safe Pressure Generation Station until it latches, then hand tighten the Intrinsically Safe Pressure Module into the sensor port.
How do I install the 4Sight2 Calibration Management Software for the DRUCK DPI620PC?
To install the software for the DRUCK DPI620PC:
Step 1. Refer to the instructions provided in the software quick start guide.
Step 2. Contact the manufacturer to unlock the Lite license for the software.
What are the primary components of the DRUCK DPI620PC Intrinsically Safe Package?
The intrinsically safe version of the DRUCK DPI620PC includes the following items:
DPI620G-IS Intrinsically Safe Calibrator
PV621-IS Intrinsically Safe Pressure Generation Station
PM620-IS Intrinsically Safe Pressure Module
4Sight2 Calibration Management Software