What standards and code approvals does the DIMPLEX BFSL33 comply with?

The DIMPLEX BFSL33 has been tested in accordance with the UL 2021 and CSA C22.2 No. 46 standards for fixed and location-dedicated electric room heaters.


What are the electrical specifications for the DIMPLEX BFSL33?

Voltage (Volts) Rated Power (Watts) Remote Control Wall Thermostat No Heat 120 Volt AMPS 120 Volt AMPS 208 Volt AMPS 240 Volt AMPS
120/120/208/240 8/1223/1823/2423 3 Stage Optional 0.07A 10.2A 8.7A 10.1A

What components are included in the power ratings for the DIMPLEX BFSL33?

The power ratings shown for the DIMPLEX BFSL33 include LED lights and motors, which account for 10 watts.


What electrical code compliance warning applies to the DIMPLEX BFSL33?

The installation of the DIMPLEX BFSL33 must comply with applicable Local and/or National Electrical Codes and utility requirements. The installation should be entrusted to duly qualified personnel where required by law.


How are Note, Caution, and Warning defined for the DIMPLEX BFSL33?

NOTE: Procedures and techniques that are considered important enough to emphasize.

CAUTION: Procedures and techniques which, if not carefully followed, will result in damage to the equipment.

WARNING: Procedures and techniques which, if not carefully followed, will expose the user to the risk of fire, serious injury, or death.


What is the step-by-step installation overview for the DIMPLEX BFSL33?

1. Rough in framing opening following recommended framing dimensions.

2. Allow 8 inches (20.3 cm) of service cable when installing before finishing wall, or up to 4 feet (121.9 cm) when installing after finishing wall. Strip individual conductors 1/2 inch (1.3 cm).

3. Loosen the screw securing the junction box cover and remove the cover.

4. Remove knockouts, if necessary, or use the provided cable clamp.

5. Place unit in position in the framed opening, level with shims if necessary, and attach unit to frame using mounting flanges provided.

6. Verify voltage configuration. The unit is factory wired for 208/240V power supply. Slide the switch and reconfigure the wiring if 120V operation is required.

7. Wire a dedicated, properly fused circuit with a 15 amp rating for the appropriate voltage (120V, 208/240V).

8. Make wall switch and/or wall mounted thermostat connections if applicable.

9. Place all connectors inside the unit and secure the junction box cover. Ensure the cable clamp grips only the jacket of service cable, thermostat, and wall switch lines.


What are the service cable length requirements when installing the DIMPLEX BFSL33?

Allow 8 inches (20.3 cm) of service cable for connecting power supply wire to the junction box on the fireplace when installing before finishing the wall.

Allow up to 4 feet (121.9 cm) of service cable for connecting power supply wire to the junction box on the fireplace when installing after finishing the wall.

Remove the outer jacket and strip the individual conductors 1/2 inch (1.3 cm) from the end.


What are the rough-in framing dimensions for the DIMPLEX BFSL33?

Rough-in framing dimensions are:

Width: 33 1/2 inches (851 mm)

Height: 28 1/2 inches (724 mm)

Depth: 10 inches (254 mm)


What are the exterior firebox dimensions of the DIMPLEX BFSL33?

Width: 33 inches (829 mm)

Height: 28 inches (718 mm)

Depth: 9 1/2 inches (245 mm)


What are the rough-in corner framing dimensions for the DIMPLEX BFSL33?

Corner framing dimensions are:

Back wall depths: 29 1/4 inches (744 mm) by 29 1/4 inches (744 mm)

Front opening width: 41 inches (1041 mm)


What are the clearance to combustibles specifications for the DIMPLEX BFSL33?

The DIMPLEX BFSL33 features a zero clearance design. Combustibles may be installed to the edge of the unit. However, no combustibles can be placed on the top surface of the fireplace. Insulation and vapor barrier should be placed a minimum of 2 inches (5.1 cm) from the unit.


What trim pieces are included with the DIMPLEX BFSL33 and how are they attached?

The DIMPLEX BFSL33 comes with three trim pieces: top and two sides.

The top piece is secured with screws at either end and one in the middle.

The two side pieces require a tab to be inserted in the center slot then secured with a screw at the top and bottom.


Should the trim be installed before or after securing the DIMPLEX BFSL33 in the opening?

The trim should be installed before securing the firebox in the opening.


How do you secure the DIMPLEX BFSL33 using the mounting flanges?

There are two mounting flanges located on each side of the fireplace insert. From the inside of the unit, bend tabs outward and mount to the inside of the framing using suitable hardware.


What are the recommended power supply wire specifications for the DIMPLEX BFSL33?

For 120V installations: Use two conductor, non-metallic sheath cable with ground wire (3 wires total) for the incoming power supply.

For 208V / 240V installations: Use three conductor, non-metallic sheath cable with ground wire (4 wires total) for the incoming power supply.

For wall mounted thermostat and/or wall switch installations: Two conductor, non-metallic sheath cable with ground wire (3 wires total) is recommended.


What wire gauge and fuse ratings are required for the DIMPLEX BFSL33?

Voltage Wire Gauge Fuse Rating
120 Volts 12 Gauge 15 Amp
208 Volts 12 Gauge 15 Amp
240 Volts 12 Gauge 15 Amp

Where is the voltage selector switch located on the DIMPLEX BFSL33?

The voltage selector switch is located inside the exhaust panel on the top right hand corner of the unit.


How do you change the voltage selector switch on the DIMPLEX BFSL33?

Ensure that the power supply is turned off. Carefully insert a flat headed screwdriver inside the exhaust panel to change the switch between 240V (230 position) and 120V (115 position).


Which switch positions correspond to which supply voltages on the DIMPLEX BFSL33?

When wiring the unit for 208V / 240V, the voltage selector switch should be in the 230V position.

When wiring the unit for 120V, the voltage selector switch should be in the 115V position.


What is the factory default voltage configuration of the DIMPLEX BFSL33?

The unit is factory configured and wired for 208/240V operation.


Where are the power connection wires located inside the junction box of the DIMPLEX BFSL33?

Wires L1, L2, N, and G are attached to the rear of the junction box cable clamp for easy access.


How do you complete direct power wiring for 240V installation on the DIMPLEX BFSL33?

1. Locate the voltage selector switch inside the exhaust panel on the top right hand corner of the unit. Ensure that the switch is in the 240V position (230 is printed on switch).

2. Loosen the screw securing the junction box cover and remove the cover.

3. Remove the knockouts (if necessary) or use the provided cable clamp.

4. Pull out the four wires marked L1, L2, N, and G.

5. Connect L1 (black) from the unit to the L1 (black) from the power supply.

6. Connect L2 (red) from the unit to the L2 (red) from the power supply.

7. Connect N (white) from the unit to the Neutral (white) from the power supply.

8. Connect the ground wire (green) from the unit to the ground from the power supply.

9. Ensure that all connections are tight.

10. Insert all the wiring back into the unit and secure with a cable clamp.


How do you wire the DIMPLEX BFSL33 directly for 120V installation?

1. Locate the voltage selector switch inside the exhaust panel on the top right hand corner of the unit. Flip the switch from 240V to 120V configuration (230 and 115 is printed on switch).

2. Loosen the screw securing the junction box cover and remove the cover.

3. Remove the knockouts (if necessary) or use the provided cable clamp.

4. Pull out the four wires marked L1, L2, N, and G.

5. Connect L1 (black) wire from the unit to the L1 (black) from the power supply.

6. Connect L2 (red) and N (white) from the unit to the Neutral (white) from the power supply.

7. Connect the ground wire (green) from the unit to the ground from the power supply.

8. When the unit has been configured for the appropriate power supply voltage, ensure that all connections are tight.

9. Insert all the wiring back into the unit and secure with a cable clamp.


How do you wire the DIMPLEX BFSL33 for a 120V no-heat installation?

1. Locate the voltage selector switch inside the exhaust panel on the top right hand corner of the unit. Flip the switch from 240V to 120V configuration (230 and 115 is printed on switch).

2. Loosen the screw securing the junction box cover and remove the cover.

3. Remove the knockouts (if necessary) or use the provided cable clamp.

4. Pull out the four wires marked L1, L2, N, and G.

5. Connect L1 (black) wire from the unit to the L1 (black) from the power supply.

6. Connect L2 (red) and N (white) from the unit to the Neutral (white) from the power supply.

7. Connect the ground wire (green) from the unit to the ground from the power supply.

8. Locate and separate, by installing a wire nut on the 1 (red) and 2 (red) wires individually.

9. Ensure that all connections are tight.

10. Insert all the wiring back into the unit and secure with a cable clamp.


Is a dedicated circuit required if the DIMPLEX BFSL33 is installed with no heat?

If wiring the unit to operate with NO heat, a dedicated circuit may not be required.


Is a wall switch recommended to control main power for 240V on the DIMPLEX BFSL33?

No, the use of a wall switch to control the main power for 240V is not recommended. To control the unit remotely, the use of a Dimplex Wall Remote (WRCPF-KIT) is suggested (sold separately).


What wiring preparation is required before installing a 120V main power wall switch on the DIMPLEX BFSL33?

Before installing the unit, have the following wires installed:

A 2 conductor wire with ground (3 wires total) from the power supply panel to the main switch wall box.

A 2 conductor wire with ground (3 wires total) from the main switch wall box to the junction box on the unit.

Use a single pole, single throw (On/Off) wall switch that is rated for a minimum of 15 amps.


How do you connect a 120V main power wall switch to the DIMPLEX BFSL33?

1. Locate the voltage selector switch inside the exhaust panel on the top right hand corner of the unit. Ensure that the switch is in the 120V position (115 printed on switch).

2. Loosen the screw securing the junction box cover and remove the cover.

3. Remove the knockouts (if necessary) or use the provided cable clamp.

4. Pull out the four wires marked L1, L2, N, and G (black, red, white and green).

5. Connect L1 (black) from the unit to the L1 (black) from the main power wall switch using a wire connector (not supplied).

6. Connect the other end of L1 (black) to the L1 terminal of the main power wall switch.

7. Connect L2 (red) from the unit and N (white) from the unit to the Neutral wire (white) of the main power wall switch by using a wire connector (not supplied).

8. Connect the other end of the N (white) to the Neutral wire (white) from the power supply panel by using a wire connector (not supplied).

9. Connect Ground (green) from the unit to the Ground (green) wire of the main power wall switch by using a wire connector (not supplied).

10. Connect L1 (black) wire from the power supply to the L1 terminal of the main power wall switch.

11. Secure the 2 remaining Ground wires (green) with a ground screw in the main switch wall box.

12. Ensure that all connections are tight.

13. Insert all the wiring of the main power wall switch into the main switch wall box.

14. Insert all the wiring back into the unit and secure with a cable clamp.


How do you wire a 120V main power wall switch with no heat on the DIMPLEX BFSL33?

Follow the standard 120V main power wall switch installation steps and locate and separate by wire nut the 1 (red) and 2 (red) wires. This disables the heater operation while allowing the wall switch to control main power.


What wiring preparation is required before installing a 120V heater wall switch control on the DIMPLEX BFSL33?

Before installing the unit, complete the following:

Install main power connection with appropriate wiring directly to the main power or through a wall switch.

Install a 2 conductor wire with ground (3 wires total) from the heater switch wall box to the junction box on the unit.

Use a heater wall switch (On/Off) that is rated for a minimum of 15 amps.


Can a wall switch be used to control the heater in a 240V installation on the DIMPLEX BFSL33?

The use of a wall switch to control the heater for a 240V installation is not recommended. To control the heater remotely, the use of a Dimplex Wall Remote (WRCPF-KIT) is suggested (sold separately).


How do you connect a 120V heater wall switch control on the DIMPLEX BFSL33?

1. Loosen the screw securing the junction box cover and remove the cover.

2. Remove the knockouts (if necessary) or use the provided cable clamp.

3. Pull out the three wires marked 1, 2, and G (red, red, and green).

4. Remove the wire connector and separate the wires marked 1 and 2.

5. Connect the 1 wire (red) from the unit to the L1 wire (black) from the heater wall switch by using a wire connector (not supplied).

6. Connect the other end of L1 wire (black) from the heater wall switch to the L1 terminal of the heater wall switch.

7. Connect the 2 wire (red) from the unit to the Neutral wire (white) from the heater wall switch using a wire connector (not supplied).

8. Connect the other end of the Neutral wire (white) from the heater wall switch to the L2 terminal of the heater wall switch.

9. Connect the Ground wire (green) from the unit to the Ground wire (green) from the heater wall switch using a wire connector (not supplied).

10. Secure the remaining Ground wire (green) with a ground screw in the heater switch wall box.

11. Ensure that all connections are tight.

12. Insert all the wiring of the heater wall switch into the heater switch wall box.

13. Insert all the wiring back into the unit and secure with a cable clamp.


Can a wall mounted thermostat be used for a 240V installation on the DIMPLEX BFSL33?

The use of a wall mounted thermostat to control a 240V installation is not recommended. To control the unit with a thermostat, the use of a Dimplex Wall Remote (WRCPF-KIT) is suggested (sold separately).


What wiring preparation is required for a 120V wall mounted thermostat on the DIMPLEX BFSL33?

Before installing the unit, complete the following:

Install main power connection with appropriate wiring directly to the main power or through a wall switch.

Install a 2 conductor wire with ground (3 wires total) from the thermostat wall box to the junction box on the unit.

Wiring of the thermostat must be completed prior to installing the unit.


What type of wall thermostat is supported by the 120V installation instructions on the DIMPLEX BFSL33?

The installation instructions are for a single pole thermostat.


How do you connect a 120V wall mounted thermostat to the DIMPLEX BFSL33?

1. Loosen the screw securing the junction box and remove the cover.

2. Remove the knockouts (if necessary) or use the provided cable clamp.

3. Pull out the three wires marked 1, 2, and G (red, red, and green).

4. Remove the wire connector and separate the wires marked 1 and 2.

5. Connect the 1 wire (red) from the unit to the Neutral (white) wire from the wall thermostat box by using a wire connector (not supplied).

6. Connect the other end of the Neutral (white) wire from the thermostat wall box to the red wire from the wall thermostat.

7. Connect the 2 wire (red) from the unit to the black wire from the thermostat wall box by using a wire connector (not supplied).

8. Connect the other end of the black wire from the thermostat wall box to the black wire from the wall thermostat.

9. Connect the Ground wire (green) from the unit to the Ground (green) wire from the thermostat wall box by using a wire connector (not supplied).

10. Connect the other end of the Ground wire (green) to the thermostat wall box ground screw.

11. Ensure that all connections are tight.

12. Insert all the wiring of the wall mounted thermostat into the wall box.

13. Insert all the wiring back into the unit and secure with a cable clamp.


Can a wall mounted flame override switch be used with no-heat installations on the DIMPLEX BFSL33?

No. Do not use the wall mounted flame override switch with no heat installations.


What is the function of the wall mounted flame override switch on the DIMPLEX BFSL33?

The fireplace can be wired to have a wall switch operate the flame independent of the heater.


What are the preliminary wiring requirements for a flame override switch on the DIMPLEX BFSL33?

Before installing the unit, complete the following:

Install main power connection with appropriate wiring directly to the main power or through a wall switch.

Install a 2 conductor wire with ground (3 wires total) from the flame override switch wall box to the junction box on the unit.

Use a wall switch (On/Off) that is rated for a minimum of 15 amps.


How do you wire a 120V / 240V wall mounted flame override switch on the DIMPLEX BFSL33?

1. Loosen the screw securing the junction box cover and remove the cover.

2. Remove the knockouts (if necessary) or use the provided cable clamp.

3. Pull out the three wires marked 3, 4, and G (blue, blue, and green).

4. Remove the wire connector and separate the wires marked 3 and 4.

5. Connect 3 wire (blue) from the unit to the L1 wire (black) from the flame override wall switch by using a wire connector (not supplied).

6. Connect the other end of the L1 wire (black) from the flame override wall switch to the L1 terminal of the flame override wall switch.

7. Connect 4 wire (blue) from the unit to the Neutral wire (white) from the flame override wall switch using a wire connector (not supplied).

8. Connect the other end of the Neutral wire (white) from the flame override wall switch to the L2 terminal of the flame override wall switch.

9. Connect the Ground wire (green) from the unit to the Ground wire (green) from the flame override wall switch using a wire connector (not supplied).

10. Secure the remaining Ground wire (green) with a ground screw in the flame override switch wall box.

11. Ensure that all connections are tight.

12. Insert all the wiring of the switch into the switch wall box.

13. Insert all the wiring back into the unit and secure with a cable clamp.


What are the general features of the WRCP-KIT wall remote used with the DIMPLEX BFSL33?

Can be used for 120V or 240V installations.

Battery or 24V powered.

50 foot (15 m) control range.

Built-in Thermostat.

Flame On/Off Control.

Heat On/Off Control.


What are the controls and indicators on the WRCP-KIT wall remote for the DIMPLEX BFSL33?

1. Room Temperature

2. Set Temperature

3. Flame Effect

4. Purifire

5. Heat Off Indicator

6. Function Lock Indicator

7. RF Code Function Indicator

8. Set Temperature Down

9. Set Temperature Up

10. Flame Off

11. Flame On

12. Purifire Off

13. Purifire On

14. Low Battery Indicator


What is the proper cable clamp securing procedure for junction box wiring on the DIMPLEX BFSL33?

Place all connectors inside the unit and secure the junction box cover to the unit. Ensure that the cable clamp grips only the jacket of the service cable, thermostat, and (if applicable) wall switch lines.


What color wires are used for the flame override switch inside the DIMPLEX BFSL33 junction box?

The flame override switch connects to wires marked 3 and 4, which are blue wires, along with the green ground wire.


What color wires are used for the heater wall switch and thermostat inside the DIMPLEX BFSL33 junction box?

The heater wall switch and thermostat connections use wires marked 1 and 2, which are red wires, along with the green ground wire.


What color wires are used for the main power connection inside the DIMPLEX BFSL33 junction box?

The main power incoming connections use wires marked L1 (black), L2 (red), N (white), and G (green).


What amp draw does the DIMPLEX BFSL33 require under different voltage configurations?

No Heat (120 Volt): 0.07A

120 Volt: 10.2A

208 Volt: 8.7A

240 Volt: 10.1A


What power wattage outputs are supported across the operating voltages on the DIMPLEX BFSL33?

No heat / flame only: 8 Watts

120 Volt operation: 1223 Watts

208 Volt operation: 1823 Watts

240 Volt operation: 2423 Watts


What remote control stage does the DIMPLEX BFSL33 feature?

The DIMPLEX BFSL33 features a 3 Stage remote control system.


Can the DIMPLEX BFSL33 be installed in a corner framing configuration?

Yes, the DIMPLEX BFSL33 can be installed in a rough-in corner framing with dimensions of 29 1/4 inches (744 mm) along the adjacent walls and a 41 inch (1041 mm) face opening.


How many mounting flanges are provided on the DIMPLEX BFSL33?

Four mounting flanges are provided, with two located on each side of the fireplace unit.


CLICK HERE TO DOWNLOAD DIMPLEX BFSL33 (02) PDF DOCUMENT


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.