What is the DEVIREG PLUG-IN 140F1134?

The DEVIREG PLUG-IN 140F1134 is an electronic thermostat to be installed in a socket outlet, used for controlling floor heating elements or other heating appliances. The thermostat is to be used only where heating is made by DRV CPH-plugs or DEVImat™ for wooden floors, laminated floors, etc. The thermostat has an NTC wire sensor to measure the temperature. The temperature is shown in a display and the temperature is set by means of the knob. The thermostat has a temperature range of +5 °C to +35 °C. An LED normally displays the temperature.


What are the technical specifications for the DEVIREG PLUG-IN 140F1134?

Operation voltage 220-240V~, 50-60 Hz
Standby power consumption Max 0.5 W
Resistive load Max 16 A / 3680 W @ 230 V
Inductive load Max 1 A, cos φ = 0.3
Sensing unit NTC 15 kΩ at 25 °C
Hysteresis +/- 0.2 °C
Ambient temperature 0 °C to +30 °C
Temperature range +5 °C to +35 °C (Default is 5 °C)
Pollution degree 2 (domestic use)
Type 1C
Protection class Class II – IP20
Dimensions (H/W/D) 141 x 70 x 78 mm
Weight 270 g

The product is in conformance with the EN/IEC Standard «Automatic electrical controls for household and similar use»:

  • EN/IEC 60730-1 (general)
  • EN/IEC 60730-2-9 (thermostat)

What are the safety instructions for installing the DEVIREG PLUG-IN 140F1134?

Make sure the supply to the thermostat is turned off before installation.

Please also observe the following:

Always connect the thermostat to a continuous power supply.

Never connect the thermostat to a supply voltage outside the marking.


How should I place and install the DEVIREG PLUG-IN 140F1134?

Please observe the following placement guidelines:

Place the thermostat on a wall that will be exposed to room air flow.

Follow the steps to mount the thermostat:

1. Open the front cover. Release the screw on the bottom.

2. Connect the wire sensor of the thermostat to the pipe which is placed in the floor. The sensor should be placed in the middle of the cable loops.

3. Connect the heating cable plug to the thermostat.

4. Put the cover on again.


How do I operate the DEVIREG PLUG-IN 140F1134?

Press the ON/OFF button for 1 sec to turn parameter setting on. Each press of ON/OFF will shift to the next setting parameter.

Press ON/OFF again for 5 sec to enter parameter setting mode. Press ON/OFF again to confirm your choice. The dual-diodes beside the symbols of thermostat and timer will be lit to show which is in operation.


What are the adjustable parameter settings for the DEVIREG PLUG-IN 140F1134?

No. Functions Range Default
01 Hysteresis 0.0°C – 5°C 0.2°C
02 Set temp. speed 0 – 5 0
03 Software version

How should I dispose of the DEVIREG PLUG-IN 140F1134?

The symbol with the crossed-out wheelie bin indicates that this product may not be disposed of as household waste.

It must be handed in at a collection point for the recycling of electrical and electronic equipment. By ensuring correct disposal of the product you will help prevent potential negative consequences for the environment and human health, that could otherwise be caused by inappropriate waste handling.

Dispose of the product through channels available for this purpose.

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

CLICK HERE TO DOWNLOAD DEVIREG PLUG-IN 140F1134 (01) PDF DOCUMENT


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.