FREE ENGLISH DATATRONIX DT-ATSC-QAM-8V2 (01) PDF DOCUMENT.
FREE ENGLISH DATATRONIX DT-ATSC-QAM-8V2 (01) PDF USER GUIDE.
FREE ENGLISH DATATRONIX DT-ATSC-QAM-8V2 (01) PDF USER MANUAL.
FREE ENGLISH DATATRONIX DT-ATSC-QAM-8V2 (01) PDF OWNER GUIDE.
FREE ENGLISH DATATRONIX DT-ATSC-QAM-8V2 (01) PDF OWNER MANUAL.
FREE ENGLISH DATATRONIX DT-ATSC-QAM-8V2 (01) PDF REFERENCE GUIDE.
FREE ENGLISH DATATRONIX DT-ATSC-QAM-8V2 (01) PDF INSTRUCTION GUIDE.
FREE ENGLISH DATATRONIX DT-ATSC-QAM-8V2 (01) PDF REFERENCE MANUAL.
FREE ENGLISH DATATRONIX DT-ATSC-QAM-8V2 (01) PDF INSTRUCTION MANUAL.
FREE ENGLISH DATATRONIX DT-ATSC-QAM-8V2 (01) PDF OPERATING INSTRUCTIONS.
CLICK HERE TO DOWNLOAD DATATRONIX DT-ATSC-QAM-8V2 (01) PDF DOCUMENT
If this is not the document you want for this product, click here to see if we have any other documents for this product.
How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.
What safety precautions should be followed when using the DATATRONIX DT-ATSC-QAM-8V2?
The presence of the uninsulated dangerous voltages symbol is to alert the installer and user to the presence of uninsulated dangerous voltages within the product’s enclosure that may be of sufficient magnitude to produce a risk of electric shock.
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS DEVICE TO RAIN OR MOISTURE. DO NOT OPEN THE UNIT. REFER SERVICING TO QUALIFIED PERSONNEL ONLY.
• DO NOT apply power to the unit until all connections have been made, all components have been installed and all wiring has been properly terminated.
• DO NOT terminate, change or uninstall any wiring without first disconnecting the unit’s power adapter from the device.
• This device is supplied with the appropriately rated power supply. The use of any other power supply could cause damage and invalidate the manufacturer’s warranty.
• DO NOT connect the power cord to the device if the power cord is damaged.
• DO NOT cut the power cord.
• DO NOT plug the power cord into an AC outlet until all cables and connections to the device have been properly connected.
• The device should be installed in an environment consistent with its operating temperature specifications. Placement next to heating devices and ducts is to be avoided as doing so may cause damage. The device should not be placed in areas of high humidity.
• DO NOT cover any of the device’s ventilation openings.
• DO NOT cover or obstruct the device’s fan or fan openings.
• If the device has been in a cold environment allow it to warm to room temperature for at least 2 hours before connecting to an AC outlet.
What is included in the package for the DATATRONIX DT-ATSC-QAM-8V2?
> One DT-ATSC-QAM-8V2
> One Power Cable
> One Installation / Configuration Manual
What should I do upon unpacking the DATATRONIX DT-ATSC-QAM-8V2?
Each unit is shipped from the factory tested. Ensure all items are removed from the container prior to discarding any packing material.
Thoroughly inspect the unit for shipping damage with particular attention to connectors and controls. If there is any sign of damage to the unit or damaged or loose connectors contact your distributor right away.
What are the key features of the DATATRONIX DT-ATSC-QAM-8V2?
✓ Accepts 8 RF inputs (ATSC-8VSB/QAM)
✓ Allows for Up to 64 Output Programs
✓ Allows User to “Cherry Pick” Desired Programs as Needed
✓ Supports STD/HRC/IRC Formats
✓ Supports Full Range of ATSC-8VSB/QAM Signals
✓ Offers 8 Fully Independent RF QAM Outputs
✓ Easy to Setup and Monitor with GUI
✓ Front Panel LED Indicators
✓ 3 VCN Modes Supported
✓ High Density 1RU Design
What is the system parsing and response time for the DATATRONIX DT-ATSC-QAM-8V2?
The initial System Parsing time will range from 4-6 minutes on average as the system identifies and populates the required parameters. As the user navigates the device’s menu note that a small delay may occur in populating the data on the screen as the system is constantly performing system parsing and system house-keeping functions.
What are the specifications of the DATATRONIX DT-ATSC-QAM-8V2?
Input
| RF Mode (ATSC-8VSB and QAM) | |
| Connector | 1 x F-Type, Female |
| Input Impedance | 75 ohm |
| Modulation | ATSC-8VSB ITU J.83 Annex B (64-QAM, 256-QAM) |
| Tuning Block Freq Range | 55 to 861MHz (Center) |
| Bandwidth | 6 MHz |
| Numbers of Tuner | 8 |
| Input Level | 6 MHz |
| Loop Through | |
| Connector | 1 x F-Type, Female, Passive |
Web Management
| GigE | |
| Connector | 1 x RJ45 |
| Standard | 100/1000Base-T Ethernet, Full / Half Duplex, Auto-Negotiation |
| HTTP | Embedded |
Emergency Alert System (EAS) (Optional)
| GigE | |
| Connector | 1 x RJ45 |
| Standard | 100 / 1000Base-T Ethernet, Full / Half Duplex, Auto-Negotiation |
| UDP / RTP | Supported (user-selectable) |
| Protocol | SCTE-18 Supported |
Output
| QAM | |
| Connector | 1x “F” Female |
| Modulation | 256-QAM / 64-QAM |
| Standard | J.83 Annex B |
| Frequency Range | 57 to 861 MHz (Under STD Mode)8 Independent RF Frequencies |
| Channels’ Bandwidth | 6 MHz |
| Output Level | 45 dBmV Typical |
| Output Impedance | 75 ohm |
| Level Adjustment | 0 to -20 dB |
| VCN | Auto (Major & Minor) Manual (Major & Minor) Manual (One Part) |
| Carrier Suppression | 55 dB |
| RF Output Return Loss | 10 dB Typical |
| Signal-to-Noise Ratio (SNR) | 42 dB Typical |
| MER | 41 dB Minimum, 44 dB Typical |
Alarms / Monitoring
| Local Monitoring | 8 x NIM Status LEDs / 1 x Power LED |
| Local Control | IP Reset Button |
| GUI Supported | Firefox, Chrome |
| Password Protected | GUI: Changeable |
Power
| Power Supply | 12VDC 5.4Amp. |
| Consumption | 23 W Typical |
| Input Voltage Range | 100 to 240 VAC |
Mechanical and Environmental
| Chassis (W x D x H) | 19.01 x 9.45 x 1.74″ (483 x 240 x 44.2 mm) |
| Weight | 7.9 lbs. |
| Operating Temperature | 32 to 122°F (0 to 50°C) |
| Storage and Transportation Temperature | 32 to 140°F (0 to 60°C) |
| Language | English |
**Specifications Subject to Change Without Notice.**
How do I perform the initial hardware installation for the DATATRONIX DT-ATSC-QAM-8V2?
1. Use properly installed terrestrial antennas. Verify for proper signal reception and signal levels.
2. Properly connect required outputs of terrestrial antennas/splitter feeds to the DT-ATSC-QAM-8V2.
3. Apply Power to the DT-ATSC-QAM-8V2.
4. Connect an Ethernet cable from Utility Port on the DT-ATSC-QAM-8V2 to a PC/MAC.
How do I connect to the GUI interface of the DATATRONIX DT-ATSC-QAM-8V2?
1. Connect an Ethernet Cable directly to the Utility Port on the rear panel of the device or connect the Ethernet cable to an Ethernet switch. Connect an Ethernet cable to Your PC/Laptop.
2. Modify Your PC/Laptop IPV4 address to 192.168.1.11.
3. Enter the Default IP Address for DT-ATSC-QAM-8V2 into Your Web Browser (Suggested browser: Firefox or Chrome).
The Factory Default IP is: 192.168.1.9.
How do I log in to the DATATRONIX DT-ATSC-QAM-8V2 GUI for system setup?
After connecting the device to the GUI interface:
1. Enter device’s IP address in web browser.
2. Login: Enter unit Name/Password.
The default login credentials are:
Name: admin / Password: Admin123
Note: To modify the system password, go to the [Administration Page] of the device.
What information is displayed on the Overview Page of the DATATRONIX DT-ATSC-QAM-8V2?
The [Overview Page] provides an overall system status of the DATATRONIX DT-ATSC-QAM-8V2 including: RF Input Type, Frequency, SNR, Signal Status, and Programs. The page displays a table with the following columns for each of the 8 RF inputs:
• RF Input
• Standard (e.g., ATSC, QAM)
• Frequency (MHz)
• Constellation (e.g., 8 VSB, 256 QAM)
• SNR (dB)
• Signal (visual strength indicator)
• Status (e.g., Lock)
• Programs (number of programs with a detail icon)
If you move your cursor to the “i” icon in the Programs column, you will see detailed information such as “2 In 2 Ready / 2 Out 2 Ready”.
What does the RF Output tab on the Overview page of the DATATRONIX DT-ATSC-QAM-8V2 show?
The RF Output tab within the Overview page shows the number of sub-streams/programs for each of the 8 RF outputs. It displays a series of pie charts, one for each RF output, with a corresponding legend that lists the sub-streams (e.g., 106-1, 106-2, etc.) and a category for “Unused” capacity.
What information is available on the Fan tab of the Overview page for the DATATRONIX DT-ATSC-QAM-8V2?
The Fan tab on the Overview page shows the fan status and system uptime. It displays the System UTC Time, the total Uptime in Hours, Minutes, and Seconds, and a table listing each fan’s speed in RPM and its operational status (e.g., OK).
How do I configure the inputs on the [Ingest Setup] page of the DATATRONIX DT-ATSC-QAM-8V2?
Use the [Ingest Setup] page to configure each input. Up to 8 individual ATSC or QAM inputs can be assigned.
1. Select the Ingest setup tab from the top menu.
2. Select the appropriate ingest input (1 thru 8). Enable as required by checking the box.
3. Select Standard: ATSC or QAM. For ATSC, select 8VSB. For QAM, select STD, HRC, or IRC.
4. Select Constellation: For QAM, select 64-QAM or 256-QAM as required.
5. Select Frequency (MHz) (Input):
• ATSC-8VSB: UHF (CH 14 – 69) VHF (CH 2-13)
• QAM: CH 2 – CH 135 (57 MHz to 861 MHz)
6. Click Save and Confirm to save all changes.
*****Note: Leaving any ingest setup page without saving the set parameters will cause the device to revert to the last saved settings.
How do I set up the output streams using the [Streaming Setup] page on the DATATRONIX DT-ATSC-QAM-8V2?
Use the [Streaming Setup] page to set the output SID, VCN Mode Type, VCN, Short Name, and other parameters.
1. Enable each stream/program as required by checking the check box on the left side of the table. To remove a stream/program, deselect/uncheck it.
2. Modify SID (Services Output ID). Note: If installing multiple DT-ATSC-QAM-8V2 units, make sure not to duplicate SID outputs. Entering a SID for one program will cause subsequent programs to be assigned consecutive numbers.
3. Enter Short Name [1-7 Characters].
4. Enter Long Name [1-16 Characters].
5. Select VCN Mode: Choose from VCN Mode 2-Part Auto, VCN Mode 2-Part Manual, or VCN Mode 1-Part Manual. Note: Only 1 VCN mode type can be selected.
6. Modify Source ID as required. Note: If installing multiple units, do not duplicate source ID outputs.
7. Select RF# from 1-8 to assign programs to the desired carrier. Note: Bitrate mapping may be required based on the Mbps of the streams/programs in the RF Out. You may need to move programs to allow for increased overhead.
8. Save and Confirm all parameters.
*****Note: Leaving any Streaming Setup page without saving the set parameters will cause the device to revert to the last saved settings.
What do the Streaming System Parameters on the DATATRONIX DT-ATSC-QAM-8V2 mean?
Input Parameters
| Input No. | Total Input Number Received by Tuner |
| PMT PID | Program Map Table PID |
| Video PID | Video Stream PID |
| Audio PID | Video Stream PID |
| TS ID | Input Transport Stream ID |
| SID | Service ID (Program ID) |
| Short Name | From Content Provider |
| Long Name | From Content Provider |
| Bit Rate | Input Bit Rate |
Output Parameters
| SID | Service ID – Definable |
| PMT PID | Program Map Table PID |
| Video PID | Video Stream PID |
| Audio PID | Audio Stream PID |
| Short Name | Definable [1-7 Characters] |
| Long Name | Definable [1-16 Characters] |
| VCN Mode | Selectable (Auto 2-Part, Manual 2-Part, Manual 1-Part.) |
| VCN | Definable (When Using Manual VCN Modes) |
| Source ID# | Definable |
How can I customize the view of the [Streaming Setup] page on the DATATRONIX DT-ATSC-QAM-8V2?
The [Streaming Setup] parameters page is easily customizable. To customize the parameters shown:
1. Select the “Select Columns” tool/button.
2. A pop-up window will appear titled “Select Columns”. Add or remove parameters as needed by selecting or deselecting the checkboxes under the Input Columns, Others, and Output Columns sections.
3. Close the window after selecting / deselecting parameters.
How do I configure the RF output channels on the [RF Output Setup] page of the DATATRONIX DT-ATSC-QAM-8V2?
Use the [RF Setup Page] to properly setup each RF output channel.
1. Enable / Disable RF output as required by checking the box for each RF output (1-8).
2. Enter TS_ID (Transport Stream ID) value.
3. Enter regional name as required.
4. Select RF type [Normal, Inverted, C.W.].
5. Select Channel type [STD, HRC, IRC].
6. Set CH/Freq. [CH 2 – CH 135 / Freq. 57MHz ~ 861MHz]. Note: The DT-ATSC-QAM-8V2 is frequency agile.
7. BW: factory set [6MHz].
8. Set attenuation [ 0 ~ -20dB, 1dB Steps].
9. Select constellation [64-QAM, 256-QAM].
10. Select interleaver – change as required. [Default: I=128, J=1].
11. Save and Confirm all changes.
Note 1: Bitrate Mbps shown allows the integrator to quickly review assigned stream bitrate allocated and Capacity.
Note 2: Bitrate mapping may be required based on the Mbps of the streams/programs in the RF Out.
Note 3: Use the [Streaming Setup Page] to move program(s) as needed to allow for increased overhead of required programs.
Note 4: Leaving any [RF Output Setup Page] without saving the set parameters will cause the device to revert to the last saved settings.
How do I configure the network settings for the DATATRONIX DT-ATSC-QAM-8V2?
1. Select the network setup tab to manage the IP address of the device.
2. Modify hostname as required.
3. Select DHCP or static IP. Uncheck the DHCP box to set a static IP.
4. For Static IP: select static IP and enter the desired static IP address for the device.
5. Enter Subnet Mask.
6. Enter Default Gateway.
7. Enter DNS Server 1 address.
8. Enter DNS Server 2 address (if required).
9. Click Save and Confirm to apply all changes.
What should I do if I forgot the IP address of my DATATRONIX DT-ATSC-QAM-8V2?
You can return to the default IP address (factory default) setting from the front panel by following the steps below:
1. Press the Reset button on the front panel. It is a small recessed button located to the right of the “Tuner Signal” LEDs.
2. Power on the unit.
3. Release the reset button once the power LED stops flashing and becomes static green.
4. The unit’s IP address will revert back to the default IP: 192.168.1.9.
5. The unit’s login data will revert back to the factory default: Name: admin / Password: Admin123.
Note: ONLY THE IP ADDRESS WILL REVERT BACK TO THE DEFAULT SETTING. NO CHANGES WILL BE MADE TO THE CONFIGURATION.
How do I set the location and description for the DATATRONIX DT-ATSC-QAM-8V2?
Use the [System Setup Page] to designate a location and description for the unit. Navigate to the “System Setup” tab, and under the “Description” sub-tab, enter the Location and Description text in the respective fields and click the “Apply” button.
How do I set the system time and NTP server on the DATATRONIX DT-ATSC-QAM-8V2?
Use the “Time” tab within the “System Setup” page to set the unit’s system time, time zone, and NTP Server.
1. Select the “Time” tab on the system setup page.
2. Select the time zone from the drop-down tool.
3. Enter NTP Server 1 / 2 addresses as required (e.g., 0.pool.ntp.org).
4. Select “Synchronize with PC’s Clock” as required to match the time with your computer.
5. Select “Apply” to apply all changes.
How do I reboot or reset the DATATRONIX DT-ATSC-QAM-8V2 to factory settings?
Navigate to the “Administration” page.
Reboot:
Use the Reboot button to reboot the device. No parameters will be changed.
Reset to Default:
Use the Reset to Default button to reset all parameters to original factory settings.
How do I back up and restore the configuration on the DATATRONIX DT-ATSC-QAM-8V2?
Backup
We highly recommend saving your device’s settings.
1. Select the “Administration” tab.
2. Select “Backup” from the menu. On the “Backup / Restore” page, click the BACKUP button.
3. A dialog box will appear. You can choose which data to backup from the following pages: Ingest setup / Streaming Setup / RF Out Setup / Network Setup / System Setup. Check the desired boxes.
4. Click “Download” to locate and name the file for future use.
Note: The backup can be imported to assist in setting up new or multiple devices onsite. Remember to Save and backup any and all changes.
Restore
1. Select the “Administration” tab.
2. Click “Browse…” to find the required configuration file to be imported.
3. Select “Upload” to import the selected file into the device.
*****Note: Do not power off the unit while importing.
How do I update the firmware on the DATATRONIX DT-ATSC-QAM-8V2?
Use the Firmware Upgrade section to import a new FW version.
1. Select the “Administration” tab.
2. Select the “Firmware Upgrade” tab.
3. Click “Browse…” to locate the required image file to be uploaded.
4. Select “Upload” to import the selected file into the device.
*******Note: Do not power off the unit while importing.
How do I change the administrator password on the DATATRONIX DT-ATSC-QAM-8V2?
Use the password section on the Administration page to change or modify the device’s password as desired.
1. Select the “Administration” tab.
2. Select the “Password” tab.
3. Follow the listed instructions for the new password. The new password must contain:
• 6~8 characters
• At least one digit
• At least one uppercase character
• At least one lowercase character
4. Enter the Old Password, New Password, and Confirm Password in the respective fields.
5. Click Save and Confirm to apply the new password.
CLICK HERE TO DOWNLOAD DATATRONIX DT-ATSC-QAM-8V2 (01) PDF DOCUMENT
