What are the safety instructions for operating the COPELAND CT760?

When operating the COPELAND CT760, please adhere to the following safety instructions:

• This manual is part of the product and should be kept near the instrument for easy and quick reference.

• The instrument shall not be used for purposes different from those described in the manual. It cannot be used as a safety device.

• In case of failure or faulty operation contact the local distributor with a detailed description of the fault.

• Strictly follow the safety instructions before opening the box.

• Check the application limits and the correct power supply voltage before proceeding.

• Do not expose to water or moisture: use the controller only within the operating limits avoiding sudden temperature changes with high atmospheric humidity to avoid condensation.

• Warning: disconnect the power supply and all other electrical connections before any kind of maintenance.

• Observe the maximum current value which can be applied to each relay (see Technical Data).

• Ensure that the wires for probes, loads and the power supply are separated and far enough from each other, without crossing or intertwining.


What are the electrical connections for the COPELAND CT760?

The electrical connections for the COPELAND CT760 are detailed in the table below:

PIN Label Description
1 Line Digital output 4: Common
2 Alarm/AUX Digital output 4: normally closed
3 NC Digital output 4: normally open
4 Not Used
5 Not Used
6 Not Used
7 N 100-240V power supply: Neutral
8 Line 100-240V power supply: Line;
9 Not Used
10 Not Used
11 Comp Digital output 5: Common
12 Comp Digital output 5: normally open
13 Def Digital output 2: Common
14 Def Digital output 2: normally open
15 Light Digital output 1: Common
16 Light Digital output 1: normally open
17 Fan Digital output 3: Common
18 Fan Digital output 3: normally open
19 Not Used
20 Not Used
21 Not Used
22 Not Used
23 Not Used
24 Pb4-In Analogue input 4 (temperature only)
25 Ground for analogue input 3 and 4
26 Pb3-In Analogue input 3 (temperature only)
27 Pb2-In Analogue input 2 (temperature only)
28 Ground for analogue input 1 and 2
29 Pb1-In Analogue input 1 (temperature only)
30 DI2-In Digital input 2 (free voltage)
31 Ground for digital input 1 and 2
32 DI1-In Digital input 1 (free voltage)
33 LAN – Digital output 1: normally open
34 LAN + High voltage power supply: Neutral
35 RS485 (GND) Ground terminal for RS485 serial port
36 RS485 (-) Negative terminal for RS485 (-) serial port
37 RS485 (+) Positive terminal for RS485 (+) serial port
38 Remote key (-) Negative terminal for Remote keyboard (-)
39 Remote key (+) Positive terminal for Remote keyboard (+)
40 Remote key (VNR) Supply for remote keyboard
41 AnOUT2 (-) Analog output 2 ground
42 AnOUT2 (+) Analog output 2 Signal (+)
43 AnOUT1 (-) Analog output 1 ground
44 AnOUT1 (+) Analog output 1 Signal (+)

What are the different screens on the COPELAND CT760 user interface?

The user interface of the COPELAND CT760 features several screens, each with a specific function:

SCREEN NAME DESCRIPTION
Home Show temperature value, measurement unit and active alarms only. It is the first screen after power on or after exit from other status.
Status Visualization This screen shows activated functions and regulation outputs (compressor, ventilators) overlapped with temperature and/or humidity value.
Virtual Keyboard This screen shows available functions. Activated function will blink when this screen is visualized.
Temperature Setpoint This screen enables the modification of the Temperature Set Point value.
Programming Mode This screen enables the modification of parameters: ALL, GrP or “X9” mode can be used.
Hotkey Management UPL = upload parameters from device to HOTKEY, doL = download parameters from HOTKEY to device.
Info Menu To scroll all I/O variables and status (probes, digital inputs, digital outputs, etc.).
Device Locked V-Swipe from Home screen to lock or unlock the device.

How do I use gestures to operate the COPELAND CT760?

The COPELAND CT760 can be operated using the following touch gestures:

GESTURE HOW-TO DESCRIPTION
ONE TAP Press a specific area of the screen with a finger for 1 sec. Switch ON / Switch OFF: when in Virtual Keyboard, use this to turn on/off a specific function. When in Programming mode, use this to select a parameter or a parameter value.
TAP and HOLD Press anyplace of the surface with a finger for more than 3 sec. Enter / Save: use this to enter programming mode or parameter menu and to save modifications. When in Virtual Keyboard, use this on the “ONOFF” to switch OFF and ON the device.
H-SWIPE Drag a finger across surface, from left to right or from right to left. Browse: use horizontal swipe (right to left or left to right) to browse through HOME, Virtual Keyboard and Info View. When in Programming menu: use horizontal swipe to browse through parameter menu.
V-SWIPE Drag a finger across surface, from top to bottom or from bottom to top (overlapping only one of the digits). Modify: use vertical swipe (from top to bottom or bottom to top) to change a parameter value.

How do I navigate the user interface on my COPELAND CT760?

You can navigate the COPELAND CT760 user interface using horizontal and vertical swipes (H-SWIPE, V-SWIPE) and taps.

Home Navigation:

• From the Home screen (showing temperature), an H-SWIPE will take you to the Status Visualization screen (‘SEE’).

• From the Status Visualization screen, another H-SWIPE moves to the Programming Mode screen (‘PrG’).

• From the Programming Mode screen, another H-SWIPE takes you to the Info Menu screen (‘inF’).

Set Point Temperature:

• From the Status Visualization screen (‘SEE’), a V-SWIPE down will display the current set point (e.g., ‘15.0’).

• Tap anywhere on the set point screen to enter modification mode.

• Use V-SWIPE to change the set point value.

• Tap ‘SET TO SAVE’ to confirm the new value.

Programming Menu:

• From the Programming Mode screen (‘PrG’), tap anywhere to enter the parameter groups menu (‘ALL’, ‘GrP’).

• H-SWIPE to navigate between parameter groups.

• Tap anywhere to enter a selected group (e.g., ‘ALL’).

• In the parameter list (e.g., ‘PAS’), H-SWIPE to browse through parameters.

• Tap to select a parameter, then use V-SWIPE to modify its value (e.g., ‘-24.0’).

• Tap ‘SET TO SAVE’ to confirm the change.


What are the technical specifications of the COPELAND CT760 keyboard?

Housing Self-extinguishing polycarbonate
Dimensions Front 80x38mm, case depth 26mm
Mounting device Panel, 71×29 mm panel cut-out; panel thickness 0.7 + 1.0mm; Insertion force: 40-60N
Degree of Protection EN 60529
Rear Housing: IP20
Front panel: IP54
Power Supply From XM750D power module, 3 wires, 0.5-2.5mm²
Display 3 digits, red LED, 20.4 mm high
Buzzer Internal, always present
Max distance between controller and keyboard 10m

What are the technical specifications of the COPELAND CT760 main controller?

Housing Self-extinguishing polycarbonate
Dimensions 140x110x48mm (w x h x d)
Mounting device DIN Rail
Degree of Protection EN 60529: IP20 (whole controller)
Power Supply 100 to 240VAC ±10%, 50/60Hz
Rated Power 100-240VAC 50/60 Hz: 10VA
Rated Impulse Voltage 2500V
Software Class A
Terminal blocks / Terminal Connections Low voltage signals: Screw or Disconnectable terminal block, wire section between 0.5 and 2.5 mm², max tightening force: 0.4 N/m
High Voltage signals: Plug-in or Screw terminal block, wire section between 1.5 and 2.5 mm², max tightening force: 0.5 N/m
Data Storing Real Time Clock: data maintenance up to 6 months with removable non-rechargeable lithium battery
Other parameters: internal flash
Type of Action 1.B
Pollution Degree 2, non-condensing humidity
Ambient Operating Temperature and Humidity IEC/EN: 0T60°C; 20-85 rH% (non-condensing humidity)
Shipping and storage temperature -40T85°C; 20-85 rH% (non-condensing humidity)
-20T70°C; 20-85 rH% (non-condensing humidity) – controller with RTC
Resistance to heat UL 94 V-0
Measurement range NTC, NTC_US: -40T110°C, resolution 0.1°C or 1°C (selectable)
PTC: -50T150°C, resolution 0.1°C or 1°C (selectable)
PT1000: -100T150°C, resolution 0.1°C or 1°C (selectable)
Accuracy NTC, PTC, PT1000: ±1% compared to the full scale
Inputs Up to 6 NTC, NTC_US, PTC or PT1000 (configurable); max distance 10m
Up to 2 voltage free contacts; max distance 10m
Purpose of control Operating control
Construction of control Built-in control, intended to be used in Class I or Class II equipment

What are the relay output ratings for the COPELAND CT760?

OUTPUT TERMINALS RATING UL 60730 RATING IEC/EN 60730 RATING IEC/EN 60335
oA5 11-12 Pilot duty C300, 30K cycles
Resistive load 1A, 230Vac, 30K cycles
Motor load 1FLA/6LRA, 230Vac, 30K cycles
1(1)A, 230Vac, 100K cycles 1(1)A, 230Vac, 100K cycles
oA3 17-18 Resistive load 5A, 230Vac, 30K cycles
Motor load 1/2HP, 230Vac, 30K cycles
Pilot duty B300, 6K cycles
5A, 230Vac, 60K cycles 5A, 230Vac, 100K cycles
oA4 (NO) 1-2 Resistive load 8A, 230Vac, 30K cycles
Motor load 1/2HP, 230Vac, 30K cycles
Pilot duty B300, 6K cycles
8A, 230Vac, 60K cycles
2(2)A, 250Vac, 100K cycles
2(2)A, 250Vac, 100K cycles
oA4 (NC) 1-3 Resistive load 3A, 230Vac, 30K cycles
Pilot duty C300, 6K cycles
3A, 230Vac, 30K cycles 3A, 230Vac, 30K cycles
oA2 13-14 Resistive load 10A, 230Vac, 100K cycles
Motor Load 10FLA/60LRA, 230Vac, 30K cycles
Pilot Duty B300, 30K cycles
10(4)A, 230Vac, 100K cycles 10(4)A, 230Vac, 100K cycles
oA1 (standard relay) 15-16 Resistive load 8A, 230Vac, 100K cycles
Motor Load 8FLA/48LRA, 230Vac, 30K cycles
Pilot Duty B300, 30K cycles
8(4)A, 230Vac, 100K cycles 8(4)A, 230Vac, 100K cycles
oA1 (inrush relay) 15-16 Resistive load 8A, 230Vac, 50K cycles
Motor Load 8FLA/48LRA, 230Vac, 30K cycles
Pilot Duty B300, 30K cycles
8(2)A, 230Vac, 100K cycles 8(2)A, 230Vac, 100K cycles

What are the analogue output specifications for the COPELAND CT760?

The COPELAND CT760 features two analogue outputs with the following specifications:

Analogue Output 1 (1Ao / AnOUT1):

• Can be configured as 4-20mA, 0-10V, or PWM.

• Frequency output: Supply voltage 12Vdc; Max supply current=5mA; duty cycle 50%; 0 to 166 Hz. Accuracy: ±1Hz compared to the full scale.

• Current output: 4-20mA; Max load 100 ohm.

• Voltage output: 0-10Vdc; Max supply current=5mA; Min load 2 K ohm.

• Accuracy: ±2% compared to the full scale.

Analogue Output 2 (2Ao / AnOUT2):

• Can be configured as 0-10V or PWM.

• Frequency output: Supply voltage 12Vdc; Max supply current=5mA; duty cycle 50%; 0 to 166 Hz. Accuracy: ±1Hz compared to the full scale.

• Voltage output: 0-10Vdc; Max supply current=5mA; Min load 2 K ohm.

• Accuracy: ±2% compared to the full scale.

Hot Key I/O Port:

The output voltage is 5 VDC. DO NOT CONNECT ANY EXTERNAL POWER SUPPLY.

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

CLICK HERE TO DOWNLOAD COPELAND CT760 (01) PDF DOCUMENT


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.