What are the important safety instructions for using the COLEMAN S100205 spa?
When using this electrical equipment, basic safety precautions should always be followed:
• READ AND FOLLOW ALL INSTRUCTIONS.
• To reduce the risk of injury, do not permit children to use this product unless they are closely supervised at all times.
• DANGER – Risk of Accidental Drowning. Extreme caution must be exercised to prevent unauthorized access by children. To avoid accidents, ensure that children cannot use this spa unless they are supervised at all times.
• DANGER – Risk of Injury. The suction fittings in this spa are sized to match the specific water flow created by the pump. Should the need arise to replace the suction fittings or the pump, be sure that the flow rates are compatible. Never operate the spa if suction fittings are broken or missing. Never replace a suction fitting with one rated less than the flow rate marked on the original suction fitting.
• The use of alcohol, drugs, or medication before or during spa use may lead to unconsciousness with the possibility of drowning.
• Obese persons and persons with a history of heart disease, low or high blood pressure, circulatory system problems, or diabetes should consult a physician before using a spa.
• Persons using medication should consult a physician before using a spa since some medication may induce drowsiness while other medication may affect heart rate, blood pressure, and circulation.
• WARNING: To avoid electric shock, do not use the spa during storms in case of thundering or lighting. In case of rain always keep plug dry, plug in with wet plug is definitely forbidden.
• WARNING: Water attracts children; Always attach a spa cover after each use.
• CAUTION: Do not use the spa alone.
• CAUTION: Always enter and exit the spa slowly and cautiously. Wet surfaces are slippery.
• CAUTION: To avoid damage to the pump, the spa must never be operated unless the spa is filled with water.
• CAUTION: Immediately leave spa if the user feels uncomfortable or sleepy.
How can I reduce the risk of electric shock with the COLEMAN S100205 spa?
Follow these guidelines to reduce the risk of electric shock:
• DANGER – Risk of Electric Shock. Install at least 5 feet (1.5 m) from all metal surfaces. As an alternative, a spa may be installed within 5 feet of metal surfaces if each metal surface is permanently connected by a minimum 8 AWG (8.37 mm²) solid copper conductor to the wire connector on the terminal box that is provided for this purpose.
• DANGER – Risk of Electric Shock. Do not permit any electric appliance, such as a light, telephone, radio, or television, within 5 feet (1.5 m) of a spa.
• DANGER – Risk of injury. Replace damaged cord immediately. Do not bury cord. Connect to a grounded, grounding type receptacle only.
• This product is provided with a ground-fault circuit-interrupter (GFCI) integrated with the power plug. The GFCI must be tested before each use. With the product operating, push the test button on the GFCI and the product should not operate. Push the reset button on the GFCI and the product should now operate normally. When the product fails to operate in this manner, there is a ground current flowing indicating the possibility of an electrical shock. Disconnect the power until the fault has been identified and corrected.
What are the warnings regarding water temperature for the COLEMAN S100205 spa?
To reduce the risk of injury:
a) The water in a spa should never exceed 104°F (40°C). Water temperatures between 100°F (38°C) and 104°F (40°C) are considered safe for a healthy adult. Lower water temperatures are recommended for young children and when spa use exceeds 10 minutes.
b) Since excessive water temperatures have a high potential for causing fetal damage during the early months of pregnancy, pregnant or possibly pregnant women should limit spa water temperatures to 100°F (38°C).
c) Before entering a spa, the user should measure the water temperature with an accurate thermometer since the tolerance of water temperature-regulating devices varies.
d) WARNING: TO REDUCE THE RISK OF INJURY: Never add water that is higher than 104°F (40°C) into the spa.
What is hyperthermia and how does it relate to using the COLEMAN S100205 spa?
Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature of 98.6°F (37°C). The symptoms of hyperthermia include an increase in the internal temperature of the body, dizziness, lethargy, drowsiness, and fainting.
The effects of hyperthermia include:
• Failure to perceive heat
• Failure to recognize the need to exit spa or hot tub
• Unawareness of impending hazard
• Fetal damage in pregnant women
• Physical inability to exit the spa or hot tub
• Unconsciousness resulting in the danger of drowning
WARNING: The use of alcohol, drugs, or medication can greatly increase the risk of fatal hyperthermia.
How do I assemble and affix the provided warning label for the COLEMAN S100205 spa?
The warning label must be posted near your spa in a readable position during use.
1. Take out the warning label from the accessory kit.
2. Carefully peel the warning label.
3. Affix the warning label.
The label contains the following warnings:
REDUCE THE RISK OF ELECTROCUTION
1. NEVER PLACE AN ELECTRIC APPLIANCE WITHIN 5 FEET OF SPA.
REDUCE THE RISK OF CHILD DROWNING
1. SUPERVISE CHILDREN AT ALL TIMES.
2. ATTACH SPA COVER AFTER EACH USE.
REDUCE THE RISK OF OVERHEATING
1. CHECK WITH A DOCTOR BEFORE USE IF PREGNANT, DIABETIC, IN POOR HEALTH, OR UNDER MEDICAL CARE.
2. EXIT IMMEDIATELY IF UNCOMFORTABLE, DIZZY, OR SLEEPY. SPA HEAT CAN CAUSE HYPERTHERMIA AND UNCONSCIOUSNESS.
3. SPA HEAT IN CONJUNCTION WITH ALCOHOL, DRUGS, OR MEDICATION CAN CAUSE UNCONSCIOUSNESS.
WHEN PREGNANT, SOAKING IN HOT WATER FOR LONG PERIODS CAN HARM YOUR FETUS. MEASURE WATER TEMPERATURE BEFORE ENTERING.
1. DO NOT ENTER SPA IF WATER IS HOTTER THAN 100°F(38°C)
2. DO NOT STAY IN SPA FOR LONGER THAN 10 MINUTES.
How do I choose the correct location for my COLEMAN S100205 spa?
The surface chosen to install the spa must respect the following technical characteristics:
• Because of the combined weight of the water inside the spa and the users, it is extremely important that the surface chosen to install the spa is capable of uniformly supporting the total weight for the entire time the spa is installed.
• An adequate drainage system has to be provided to deal with overflow water for both indoor and outdoor installations.
• The surface must be flat and smooth. If the surface is inclined or uneven, it can create an unbalanced loading on the structure of the spa, which can damage the welding point.
• The selected surface must be clear of any type of object. Any object under the spa could damage or perforate the bottom of the spa.
• The selected location must not have overhead power lines or trees and should not contain underground utility pipes, lines, or cables.
• The position must be far from the house entrance. Do not position any equipment or other furniture around the spa.
• Do not install the spa on carpet or other porous floor materials (e.g., untreated cork, timber) that promote moisture and bacteria.
Suggested set-up surfaces: grass, ground, concrete, and all other surfaces that respect the above conditions.
Not suggested surfaces: mud, sand, gravel, deck, balcony, driveway, platform, soft/loose soil, or other surfaces that do not meet the above conditions.
What are the special requirements for installing the COLEMAN S100205 spa indoors?
Be aware of these special requirements if you install the spa indoors:
• Humidity is a natural side effect of the installation. Determine the effects of airborne moisture on exposed wood, paper, etc., in the proposed location. To minimize these effects, it is strongly recommended to provide plenty of ventilation to the selected area. Consult an expert to determine if more ventilation is needed.
• Keep suitable air treatment (ventilation and dehumidification) in the indoor location regularly to preserve the bathers’ safety and comfort.
• Empty the spa before removing it from the indoor location or building.
What are the special requirements for installing the COLEMAN S100205 spa outdoors?
For outdoor installation, follow these requirements:
• The selected surface must be clear of aggressive plants and weed species that could grow through the liner and create leakage.
• The grass or other vegetation that may cause odor or slime to develop must be eliminated from the set-up location.
• Do not leave the spa’s surface exposed to direct sunlight for long periods. It is recommended to protect the spa from direct sunlight exposure with a cover when not in use.
• Consult your local professional installers for environmental conditions, such as groundwater and risk of frost.
How do I test the GFCI plug before using my COLEMAN S100205 spa?
The GFCI plug must be tested before each use to avoid risk of electric shock. Do not use the pump if this test fails.
1. Insert the plug into a power outlet. Make sure the current rate of the power outlet is suitable for the pump.
2. With the product operating, push the test button on the GFCI. The product should stop operating.
3. Push the reset button on the GFCI. The product should now operate normally.
If the product fails to operate in this manner, there is a ground current flowing, indicating the possibility of an electrical shock. Disconnect the power until the fault has been identified and corrected.
How do I operate the control panel on my COLEMAN S100205 spa?
ON/OFF BUTTON: After activating the GFCI, press and hold the button for 2 seconds. The button turns green and the control panel is activated. Press and hold for 2 seconds to turn off all currently activated functions.
LOCK/UNLOCK BUTTON: The pump has a 5-minute auto-lock. To lock or unlock the pump, press the lock/unlock button for 2 seconds.
HEAT BUTTON: Press this button to activate the heating system. When the light is red, the heating system is activated. When the light is green, the water has reached the set temperature. If the heating system is activated, the filtration system will automatically start.
MASSAGE SYSTEM BUTTON: Press this button to activate the massage system, which has a 30-minute auto-shutoff feature. The light of the button becomes red when activated. Do not run the massage system when the cover is attached. For spas equipped with Wi-Fi, this button also controls the 2-Level Massage Regulation: Push once for full power massage (display shows L1), push again for lower power massage (display shows L2), and a third time to shut it off.
WATER FILTER BUTTON: This button turns the filter pump on and off. The button turns red when activated.
TEMPERATURE ADJUSTMENT BUTTONS: Pressing the up or down arrow buttons causes the display to flash the set temperature for 3 seconds. While it is flashing, you can adjust the temperature. The temperature adjustment ranges from 20°C (68°F) to 40°C (104°F).
CELSIUS/FAHRENHEIT TOGGLE: This allows the temperature display to be switched between Celsius and Fahrenheit.
POWER-SAVING TIMER BUTTON: This function is designed to help avoid wasting power by setting the time and duration of the heating cycle for the spa. See the specific instructions for activating this feature.
How do I use the Power-Saving Timer function on the COLEMAN S100205 spa?
Follow these steps to activate the POWER-SAVING function:
1. Press the timer button and the LED starts to flash.
2. Press the up or down arrow button to adjust the heating duration (from 1-999 hours).
3. Press the timer button again to confirm the heating duration.
4. After setting the heating duration, the LED starts to flash. Press the up or down arrow button to set the waiting time (from 0-999 hours). This defines the hours before the heating function activates. If set to 0, the heating system activates immediately.
5. Press the timer button again or touch nothing for 10 seconds to confirm the setting. The LED will light steadily, and the countdown to heater activation will begin. The screen will flash the current temperature and time alternately.
To modify the timer settings, press the timer button and use the arrow buttons to adjust.
To cancel the setting, press the timer button for 2 seconds.
NOTE: The Power-Saving function is not an automatic function. After one complete cycle (waiting time plus heating), the function must be set again.
How do I use the COLEMAN S100205 spa during the winter?
If you are setting up the spa in winter, it is important to follow these suggestions to prevent damage:
• If the outdoor temperature is below 10°C (50°F), keep the package indoors where the temperature is above 15°C (59°F) to make the spa liner more flexible and easier to set up.
• Open the package and inflate the spa liner in a room where the temperature is above 15°C (59°F).
• Position the spa liner outdoors, then connect the spa heater and fill with water. The water temperature used for filling must be above 6°C (42.8°F), otherwise, the E03 alarm will appear.
• You can keep the spa on during winter when the temperature is lower than 6°C (42.8°F). The Freeze Shield™ system automatically keeps the water temperature between 6°C (42.8°F) and 10°C (50°F) to prevent the water from freezing.
• If the water temperature is below 6°C (42.8°F), the spa heater must always be on. In this mode, the Freeze Shield™ system will work to prevent damage.
• If alarms appear on the display, the Freeze Shield™ system isn’t working. Be sure to check the status of your spa if the outdoor temperature is below 6°C (42.8°F).
• Do not use the spa when the ambient temperature reaches -10°C (14°F).
• Be sure to cover the spa with the spa cover whenever the heating function is activated. Leaving the spa uncovered will increase the heating duration required.
What is the approximate heating time for the COLEMAN S100205 spa?
To reach 40°C (104°F), the heating duration required is based on the starting water temperature and ambient temperature. The data below is for reference. To display the current water temperature, run the filter system for at least a minute.
| Ambient Temperature | Water Temperature | Set Temperature | Heating Duration |
|---|---|---|---|
| 10°C (50°F) | 10°C (50°F) | 40°C (104°F) | 23-40h |
| 15°C (59°F) | 15°C (59°F) | 40°C (104°F) | 18-36h |
| 20°C (68°F) | 20°C (68°F) | 40°C (104°F) | 13-29h |
| 25°C (77°F) | 25°C (77°F) | 40°C (104°F) | 9-20h |
| 30°C (86°F) | 30°C (86°F) | 40°C (104°F) | 7-15h |
What are the power specifications for the COLEMAN S100205 spa heater?
| SPA HEATER SPECIFICATION | |||
|---|---|---|---|
| Power Rate | Massage Tube Blower | Heat Element | Water Pump |
| 110-120V AC, 60Hz, Single Phase 12A at 20°C | 6.5A | 11.3A at 20°C | 0.7A |
How do I maintain the COLEMAN S100205 spa?
CAUTION: You must ensure the pump is unplugged before beginning spa maintenance to avoid risk of injury or death.
LINER: It is normal for the spa liner to appear as if it is losing air due to changes in ambient temperature affecting internal air pressure. When detaching the pump from the liner, block the air pipe by screwing on the cap and installing the stoppers on the debris screens to avoid water coming out.
COVER: The cover should be cleaned inside and outside periodically, using a gentle detergent for the PVC material.
FILTER CARTRIDGE: To optimize filtration performance, check and clean your filter cartridge every day. It is recommended to change your filter cartridge every week or replace it if it remains soiled and discolored after washing.
WATER: Keeping spa water clean and chemically balanced is necessary. Simply cleaning the filter is not enough. Use pool chemicals and chlorine or bromine tablets with a chemical dispenser. Water quality is related to frequency of use, number of users, and overall maintenance. It is recommended to change the water completely every 3 days if no chemical treatment is being performed. When emptying the spa, observe all regulations and instructions for draining water.
What are the recommended chemical levels for the water in the COLEMAN S100205 spa?
After performing chemical maintenance and before using the spa, use a test kit (not included) to test the water chemistry. We recommend maintaining your water chemical balance as follows:
| pH | Total Alkalinity | Free Chlorine |
|---|---|---|
| 7.4-7.6 | 80-120ppm | 2-4ppm |
Note: Spa damage resulting from misuse of chemicals and mismanagement of spa water is not covered by the warranty. Over usage of chemicals will discolor the printing and all points of the spa material.
How do I disassemble and store my COLEMAN S100205 spa?
DRAINING: To drain the spa, follow the drawings inside the manual.
DRYING: After draining, ensure the spa pump, liner chamber, massage chain, and inflatable cover are completely dry to extend the life of the spa and avoid mildew.
CLEANING: Detergent residues and dissolved solids may build up on the spa walls. Use soap and water to clean the walls and rinse thoroughly. Do not use hard brushes or abrasive cleaners.
DEFLATING (For Inflatable Spas): The spa is equipped with a deflation function. Follow the drawings in the manual to deflate the spa.
REPAIRING:
• For PVC Material: Clean the area to be repaired. Peel the provided PVC repair patch, press it over the area, and wait 30 seconds before inflation.
• For Duraplus™ PVC Material: Clean and dry the area. Cut the provided PVC patch to size. Use glue (not included) to coat one side of the patch evenly. Wait 30 seconds, then place the patch with glue over the damaged area. Smooth out air bubbles and press firmly for two minutes. Wait 30 minutes before inflation.
STORAGE: Remove all accessories and ensure all parts are completely clean and dry. Fold the spa liner only if the environment temperature is above 10°C (50°F). Store the spa in a dry place with a moderate temperature between 10°C (50°F) and 38°C (100°F). It is strongly recommended to position the spa liner and inflatable cover inside a carton box for better protection during winter months.
How do I troubleshoot common problems with the COLEMAN S100205 spa?
| Problem | Probable Causes | Solutions |
|---|---|---|
| Pump does not operate | – Power failure – Power circuits is broken |
– Check power source. |
| Pump does not heat properly with lid | – Temperature set too low – Dirty filter cartridge – Spa is not covered with lid – Heating element failed |
– Set spa to a higher temperature. – Clean/replace the filter cartridge. – Attach the cover. |
| Massage System does not work | – Air pump is overheating – The massage stops automatically after 30 minutes – Air pump is broken |
– Unplug the pump and wait two hours until the pump has cooled. Insert the plug and press the Massage System Button. – Press the Massage System Button to reactivate. |
| Pump adapters are not level with the spa adapters | – One characteristic of material is that it changes shape, which is normal. | – Elevate the pump with wood or another type of insulated material to bring the pump’s adapters level with the spa’s adapters. |
| Spa pool air leakage | – Spa is torn or punctured – Air valve is loose |
– Use provided repair patch. – Using soapy water, cover the air-valve to check if air is leaking. If so, fasten the air-valve by turning the valve clockwise. For Fortifiber SPA, deflate the spa, hold the backside of the air valve from the inner side of the spa wall and turn the wrench clockwise. |
| Water is not clean | – Insufficient filtering time – Dirty filter cartridge – Improper water maintenance |
– Increase filtration time. – Clean/replace the filter cartridge. – Refer to the chemical manufacturer’s instructions. |
How do I troubleshoot Wi-Fi connection issues with my COLEMAN S100205 spa?
| Probable Cause | Solution |
|---|---|
| The pump has been connected to the wrong band. | If the router is dual-band and not connecting to a 2.4GHz network, switch to another band of the same router (2.4GHz) and try to pair again. 5GHz networks are not supported. |
| The spa pump location is too far from the router. | Check with your cell phone to see if there is full Wi-Fi signal. If the signal strength is too low, check where the signal is full and place the spa in that position. |
| Set up with the wrong network name. | Start the connection procedures again and be sure that the network name is typed correctly. |
| The Wi-Fi password used during the connection is wrong. | Start the connection procedures again and be sure that the password is correct. |
| The strength of the Wi-Fi signal is not stable. | 1. Check that the router works correctly. 2. Go near the spa and check the signal on your phone. If the signal strength is not stable, check the condition of your router. If the signal strength is full, repeat the operation to connect the spa to the network. |
| There is an appliance near the spa pump or the router that creates signal interference. | The Wi-Fi connectivity can be interrupted by electromagnetic or other interferences. Keep the appliance away from other electronic devices that may cause interferences. |
| Your phone will not connect to the Wi-Fi network during the registration. | Check if the mobile device is in airplane mode. Make sure to have the airplane mode deactivated when connecting to the Wi-Fi network. |
What do the Wi-Fi LED status lights on my COLEMAN S100205 spa mean?
| Wi-Fi LED Status | Meaning | Action |
|---|---|---|
| Indicator light flashes slowly | Waiting to connect to the router | The pump is ready to connect to your phone. |
| Indicator light is on | Connected to the router | The pump is already connected to your phone. |
| Indicator light flashes quickly | Lost Wi-Fi signal | Check the status of your router. The spa lost the Wi-Fi signal. |
| Indicator light is off | Light damaged / Wi-Fi module has problem | Contact support for more information. |
What do the error codes on my COLEMAN S100205 spa mean?
| Error Code | Cause | Reason(s) | Solution(s) |
|---|---|---|---|
| 8.8.8 (flashing three circles) | The water flow sensors work without pressing the filter or heat button. | 1. The water flow sensor flags didn’t fall back into the correct position. 2. The water flow sensors are broken. |
1. Unplug the plug gently, strike the side of the pump but not violently, and plug it back in. |
| 8.8.8 (flashing GCF) | After starting or during the functions of filtering or/and heating, the water flow sensors do not detect water flow. | 1. You forgot to remove the 2 stopper caps. 2. Filter cartridges are dirty. 3. Water pump is broken or water flow sensors are broken. 4. Filter blockage, bent pipes, or blocked debris screens. |
1. Remove the 2 stopper caps before heating. 2. Remove the filter set, clean or change the filter cartridges. 3. Check if water flows out the outlet pipe. If not, the pump may be broken. 4. Clean the filter and check for damage. Check pipes for bending. Clean debris screens. |
| 8.8.8 (flashing three vertical lines) | The pump’s thermometer reads the water temperature below 40°F (4°C). | 1. The water temperature is lower than 40°F (4°C). 2. The pump’s thermometer is broken. |
1. The spa is not designed to operate with water temperatures lower than 40°F (4°C). Unplug the pump and only re-start when the water temperature reaches 43°F (6°C). |
| 8.8.8 (flashing sun icon) | The pump’s thermometer reads the water temperature over 119°F (48°C). | 1. Water temperature is over 119°F (48°C). 2. High ambient temperature or direct sunlight. 3. The pump’s thermometer is broken. |
1. Unplug the pump and only re-start when the water temperature reaches 100°F (38°C) or lower. 2. Disconnect the plug, detach the pump, and drain the spa. After 15 minutes, reattach and restart. Consider moving the spa to a location without direct sunlight. |
| 8.8.8 (flashing plug icon) | The pump’s thermometer connection has issues. | The connection between the temperature sensor and the PCB may have an issue. | 1. Unplug the spa, wait 5 minutes, and then plug it back in while switching the pump on. |
| 888 | The pump’s thermometer reads the water temperature over 116.6°F (47°C). | 1. Water temperature is over 116.6°F (47°C). 2. High ambient temperature or direct sunlight. 3. The pump’s thermometer is broken. |
1. Unplug the pump and only re-start when the water temperature reaches 100°F (38°C) or lower. 2. Disconnect the plug, detach the pump, and drain the spa. After 15 minutes, reattach and restart. Consider moving the spa to a location without direct sunlight. |
| 8.8.8 (flashing Wi-Fi icon) | Wi-Fi module connection failed. | Wi-Fi module is damaged. | NOTE: Press any button to remove alarm and continue to use the spa. |
| 8.8.8 (flashing two wavy lines and plug) | Detected electric from ground wire. | 1. The pump has detected electric from a ground wire. 2. The pump has a problem. |
1. Call an electrician immediately to understand if power is flowing inside the grounding connection. If the problem continues, to use your spa safely, we strongly recommend connecting the spa plug to a socket with independent grounding. |
| 8.8.8 (flashing ground pin icon) | Ground connection failed. | 1. The ground bonding of your home has a problem. 2. The pump has a problem. |
1. Connect the spa pump to a new socket or call an electrician to check the wall socket. If the problem continues, we suggest creating an independent grounding connection to the wall socket. |
How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.
CLICK HERE TO DOWNLOAD COLEMAN S100205 (01) PDF DOCUMENT