CHIEF CMA395 (01) PDF MANUAL


Post questions, comments, reviews or page errors in the comment box below.

Your File is Ready … Download PDF

CLICK HERE TO DOWNLOAD CHIEF CMA395 (01) PDF MANUAL


PDF Content Summary: INSTALLATION INSTRUCTIONS

Instrucciones de instalación Installationsanleitung Instruções de Instalação Istruzioni di installazione Installatie-instructies Instructions d´installation Angled Ceiling Adapter Spanish Product Description German Product Description Portuguese Product Description Italian Product Description Dutch Product Description French Product Description CMA395

CMA395 Installation Instructions

DISCLAIMER Milestone AV Technologies and its affiliated corporations and subsidiaries (collectively "Milestone"), intend to make this manual accurate and complete. However, Milestone makes no claim that the information contained herein covers all details, conditions or variations, nor does it provide for every possible contingency in connection with the installation or use of this product. The information contained in this document is subject to change without notice or obligation of any kind. Milestone makes no representation of warranty, expressed or implied, regarding the information contained herein. Milestone assumes no responsibility for accuracy, completeness or sufficiency of the information contained in this document. Chief® is a registered trademark of Milestone AV Technologies. All rights reserved. DEFINITIONS WARNING: A WARNING alerts you to the possibility of serious injury or death if you do not follow the instructions. CAUTION: A CAUTION alerts you to the possibility of damage or destruction of equipment if you do not follow the corresponding instructions. MOUNTING SYSTEM: A MOUNTING SYSTEM is the primary product designed by Chief® to mount the projector or display. ACCESSORY: An ACCESSORY is any product designed by Chief® to complement the primary mounting system either by mounting any supporting components or enhancing the mounting capabilities of the primary mounting system. COMPONENT: A COMPONENT is any secondary product to be mounted to an accessory, i.e. speakers, CPU’s, cameras, tablets, additional displays. IMPORTANT SAFETY INSTRUCTIONS! WARNING: Failure to read, thoroughly understand, and follow all instructions can result in serious personal injury, damage to equipment, or voiding of factory warranty! It is the installer’s responsibility to make sure all mounting systems/ accessories are properly assembled and installed using the instructions provided. WARNING: Failure to provide adequate structural strength for this accessory can result in serious personal injury or damage to equipment! It is the installer’s responsibility to make sure the structure to which this accessory is attached can support five times the combined weight of all equipment. Reinforce the structure as required before installing the accessory. WARNING: Exceeding the weight capacity can result in serious personal injury or damage to equipment! It is the installer’s responsibility to make sure the maximum weight installed on the ceiling plate does not exceed 500 lbs (226.8 kg). • The weight capacity of the CMA395 may be LIMITED to the lowest weight capacity of any other mounting system or accessory located between the CMA395 and the projector/display. WARNING: Use this accessory only for its intended use as described in these instructions. Do not use attachments not recommended by the manufacturer. WARNING: Never operate this accessory if it is damaged. Return the mounting system to a service center for examination and repair. WARNING: Do not use this product outdoors. IMPORTANT ! : The CMA395 must be attached to ceiling using two 3/8 x 2 1/2" lag bolts and 3/8" washers (not included). NOTE: The CMA395 is designed to be mounted to 2" x 4" or larger wood stud joists. By using any length of 1-1/2" NPT following ANSI/ASME B1.20.1 (Schedule 40, 0.154" minimum thickness aluminum - ASTM B221) threaded extension column with both ends threaded (not included), the height capabilities may be extended as needed. NOTE: The CMA395 may be used with the UL Listed CMS Extension Column series; LCM2X2U, LCM2X2UP, LCM3X2U, LCM3X2UP and LCM3X3U ceiling mounted video walls; and the UL Listed LCM1U, LCM1UP, LCM2X1U, LCM2X1UP, LCM3X1U, LCM3X1UP, LCM5X1U, MCM1U, XCM1U, XCM7000, LCB1U, LCB1UP, LCB1X2U, LCB2X1U, LCB2X1UP, MCB1U, MCB1X2U, XCB1U, XCB7000, FCA3U and FCA4U (not included). NOTE: The LCM2X2U, LCM2X2UP, LCM3X1U, LCM3X1UP, LCM3X2U, LCM3X2UP, and LCM3X3U require 2 CMA395 ceiling plates (not included). The LCM5X1U requires 3 CMA395 ceiling plates (not included).

2 Installation Instructions CMA395

DIMENSIONS 1 1/2" NPT THREADS 5/16 - 18 UNC THREADS 112.713 4.44 MAX HEIGHT 41.275 1.63 .44 100.00° 95.00° 90.00°

TOOLS / PARTS FOR INSTALLATION 5/32" (Included) 3/4" 9/16" A (1) [CMA395 assembly] B (1) 5/32" C (1) 5/16-18 x 3/8"

3 CMA395 Installation Instructions

ASSEMBLY AND INSTALLATION NOTE: The CMA395 ceiling plate is designed for ease of installation with any height of ceiling with 2" x 4" or larger wood joists. By using any length of standard NPT 1 1/2" NPT following ANSI/ASME B1.20.1 (Schedule 40, 0.154" minimum thickness aluminum - ASTM B221) threaded extension column with both ends threaded (not included), the height capabilities may be extended as needed. 1. Loosen two angle adjustment screws to allow for adjustment of pipe coupler angle. (See Figure 1) 2. Adjust pipe coupler to desired angle. (See Figure 1) 3. Tighten two angle adjustment screws. (See Figure 1) 4. Install 1-1/2" NPT following ANSI/ASME B1.20.1 (Schedule 40, 0.154" minimum thickness aluminum - ASTM B221) 6 x 2 Figure 2 wood stud surface (A)

threaded extension column (not included) into CMA395 until tight, with a minimum of four threads engaged. (See Figure 1) 5. Use set screw (C) to secure extension column to CMA395 coupler. (See Figure 1) extension pipe (not included) 5 (C) x 1 4 2 1 3 Figure 1 6. Determing mounting location on ceiling. 7. Use CMA395 (A) plate to mark hole locations for ceiling installation. (See Figure 2) 8. Drill two 1/4" pilot holes into wood joists at marked locations. 9. Install CMA395 (A) to ceiling using two 3/8 x 2 1/2" lag bolts (not included) and two 3/8" washers (not included). (See Figure 3) IMPORTANT ! : The CMA395 must be attached to ceiling using two 3/8 x 2 1/2" lag bolts and 3/8" washers (not included). WARNING: Failure to provide adequate structural strength for this component can result in serious personal injury or damage to equipment! It is the installer’s responsibility to make sure the structure to which this component is attached can support five times the combined weight of all equipment. Reinforce the structure as required before installing the component. (A) 3/8" washers (not included) 3/8 x 2 1/2" lag bolts (not included) Figure 3

4 Installation Instructions CMA395 Cable Management 1. If necessary, remove hex head bolt running through pipe channel in order to allow cables to be routed through pipe. (See Figure 4) NOTE: If cables are small enough to fit between bolt and pipe, bolt does not need to be removed. 2. Route cables through pipe as needed. (See Figure 4) 3. Reinstall hex head bolt and nut after cables have been properly routed. (See Figure 4) 2 (A)

1 Figure 4 3

5

CMA395 Installation Instructions 6 Installation Instructions CMA395 7

CMA395 Installation Instructions USA/International A 6436 City West Parkway, Eden Prairie, MN 55344 P 800.582.6480 / 952.225.6000 F 877.894.6918 / 952.894.6918 Europe A Franklinstraat 14, 6003 DK Weert, Netherlands P +31 (0) 495 580 852

Chief, a products division of Milestone AV Technologies 8803-002025 Rev03 ⁄2017 Milestone AV Technologies milestone.com 08/17 F +31 (0) 495 580 845 Asia Pacific A Office No. 918 on 9/F, Shatin Galleria 18-24 Shan Mei Street Fotan, Shatin, Hong Kong P 852 2145 4099 F 852 2145 4477


FREE ENGLISH PDF

OPERATING INSTRUCTIONS

USER GUIDE - USER MANUAL

OWNER GUIDE - OWNER MANUAL

REFERENCE GUIDE - REFERENCE MANUAL

INSTRUCTION GUIDE - INSTRUCTION MANUAL

Leave a Reply