FREE ENGLISH CDA CCA52 (01) PDF USER GUIDE
FREE ENGLISH CDA CCA52 (01) PDF USER MANUAL
FREE ENGLISH CDA CCA52 (01) PDF OWNER GUIDE
FREE ENGLISH CDA CCA52 (01) PDF OWNER MANUAL
FREE ENGLISH CDA CCA52 (01) PDF REFERENCE GUIDE
FREE ENGLISH CDA CCA52 (01) PDF INSTRUCTION GUIDE
FREE ENGLISH CDA CCA52 (01) PDF REFERENCE MANUAL
FREE ENGLISH CDA CCA52 (01) PDF INSTRUCTION MANUAL
FREE ENGLISH CDA CCA52 (01) PDF OPERATING INSTRUCTIONS


CLICK HERE TO DOWNLOAD CDA CCA52 (01) PDF MANUAL

If this is not the document you want for this product, click here to see if we have any other documents for this product.

Where can I find my appliance information?

Please enter the details on the appliance rating plate below for reference, to assist CDA Customer Care in the event of a fault with your appliance and to register your appliance for guarantee purposes.

Appliance Model
Serial Number

What are the important usage notes for this extractor?

Under no circumstances should the extractor be connected to any gas ventilation system, flue system or hot air ducting system.

Do not vent the extractor into an attic or loft space.

Only house the extractor in rooms with adequate ventilation. Remember that the extractor is powerful and whatever air is extracted needs to be replaced.

Do not tile the extractor in. It should be removable for service or maintenance.

Do not use silicone sealant to secure the hood to the wall.

You must be able to isolate the extractor from the mains electrical supply after installation.

This extractor has been designed to be used in a room with a volume of less than 36m³.

Steam cleaners must not be used when cleaning this appliance.

The performance of your extractor will vary depending on a number of factors. These include: type of extraction, length of ducting, room volume, ventilation available and cleanliness of the filters.


How should I use the extractor for best performance?

For best performance, you should switch on the extractor 15 minutes before starting to cook and leave it to run for approximately 15 minutes after the end of cooking.


How do I operate the control panel?

The control panel has the following buttons:

A – Power off button

B – Speed level buttons (1, 2, 3)

C – Light button

To switch the extractor light on or off:

Press button “C”.

To switch on the extractor or to change the speed at any time when the extractor is running:

Press the relevant “B” button for the first, second or third speed level as required.

To switch the extractor off:

Press the “A” button.


How do I clean the extractor?

IMPORTANT: DO NOT PERFORM MAINTENANCE OR CLEANING OF THE EXTRACTOR WITHOUT FIRST SWITCHING OFF THE ELECTRICITY SUPPLY.

You should use a non-abrasive cleaner. Any abrasive cleaner (including Cif) will scratch the surface and could erase the control panel markings.

You can clean your extractor effectively by simply using a dilute solution of water and mild detergent and drying to a shine with a clean cloth.


How do I clean the grease filter?

The grease filter should be kept clean to minimize the risk of fire.

At least once a month the grease filters should be removed and cleaned with warm soapy water. You can also wash the grease filters in a dishwasher, ensuring that the filters are put in an upright position to prevent damage from other items in the dishwasher. After rinsing and drying, replace the filter.

To remove the grease filter, push in the button on the handle and then pull down on the filter at the front. When you have released it at the front, then you can pull out the filter. To replace the grease filter, repeat the steps in reverse.

Please note: Cleaning the grease filter in the dishwasher may lead to discolouration. This is normal and does not constitute a fault with the appliance.

Please note: The extractor must not be used without the grease filter in place.


When and how should I replace the charcoal filter (for re-circulating mode)?

In re-circulating mode, air is vented back into the kitchen through the opening in the cooker hood. This method is advised if you are not using your hob intensively. Re-circulated air requires the use of charcoal filters to remove odours.

To ensure the best performance from your cooker hood, the charcoal filter should be replaced every 3-6 months, dependent on use.

Note: This charcoal filter is non-washable and must be replaced as required.

To attach a new charcoal filter, follow the steps below:

1. Remove the grease filter.

2. Place the charcoal filter on the centre of the motor support. Once firmly located, turn the charcoal filter clockwise 90 degrees until the filter locks into position.

3. Replace the grease filter.


What is the electrical information for this extractor?

Mains electrical voltage: 230 – 240Vac

Total rated power consumption: 44W


Why did my extractor switch off during cooking?

Your extractor is equipped with a motor protection device that will switch off the motor to prevent damage from overheating. This may happen during cooking when most or all of the zones/burners are being used simultaneously, or if your extractor is installed incorrectly, lower than the recommended height.

This is normal, and the extractor will work again once the motor has cooled sufficiently.


What should I do if my extractor is not working?

1. Check that the mains supply has not been switched off.

2. Check that the fuse in the spur has not blown.

If the problem persists, contact CDA Customer Care.


What are the minimum installation distances required for the extractor?

Above an electric hob: The minimum distance between the hob and extractor must exceed 600mm (650mm is recommended).

Above a gas hob: The minimum distance between the hob and extractor must exceed 700mm (750mm is recommended). If the instructions provided with your gas hob state that the required distance between the hob and the extractor must be greater than 700mm, then that is the distance which should be observed. This is a legal requirement. (The height should be measured from the top of the burners).

IN THE ABSENCE OF ANY INSTRUCTIONS SUPPLIED WITH THE GAS HOB, THE MINIMUM DISTANCE BETWEEN THE HOB AND EXTRACTOR MUST BE AT LEAST 760mm.

The width of any hob must not be greater than the width of the extractor installed above it.


What are the dimensions of the extractor and the required cut-out?

Extractor Dimensions:

CCA52 CCA72
A 518 698
B 499 679
C 515 795
D 480 660
E 260 260
F 274 274
G 200 200
H 282 282
I 173 173
J 10 10

Cut-out Dimensions:

CCA52 CCA72
A 499 679
B 487 667
C 268 268
D 200 200

What are the steps for installing the extractor?

1. Mark out the dimensions of the cut-out based on your extractor model.

2. Remove the grease filter, unscrew the 4 screws of the fixed panel and remove it.

3. Connect the exhaust pipe to the ducting adaptor and locate it on the extractor as indicated.

4. Place the extractor into the cabinet opening and secure it with screws.

5. Secure the panel on with the 4 previously removed screws and insert the grease filter.


What is the energy efficiency information for the extractor models?

Attribute Symbol CCA52 CCA72 Units
Model Identification CCA52 CCA72
Annual Energy Consumption AEC Hood 26.5 26.5 kWh
Time increase factor f 1.7 1.7
Fluid Dynamic Efficiency FDE Hood 9.4 9.4
Energy Efficiency Index EEI Hood 69.0 69.0
Measured airflow at Best Efficiency Point QBEP 94.7 94.7 m³/h
Measured Pressure at Best Efficiency Point PBEP 136 136 Pa
Maximum airflow QMAX 206.4 206.4 m³/h
Measured electric power at Best Efficiency Point WBEP 38.0 38.0 W
Nominal lighting power WL 4.0 4.0 W
Average illumination of the lighting system on the cooking surface EMiddle 309 309 Lux
Measured power consumption in standby Ps N/A N/A W
Measured power consumption off mode Po 0.0 0.0 W
Sound power level LWA 63 63 dBA
Grease Filter Efficiency GFE Hood 49.1 (F) 49.1 (F) %
Lamp efficiency LEHood 77 (A) 77 (A) %

CLICK HERE TO DOWNLOAD CDA CCA52 (01) PDF MANUAL