FREE ENGLISH CAMDEN OE-ED2000 (01) PDF USER GUIDE
FREE ENGLISH CAMDEN OE-ED2000 (01) PDF USER MANUAL
FREE ENGLISH CAMDEN OE-ED2000 (01) PDF OWNER GUIDE
FREE ENGLISH CAMDEN OE-ED2000 (01) PDF OWNER MANUAL
FREE ENGLISH CAMDEN OE-ED2000 (01) PDF REFERENCE GUIDE
FREE ENGLISH CAMDEN OE-ED2000 (01) PDF INSTRUCTION GUIDE
FREE ENGLISH CAMDEN OE-ED2000 (01) PDF REFERENCE MANUAL
FREE ENGLISH CAMDEN OE-ED2000 (01) PDF INSTRUCTION MANUAL
FREE ENGLISH CAMDEN OE-ED2000 (01) PDF OPERATING INSTRUCTIONS
CLICK HERE TO DOWNLOAD CAMDEN OE-ED2000 (01) PDF MANUAL
If this is not the document you want for this product, click here to see if we have any other documents for this product.
How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.
What is included in the OE-ED2000 package?
The package includes the following items:
1- 4 PIN power connector
4- Wire nuts
5- M5 x 12mm screws
2- #10 x 1 1/4″ wood screws
2- #10-32 x 1/2″ screws
2- Mounting brackets
2- Spacers
What are the specifications of the OE-ED2000 electric strike?
| Voltage | 12/24V AC/DC |
| Current Draw | 300mA@12V DC 150mA@24V DC |
| Static Strength | 1,000 Lbs. |
| Dynamic Strength | 50 Ft-Lbs. |
| Endurance | 700,000 Cycles (Factory Tested) 250,000 Cycles (UL Verified) |
| Mode | Field Selectable Fail Safe/Fail Secure |
| Mech. Adjustment | Strike Body/Faceplate |
| Operation | AC-Buzz DC-Silent |
| Duty | Continuous |
| Dimensions (Body) | 3 3/8″ H x 1 7/8″ W x 1 7/32″ D (86mm x 47mm x 31mm) |
What are the UL 294 Performance Levels?
– Line Security = Level I
– Attack Level = Level I
– Endurance Level = Level IV
– Standby Power = Level I
How do I install the OE-ED2000 electric strike?
1. Prepare the door jamb as per the appropriate drawing.
2. Install mounting brackets to jamb using M5x12 screws and pressed metal nuts. Do not tighten.
3. Spacers are used to assure flush final assembly of faceplate into jamb. Add one of more spacers between jamb and mounting bracket when face plate extends beyond the jamb. When the faceplate sits inside the jamb, spacers must be added between the mounting bracket & the lip bracket. Make sure clearance hole in spacer aligns with hole in mounting bracket.
4. Connect wires coming from the low voltage side of the transformer to wires (black) from strike.
5. Install electric strike jamb by attaching with # 10-32 screws and lockwashers.
6. Secure M5x12 screws holding mounting brackets to jamb.
Note: The products are intended to be installed in accordance with the installation wiring diagram, mechanical assembly drawings provided with each product, the local authority having jurisdiction (AHJ) and the National Electric Code, NFPA 70. When installed in fail secure mode, the local authority shall be consulted with regard to the use of possible panic hardware to allow emergency exit from the secure area.
The electric door strike shall be installed in such a way and in such a location so as to not impair the operation of an emergency exit device or panic hardware mounted on the door.
How should the electric strike be wired?
A varistor is provided to protect/prevent the strike from spikes. Connect the varistor between the input wires.
Power Connections:
12VDC
Red/Black: +12V
Blue/Green: Ground
24VDC
Red: +24V
Black/Blue: –
Green: Ground
For cut wires:
12V
(+12V) Varistor: Red
(-): Black, Blue, Green
24V
(+24V) Varistor: Red
(-): Black, Blue, Green
Note: For UL 294 / UL 1034 compliance the door strikes are to be powered via a UL 294/ UL 603 class 2 power limited output from a control panel and or power supply. Furthermore, when powered by AC/DC the units shall use a UL regulated UL 294/ UL 603 power limited class 2 output rated 12/24V with AC on indicator.
How do I modify the operation mode between fail-safe and fail-secure?
To modify the mode from fail-safe to fail-secure or vice versa, follow these steps:
(1) Loosen the Set Screw.
(2) Rotate the Mode Selector to the desired setting. (FL – Fail-Secure, FS – Fail-Safe). The Set Screw will slide to its new position as the Mode Selector is rotated.
(3) Tighten the Set screw.
Note: FS = Fail Safe, FL = Fail Lock (Fail Secure)
What faceplates are available?
The following faceplates are available:
OE-EFS1 – ANSI SQUARE
OE-EFS2 – ANSI ROUND
OE-EFS3 – WOOD DOOR
OE-EFS4 – HOLLOW METAL DOOR