Free English BLUE AIR BASS6 (01) PDF document. Download the PDF, use the online viewer, or browse the FAQs for easy troubleshooting.


CLICK HERE TO DOWNLOAD BLUE AIR BASS6 (01) PDF DOCUMENT

If this is not the document you want for this product, click here to see if we have any other documents for this product.

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

What are the handling instructions before hooking up a condensing unit to the BLUE AIR BASS6?

Before hooking up a condensing unit to the BLUE AIR BASS6, please follow these instructions:

1. Please handle with care and Do not make the Inlet /Outlet gas nozzles touch the ground directly.

2. Please check and make sure Gas doesn’t leak after hooking up.

3. Please have the condensing unit meet the recommended horse power (HP).


What are the recommended condensing unit Horse Power (HP) specifications for the BLUE AIR BASS6 and other models?

The following table outlines the recommended Horse Power based on the model, the number of linked combinations, and whether the installation is In-Door or Out-Door:

Model Item Description (Outside Dimension) # of Linked Combination Recommended HP IN-DOOR Installation (c/u) Recommended HP OUT-DOOR Installation (c/u)
BASS4 4 feet
(47 1/4” x 11 3/8” x 10 5/8”)
1 Unit 1/4 HP 1/3 HP
2 Units 1/3 HP 1/2 HP
3 Units 1/2 HP 1/2 HP
BASS5 5 feet
(59 1/8” x 11 3/8” x 10 5/8”)
1 Unit 1/4 HP 1/3 HP
2 Units 1/3 HP 1/2 HP
3 Units 1/2 HP 3/4 HP
BASS6 6 feet
(70 7/8” x 11 3/8” x 10 5/8”)
1 Unit 1/3 HP 1/2 HP
2 Units 1/2 HP 3/4 HP
3 Units 3/4 HP 1 HP

How are “In Door” and “Out Door” installations defined regarding distance for the BLUE AIR BASS6?

For the BLUE AIR BASS6, the installation types are defined by the distance between the Remote Sushi Display case and the Condensing Unit:

In Door: Less than 15ft between the Remote Sushi Display case and Condensing Unit.

Out Door: Less than 15 ~ 30ft between the Remote Sushi Display case and Condensing Unit. (Do not make over length).


What type of expansion valve is recommended for use with the BLUE AIR BASS6?

We recommend using an expansion valve that is not equipped with a thermo-sensor for the BLUE AIR BASS6.