****** Page 1 ****** Atlantis KC-3200ZB / BL-6000ZB Wireless Linear Imager Wireless Laser scanner Configuration Guide -1-

****** Page 2 ****** Table of Contents Chapter 1 System Information 1.1 About this manual 1.2 How to set up the parameter Chapter 2 System Setup 2.1 Terminator 2.2 String Options (Prefix & Suffix) 2.3 Setup Insertion Chapter 3 BarCode parameters setting 3.5 3.8 3.9 3.1 3.2 3.3 3.4 3. 3. 3. 6 7 10 II 3.12 3.13 3.14 3.15 3.16 3.17 UPC-A UPC-E EAN-13 EAN-8 Code39 Codabar Code93 Code128 Interleaved2 of 5 Industrial 20f 5 Matrix 2 of 5 China Postage MSI/Plessey Code 32 Code 11 Tel epen GSI DataBar Appendix 3 3 5 6 11 14 17 19 21 24 28 30 33 35 37 39 41 43 45 47 49 50 -2-

****** Page 3 ****** Chapter 1 – System Information 1.1 About this manual This User’s Guide provides detailed programming instructions. Barcode scanners are factory programmed for the most common communication setting. If you need to change these settings, programming is accomplished by scanning the bar codes in this guide. 1.2 (1) (2) (3) How to set up the parameter -I Scan Start Configuration Scan all necessary labels for parameters that meet your applications. Scan End Configuration to end the programming. Start configuration End configuration Default setting Check Version An asterisk ( * ) next to an option indicate the defa ult setting. -3-

****** Page 4 ****** 1.2 How to set up the parameter – II Most of time the scanner only requests one read of parameters when changing to new values. You will hear two beeps when you successfully set to the new values. But for some special parameters, multiple reads are needed to complete the configuration. When use these special In some cases, you might need to read one or more barcodes, parameters. such as: Hexadecimal barcodes. For example: prefix, suffix, etc. Numeric barcodes. For example: inter-character delay, max/min length To complete the change of setting you will need to read the “Confirm” barcode after you read the parameter. Below is the flow chart to explain two different configurations. Start Configuratione Parameters End Configuration Start Configuration Special Label (ex: prefix) Two Hexadecimal barcodes Confirm Configuration End Configuration -4-

****** Page 5 ****** Chapter 2 – System setup Start configuration 2.1 Terminator ITEM Output Characters End configuration OPTION None *CR+LF CR Tab -5-

****** Page 6 ****** 2.2 String Options (Prefix & Suffix) This section describes the alterations which can be made to the format of the transmitted data string. A prefix and suffix of maximum 10 direct input may be included in front and at the end of scanned barcode. Format {Prefix} {Code ID} {Bar Code} {Suffix} How to set up a prefix? To configure “## “as prefix (1) (2) (3) (4) (5) Scan Start Configuration barcode Scan Preamble bar code Scan W’ twice from FULL ASCII table Scan Confirm configuration barcode Scan End Configuration barcode. How to set up a suffix? To configure “$9″ as suffix (1) (2) (3) (4) (5) Start configuration barcode Scan Postamble barcode Scan ‘$” twice from FULL ASCII ta ble Scan Confirm configuration barcode Scan End configuration barcode. -6-

****** Page 7 ****** 2.3 Setup Insertion This section describes how to setup the insertion of output. GI Insertion Character G2 Insertion Character Insertion Group Selection (01) GI Character Position 62 Character Position Insertion Group Selection (01) Insertion Group Selection (02) Insertion Group Selection (02) Insertion Groups (01) (02) can be applied to all kind of different ba rcodes. 6. 7. 8. 9. 10. 11. 12. NOTE : UPC-A 8. UPC-E 1. EAN-13 2. EAN-8 3. code 39 4. Codabar 5. Code 93 Code 128 Interleaved 2 of 5 Industrial 2 of 5 Matrix 2 of S China postage MSI/Plessey Max. 10 charters can be inserted each time Max. Insertion group is only two. Insertion group (01) or (02) can be used in different kinds of barcodes at the same time

****** Page 8 ****** Example: To insert character “A” before the third digit(3) Make the decoded data: 12A3456789 How to set up a character you want to insert (1) (2) (3) (4) (5) Scan Start Configuration barcode Scan “Gl Insertion character” Scan “4” and “1” from FULL ASCII Table Scan Confirm configuration barcode Scan End configuration barcode How to set up position you wish to place the character (6) (7) (8) (9) (10) Scan Start Configuration barcode Scan “GI Character Position” Scan “0” and ‘$3″ from FULL ASCII Table (which presents the position) Scan Confirm configuration barcode Scan End configuration barcode How to set up insertion for code 39 Go to chapter 3.5 (code 39) (11) Scan Start Configuration barcode (12) Scan “Insert group selection” bar code (13) scan “0” and “1” from FULL ASCII Table (which presents the group- 01 you just set up previously) (14) Scan Confirm configuration bar code (15) Scan End configuration barcode -8-

****** Page 9 ****** Start configuration Confirm configuration ITEM Preamble (Default : 00) Postamble (Default : 00) GI Insertion character (Default : 00) G2 Insertion character (Default : 00) Gl Character Position to be inserted (Default : 00) G2 Character Position to be inserted (Default : 00) End configuration OPTION Ref: Appendix I I II II III II I II II Ref: Appendix I I II III I II II II Ref: Appendix Ref: Appendix Ref: Appendix Ref: Appendix -9-

****** Page 10 ****** Start configuration ITEM Bar Code ID Accuracy Positive and negative bar codes End configuration OPTION *Disable Enable * Read 1 Time Read 2 Times Negative bar codes *Positive bar codes Code Type UPC-A UPC-E EAN-13 EAN-8 code 39 Codabar Code 93 Code 128 G H J K L M Code Type Interleaved 25 Industrial 25 Matrix 25 China Postal Code MSI/PIessey Code 32 Code 11 Telepen o p s -10-

****** Page 11 ****** BarCode parameters setting Chapter 3 – How to set up a Code ID? (1) Scan Start configuration bar code (2) Go to the ASCII Table and scan label that represent the desired characters to be inserted. (3) Scan Confirm configuration bar code (4) Scan End configuration bar code. Start configuration Confirm configuration 3.1 UPC-A ITEM Read Code ID Setting (Default : F) End configuration OPTION Disable * Enable Ref: Appendix (20-7EH) -11-

****** Page 12 ****** Start configuration ITEM UPC-A Expand to EAN-13 Check Digit Send Truncate Leading Zero Truncate Leading (Defa ult:00) Truncate Ending (Default:OO) Insert group selection End configuration OPTION * Disable Enable Disable * Enable * Disable Enable Ref: Appendix (00-ODH) Ref: Appendix (00-ODH) Ref: Appendix (00—02H -12-

****** Page 13 ****** Start configuration ITEM Supplement digits End configuration OPTION * NONE I I I I I I I I I I I I II I I I 2 digits 5 digits 2 or 5digits Auto-discriminate Supplement -13-

****** Page 14 ****** 3.2 UPC-E Start configuration ITEM Read Code ID setting (Default : G) End configuration OPTION Disable * Enable Ref: Appendix (20-7EH) -14-

****** Page 15 ****** Start configuration ITEM UPC-E Expand to UPC-A Check Digit Send Truncate Leading (Defa ult:OO) Truncate Ending (Defa ult:00) Insert group selection (Defa ult:00) End configuration OPTION * Disable Enable Disable * Enable Ref: Appendix (00-08H) Ref: Appendix (00-08H) Ref: Appendix (00-02H) -15-

****** Page 16 ****** Start configuration ITEM Truncate Leading Zero Supplement digits End configuration OPTION *Disable Enable 2 digits 5 digits 2 or 5 digits Auto-discriminate Supplement -16-

****** Page 17 ****** 3.3 EAN-13 Start configuration ITEM Read Code ID setting (Default : H) Check Digit Send Truncate Leading (Default : 00 ) Truncate Ending (Default : 00 ) End configuration OPTION Disable * Enable Ref: Appendix (20-7EH) Disable * Enable Ref: Appendix (OO-ODH) Ref: Appendix (00-ODH) -17-

****** Page 18 ****** Start configuration ITEM Supplement digits ISBN/ISSN Conversion Insert group selection (Default : 00 ) End configuration OPTION None 2 digits 5 digits 2 or 5 digits III Auto-discriminate Supplement * Disable Enable Ref: Appendix (00-02H) -18-

****** Page 19 ****** 3.4 EAN-8 Start configuration ITEM Read Code ID setting (Default : I) Check Digit Send Truncate Leading (Default : 00) End configuration OPTION Disable * Enable Ref: Appendix (20-7EH) Disable * Enable Ref: Appendix (00-08H) -19-

****** Page 20 ****** Start configuration ITEM Truncate Ending (Default : 00) Supplement digits Insert group selection (Default : 00) End configuration OPTION Ref: Appendix (00-08H) 2 digits 5 digits 2 or 5 digits Auto-discriminate Supplement Ref: Appendix (00-02H) -20-

****** Page 21 ****** 3.5 Code39 Start configuration ITEM Read Code ID setting (Default : J) Check-sum verification Check-sum transmission End configuration OPTION Disable * Enable Ref: Appendix (20-7EH) * Disable Enable Disable * Enable -21-

****** Page 22 ****** Start configuration ITEM Append Min. code length (Default: 00) Max. code length (Default: 32H) Format End configuration OPTION * Disable Enable Ref: Appendix (00-32H) Ref: Appendix (00-32H) * Standard Code39 Code 39 Full ASCII – 22 –

****** Page 23 ****** Start configuration ITEM Transmit Start/End Character Truncate Leading (Default: 00) Truncate Ending (Default: 00) Insert group selection (Default: 00) End configuration OPTION * Disable Enable Ref: Appendix (00-32H) Ref: Appendix (00-32H) Ref: Appendix (00-02H) -23 –

****** Page 24 ****** 3.6 Codabar Start configuration ITEM Read Code ID setting (Default : K) End configuration OPTION Disable * Enable Ref: Appendix (20-7EH) – 24 –

****** Page 25 ****** Start configuration ITEM Check-sum verification Check-sum transmission Append Truncate Leading (Defa ult:00) End configuration OPTION Disable * Enable * Disable Enable * Disable Enable Ref: Appendix (OO-7EH) -25 –

****** Page 26 ****** Start configuration ITEM Truncate Ending (Default:OO) Start/End type Start/End transmission Min. code length (Default: 05) End configuration OPTION Ref: Appendix (00-7EH) * ABCD/ABCD abcd/abcd abcd/tn*e * Disable Enable Ref: Appendix (00-3CH) -26-

****** Page 27 ****** Start configuration ITEM Max. code length (Default: 3CH) Insert group selection (Default: 00) End configuration OPTION Ref: Appendix (00-3CH) Ref: Appendix (00-02H) -27-

****** Page 28 ****** 3.7 Code93 Start configuration ITEM Read Code ID setting (Default : L) Check-sum verification End configuration OPTION Disable * Enable Ref: Appendix (20-7EH) Disable * Enable -28-

****** Page 29 ****** Start configuration ITEM Check-sum transmission Min. code length (Default: 00) Max. code length (Default: 50H) Truncate Leading (Default: 00) Truncate Ending (Default: 00) Insert group selection End configuration OPTION * Disable Enable Ref: Appendix (0-50H) Ref: Appendix (0-50H) Ref: Appendix (00-7EH) Ref: Appendix (00-7EH) Ref: Appendix (00-02H) -29-

****** Page 30 ****** 3.8 Code 128 Start configuration ITEM Read Code ID setting (Default : M) Check-sum verification End configuration OPTION Disable * Enable Ref: Appendix (20-7EH) Disable * Enable -30-

****** Page 31 ****** Start configuration ITEM Check-sum transmission FNC2 Append UCC/EAN128 FNCI transmission End configuration OPTION * Disable Enable * Disable Enable * Disable Enable * Disable Enable -31-

****** Page 32 ****** Start configuration ITEM Truncate Leading (Default: 00) Truncate Ending (Default: 00) Min. code length (Default: 00) Max. code length (Default: 7FH) Insert group selection (Default: 00) End configuration OPTION Ref: Appendix (00-7FH) Ref: Appendix (00-7FH) Ref: Appendix (00-7FH) Ref: Appendix (00-7FH) Ref: Appendix (00-02H) -32-

****** Page 33 ****** 3.9 Interleaved 2 of 5 Start configuration ITEM Read Code ID setting (Default : N) Check-sum verification Check-sum transmission End configuration OPTION * Disable Enable Ref: Appendix (20-7EH) Disable * Enable Disable * Enable -33-

****** Page 34 ****** Start configuration ITEM Truncate Leading (Default : 00) Truncate Ending (Default : 00) Min. code length (Defa ult : 04) Max. code length (Default : 7FH) Insert group selection (Default : 00) End configuration OPTION Ref: Appendix (00-7EH) Ref: Appendix (OO-7EH) Ref: Appendix (04-7FH) Ref: Appendix (00-7FH) Ref: Appendix (00-02H) -34-

****** Page 35 ****** 3.10 Industrial 2 of 5 Start configuration ITEM Read Code ID setting (Default : O) Min. code length (Default : 00) Max. code length (Default : 321-1) End configuration OPTICON * Disable Enable Ref: Appendix (20-7EH) Ref: Appendix (00-32H) Ref: Appendix (00-32H) -35-

****** Page 36 ****** Start configuration ITEM Truncate Leading (Default : 00) Truncate Ending (Default : 00) Check-sum verification Check-sum transmission Insert group selection (Defa ult : 00) End configuration OPTION Ref: Appendix (00-32H) Ref: Appendix (00-32H) * Disable Enable Disable II II II II II III I * Enable Ref: Appendix (00-02H) -36-

****** Page 37 ****** 3.11 Matrix 2 of 5 Start configuration ITEM Read Code ID setting (Default : P) Check-sum verification End configuration OPTION * Disable Enable Ref: Appendix (20-7EH) * Disable Enable -37-

****** Page 38 ****** Start configuration ITEM Check-sum transmission Truncate Leading (Default : 00) Truncate Ending (Default : 00) Min. code length (Defa ult : 0B) Max. code length (Default : 5014) Insert group selection (Default : 00) End configuration OPTION Disable * Enable Ref: Appendix (00-50H) Appendix (00-50H) Ref: Ref: Appendix (00-50M) Appendix (00-50H) Ref: Appendix (00-02H) Ref: -38-

****** Page 39 ****** 3.12 CHINA POSTAL CODE Start configuration ITEM Read Code ID setting (Default : Q) Check-sum verification Check-sum transmission End configuration OPTION * Disable I III I I II II Enable Ref: Appendix (20-7EH) * Disable Enable Disable * Enable -39-

****** Page 40 ****** Start configuration ITEM Truncate Leading (Default : 00) Truncate Ending (Default : 00) Min.code length (Defa ult : 00) Max.code length (Default : 50H) Insert group selection (Default • 00) End configuration OPTION Ref: Appendix (00-50H) Ref: Appendix (00-50H) Ref: Appendix (00-50H) Ref: Appendix (00-50H) Ref: Appendix (00-02H) – 40 –

****** Page 41 ****** 3.13 MSI/Plessey Start configuration ITEM Read Code ID setting (Default : R) Check-sum verification End configuration OPTION * Disable Enable Ref: Appendix (20-7EH) * Disable MOD 10 MOD 10/10 MOD 11/10 -41-

****** Page 42 ****** Start configuration ITEM Check-sum transmission Truncate Leading (Default : 00) Truncate Ending (Default : 00) Min. code length (Defa ult : 00) Max. code length (Default : 3CH) Insert group selection (Default : 00) End configuration OPTION Disable * Enable Ref: Appendix (00-3CH) Ref: Appendix (00-3CH) Ref: Appendix (00-3CH) Ref: Appendix (00-3CH) Ref: Appendix (00-02H) – 42 –

****** Page 43 ****** 3.14 CODE 32 Start configuration ITEM Read Code ID Setting (Defa ult:S) Check-sum verification Check-sum transmission End configuration OPTION * Disable Enable Ref: Appendix (20-7EH) Disable * Enable Disable * Enable -43 –

****** Page 44 ****** Start configuration ITEM Truncate Leading (Default : 00) Truncate Ending (Default : 00) Insert group selection (Default : 00) End configuration OPTION Ref: Appendix (00-OAH) Ref: Appendix (00-OAH) Ref: Appendix (00-02H) – 44 –

****** Page 45 ****** 3.15 CODE 11 Start configuration ITEM Read Code ID setting (Default:T) Check-sum verification End configuration OPTION * Disable Enable Ref: Appendix (20-7EH) Disable * Enable – 45 –

****** Page 46 ****** Start configuration ITEM Check-sum transmission Truncate Leading (Default : 00) Truncate Ending (Default : 00) Min. code length (Default : 00) Max. code length (Default : 50H) Insert group selection (Default : 00) End configuration OPTION * Disable Enable Ref: Appendix (00-50H) Ref: Appendix (00-50H) Ref: Appendix (00-50H) Ref: Appendix (00-50H) Ref: Appendix (00-02H)

****** Page 47 ****** 3.16 Telepen Start configuration ITEM Read Code ID setting (Defa ult:V) Check-sum verification Data Format End configuration OPTION * Disable Enable Ref: Appendix (20-7EH) Disable * Enable Only Numnic *Full ASCII -47-

****** Page 48 ****** Start configuration ITEM Check-sum transmission Truncate Leading (Default : 00) Truncate Ending (Default : 00) Min. code length (Default : 00) Max. code length (Default : 40H) Insert group selection (Default : 00) End configuration OPTION * Disable Enable Ref: Appendix (00401-1) Ref: Appendix (00-40H) Ref: Appendix (00-40H) Ref: Appendix (00-40H) Ref: Appendix (00-02H) -48-

****** Page 49 ****** 3.17 GSI Data Bar (RSS) Start configuration ITEM RSS-14 RSS-14 LIMITED RSS-14 EXPANDED RSS TO UPC/EAN End configuration OPTION Enable *Disable Enable *Disable Enable *Disable Enable *Disable – 49-

****** Page 50 ****** Appendix A — -50-

****** Page 51 ****** Dec 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Hex oo 01 02 03 04 05 06 07 08 09 OA oc OD 10 11 12 13 15 16 17 18 19 1B IF Char. NUL SOH STX ETX EOT ENQ ACK BEL BS CR so Sl DLE DCI DC2 DC3 DC4 NAK SYN ETB CAN SUB ESC FS GS RS US Dec 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 Hex 20 21 22 23 24 25 26 27 28 29 2A 2B 2D 30 31 32 33 35 36 37 38 39 3B 3D Char. -51-

****** Page 52 ****** Dec 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 82 83 84 85 86 87 88 89 90 91 92 93 94 95 Hex 40 41 42 43 44 45 46 47 48 49 4B 4C 4E 50 51 52 53 54 55 56 57 58 59 5B 5E Char. Dec 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 Hex 60 61 62 63 65 66 67 68 69 6B 6F 70 71 72 73 74 75 76 77 78 79 7B 7E Char. DEL -52-

****** Page 53 ****** Table-Hex 1 2 3 4 5 6 7 8 9 0 HEXADCIMAL c D F III Confirm configuration III End Configuration -53-

****** Page 54 ****** Atlantis -54- Version: 3.2

FREE ENGLISH PDF

OPERATING INSTRUCTIONS

USER GUIDE – USER MANUAL

OWNER GUIDE – OWNER MANUAL

REFERENCE GUIDE – REFERENCE MANUAL

INSTRUCTION GUIDE – INSTRUCTION MANUAL



ATLANTIS KC-3200ZB (01) PDF MANUAL

Leave a comment, question, review or page error below.

This site uses Akismet to reduce spam. Learn how your comment data is processed.